HomeMy WebLinkAbout3.ADM24-0005 Site plan4729.3'
1797.7'
210.3'
1701'
2794.8'
1509.3'
3268.8'
2390'
INV
INV
INV
INV
INV
INV
INV
INV
INV
INV
INVINV
INVINV
INV
160.6'
(E) T
385.5'
704'
1610.5'
1531.5'
FARMLAND RESERVES INC.
APN: 047-010-015-000
195 AC.
SITE PLAN NOTES:
1.NO GAS LINES LOCATED ON PARCEL.
2.NO EASEMENTS ON PARCEL AFFECTING SOLAR/PV ARRAY.
3.YEAR ROUND VEGETATION MANAGEMENT SHALL BE
PROVIDED FOR THE SITE.
4.SOLAR PHOTOVOLTAIC PANELS OR MODULES THAT ARE
INDEPENDENT STRUCTURES AND DO NOT HAVE
ACCESSIBLE/OCCUPIED SPACE UNDERNEATH ARE NOT
REQUIRED TO ACCOMMODATE A ROOF PHOTOVOLTAIC LIVE
LOAD, PROVIDED THE AREA UNDER THE STRUCTURE IS
RESTRICTED TO KEEP THE PUBLIC AWAY. ALL OTHER LOADS
AND COMBINATIONS IN ACCORDANCE WITH CBC 1605 SHALL
BE ACCOMMODATED. PER CBC 1607.12.5.3
5.EQUIPMENT LOCATIONS AND CONDUIT RUNS SHOWN ON
THIS PLAN ARE DIAGRAMMATIC ONLY. CONTRACTOR SHALL
VERIFY EXACT CONDUIT PATH AND EQUIPMENT PLACEMENT
BASED ON SITE CONDITIONS AND PHYSICAL
MEASUREMENTS.
N
601 W. GRANGEVILLE BLVD.
HANFORD, CA 93230
(559) 410-8640
LIC# 944636
REV DATE DESCRIPTION PROJECT NAME:
BALLARD 1
ADDRESS:
BALLARD RD. CHICO, CA 95973-9469
POI COORDINATES:
39.877050°, -122.029556°
DESIGNER:
RENEWABLE SOLAR INC.
DATE:
8/18/2023
DRAFTER:
LAURENCE WOMACK
PLOT DATE:
PROJECT NUMBER:
#3152
SHEET SIZE:
24" X 36"
BUTTE COUNTY, CA
SHEET NO.:
SCALE:OVERALL SITE PLAN
PV3.0
1" = 200'
LEGEND:
MAIN AC DISCONNECT(S) WITHIN 10'-0" OF UTILITY METER
N.T.S
EXISTING ELECTRICAL EQUIPMENT N.T.S
DISTRIBUTION PANEL N.T.S
SERVICE CT METER N.T.S
UTILITY TRANSFORMER N.T.S.
(15)TYPICAL INVERTER CHINT POWER SYSTEMS AMERICA
#SCA60KTL-DO/US-480 N.T.S.
(1674)TYPICAL PV MODULE CANADIAN SOLAR, INC.
#CS7N-650MB-AG
EXISTING UTILITY POWER POLE
ROADS AND OTHER BOUNDARIES
PROPERTY LINE
AC
E
T
INV
BALLARD RD.BALLARD RD.SOUTHERN PAC
IF
IC
RA
ILROAD
SACRAMENTO RIVERPROPOSED
NEW SOLAR
FIELD
INVINVINVINVINVINVINVINVINVINVINVINVINVINVINV(E) T400'-8"231'-9"27'104'-3"SITE PLAN NOTES:1.ELECTRICAL UTILITY LINE SHALL BE PROTECTED IN PLACE WHEN POSSIBLE. IF EXISTINGELECTRICAL LINE PRESENTS EXCESSIVE CONSTRAINTS, FIELD CREW TO REMOVE ANDRELOCATE EXISTING LINES AS NEEDED.2.EXISTING ENERGIZED EQUIPMENT THAT COMES INTO CONTACT WITH ANY NEWLY INSTALLSOLAR EQUIPMENT INVOLVED IN THIS SCOPE OF WORK SHALL BE DE-ENERGIZED TO PREVENTANY ELECTRICAL HAZARDS,3.MINIMUM CONDUIT BURIAL DEPTH SHALL BE PER NEC 300.54.ACCESS AND WORKING SPACE SHALL BE PROVIDED AND MAINTAINED ABOUT ELECTRICALEQUIPMENT PER NEC 110.265.SOLAR PHOTOVOLTAIC PANELS OR MODULES THAT ARE INDEPENDENT STRUCTURES AND DONOT HAVE ACCESSIBLE/OCCUPIED SPACE UNDERNEATH ARE NOT REQUIRED TOACCOMMODATE A ROOF PHOTOVOLTAIC LIVE LOAD, PROVIDED THE AREA UNDER THESTRUCTURE IS RESTRICTED TO KEEP THE PUBLIC AWAY. ALL OTHER LOADS ANDCOMBINATIONS IN ACCORDANCE WITH CBC 1605 SHALL BE ACCOMMODATED.6.EQUIPMENT LOCATIONS AND CONDUIT RUNS SHOWN ON THIS PLAN ARE DIAGRAMMATIC ONLY.CONTRACTOR SHALL VERIFY EXACT CONDUIT PATH AND EQUIPMENT PLACEMENT BASED ONSITE CONDITIONS AND PHYSICAL MEASUREMENTS.7.ALL EQUIPMENT AND APPURTENANCES USED IN THIS PROJECT SHALL BE UL (NRTL) LISTEDAND LABELED FOR THE PURPOSE AS PER CEC-2016 ART. 110.3 AND 690.4D8.(9) ROWS OF 2UP X (93) MODULES.NT601 W. GRANGEVILLE BLVD.HANFORD, CA 93230(559) 410-8640LIC# 944636REVDATEDESCRIPTIONPROJECT NAME: BALLARD 1ADDRESS: BALLARD RD. CHICO, CA 95973-9469POI COORDINATES: 39.877050°, -122.029556°DESIGNER: RENEWABLE SOLAR INC.DATE: 8/18/2023DRAFTER: LAURENCE WOMACKPLOT DATE:PROJECT NUMBER: #3152SHEET SIZE: 24" X 36"BUTTE COUNTY, CASHEET NO.: SCALE:ENLARGED SITE PLANPV3.11" = 20'LEGEND:MAIN AC DISCONNECT(S) WITHIN 10'-0" OF UTILITYMETER N.T.SEXISTING ELECTRICAL EQUIPMENT N.T.SDISTRIBUTION PANEL N.T.SSERVICE CT METER N.T.SUTILITY TRANSFORMER N.T.S.(15)TYPICAL INVERTER CHINT POWER SYSTEMSAMERICA #SCA60KTL-DO/US-480 N.T.S.(1674)TYPICAL PV MODULE CANADIAN SOLAR, INC.#CS7N-650MB-AGROADS AND OTHER BOUNDARIESBELOW GRADE CONDUIT RUNPROPERTY LINEACETINVIRR. CANALIRR. CANALEXISTING UTILITY POWER POLE #892NEW SERVICE CT METERAND MAIN SWITCHBOARDRSI TO BORE UNDER CANALDIRECTLY EAST ±100 FT. TO DPDIRT ROADACINSTALL NEW FIREEXTINGUISHER #2A10BCINSTALL NEW FIREEXTINGUISHER #2A10BCINSTALL NEW FIREEXTINGUISHER #2A10BCINSTALL NEW FIREEXTINGUISHER #2A10BCNEW DISTRIBUTION PANEL "DP"