Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FAI23-0002 040-310-093 Truroots 37 Fire Alarm System Documents 6-5-23
��►_� aes-corp.com.40-„,-,E ______ _________ ,_ .. of SECURITY ,,a?�. ih'��°�S"� '�., . .,i CORPORATION INNOVATION 7707 Fire Subscribers ...., ......... .. ..„ ..- _,. IntelliNet 2,0 ), ..., ... . . ? .•••••• .. . ____A.__ ?au, . .. . . ... . . : .. 1 .. . •... ... : . •.. • A Newer, Smarter Alarm . • Communications Platform Feature Highlights lime. • Leverages state of the art technology • Applies advanced security protection ._ • Offers flexible power and configuration optionsGU �� 71 FIRE • Engineered for backward compatibility with legacy systems NFPA LISTED ��� • Enables future ready capabilities • Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button • Includes dual communication/multiple communication technology(reporting over RF and IP. • Improves functionality with an adaptive Graphic User Interface(GUI)for programming via smartphones,tablets and PCs • Plus many more... Key Benefits • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks • Protects subscriber units against unauthorized access and rogue activity with a password-protected Dealer Code • Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-IntelliPro full data module • Provides versatile power options: (1) Direct from the Fire Alarm Control Panel (FACP)without requiring an electrician onsite and without Subscriber backup battery; (2) Directly from the FACP with Subscriber backup battery; or (3)Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards www.aes-corp.com Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network. The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data module option,they are the ideal drop-in replacement for Plain Old Telephone Service (POTS) lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status.The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop,tablet, or integrated Universal Serial Bus (USB)—without the need for special cables or having to use a handheld programmer.Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network D)Burglary D Subscriber ® _ B n8ev ` _ I --f 1 . , I • C i N B)Fire 1 i ' i Subscriber ' 1 �r 1 J' 1 �' i� • ®I D AES-Ne[work Management System I � I • � M ® nrornet __�r i B —, Primary AES-MultiNet Receiver I Mil` • A)Alarm 7707 Panel 'I Secondary AES-MultiNet Receiver I • ' B Alarm Automation ■■ ■ • • -----B ,� �� C A 7707 --- C)IPLinks --_ -- ^`- - ems Customer Location I Mesh Radio Technology Central Monitoring Station Alarm Panel&AES Subscriber Multi-path AES-IntelliNet®Network Primary&Secondary AES-MultiNet System sends critical event signal delivers alarm signals via smart routing receives transmission in 1-3 seconds The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add-on accessory board.AES subscribers'intelligent software automatically detects new hardware and devices to reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming.A laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units. A FACP Power Supply Adapter is required for certain configurations when using flexible power options. The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians to get in, out, and on to the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: aes-corp.com/prod ucts/fire/fi re-marshal-resources www.aes-corp.com How to Order 7707 Fire IntelliNet 2.0 Fire Subscribers 2.0 PREMIUM (UL & ULC Listed) 7707P 88 M IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies (MCT), Red Enclosure 7707P 88 ULP M IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707P 44 M IntelliNet 2.0 Fire Subscriber,4x4 Zone (4 Reversing Polarity,4 Supervised)with Multiple Communication Technologies (MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber,4x4 Zone (4 Reversing Polarity,4 Supervised) 7707P-44-ULP-M with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 2.0 ACCESSORIES 7794A Standalone AES-IntelliPro Fire full data module add-on accessory board with firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-way Junction Box Legacy Fire Subscribers 7706-ULF Integrated Fire Monitoring System, Red Enclosure 7788E ULP P Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro(7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7788E ULP Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7788F Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure 7744E ULP P Legacy Fire Subscriber,4 Zone with 7795 AES-IntelliPro(7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7744E ULP Legacy Fire Subscriber,4x4 Zone, 4 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7744E Legacy Fire Subscriber,4x4 Zone, 4 Reversing Polarity,4 Supervised Zones, Red Enclosure LEGACY ACCESSORIES I 7794 Standalone AES-IntelliPro Fire full data module add-on accessory board for legacy