Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
026-090-005 B23-3673 SITE PLANS
462'-7"201'-10"485'-0"201'-6"343'-8"74'-4"112'-3"98'-8"33'-2"DRIVEWAYRAILROAD AVE FRONT OF HOUSE68'-0"8'-0"NCOVER PAGENEW PV SYSTEM SPECIFICATIONSSYSTEM SIZE:DC SIZE: 8.025 KW DC-(STC)CEC AC SIZE: 7.304 KW ACMODULE:(15) JA SOLAR JAM72D30 535/MBINVERTER:(15) ENPHASE IQ8H-240-72-2-US [240V] [SI1-SB]PROJECT NOTES1.1.1 THIS PHOTOVOLTAIC (PV) & ENERGY STORAGE SYSTEMSHALL COMPLY WITH THE RELEVANT YEAR OF THE CALIFORNIAELECTRIC CODE (CEC), ALL MANUFACTURER’S LISTING ANDINSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES ASSPECIFIED BY THE AUTHORITY HAVING JURISDICTION’S (AHJ)APPLICABLE CODES.1.1.2 THE UTILITY INTERCONNECTION APPLICATION MUST BEAPPROVED AND THE PV & ENERGY STORAGE SYSTEM MUST BEINSPECTED PRIOR TO OPERATION1.1.3 ALL PV & ENERGY STORAGE SYSTEM COMPONENTS;MODULES, UTILITY-INTERACTIVE INVERTERS, BATTERIES, ANDSOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTEDFOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY CEC ANDOTHER GOVERNING CODES1.1.4 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCALBUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UVRESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED ASREQUIRED BY THE CEC AND AHJ.NEW PHOTOVOLTAIC GROUND MOUNTED SYSTEM - 8.025 KW DC/7.304 KW CEC AC& ENERGY STORAGE SYSTEM - 10.5 KWH7055 RAILROAD AVE, PALERMO, CA 95968BATTERY:(01) ENCHARGE-10-1P-NA [240V] [SI1-JUN20]BATTERY SIZE:10.5 KWHSCOPE OF WORK1.2.1 CONTRACTOR IS RESPONSIBLE FOR THE DESIGN ANDSPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC & ENERGYSTORAGE SYSTEM. THE CONTRACTOR WILL BE RESPONSIBLEFOR COLLECTION OF EXISTING ONSITE CONDITIONS TO DESIGN,SPECIFY, AND INSTALL THE GROUND-MOUNTED PV SYSTEM ANDENERGY STORAGE SYSTEM DETAILED IN THIS DOCUMENTDESIGN CRITERIAGROUND SNOW LOAD: 0 PSFWIND SPEED: 100 MPHWIND EXPOSURE: CRISK CATEGORY: ISCALE:1"-50'-0"- PROPERTY LINE- FENCE LINELEGENDSATELLITE MAPAPPLICABLE CODESALL WORK SHALL CONFORM TO THE FOLLOWING CODES:2022 CALIFORNIA BUILDING CODE2022 CALIFORNIA RESIDENTIAL CODE2022 CALIFORNIA ENERGY CODE2022 CALIFORNIA HISTORICAL BUILDING CODE2022 CALIFORNIA EXISTING BUILDING CODE2022 CALIFORNIA GREEN BUILDING STANDARDS CODE2022 CALIFORNIA FIRE CODE2022 CALIFORNIA ELECTRICAL CODEAS ADOPTED BY COUNTY OF BUTTEPROPERTY PLANPV-011COVER PAGEPV-01EQUIPMENT DATASHEETS ATTACHEDNOTESSITE PLANELECTRICAL DIAGRAMWARNING LABELSATTACHMENT PLAN & DETAILSINSTALLATION