Loading...
HomeMy WebLinkAboutRiffles RV Park Building 112223 KITCHEN AND BATH AREA140 Yellowstone Drive,Suite 110 •Chico,CA 95973 Phone:(530)809-1315 •Fax:(530)588-9030 www.wg iI berteng i neering.com November 22,2023 Butte County Public Health Department,Environmental Health Division 202 Mira Loma Drive Oroville,CA 95965 Attn: Subject: Dear Nick: Nikolay Ostrovskiy Riffles Resort RV Park Kitchen and Bath Area Building As requested by the RV Park owner,we have evaluated the water usage for the proposed uses in the existing building and computed the capacity of the existing leach field based on a site inspection prepared by Frank Rivera Copies of the site plan prepared by Frank Rivera and the email received from the owner regarding the proposed uses of the existing building are attached.Also attached is a copy of the wastewater calculations for the existing system and the proposed uses. Based upon the existing and proposed uses of the building and my calculations of the estimated flows,it is my opinion that the existing septic system is adequate for the proposed uses in the existing building . Please call this office if you have any questions or need additional information. Sincerely, W.Gilbert Engineering President,W.G.Civil Engineers,Inc. dba W.Gilbert Engineering Cc:Shelly Seidenglanz P:\01 Project Folders\1503 -OWTS Design\0Eng\Correspondence\Riffles RV Park Building 112223.docx Page 1 of2 WASTEWATER CALCULATIONS October 22,2023 4488 Pacific Heights Road,Oroville ExistingSystem: According to the existing leach field system that is connected to the building being converted from a laundry and bathroom facility to a commissary and bathroom facility provided by Frank Rivera consists of four (4),three (3)foot wide by 60-foot-long leach lines. Leach field absorption area =240'times 3'=720 square feet Application rate =0.6 gpd/sf Leach field capacity =720 sf times 0.6 gpd/sf =432 gpd Proposed Building Uses: According to the information supplied by the project owner,the following facilities are proposed for use in the building. Two (2)sinks for hand washing and vegetable washing-15 minutes/day,5 days a week. A triple sink with two (2)faucets -120 minutes/day,2 days a week. The average water usage for kitchen sinks is estimated to be 1.5 gallons/minute. Daily flow from the sinks =(120 mins.plus 30 mins.)times 1.5 gallons/minute =225 gallons per day. The daily flow from the two (2)existing bathrooms consisting of one (1)sink,one (1)shower and one (1)toilet each that are used for RV park patrons is estimated as follows: Sinks =30 min per day times 1.5 gallon/minute =45 gallons/day Showers =60 min per day times 2.5 gallons/minute =150 gallons/day Toilets =20 flushes per day times 1.5 gallons/flushes =30 gallons/day Estimated Daily Flow =225 gallons/day Total Estimated Daily Flow =450 gallons/day P:\01 Project Folders\1503 -OWTS Design\0Eng\Correspondence\Riffles RV Park Building 112223.docx Page 2 of 2 Wesley Gilbert From: Sent: To: Subject: Shelly Seidenglanz <Shelly@hwy70.net> Thursday,October 12,2023 2:33 PM Wesley Gilbert Re:Riffles Resort RV Park Kitchen &Bath Area Correction -This line should read: The other two sinks are a hand washing and a vegetable washing sink that would run for 15 minutes,5 days a week. On Thu,Oct 12,2023 at 2:31 PM Shelly Seidenglanz <Shelly@hwy70.net>wrote: We have a triple sink with two faucets which would only run,at most,5 days a week for 2 hours each day. The other two sinks are a hand washing and a vegetable washing sink that would run for 15 minutes,2 days a week. The adjacent two bathrooms consist of 1 sink,1 shower and 1 toilet each for the campground use.We anticipate 100 campers/month. We would hope to not limit our use if possible. Regards, Shelly Wesley Gilbert From: Sent: To: Subject: Frank Rivera <rivera.contracting@outlook.com > Thursday,October 12,2023 11 :47 AM Wesley Gilbert;Shelly Seidenglanz RE:Riffles Resort RV Park Kitchen &Bath Area The leach trench is 36 inches wide and 24-26 inches deep. Thank you, Rivera Contracting General Contractor ]Farm Labor Contractor P.O.Box,6238;Oroville,CA 95966 rivera.contracting@outlook.com (530)693-0665 From:Wesley Gilbert Sent:Thursday,October 12,2023 11:02 AM To:Frank Rivera;Shelly Seidenglanz Subject:RE:Riffles Resort RV Park Kitchen &Bath Area Thank you for sending me the Site Plan.However,I did not see the leach trench depth and width information. Please forward this information to me,and I will respond to the County appropriately.Thank you. Wesley E.Gilbert,P.E. R.C.E.31689 President,W.G.Civil Engineers,Inc. dba W.Gilbert Engineering 140 Yellowstone Drive,Suite 110 Chico,CA 95973 Phone:(530)809-1315,Ext 1 Direct:(530)588-9934 Mobile:(530)588-4229 wes@wgilbertengineering.com 1 #f- -I-' □□n In LJ□I□□□ :i....,(1)..aE::Jz: ~,n:;a.. U)10U)U)(l}l(J)U)<C 5OO3+L± wore8 dad d73av+,Onc ,s- L31Nl z::ic..wI-.....(./)I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I %8sdcs-9 £ II ,O.. ,-..I a) (1) c::::ro 08..cQ. <dCi\1- (/)<<q:)=7 Z i