units only, please see 7794A above for IntelliNet 2.0 version www.aes-corp.com Technical Specifications 7707 Fire DIMENSIONS ALARM SIGNAL INPUTS/ZONES PORTS 13"H x 8.5"W x 4.5"D • 8 individually programmable Ethernet for configuration (33cmH x 21.5cmW x 11.4cmD) E.O.L.type zone inputs and message communication • 4+4:4 reverse polarity input and USB access for software upgrade WEIGHT 4 individually programmable 5.8 lbs(2.6 kilograms) E.O.L.type zone inputs REMOTE ANNUNCIATOR excluding battery • Optional 7794A AES-IntelliPro for AES Model 7740 13 lbs(5.9 kilograms)with full data via Contact ID, Pulse, Remote Annunciator, supervised 10 Ah battery Modem Ile and Modem II1a2 COMPATIBLE RECEIVERS RADIO FREQUENCY UL LISTINGS 7705i AES-MultiNet Receiver Standard Frequency Range: UL 864 10th Edition 450-470 MHz Standard for Control Units and CONFIGURATION INTERFACE Contact AES for other UHF Accessories for Fire Alarm Systems Web browser capable device and VHF frequencies ULC S559-04 1st Edition accessible via smartphone,tablet, Equipment for Fire Signal laptop, or PC ANTENNA Receiving Centres and Systems 2.5 dB tamper resistant antenna CURRENT CONSUMPTION included, mounts on enclosure Standby w/charged backup battery: Optional remote mounting TROUBLE OUTPUT—ACK 200 mA(1.2 A Transmitting) antenna available DELAY/ANTENNA CUT Standby+ charging backup battery: Form C relay,fail secure, rated 24V 900 mA(1.9 A Transmitting- MAX) POWER INPUT DC 1A resistive, unsupervised AC SOURCES POWER OUTPUT Transformer: Class 2 RESET BUTTON 2 or 5 Watts 16.5V AC nominal output Located on main circuit board Factory set 1.9 A max current(40 VA MIN) ELK ELK-TRG1640, OPERATING TEMPERATURE ENCLOSURE MATERIAL MG ELECTRONIC SALES MGT1640, 32 to 120°F(0 to 49°C) Steel with paint finish or AES 1640(not included) DC SOURCES(includesFACP) STORAGE TEMPERATURE FINISH COLOR 24V DC Regulated Power Supply 14 to 140°F(-10 to 60°C) Red with Subscriber Rechargeable Battery RELATIVE HUMIDITY VISUAL INDICATORS 1.9 A max current 0 to 93%, non-condensing Front panel LCD (2 x 20 alphanumeric character BACKUP BATTERY RECHARGE CAPABILITY backlit display) 10-12 Ah, UL recognized lead acid Will charge 12V battery size Power and Trouble LEDs gel cell, size based on subscriber from 10-12 Ah (ALM,Trouble,Tx, Rx,WA) configuration Contact Us For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com. 00000 www.aes-corp.com AES Corporation 1285 Newbury Street I Peabody, MA 01960 United States ©Copyright 2022 AES Corporation and AES-IntelliNet©are registered trademarks of AES Corporation 7707_05202022 ^`Es+m:i:EPERroh CALIFORNIA DEPARTMENT OF FORESTRY&FIRE PROTECTION AL OFFICE OF THE STATE FIRE MARSHAL FIRE FIRE ENGINEERING-BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1516:0501 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: AES CORPORATION285 NEWBURY ST, PEABODY, MA 01960 Contact: Justin Mitchell (978)839-7063 Fax(978)535-7313 Email:jmitchell@aes-corp.com DESIGN: AES Model 7707 Subscriber Unit, one-way RF receiver and listed accessories intended to be connected to a separately listed fire alarm control unit.Accessories listed for use with this unit are subassembly modules 7711 and 7712, and 7794A digital dialer interface. Refer to listee's Installation Instruction Manual for details. RATING: 120 VAC, 60Hz, 1.75 Amp 24VDC, 1.3 Amp INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a subscriber unit for use with separately listed AES Model 7705i receiver(CSFM# 7300-1516:0104) and Model 7170 IP-Link(CSFM#7300-1516:0105). 05-19-2017 dcc "j;s*,-,7F This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not O` an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Yuasa Technical Data Sheet Yuasa NP12-12 Industrial VRLA Battery Specifications Nominal voltage(V) 12 YUASA 20-hr rate Capacity to 10.5V at 20°C(Ah) 12 10-hr rate Capacity to 10.8V at 20°C(Ah) 11.1 Dimensions Length(mm) 151 (±1) Width(mm) 98(±1) 111M - Height over terminals(mm) 97.5(±2) Mass(kg) 4.05 121;12Ah NP12-12 Terminal Type yp1vB-12 FASTON -Quickfit/release(JST where stated) 6.35 'ec'e"dNP' YUASA rechargeable 7anery Operating Temperature Range �•� wW �°:.° �� Storage(in fully charged condition) -20°C to+60°C 114 its ap��,, Charge -15°C to+50°C ikk ''"w Discharge -20°C to+60°C Storage Capacity loss per month at 20°C(%approx.) 