RESOURCESHEET INDEXPV-02PV-03PV-04PV-05PV-06PV-07PV-011/26/2024SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (530) 720-5377LIC. NO. - 1068160REVDATEDESCRIPTIONREVISIONSDC SIZE: 8.025 KW DC-(STC)CEC AC SIZE: 7.304 KW AC(15) JA SOLAR JAM72D30 535/MB(15) ENPHASE IQ8H-240-72-2-US [240V] [SI1-SB](01) ENCHARGE-10-1P-NA [240V] [SI1-JUN20]BATTERY SIZE: 10.5 KWHCONTRACTORPROJECT NAME & ADDRESS3881 BENATAR WAY STE G,CHICO, CA 95928REVAMP SOLAR ENERGYAPN #: 026090005000AHJ: COUNTY OF BUTTEUTILITY: PG&ERON SUMMERS7055 RAILROAD AVE,PALERMO, CA 95968A1/26/2024AHJ CORRECTIONVICINITY MAP(E) MAIN HOUSE(E) GARAGE(E) FENCE(E) SHED(E) PUMP HOUSE(E) SHED(E) SHEDATTACHMENT PLAN & DETAILSPV-03.1EQUIPMENT ELEVATIONPV-03.2LOAD CALCULATIONPV-04.1BATTERY MOUNT DETAILPV-04.2DAIRY LEACHLEACH(E) SHOP (E) MANUFACTURED HOME DERATE MAIN BREAKER FROM 125A TO 100A10' BRUSHFREE AREA80' LEACH LINE 80' LEACH LINE 80' LEACH LINE 100 GAL. SEPTIC TANK 1234ARRAY 18FRONT OF HOUSE56109 78.111NPV-021/26/2024SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (530) 720-5377LIC. NO. - 1068160REVDATEDESCRIPTIONREVISIONSDC SIZE: 8.025 KW DC-(STC)CEC AC SIZE: 7.304 KW AC(15) JA SOLAR JAM72D30 535/MB(15) ENPHASE IQ8H-240-72-2-US [240V] [SI1-SB](01) ENCHARGE-10-1P-NA [240V] [SI1-JUN20]BATTERY SIZE: 10.5 KWHCONTRACTORPROJECT NAME & ADDRESS3881 BENATAR WAY STE G,CHICO, CA 95928REVAMP SOLAR ENERGYAPN #: 026090005000AHJ: COUNTY OF BUTTEUTILITY: PG&ERON SUMMERS7055 RAILROAD AVE,PALERMO, CA 95968A1/26/2024AHJ CORRECTIONSITE PLANSCALE:3/32" = 1'-0"SITE PLANPV-021= FLUE / PLUMBING VENT= MECHANICAL VENTNOTES:1.STRUCTURES, PATIO COVERS, AND/ORADDITIONS BUILT WITHOUT PERMITS TO BERESOLVED BY A SEPARATE PERMIT.TRENCH NOTES:1.18" MINIMUM DEPTH OR BELOW FROST LINE.2.24" MINIMUM DEPTH FOR CONDUITTRENCHED UNDER AREAS SUBJECT TOVEHICLE TRAFFIC.LEGEND44.65"88.96"5(E) UTILITY METER (OVERHEAD SERVICE)METER #: 1007549773870FT TRENCH9ENPHASE IQ BATTERY; WILL BE MOUNTEDAT ARRAY10ENPHASE IQ SYSTEM CONTROLLERENPHASE IQ COMBINER BOX71MICROINVERTER (1 PER MODULE)2(15) JA SOLAR JAM72D30 535/MB MODULES WITHENPHASE IQ8H-240-72-2-US [240V] [SI1-SB] UNDEREACH MODULE(N) JUNCTION BOX (NEMA 3R)36MAIN SERVICE PANELESSENTIAL LOADS PANEL8.14CONDUIT RUN; SURFACE MOUNTED (ACTUALCONDUIT RUNS TO BE DETERMINED IN FIELD)FIRE SETBACKS36" 18"GROUND-MOUNT ARRAY(S)ARRAY SLOPE- 25°AZIMUTH - 180°MODULE QTY.