HomeMy WebLinkAboutCF RC2 Butte County Fire Department Plan Check Response Letter dated January 15, 2024 Architecture NORTHSTAR Civil Engineering Planning Surveying January 15, 2024 Butte County Fire Department 176 Nelson Avenue Oroville, CA 95965 RE: Building Permit Number: B22-2052 Plan Check#1 Assessor Parcel Number: 060-060-013 Description: As-Built H2O Storage Tank Building PLAN CHECK#1 RESPONSE Reference September 30,2022 Plan Check#1 (Attached) GENERAL COMMENTS The occupancy classification is changed from S-2 to U (Miscellaneous). It is our understanding that this removes the requirement for 7A materials (exterior). It is acknowledged that the building CANNOT be used for storage or occupancy. 1. Rappelling access and interior climbing wall access have been eliminated. The climbing wall will remain on the exterior of the building but all interior use for climbing will be eliminated.All access openings will be eliminated.See notes on Building Elevations,Sheet 1 of 4(attached).See revised Project Purpose and Building Code Analysis on Sheet 3 of 4. 2. Existing flooring at the second level will be removed to comply with landing requirements at the second level. Refer to Sheet 2 of 4, "Landing Floor Plan". Flooring will be removed to limit the area at this level to less than one-third of the total available area (less than 192 square feet is allowable).This level is then not considered a "floor".This Landing Floor Level will not be used for storage. It will only be used for access to the stairways and to the top of the water tank for maintenance purposes. Existing flooring at the third level will be removed to comply with mezzanine requirements at the third level. Refer to Sheet 2 of 4, "Mezzanine Plan". Flooring will be removed to limit the area at this level to less than one-third of the total available area (less than 192 square feet is allowable).This level is then not considered a"floor".This Mezzanine Level will not be used for storage. It will only be used for access to the stairways and to the top of the water tank for maintenance purposes. In effect,the building becomes a one-story structure. 3. See responses above. Sprinklers are not required. 4. The allowable floor area has been corrected. See revised Project Purpose and Building Code Analysis on Sheet 3 of 4. 5. The Climbing/Rappelling program is covered by BSA standards and requirements. The program must be inspected and approved for use under these standards. The program is NOT currently lit Mission Ranch Blvd . Suite 100. Chico. CA 95926. Phone 530 893 1600. Fax 530 893 21 1 3 info;DNorthStarAE corn l www NorthStarAE corn To: Butte County Fire Department NORTHSTAR RE: Building Permit Number: B22-2052 Plan Check#1 Assessor Parcel Number:060-060-013 Description: As-Built H2O Storage Tank Building Page 2 of 2 BSA certified for use. Note,this program cannot and will not be used prior to reinspection.This is a BSA requirement.When available,inspection documents can be made available to Butte County Fire Department. 6. See#5 above. 7. Reference Sheet 2 of 4, First Floor Plan,for note added regarding fire extinguisher. 8. Refer to Sheet 4 of 4, Site Plan, for "path of travel" to the designated emergency assembly area for the Camp. Please contact me if there are any questions or unresolved items. Thank you for your patience, cooperation, and assistance with this project, NorthStar Mark Adams, PE Cc: James Rodes-Dreyer, BSA Bill Whitton, BSA Jim Thorup Ryan Pickering Eric Chen, Butte County Code Enforcement Attachments: - Revised Building Plans from Mark Adams dated January 2024(Four Pages). 1 1 1 Mission Ranch Blvd . Suite 100. Chico, CA 95926, Phone: 530 893 1600. Fax: 530 893.21 1 3 nfo`c�NorthStarAE com I www NorthStarAE.com