3 Case Material Layout Standard ABS(UL94:HB) FR version available UL94:VO Charge Voltage 0 Float charge voltage at 20°C(V)/Block 13.65(±1%) Float charge voltage at 20°C(V)/Cell 2.275(±1%) Float Chg voltage tmp correction factor from std -3 20°C(mV) Cyclic(or Boost)charge Voltage at 20°C(V)/Block 14.5(±3%) Cyclic(or Boost)charge Voltage at 20°C(V)/Cell 2.42(±3%) Cyclic Chg voltage tmp correction factor from std -4 20°C(mV) 3rd Party Certifications Charge Current IS09001 -Quality Management Systems Float charge current limit(A) No limit UNDERWRITERS LABORATORIES Inc. Cyclic(or Boost)charge current limit(A) 3 (21 Maximum Discharge Current (Z1195g. 1 second(A) 360 Cert.No.:FM 10626 1 minute(A) 75 Short-Circuit Current&Internal Resistance Safety Internal resistance-according to EN IEC 60896-21 44.39 (m0) Installation Short Circuit current according to EN IEC 320 Can be installed and operated in any orientation except 60896-21 (A) permanently inverted. Impedance Handles Measured at 1 kHz(ma) 16 Batteries must not be suspended by their handles(where fitted). Design Life&Approvals Vent valves EUROBAT Classification:Standard Commercial 3 to 5 years Each cell is fitted with a low pressure release valve to allow Yuasa design life at 20°C(yrs) up to 5 gasses to escape and then reseal. VdS(Germany) VdS No:G189170 Gas release VRLA batteries release hydrogen gas which can form explosive mixtures in the air.Do not place inside a sealed container. Recycling YUASA's VRLA batteries must be recycled at the end of life in accordance with local and national laws and regulations. Data Sheet generated on 07/07/2021 -E&OE r' 9 The world's leading battery manufacturer www. uasaeuro e.com Y p YUASA Fire Alarm Systems FPA-1000 Analog Addressable Fire Panels FPA-1000 Analog Addressable Fire Panels www.boschsecurity.com / BoscH Invented for life • U H ► Support for up to 508 points on two analog m n addressable loops �'°°° ► Built-in Ethernet connector for web-browser based programming and Conettix Alarm-over-IP communication ► Two on-board NACs and dual-line PSTN DACT ► Peer-to-peer networking of up to eight-V2 panels in a single group ► Suited to a wide range of applications and compatible with the latest Bosch solutions - including 440 Series Multi-criteria detectors The FPA-1000 Analog Addressable Fire Panels are a expandable with the FPE-1000-SLC Signaling Line scalable solution for fire detection. Protect your small Circuit Plug-in Module, doubling the address points to office with a single system or connect multiple panels 508. together as your needs grow. Networking capabilities The panel has a compact and solid metal housing with support the monitoring of up to 8 interconnected a keyed lock and a removable dead front door to panels (2,000 addressable points) in one system for access electronics. It features surface and semi-flush campuses or other large commercial environments. mounting options. On the front of the panel, six light- The FPA-1000 panels combine complete built-in Fire emitting diodes (LEDs) show Fire, Carbon Monoxide Alarm Control Panel (FACP) equipment such as (Gas) Alarm, Power, Supervisory, Silenced, and Notification Appliance Circuits (NACs), Signaling Line Trouble conditions. The built-in keypad can be used Circuits (SLCs), relays, power supply, Digital Alarm for total system control and programming even when Communicator Transmitter (DACT), and Ethernet wearing fireman gloves. In addition, a large 4-line by connection with expandability using the option bus or 20-character alphanumeric LCD display shows plug-in boards. The two integrated NACs can be programmed device point information. Four keys expanded with remote addressable NAC power enable Drill, Reset, Silence, and Acknowledge boosters and programmed with specific activation functions. patterns. The FPA-1000 panels enable various programming The control panel includes one SLC that supports 254 approaches: addressable points (254 analog detectors or modules, • Front panel programming or 127 analog sounder bases in combination with a • On-site programming, using a laptop with the suitable detector). The control panel is easily possibility of pre-programming at the office • Off-site programming, with remote access via Ethernet (browser-based) 2 I FPA-1000 Analog Addressable Fire Panels Front panel programming provides an auto-learn Communications function, allowing the installer to configure the system The FPA-1000 panels have a dual phone line PSTN/ quickly and easily in default mode. Using a local laptop DACT circuit and an Ethernet connection featuring or remote access communication, the programming is Conettix IP reporting. The panels communicate in carried out by means of a browser-based user Contact ID, SIA, and Modem I1la2. The panels provide interface. Therefore, no software installation is miscellaneous reporting functions such as dialing required. The panel can receive diagnostics from a control and transmission supervision, priorities of Web browser running on an internet-connected PC. report groups, routing to destinations, manual and auto test reports, and Anti-Replay feature. System overview For the primary and secondary account, the following features are programmable: • Two different phone or IP numbers -Option Bus\ • Different dialing types for PSTN (pulse only, FAA 44e0 4,' FAP-440 am„- FMR1000-RCMD\ D �"`yH Smokes�y^A^' • automatic, or tone only) i,D323A,D326A, FAH-440 C.