- 15ARRAY 1SCRIM FENCING TO BEINSTALLED UNDER ARRAYSTO PROTECT CONDUCTORS11RAPID SHUTDOWN SWITCHNEW GROUNDINGELECTRODE SYSTEMAAThis item has been digitally signedand sealed on Feb 14, 2024 2' 6"CANTILEVER12' 7"E-W PIER SPACING9' N-S PIER SPACING 30' 1"CROSS PIPE204"RAIL3' 6 "RAIL CANT ILEVER 1' 4"HOLE DIAMETER4' 6"DEPTHHOLE3' 2' 4" 6' 7" 9' 7" 8' 4"CLEARANCENORTH1' 2"CLEARANCESOUTHN-S PIER SPACING9'15' 5"3' 2"25°PV-031/26/2024SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (530) 720-5377LIC. NO. - 1068160REVDATEDESCRIPTIONREVISIONSDC SIZE: 8.025 KW DC-(STC)CEC AC SIZE: 7.304 KW AC(15) JA SOLAR JAM72D30 535/MB(15) ENPHASE IQ8H-240-72-2-US [240V] [SI1-SB](01) ENCHARGE-10-1P-NA [240V] [SI1-JUN20]BATTERY SIZE: 10.5 KWHCONTRACTORPROJECT NAME & ADDRESS3881 BENATAR WAY STE G,CHICO, CA 95928REVAMP SOLAR ENERGYAPN #: 026090005000AHJ: COUNTY OF BUTTEUTILITY: PG&ERON SUMMERS7055 RAILROAD AVE,PALERMO, CA 95968A1/26/2024AHJ CORRECTIONATTACHMENT PLAN& DETAILSScale: NTSSIDE VIEWPV-032Scale: NTSTOP VIEWPV-031NOTE:1.PLEASE REFER TO MANUFACTURER RACKING REPORT ATTACHED TO ENDOF PLAN SET FOR MORE DETAILS REGARDING GROUND MOUNT RACKING2.GRADING TO BE VERIFIED TO MATCH SPECIFICATIONS OF MANUFACTURERRACKING REPORTPOINT LOAD CALCULATIONSMODULE TYPEJA SOLAR JAM72D30 535/MBMODULE WEIGHT69.66 LBSNUMBER OF MODULES15TYPE OF RACKINGIRONRIDGE XR-1000SOIL TYPE: 2 - Sedimentary and folliated rockANCHORING STRATEGY: CONCRETEPIER DEPTH: 3'-0"NUMBER OF PIERS: 6CROSS-BRACING: NOEAST\WEST SPAN: MAX:12'-7"EAST\WEST CANTILEVER: 2'-6"NORTH\SOUTH SPAN: MAX. 9'-0"MODULE COUNT AND TYPE: (15) JA SOLAR JAM72D30 535/MBARRAY COLUMNS: 04ARRAY ROWS: 04ARRAY TILT: 25°ARRAY AZIMUTH: 180°WIND DESIGN SPEED:100 MPHEXPOSURE CATEGORY = CRISK CATEGORY = IGROUND SNOW LOAD: 0 PSFThis item has been digitally signedand sealed on Feb 14, 2024 PV MODULE FRAMEIRON RIDGE RAILDETAIL, END CLAMP FRONTScale: 6" = 1'-0"HIRON RIDGE STOPPER SLEEVEIRON RIDGE UNIVERSALFASTENING OBJECTIRON RIDGE STOPPERSLEEVEPV MODULE FRAMEIRON RIDGE RAILDETAIL, END CLAMP PLANScale: 6" = 1'-0"GIRON RIDGE UNIVERSALFASTENING OBJECTIRON RIDGE UNIVERSALFASTENING OBJECTPV MODULE FRAMEIRON RIDGE RAILDETAIL, MID CLAMP FRONTScale: 6" = 1'-0"FPV MODULE FRAMEDETAIL, MID CLAMP PLANScale: 6" = 1'-0"EIRON RIDGE UNIVERSALFASTENING OBJECT3" PIPEIRONRIDGE3" TOP CAPIRONRIDGEXR RAILPV MODULE,BY OTHERSIRONRIDGE3" RAILCONNECTORScale: 3" = 1'-0"CPIPE FITTINGS DETAIL3" PIPEIRON RIDGE3" TOP CAPXR100 RAILPV MODULE,BY OTHERSIRON RIDGE3" RAILCONNECTORScale: 3" = 1'-0"DPIPE FITTINGS DETAILIRON RIDGE UNIVERSALFASTENING