Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FAI23-0002 040-310-093 29Speedway Record of Completion
Copyright 2018 National Fire Protection Association(NFPA8).Licensed,by agreement,for individual use and download on 0 7/1 81201 8 to Columbus City Of.No other reproduction or transmission in any form permitted without written permission of NFPA®.For inquiries or to report unauthorized use,contact licensing@nfpa.org.This NFCSS All Access subscription expires on September 29,2018. DOCUMENTATION 72-39 SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets,data,or calculations as necessary to provide a complete record. Form Completion Date:6.26.2023 Supplemental Pages Attached: 1 1. PROPERTY INFORMATION Name of property- Tru roots Address: 29 Speedway. Chico CA. 95928 Description of property:_Warehouse Name of property representative:�nlel Address: Phone: Fax-_ E-mail: 2. INSTALLATION,SERVICE,TESTING,AND MONITORING INFORMATION Installation contractor. Eaale Security Systems Address: 2700 Hegan I n #112, Chico, CA, 95928 Phone:530-345-6395 Fax• E-mail: Chico_svc©vyanet_com Service organization.. Eaale Security Systems Address:7ZSE _Hegan I n #112, Chico, CA, 95928 Phone:53Q-345-6395 Fax. E-mail:Chicosvc@vyanet corn Testing organization: Fag le Security Systems Address: 2700 Hegan Ln #112, Chico, CA_ 95928 Phone: 530-345-6395 Fax• E-mail: Effective date for test and inspection contract. Monitoring organization: Vyanet Operatina Group Address:410 SW Columbia St Suite 120, Rend, OR, 97702 Phone:541-941-1Rn0 Fax. E-mail:f hico_svc r!vyanet.com Account number- 31 7/31 8-CO 1 1 Phone line 1- Phone line 2.• Means of transmission- 2 Way Radio Entity to which alarms are retransmitted: Phone. 3. DOCUMENTATION On-site location of the required record documents and site-specific software: 4. DESCRIPTION OF SYSTEM OR SERVICE This is a: New system ®Modification to existing system Permit number: NFPA 72 edition: 2022 4.1 Control Unit Manufacturer- Radionics Model number: 9412GV2 4.2 Software and Firmware Firmware revision number- 7.08 4.3 Alarm Verification This system does not incorporate alarm verification. Number of devices subject to alarm verification- Alarm verification set for seconds ©2015 National Fire Protection Association NFPA 72(p.1 of 3) FIGURE 7.8.2(a) System Record of Completion.(SIC-FUN) 2016 Edition w: Copyright 2018 National Fire Protection Association(NFPA®).Licensed,by agreement,for indi+ridual use and download on 0711812018 to Columbus City Of.No other reproduction or transmission in any form permitted without written permission of NFPA®.For inquiries or to report unauthorized use,contact licensing@nfpe.org.This NFCSS All Access subscription expires on September 29,2018. 72-40 NATIONAL FIRE ALARM AND SIGNALING CODE SYSTEM RECORD OF COMPLETION (continued) 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120 _ Control panel amps: Overcurrent protection: Type:Thermal Amps: 20 Branch circuit disconnecting means location: UPSTAIRS BREAKROOM Number: PANEL L/ BREAKER#7 5.1.2 Secondary Power Type of secondary power: Sealed Lead Acid Location,if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode(hours): In alarm mode(minutes): 5.2 Control Unit This system does not have power extender panels J Power extender panels are listed on supplementary sheet A 6. CIRCUITS AND PATHWAYS Dual Media Separate Survivability Pathway Type Pathway Pathway Class Level Signaling Line I I I B Device Power I I B Initiating Device I I B Notification Appliance I I I B Other(specify): 7. REMOTE ANNUNCIATORS Type Location D1255R Front Entry 8. INITIATING DEVICES Addressable or Alarm or Sensing Type Quantity Conventional Supervisory Technology Manual Pull Stations 2 Conventional Alarm Smoke Detectors 4 Conventional Alarm Photo Duct Smoke Detectors Heat Detectors Gas Detectors Waterflow Switches 5 Conventional Alarm Tamper Switches 7 Conventional Supervisory 2015 National Fire Protection Association NFPA 72(p.2 of 3) FIGURE 7.8.2(a) Continued LJ 2016 Edition Copyright 2018 National Fire Protection Association(NFPA®).Licensed,by agreement,for individual use and download on 07/18/2018 to Columbus City Of.No other reproduction or transmission in any form permitted without written permission of NFPA®.For inquiries or to report unauthonzed use,contact Iicensing@nfpa.org.This NFCSS All Access subscription expires on September 28,2018. DOCUMENTATION 72-41 SYSTEM RECORD OF COMPLETION (continued) 9. NOTIFICATION APPLIANCES Type Quantity Description Audible Visible 3 I Strobe Combination Audible and Visible 5 I Horn/Strobe 10. SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices HVAC Shutdown Fire/Smoke Dampers Door Unlocking Elevator Recall Elevator Shunt Trip 11. INTERCONNECTED SYSTEMS 0 This system does not have interconnected systems. 0 Interconnected systems are listed on supplementary sheet 12. CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as specified herein has been installed according to all NFPA standards cited herein. Signed: "`— Printed name:Nick Ray Date: 6.26.2023 Organization: Eaale S'curity Systems Title:Technician Phone:530-515-0326 12.2 System Operational Test This system as specified herein herein has tested according to all NFPA standards cited herein. Signed:/V Printed name: Nick Ray Date:6.26.2023 Organization: Eaglecurity Systems Title:Technician Phone:530-515-0326 12.3 Acceptance Test Date and time of acceptance test: Installing contractor representative: Testing contractor representative: Property representative: AHJ representative: ©2015 National Fire Protection Association NFPA 72(p.3 of 3) FIGURE 7.8.2(a) Continued l 2016 Edition lynxo Copyright 2018 National Fire Protection Association(NFPA®).Licensed,by agreement,for individual use and download on 0 7/1 812 01 8 to Columbus City Of.No other reproduction or transmission in any form permitted without written permission of NFPA®.For inquiries or to report unauthorized use,contact licensing) nfpa.org,This NFCSS All Access subscription expires on September 29,2018. 72-48 NATIONAL FIRE ALARM AND SIGNALING CODE NOTIFICATION APPLIANCE POWER PANEL SUPPLEMENTARY RECORD OF COMPLETION This form is a supplement to the System Record of Completion.It includes a list of types and locations of notification appliance power extender panels. This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Form Completion Date: 6.26.2023 Number of Supplemental Pages Attached: 1 1. PROPERTY INFORMATION Name of property: Tru roots Inc Address-29 SDeedwav, Chico CA, 95928 2. NOTIFICATION APPLIANCE POWER EXTENDER PANELS Make and Model Location Area Served Power Source Radionics D9142F FACU Warehouse 12 PANEL L/ BREAKER#7 See Main System Record of Completion for additional Information,certifications,and approvals. 02015 National Fire Protection Association NFPA 72 FIGURE 7.8.2(d) Notification Appliance Power Panel Supplementary Record of Completion.(SIG-FUN) ''t 2016 Edition