•FAA-325 Eases it , • Individual PSTN line supervision (audible and visual FMR-1°°°.RA FAA-326-86S trouble signal in the case of a transmission path ®n D7030)(Family D326A. _ 1D322A, DAP3'2'r FLM32514 failure) ®D7032 FAH325 Family FLM325.214i! • Selectable options for Report Steering Groups FAP-325-V2F D324A;� IN D7035/E 'I / FAI-325 FLM-32-1M • Programmable supervision time for each IP reporting D331A,D332A, D334A,5-IM� D323A-DH, Conettix account __ FAD-325 Ducts FLM-325-ISD / D35A. • Test report frequency individually programmable for FAD 325-V2F FLM325N4 �' Family Family each account (4, 6, 24 hour, 7 and 28 day intervals, FPP RNAD-8A2 I'� =. D328A0/ standard frequency 24 hour) 'IP FLM-3252R4 FMM325 Family / / \Family FLM-325-CZM4Ili Applications SLC 1/' The panels are recommended for a wide range of NETWORK commercial and public building applications, including: SLC 2 -- F220Family • Retail -single building applications CARDS ° M FPE1000NE FPE-1000-SLC y, ^'^ • Education -schools and universities II PL-10°°NF D2EOFamily • Residential apartment buildings FPE-1000-NW NACs--------\ "• • Commercial - manufacturing plants, warehouses and ms. -D25`m' office complexes — • Government and Public Service- military bases and ® ® ,� installations /0526(]Ah).D1213(5BBliI 'CITY TIE • Medical - healthcare facilities D1224(24 Ah),D 1238(38 Ah) FPE-1000 CITY �EATS 40 Multi-criteria Detectors EATEEo A range of pull stations, modules, accessories and detectors are available to meet the needs of your Functions application. These include the new Automatic Fire Detector 440 family that incorporates multi-criteria Peer-to-peer Communications technology for higher sensitivity, faster detection, and The FPA-1000-V2 panels allow peer-to-peer networking fewer false alarms. of up to eight panels in a single group supporting a system which can include up to 2000 points. Gas detection Networked panels act as a single panel enabling all Integrated gas detection is an important element of events to be displayed on all units. All connected your facility's fire and life safety strategy. Using panels can easily be programmed and controlled via FCC-380 Carbon Monoxide detectors combined with any connected panel. an addressable monitor module, you can set your Ethernet, fiber optic, or 2-conductor wire inter panel system to alarm for carbon monoxide to meet the connections can be mixed providing flexibility in NFPA requirements for visual and audible annunciation system design. for this hazardous gas. System Management Notification Appliance Circuits (NACs) A set of interactive Web pages gives you an instant Two Class A or Class B NACs provide up to 4 A of 24 V means to access and record important system power (non synchronized: 2.5 A per NAC, functions. This unique feature enables programming synchronized: 2.75 A NAC 1 + NAC 2 in total) to and diagnostic capabilities while off-site, streamlining operate horns, strobes, bells, and other notification installation and reducing the time required for appliances. Each NAC can be programmed to provide servicing the system. And, you can check status and Temporal Code 4, Temporal Code 3, and steady, manage the system from virtually anywhere on the pulsing, and synchronized protocol output for network. Wheelock, Gentex, and System Sensor notification appliances. 3 I FPA-1000 Analog Addressable Fire Panels On-board Relays Signaling Line Circuits (SLCs) Three programmable on-board relays default to global The panels communicate with each of the analog alarm (zone 226), global system trouble (zone 227), addressable devices located on the SLCs. The SLCs and global system supervisory (zone 228). They can be allow the use of standard non-twisted, non-shielded programmed to activate on a variety of conditions wiring. Each panel supports two Class B circuits or including gas alarm. one Class X circuit or one Class A circuit per SLC. Option Bus Certifications and approvals On the Option Bus, the panels support up to: • eight FMR-1000-RCMD Remote Command Centers Region Regulatory com liance /quality marks and FMR-1000-RA Remote Annunciators in any combination USA UL FSZI.S1871:Emergency Alarm System • eight D7030X Series LED Annunciators with eight LED Control Units(ANSI/UL 2017);UOJZ: Control Units,System(ANSI/UL 864) zones each • eight D7030X Series/D7032 combinations CSFM see www.boschsecurity.com(the Bosch • two Octal Relay Modules or Octal Driver Modules website) • four FPP-RNAC-8A-4C Remote Notification Appliance HAY- 6101 Circuit Power Supplies CoA The outputs of the Octal Relay Modules or Octal Driver Modules are fully programmable, and can be activated Installation/configuration notes by