OBJECTPV-03.11/26/2024SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (530) 720-5377LIC. NO. - 1068160REVDATEDESCRIPTIONREVISIONSDC SIZE: 8.025 KW DC-(STC)CEC AC SIZE: 7.304 KW AC(15) JA SOLAR JAM72D30 535/MB(15) ENPHASE IQ8H-240-72-2-US [240V] [SI1-SB](01) ENCHARGE-10-1P-NA [240V] [SI1-JUN20]BATTERY SIZE: 10.5 KWHCONTRACTORPROJECT NAME & ADDRESS3881 BENATAR WAY STE G,CHICO, CA 95928REVAMP SOLAR ENERGYAPN #: 026090005000AHJ: COUNTY OF BUTTEUTILITY: PG&ERON SUMMERS7055 RAILROAD AVE,PALERMO, CA 95968A1/26/2024AHJ CORRECTIONATTACHMENT PLAN& DETAILSThis item has been digitally signedand sealed on Feb 14, 2024 TO MSPFROM ENPHASEIQ SYSTEMCONTROLLER 2FROM PVFROM UTILITYSOUTH WALL OF THE HOUSE(OUTSIDE)NORTH OF THE GROUND ARRAYTO BACKUPLOAD PANELFROM ENPHASEIQ SYSTEMCONTROLLER 2PV-03.21/26/2024SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (530) 720-5377LIC. NO. - 1068160REVDATEDESCRIPTIONREVISIONSDC SIZE: 8.025 KW DC-(STC)CEC AC SIZE: 7.304 KW AC(15) JA SOLAR JAM72D30 535/MB(15) ENPHASE IQ8H-240-72-2-US [240V] [SI1-SB](01) ENCHARGE-10-1P-NA [240V] [SI1-JUN20]BATTERY SIZE: 10.5 KWHCONTRACTORPROJECT NAME & ADDRESS3881 BENATAR WAY STE G,CHICO, CA 95928REVAMP SOLAR ENERGYAPN #: 026090005000AHJ: COUNTY OF BUTTEUTILITY: PG&ERON SUMMERS7055 RAILROAD AVE,PALERMO, CA 95968A1/26/2024AHJ CORRECTIONEQUIPMENT ELEVATIONSCALE:NTSEQUIPMENT ELEVATIONPV-03.21(N) ENPHASE IQ SYSTEMCONTROLLER 2GRADE(N) ENCHARGE-10-1P-NA [240V][SI1-JUN20] BATTERY(E) UTILITY METER(OVERHEAD SERVICE)METER #: 1007549773(N) ENPHASE COMBINER PANEL(E) MAIN SERVICE PANEL(N) BACKUP LOADPANEL(N) RAPID SHUTDOWN SWITCH TRENCHEDCONDUIT3GN20A/2P(N) ENPHASE COMBINER PANELNEMA 3R, UL LISTED,125A RATED20A/2PENPHASE QCABLE(S)JA SOLAR JAM72D30 535/MB08 MICROINVERTERS IN STRING 107 MICROINVERTERS IN STRING 21(N) JUNCTION BOX600 V, NEMA 3RUL LISTEDENPHASE IQ8H-240-72-2-US[240V] [SI1-SB] MICROINVERTERSONE UNDER EACH PANEL (240V)L2L1L2L1G#6 AWG BARE CUROMEX CAN BE USED IN LIEU OF CONDUIT FORINTERIOR BUILDING AND ATTIC RUNS ONLY. DO NOTUSE ROMEX IN CONDUIT OR OUTDOOR ENVIRONMENTS.2(ENPHASE X-IQ-AM1-240-4/4C)METER #: 1007549773(E) BI-DIRECTIONALUTILITY METER1-PHASE, 3-W,120V/240VLOAD SIDEINTERCONNECTIONAT MAIN PANEL(N) 100A/2P MAINBREAKER, 240VL2GMN(E) 125A MAINSERVICE PANEL,240VNL1TO UTILITY GRID(N) 50A/2PLINELOADEXISTING GROUNDINGELECTRODE SYSTEMGECAC ~DC ±BATTERY+-L2L1GL2L1G(N) ENPHASEENCHARGE-10-1P-NA[240V] [SI1-JUN20]BATTERY(2) #10 AWG THWN-2(1) #8 AWG THWN-2 