system events. These outputs have the same programming options as the local relays. Each output operates independently of the other seven to provide A WARNING complete flexibility. Communication with the D7035/B This product can expose you to chemicals including or D7048 is supervised. lead, which is known to the State of California to cause cancer and birth defects or other reproductive Power harm. For more information go to: A transformer working with 120 VAC or 240 VAC is www.P65Warnings.ca.gov. supplied standard with the control panel. Two backup batteries with 7 Ah to 18 Ah each fit inside the fire Mounting Considerations panel cabinet. A separate battery box can provide The cabinet can be either semi-flush (requires optional higher capacity. An automated battery calculator sheet FPM-1000-SFMK Semi-flush Mounting Kit) or surface is available online to aid in battery selection and mounted. submittal paperwork. Depending on the configuration and the battery The panels provide two auxiliary power supplies (one selection, the FPA-1000 can be heavy. When attaching FWR and one DC) with 0.5 A at 24 V each, with the enclosure to a surface, use mounting hardware switchable AUX/RST. This auxiliary power can run (not supplied) capable of supporting this weight, and expansion boards or other low current auxiliary reinforce the wall as necessary. devices. Wiring Considerations For installations requiring battery capacity higher than The length of wire allowed between the control panel 40 Ah, a regulated and UL1481 Listed external power and the last device on a wiring run depends on the supply can be used. The external power supply current drawn on that wiring run. Reducing the connects through the panel's battery terminals and is number of devices on a wiring run allows the supervised for AC and battery fault by an input module individual runs to be longer. on the SLC. If not otherwise specified, use wire gauge 12 AWG to The FPP-RNAC-8A-4C Remote NAC Booster adds four 18 AWG (ISO 4 mm2 to 0.75 mm2). additional Notification Appliance Circuits (NFPA 72, Class A or Class B) to the fire panel or serves as a • Notice power supply for fire protective signaling systems. 1 This regulated power supply provides up to 8 A of Shared cable is not recommended for the Option Bus, addressable-points bus,telephone, or NAC power that is used to recharge batteries and operate wiring. Do not run wiring for NAC, Option Bus, continuous and intermittent alarm loads. This 8 A of and SLC in the same conduit.Avoid shielded or power can be distributed through the four NAC Power twisted-pair wire except for network connections Supply circuits that are part of the FPP-RNAC-8A-4C. and special applications where a reduced length The FPP-RNAC-8A-4C is UL Listed for use in of wiring (roughly 50%) is acceptable for commercial fire alarm applications. tolerating a harsh electrical environment. Point Capacity/Configuration Each FPA-1000-V2 panel supports up to 508 addresses, 254 per loop. All compatible detectors and modules are addressed using the D5070 Programmer. 4 I FPA-1000 Analog Addressable Fire Panels You can use addresses 1 to 127 for any combination of Power supply(secondary)with battery backup detectors and modules. SLC devices that support the POWER SONIC:PS-1270, newest DCP protocol version 2.0 can use addresses 1 PS-12170,PS-12180 to 254. For a listing of devices that can use addresses YUASA:NP7-12,NPG18-12 up to 254, see the SLC Address Assignment section of - the FPA-1000 Installation and Operation Guide. • Maintenance Replace batteries when they fail the Detectors connected to a sounder base can use only Battery Load test addresses 1 to 127. The sounder bases are addressed automatically by the panel, depending on the [_AuxiliarY power supply detector's address (detector address +127). AUX/FWR Full Wave Rectified 500 mA at 24 V FWR(17 to Technical specifications 31 VRMS),non switched,power limited,unfiltered, Electrical non-supervised Mains power supply(primary) AUX/RST Resettable 500 mA at 24 V FWR(17 to 31 VDC),switched,power- • Supervision Supervised for the presence of AC limited,filtered,non-supervised power - Line impedance for ground fault 15 kfl • Voltage 120 VAC,60 Hz,1.1 A maximum, detection(Option Bus,SLC,NAC, or secondary power circuit,City Tie/ 240 VAC,50 Hz,0.6 A maximum Local Energy,AUX) Power supply(secondary)with battery backup Option Bus(OB) • Voltage 24 VDC Voltage Nominal 12 VDC,power-limited, • Supervision Supervised for the presence of AC supervised power Current 500 mA maximum • Current consumption 1.25 A maximum Configuration 1 Class B (standby) Circuit wiring distance 4000ft.