GRND3/4" EMT CONDUITGN(N) 50A/2PMAIN BREAKER(N) 125A BACKUPLOADS PANEL,NEMA 3R, 120/240V,1-PHASEGN30A/2P20A/2P40A/2P200A FACTORY WIRINGNFT (AUTOTRANSFORMER)AC COMBINERIQ BATTERYGENERATORIQ BATTERYIQ COMBINER(N) ENPHASE SYSTEM CONTROLLER 2200A, NEMA 3R, 120/240VN/C3N/C4WIRELESSCOMMS4TRENCHEDCONDUITPOINT OF INTERCONNECTIONPV HOLD DOWNKIT BRHDK125 ISREQUIRED PERNEC 705.15CONSUMPTION CTsTO IQGATEWAYIQ GATEWAY/GENERATORIQ GATEWAYCELLMODEMWIRELESSCOMMS15A/2PESS HOLD DOWNKIT BRHDK125 ISREQUIRED PERNEC 705.15(N) ENPHASERAPIDSHUTDOWNSWITCH(4) #12 AWG THWN-2(1) 3/4" EMT CONDUITUL RING TERMINAL(N) SURGEPROTECTIONDEVICEPV-041/26/2024SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (530) 720-5377LIC. NO. - 1068160REVDATEDESCRIPTIONREVISIONSDC SIZE: 8.025 KW DC-(STC)CEC AC SIZE: 7.304 KW AC(15) JA SOLAR JAM72D30 535/MB(15) ENPHASE IQ8H-240-72-2-US [240V] [SI1-SB](01) ENCHARGE-10-1P-NA [240V] [SI1-JUN20]BATTERY SIZE: 10.5 KWHCONTRACTORPROJECT NAME & ADDRESS3881 BENATAR WAY STE G,CHICO, CA 95928REVAMP SOLAR ENERGYAPN #: 026090005000AHJ: COUNTY OF BUTTEUTILITY: PG&ERON SUMMERS7055 RAILROAD AVE,PALERMO, CA 95968A1/26/2024AHJ CORRECTIONELECTRICALDIAGRAMMICROINVERTER SPECIFICATIONSMANUFACTURER / MODEL #ENPHASE IQ8H-240-72-2-US [240V][SI1-SB]INPUT POWER RANGE320W-540WMIN/MAX START VOLTAGE22V/58VNOMINAL AC VOLTAGE240VMAX CONT. OUTPUT CURRENT1.58AMAX CONT. OUTPUT POWER380WMAX MODULES PER STRING10 (10 MICROINVERTERS)AMBIENT TEMPERATURE SPECIFICATIONSRECORD LOW TEMP-3°CAMBIENT TEMP (HIGH TEMP 2% AVG.)38°CMINIMUM CONDUIT HEIGHT ABOVE ROOF SURFACE7/8"SOLAR MODULE SPECIFICATIONSMANUFACTURER / MODEL #JA SOLAR JAM72D30 535/MBVMPIMPVOCISCTEMP. COEFF. VOC41.47V12.90A49.45V13.79A-0.275%/°CWIRE IDEXPECTEDWIRE TEMP (°C)TEMPDERATE(90 °C)QTY OF CURRENTCARRYINGCONDUCTORSCONDUITFILL DERATEMINIMUMCONDUIT SIZE(TBD ON SITE)WIRE GAUGE &TYPECONDUCTORAMPACITY @90°C (A)CONDUCTORAMPACITY @75°C (A)REQUIRED CIRCUITCONDUCTORAMPACITY (A)ADJUSTEDCONDUCTORAMPACITY @ 90 °C (A)NEUTRALCONDUCTORSIZE & TYPEGROUND WIRESIZE & TYPE1380.9140.83/4" METAL#10 THWN-2403515.8029.12NONE#8 THWN-22380.91213/4" METAL#10 THWN-2403529.6336.40#10 THWN-2#8 THWN-23380.91211" PVC#8 THWN-2555049.6350.05#8 THWN-2#8 THWN-24380.91211" PVC#8 THWN-2555050.0050.05#8 THWN-2#8 THWN-2DESCRIPTIONFORMULARESULTPV + ESS OVERCURRENT PROTECTION CEC 690.9(B) TOTAL INVERTER + ESS OUTPUT CURRENT x 1.25 = ((15 x 1.58) + (01 x 16))A x 1.2549.63A (SELECTED OCP RATING = 50A)120% RULE FOR BACKFEED BREAKER