(1219m)maximum, • Current consumption 5 A maximum depending on wire gage and (alarm) 1.0 A maximum shared between connected devices panel and SLC(s) • Panel<_250 mA 'Notification appliance circuits(NACs) • SLC 1=60 mA/card +220 mA/loop maximum Mainboard NACs Two(NAC 1 and NAC 2) • SLC 2=60 mA/card NAC power from panel Nominal 24 V FWR(17 to +220 mA/loop maximum 4.0 A maximum shared between 31 VRMS),regulated,power NACs,Option Bus,and AUX power limited,supervised • NACs(non synchronized) 2.5 A per NAC,maximum current • NAC 1=2.5 A maximum limited to overall 4.0 A shared • NAC 2=2.5 A maximum among AUX power,Option BUS, • NACs(synchronized) and NACs • NAC 1+NAC 2 in total= ' Line impedance 1.45 fl maximum 2.75 A maximum - • Option Bus=0.5 A Configuration Two Class B or two Class A maximum - • AUX/FWR=0.5 A maximum Signaling line circuits(SLCs) • AUX/RST==0.5 A maximum Voltage Nominal 39 VDC(29 VDC to 40 VDC),power-limited, • Battery capacity 7.0 Ah minimum,40 Ah maximum supervised • Charge current 2.0 A maximum Current 204 mA(per FPE-1000-SLC) • Fuse 15 A blade-type Circuit resistance <50 0 • Suitable battery type Two 12 VDC in series(7 Ah or 18 Ah'U Circuit capacitance <1 OF in enclosure,24 Ah or 38 Ah in additional battery box) Recommended Manufacturers: 5 I FPA-1000 Analog Addressable Fire Panels Signaling line circuits(SLCs) FPA-1000-LC Fire panel, 2 SLC & networking, no encl. Circuit inductance <1 mH FPA-1000-UL Mainboard for use as a replacement board for system update or repair Configuration 1 or 2 Class B or 1 Class A or 1 Order number FPA-1000-LC Class X FPA-1000-LT Analog/networkable panel, no trans- City Tie former FPA-1000-V2 fire panel without transformer. For Latin Circuit resistance 65 0 maximum America only. Order number FPA-1000-LT Wire gauge 12 AWG to 18 AWG(ISO 4 mmz to 0.75 mm2) City Tie-Local Energy Mode Type of connection In series Alarm,trip coil 24 VDC Alarm current 250 mA DC(momentary) Supervisory/standby current <50 mA DC Trip coil resistance 14.5 0 Nominal coil voltage 3.65 VDC,power-limited, supervised City Tie-Reverse Polarity Module Nominal voltage Nominal 24 VDC(26.4 VDC maximum),power-limited, supervised Output current 33 mA maximum Supervisory/standby current 5 mA Networking cards Current(per card) FPE-1000-NE:100 mA FPE-1000-NF:170 mA FPE-1000-NW:330 mA Circuit wiring distance(actual FPE-1000-NE:328 ft.(100 m) length depends on connector FPE-1000-NF:6560 ft. quality) (2000 m)or 10 db loss FPE-1000-NW:3280 ft. (1000 m)maximum Trademarks All hardware/software product names used in this document are likely to be registered trademarks and must be treated accordingly. Ordering information FPA-1000-V2 Fire panel, 2 SLC & networking Advanced analog control panel listed by UL for central station, local, auxiliary, and remote station systems with networking capabilities allowing monitoring of up to 2,000 addressable points in one system. Order number FPA-1000-V2 6 I FPA-1000 Analog Addressable Fire Panels Accessories FAA-325-B4 Analog sensor base, 4" BATB-40 Battery box/enclosure, 22x20.75x7.25" Is combined with analog addressable detectors that 22 x 20.75 x 7.25" (56 x 53 x 18.5 cm). Holds two dry use the advanced digital communication protocol to or wet cell batteries. Optional BATB-SHELF battery provide early fire warning for life safety and property shelf increases number of batteries. Suitable for protection residential/commercial fire or burglary applications. Order number FAA-325-B4 Order number BATB-40 FAA-325-B6 Analog sensor base, 6" BATB-80 Battery box/enclosure, 14x20.75x7.25" 6-inch (152.4 mm) base for FAH-325, FAI-325, and 14 x 20.75 x 7.25" (36 x 53 x 18.5 cm). Battery box/ FAP-325 sensors. US sales only enclosure with shelf holds up to four dry or wet cell Order number FAA-325-B6 batteries. Suitable for residential/commercial fire or burglary applications. FAA-325-B6S Analog sensor base with sounder, 6" Order number BATB-80 Contains an addressable sounder which provides an audible alarm in the immediate vicinity and only works D102 Replacement key for D101 lock set in combination with one of the FAH-325, FAI-325, or The D102 is a replacement key for locks stamped with FAP-325 analog sensors 1358. Order number FAA-325-B6S Order number D102 FAA-440-B4 Analog standard base, 4" D5070 Analog point programmer, hand-held Standard 4-inch base. Used in combination with Used to program address settings on FAP-440 and FAH-440 detectors to provide early fire EEPROM-programmable analog devices warning for life safety and property protection. Order number D5070 Order number FAA-440-B4 D7030X Annunciator, 8 alarm LED FAA-440-B4-ISO Analog isolator base, 4" Eight zone LEDs indicate alarm conditions. 