CEC 705.12BUS BAR RATING x 1.2 - MCB RATING = MAX ALLOWABLE PV BREAKER 125A x 1.2 - 100A = 50ASELECTED PV BREAKER <= MAX ALLOWABLE PV BREAKER50A <= 50AESS ENERGY CAPACITY SHALL BE SIZED TOSUPPLY ALL DESIRED LOADS DURING ANOUTAGE. POWER CAPACITY OF THE ESS SHALLBE CAPABLE OF SUPPLYING THE LARGEST LOADON SITE, PER 2017 CEC 710.15(A) & CEC710.15(E)THE MAIN SERVICE BREAKER HASBEEN DOWNSIZED TO 100A. NOUP-SIZING IS PERMITTEDPRODUCERS STORAGE DEVICE(S) WILL NOT CAUSE THE HOST LOAD TO EXCEEDITS NORMAL PEAK DEMAND. NORMAL PEAK DEMAND IS DEFINED AS THEHIGHEST AMOUNT OF POWER REQUIRED FROM THE DISTRIBUTION SYSTEM BYPRODUCERS COMPLETE FACILITIES WITHOUT THE INFLUENCE OR USE OF THEENERGY STORAGE DEVICE(S)."BATTERY TO BE LOCATEDWITHIN 5' OF CONTROLLER"ATTENTION:-TO PREVENT COMPLICATION BE SURE TOPOWER DOWN SYSTEM CONTROLLER 2 BEFORECONNECTING THE SHUTDOWN SWITCHNEW GROUNDINGELECTRODE SYSTEMAAAA LOADCALCULATIONPV-04.11/26/2024SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (530) 720-5377LIC. NO. - 1068160REVDATEDESCRIPTIONREVISIONSDC SIZE: 8.025 KW DC-(STC)CEC AC SIZE: 7.304 KW AC(15) JA SOLAR JAM72D30 535/MB(15) ENPHASE IQ8H-240-72-2-US [240V] [SI1-SB](01) ENCHARGE-10-1P-NA [240V] [SI1-JUN20]BATTERY SIZE: 10.5 KWHCONTRACTORPROJECT NAME & ADDRESS3881 BENATAR WAY STE G,CHICO, CA 95928REVAMP SOLAR ENERGYAPN #: 026090005000AHJ: COUNTY OF BUTTEUTILITY: PG&ERON SUMMERS7055 RAILROAD AVE,PALERMO, CA 95968A1/26/2024AHJ CORRECTION BATTERYMOUNT DETAILPV-04.21/26/2024SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (530) 720-5377LIC. NO. - 1068160REVDATEDESCRIPTIONREVISIONSDC SIZE: 8.025 KW DC-(STC)CEC AC SIZE: 7.304 KW AC(15) JA SOLAR JAM72D30 535/MB(15) ENPHASE IQ8H-240-72-2-US [240V] [SI1-SB](01) ENCHARGE-10-1P-NA [240V] [SI1-JUN20]BATTERY SIZE: 10.5 KWHCONTRACTORPROJECT NAME & ADDRESS3881 BENATAR WAY STE G,CHICO, CA 95928REVAMP SOLAR ENERGYAPN #: 026090005000AHJ: COUNTY OF BUTTEUTILITY: PG&ERON SUMMERS7055 RAILROAD AVE,PALERMO, CA 95968A1/26/2024AHJ CORRECTION PV-051/26/2024SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (530) 720-5377LIC. NO. - 1068160REVDATEDESCRIPTIONREVISIONSDC SIZE: 8.025 KW DC-(STC)CEC AC SIZE: 7.304 KW AC(15) JA SOLAR JAM72D30 535/MB(15) ENPHASE IQ8H-240-72-2-US [240V] [SI1-SB](01) ENCHARGE-10-1P-NA [240V] [SI1-JUN20]BATTERY SIZE: 10.5 KWHCONTRACTORPROJECT NAME & ADDRESS3881 BENATAR WAY STE G,CHICO, CA 95928REVAMP SOLAR ENERGYAPN #: 026090005000AHJ: COUNTY OF BUTTEUTILITY: PG&ERON SUMMERS7055 