4-inch base with built-in isolator. Used in combination Order number D7030X with FAP-440 and FAH-440 detectors to provide early fire warning for life safety and property protection. D7030X-S2 Annunciator, 8 LED (2 supervisory) Order number FAA-440-B4-ISO Two LEDs indicate supervisory conditions, six indicate alarm conditions. FAA-440-B6 Analog standard base, 6" Order number D7030X-S2 Standard 6-inch base. Used in combination with FAP-440 and FAH-440 detectors to provide early fire D7030X-S8 Annunciator, 8 LED (8 supervisory) warning for life safety and property protection. All eight zone LEDs (yellow) indicate supervisory Order number FAA-440-B6 conditions. Order number D7030X-S8 FAA-440-B6-ISO Analog isolator base, 6" 6-inch base with built-in isolator. Used in combination D7032 Annunciator expander, 8 LED with FAP-440 and FAH-440 detectors to provide early Use with D7030X Family LED annunciators fire warning for life safety and property protection. Order number D7032 Order number FAA-440-B6-ISO D7035 Multiplex octal relay module FAD-325-V2F Kit, analog duct housing w/ smoke head Provide eight Form C relay outputs (w/o enclosure) for Duct detector housing with an FAD-325-V2F-DH Analog the D7024, FPD-7024, or FPA-1000 Fire Alarm Control duct smoke head. It's easy to install with a drill Panels (FACP) template. The steel sampling tube means there are no Order number D7035 screens or filters to clean. D7035B Multiplex octal relay module + enclosure Order number FAD-325-V2F Provide eight Form C relay outputs (with enclosure) FAD-325-V2F-DH Analog duct smoke head, 2-wire 24V for the D7024, FPD 7024, or FPA-1000 Fire Alarm Replacement for the FAD-325-DH Analog duct smoke Control Panels (FACP) head for use in FAD-325, FAD-325-R, FAD-325-V2F and Order number D7035B FAD-325-V2F-R Analog duct kits D7048 Octal driver module, 12V Order number FAD-325-V2F-DH Provides eight open-collector transistor outputs (current sinks) to FPA-1000, FPD-7024, or D7024 FACPs through the control panel's option bus. Order number D7048 7 I FPA-1000 Analog Addressable Fire Panels FAD-325-V2F-R Kit, analog duct housing w/relays & FLM-325-2R4-2A Dual relay module, 2A head Provides 2 A current at two independently-controlled Duct detector housing with an FAD-325-V2F-DH Analog Form C contacts for a variety of Normally Open and duct smoke head and two sets of Form C alarm relays. Normally Closed applications, compatible with 254 It's easy to install with a drill template. The steel addresses sampling tube means there are no screens or filters to Order number FLM-325-2R4-2A clean. Order number FAD 325 V2F R FLM-325-2R4-2A1 Dual relay module with isolator, 2A Provides 2 A current with built-in short circuit isolator FAH-440 Analog heat detector head, fixed/ROR circuitry at two independently-controlled Form C Use with FAA-440 family bases and FAP-1000 Analog contacts for a variety of Normally Open and Normally Addressable Fire Panels to provide general property Closed applications, compatible with 254 addresses protection Order number FLM-325-2R4-2A1 Order number FAH-440 FLM-325-2R4-8A Dual relay module, 8A FAP-325-V2F FAP-325-V2F Analog Photo Detector Flat Provides 8 A current at two independently-controlled Used to detect fast-flaming fires and dense smoke Form C contacts for a variety of Normally Open and typically given off by plastic, foam, paper, wood, and Normally Closed applications, compatible with 254 other materials that tend to smolder addresses Order number FAP-325-V2F Order number FLM-325-2R4-8A FAP-440 Analog photoelectric detector head, 24V FLM-325-2R4-8A1 Dual relay module with isolator, 8A Analog photoelectric smoke detector used with Provides 8 A current with built-in short circuit isolator FAA-440 bases and FAP-1000 fire panels circuitry at two independently-controlled Form C Order number FAP-440 contacts for a variety of Normally Open and Normally FAP-440-T Analog photoelectric detector head, 24V Closed applications, compatible with 254 addresses Analog photo/heat detector used with FAA-440 bases Order number FLM 325 2R4 sAl and FAP-1000 fire panels FLM-325-CZM4 Conventional zone module for Order number FAP-440-T FPA-1000 Enables the FACP to interface and monitor up to 25 FAP-440-TC Analog detector head, photo/heat/CO conventional devices depending on the device type Analog photo/heat/CO detector used with FAA-440 such as two wire smoke detectors or pull stations bases and FAP-1000 fire panels Order number FLM-325-CZM4 Order number FAP-440-TC FLM-325-I4-A Contact monitor, class A, 4" FAP-440-D Analog dual-photoelectric detector head Can be wired for Class A or Class B circuits, mounted Analog dual-photoelectric smoke detector used with to a cover plate for a 4-inch square or double gang FAA-440 bases and FAP-1000 fire panels electrical back box, bi-colored LED provides module Order number FAP 440 D status, compatible with 254 addresses FAP-440-DT Analog detector head, dual, photo/heat Order number FLM-325-I4-A Analog dual photoelectric smoke/heat multi sensor FLM-325-14-Al Contact monitor with isolator class