RAILROAD AVE,PALERMO, CA 95968A1/26/2024AHJ CORRECTIONNOTES1. EXISTING PLUMBING VENTS, SKYLIGHTS,EXHAUSTOUTLETS, VENTILATION INTAKE AIR OPENINGS SHALLNOT BE COVERED BY THE SOLAR PHOTOVOLTAICSYSTEM.2. EQUIPMENT. INVERTERS, MOTOR GENERATORS,PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS,AC PHOTOVOLTAIC MODULES, SOURCE-CIRCUITCOMBINERS, AND CHARGE CONTROLLERS INTENDEDFOR USE IN PHOTOVOLTAIC POWER SYSTEMS WITHBATTERIES SHALL BE IDENTIFIED AND LISTED FOR THEAPPLICATION [CEC 690.4(B)]3. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3RRATED, INCLUDING ALL ROOF MOUNTED TRANSITIONBOXES AND NON ROOF SWITCHES. ROOF SWITCHESTO BE NEMA 3R RATED.4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDEDAND BONDED IN ACCORDANCE WITH CEC ARTICLE 250.5. PROTECTION DEVICES FOR PV SOURCE CIRCUITSAND PV OUTPUT CIRCUITS ALSO CONNECTED TOSOURCES HAVING SIGNIFICANTLY HIGHER CURRENTAVAILABILITY (E.G., PARALLEL STRINGS OFMODULES, UTILITY POWER), SHALL BE PROTECTED ATTHE SOURCE FROM OVERCURRENT [CEC 690.9(A)]6. PV SYSTEM CIRCUITS INSTALLED ON OR INBUILDINGS SHALL INCLUDE A RAPID SHUTDOWNFUNCTION [CEC 690.12]7. THE UTILITY INTERACTIVE INVERTERS SHALLAUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THECONNECTED ELECTRICAL PRODUCTION ANDDISTRIBUTION NETWORK UPON LOSS OF VOLTAGE INTHE SYSTEM AND SHALL REMAIN IN THAT STATE UNTILTHE ELECTRICAL PRODUCTION AND DISTRIBUTIONNETWORK VOLTAGE HAS BEEN RESTORED.[CEC 705.41]8. ALL CONDUCTOR EXPOSED TO WEATHER SHALL BELISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT.[CEC 310.10(D)(1)]9. THE MODULE CONDUCTORS MUST BE TYPE USE-2OR LISTED FOR PHOTOVOLTAIC (PV) WIRE[CEC 690.31(C)]10. ALL CONDUCTORS SHALL BE MARKED ON EACHEND FOR UNIQUE IDENTIFICATION.11. AN INSULATED GROUNDED CONDUCTOR OF 6 AWGOR SMALLER SHALL BE IDENTIFIED AS A CONTINUOUSWHITE FINISH [CEC 200.6]12. THE OUTPUT OF AN INTERCONNECTED ELECTRICALPOWER SOURCE SHALL BE PERMITTED TO BECONNECTED TO THE LOAD SIDE. INTERCONNECTINGPROVISIONS FOR OTHER POWER SOURCES SHALLCOMPLY WITH CEC 705.12(B)(1) THROUGH 705.12(B)(5)23. EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULESSMALLER THAN 6 AWG SHALL BE PROTECTED FROMPHYSICAL DAMAGE BY A RACEWAY OR CABLE ARMOR[CEC 690.46 & 250.120(C)]24. AN EQUIPMENT GROUNDING CONDUCTOR SHALL NOT BESMALLER THAN 14 AWG [CEC 690.45]25. FINE STRANDED CABLES USED FOR BATTERYTERMINALS, DEVICES, AND CONNECTIONS REQUIRE LUGSAND TERMINALS IS IN ACCORDANCE WITH CEC 110.1426. GROUNDING ELECTRODE