A detector used with FAA-440 bases and FAP-1000 fire 4" panels Can be wired for Class A or Class B circuits, has Order number FAP-440-DT built-in short circuit isolator circuitry, mounted to a FAP-440-DTC Analog detector head, dual, heat/CO cover plate for a 4-inch square or double gang Analog dual-photoelectric smoke/heat multi-criteria electrical back box, bi-colored LED provides module detector used with FAA-440 bases and FAP-1000 fire status, compatible with 254 addresses panels Order number FLM-325-I4-AI Order number FAP 44o DTC FLM-325-IM Contact monitor for mounting in backbox FCC-380 CO detector (Macurco CM-E1) Allows compatible fire alarm control panels (FACP) to Carbon monoxide detector supervise Form A or B dry contact devices in a polling Order number FCC-380 circuit Order number FLM-325-IM FLM-325-2I4 Dual input module for FPA-1000 Provides two independent contact monitoring circuits FLM-325-ISO Short circuit isolator for FPA-1000 to monitor Normally Open (NO) or Normally Closed Isolates a shorted section on a specific polling circuit (NC) dry contact types of fire alarm devices from the rest of the system to minimize the loss of Order number FLM-325-2I4 communication Order number FLM-325-ISO 8 I FPA-1000 Analog Addressable Fire Panels FLM-325-NA4 Supervised output module, Class A/B FPE-1000-NE Network card, 3-Ethernet Can be wired for Class A or Class B circuits, Ethernet Networking Card for peer-to-peer compatible with 254 addresses communication in an FPA-1000-V2 networked system Order number FLM-325-NA4 Order number FPE-1000-NE FLM-325-NAI4 Supervised output module, isolator, FPE-1000-NF Network card, 1-Ethernet 2-fiber optic A/B Fiber Optic Networking Card for peer-to-peer Built-in short circuit isolator circuitry, can be wired for communication in an FPA-1000 networked system Class A or Class B circuits, compatible with 254 Order number FPE-1000-NF addresses Order number FLM 325 NAI4 FPE-1000-NW Network card, 1-Ethernet 2-wired Wired Networking Card for peer-to-peer FMM-325A Analog manual station, single, red communication in an FPA-1000 networked system The single-action manual station is UL listed for Order number FPE-1000-NW commercial fire applications and meets Americans with Disabilities Act (ADA) requirements. Set the FPE 1000 SLC Plug-in SLC module for FPA-1000 address on the polling circuit by programming an Provides a Signaling Line Circuit (SLC) for connection EEPROM microchip with the D5070 Analog point of analog devices to the FPA-1000 Analog Addressable programmer. Fire Panels Order number FMM-325A Order number FPE-1000-SLC FMM-325A-D Analog manual station, double, red FPM-1000-ENC Enclosure with dead-front door The double-action manual station is UL listed for Enclosure with dead front door commercial fire applications and meets Americans Order number FPM 1000 ENC with Disabilities Act (ADA) requirements. Set the FPM-1000-SFMK Semi-flush mounting trim ring address on the polling circuit by programming an The FPM-1000-SFMK Semi-flush Mounting Kit includes EEPROM microchip with the D5070 Analog point a trim ring and 4 screw covers. programmer. Order number FPM-1000-SFMK Order number FMM-325A-D FPP-RNAC-8A-4C Power supply, RNAC 8A 24V FMR-1000-RA LCD annunciator FPA-1000 without When connected to a panel's option bus, the FPP- control RNAC-8A-4C adds four additional NFPA 72, Class B or LCD annunciator without system control capability for Class A NACs. When connected directly to the NAC use with the FPA-1000 Analog Addressable Fire Panels output, it is also a NAC power supply for fire- Order number FMR-1000-RA protective signaling systems. FMR-1000-RCMD LCD annunciator FPA-1000 with Order number FPP-RNAC-8A-4C control LCD annunciator with system control capability for use with FPA-1000 Analog Addressable fire Panels Order number FMR-1000-RCMD FPE-1000-CITY Plug-in city tie module for FPA-1000 Provides the FPA-1000 Analog Addressable Fire Panels with two supervised City Tie Local Energy circuits or Reverse Polarity circuits Order number FPE-1000-CITY Represented by: Europe,Middle East,Africa: Germany: North America: Asia-Pacific: Bosch Security Systems B.V. Bosch Sicherheitssysteme GmbH Bosch Security Systems,Inc. Robert Bosch(SEA)Pte Ltd,Security Systems P.O.Box 80002 Robert-Bosch-Ring 5 130 Perinton Parkway 11 Bishan Street 21 5600 JB Eindhoven,The Netherlands 85630 Grasbrunn Fairport,New York,14450,USA Singapore 573943 Phone:+31 40 2577 284 Germany Phone:+1 800 289 0096 Phone:+65 6571 2808 emea.securitysystems@bosch.com www.boschsecurity.com Fax:+1 585 223 9180 Fax:+65 6571 2699 emea.boschsecurity.com onlinehelp@us.bosch.com apr.securitysystems@bosch.com www.boschsecurity.us www.boschsecurity.asia ©Bosch Security Systems 2019 I Data subject to change without notice 2690096139)en,V24,03.Sep 2019