CONDUCTOR(S) SHALL BEINSTALLED IN ONE CONTINUOUS LENGTH WITHOUT ASPLICE OR JOINT. IF NECESSARY, SPLICES ORCONNECTIONS SHALL BE MADE AS PERMITTED[CEC 250.64(C)]27. ALL SMOKE ALARMS, CARBON MONOXIDE ALARMS ANDAUDIBLE NOTIFICATION DEVICES SHALL BE LISTED ANDLABELED IN ACCORDANCE WITH UL 217 AND UL 2034. THEYWILL BE INSTALLED IN ACCORDANCE WITH NFPA 72 ANDNFPA 720 [IRC 2019 R314 & R315]28. SMOKE ALARMS AND CARBON MONOXIDE ALARMS WILLBE RETROFITTED INTO THE EXISTING DWELLING. THESESMOKE ALARMS ARE REQUIRED TO BE IN ALL BEDROOMS,OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACHFLOOR OF THE HOUSE CARBON MONOXIDE ALARMS AREREQUIRED TO BE RETROFITTED OUTSIDE EACH BEDROOMAND AT LEAST ONE ON EACH FLOOR OF THE HOUSE.THESEALARMS MAY BE SOLELY BATTERY OPERATED IF THEPHOTOVOLTAIC PROJECT DOES NOT INVOLVE THE REMOVALOF INTERIOR WALL AND CEILING FINISHES INSIDE THE HOME,OTHERWISE, THE ALARMS MUST BE HARD WIRED ANDINTERCONNECTED.29. LISTED OR LABELED EQUIPMENT SHALL BE INSTALLEDAND USED IN ACCORDANCE WITH ANY INSTRUCTIONSINCLUDED IN THE LISTING OR LABELING PER NEC.13. EACH SOURCE INTERCONNECTION OF ONE ORMORE POWER SOURCES INSTALLED IN ONE SYSTEMSHALL BE MADE AT A DEDICATED CIRCUIT BREAKER ORFUSIBLE DISCONNECTING MEANS IN ACCORDANCEWITH CEC 705.12.14. THE SUM OF THE AMPERE RATING OF THEOVERCURRENT PROTECTION DEVICES IN CIRCUITSSUPPLYING POWER TO THE BUSBAR OR CONDUCTORSHALL NOT EXCEED 120% OF THE RATING OF BUSBAROR CONDUCTOR IN ACCORDANCE WITH CEC 705.1215. A CONNECTION AT EITHER END, BUT NOT BOTHENDS, OF A CENTER-FED PANEL BOARD IN DWELLINGSSHALL BE PERMITTED WHERE THE SUM OF 125PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUITCURRENT AND THE RATING OF THE OVERCURRENTDEVICE PROTECTING THE BUSBAR DOES NOT EXCEED120 PERCENT OF THE CURRENT RATING OF THEBUSBAR IN ACCORDANCE WITH CEC 705.12.16. EQUIPMENT CONTAINING OVERCURRENTPROTECTION DEVICES IN CIRCUITS SUPPLYING POWERTO A BUS BAR OR CONDUCTOR SHALL BE MARKED TOINDICATE THE PRESENCE OF ALL SOURCES INACCORDANCE WITH CEC 705.12.17. CIRCUIT BREAKER, IF BACKFED, SHALL BE SUITABLEFOR SUCH OPERATION IN ACCORDANCE WITH CEC705.12.18. TO MINIMIZE OVERHEATING OF THE BUSBAR INELECTRICAL ENCLOSURE, THE MAIN CIRCUIT BREAKERAND THE PV POWER SOURCE CIRCUIT BREAKER SHALLBE PHYSICALLY LOCATED AT THE OPPOSITE END OFTHE BUSBAR.19. ALL THE CEC REQUIRED WARNING SIGNS,MARKINGS, AND LABELS SHALL BE POSTED ONEQUIPMENT AND DISCONNECTS PRIOR TO ANYINSPECTIONS.20. WHERE PV SYSTEM DC CIRCUIT'S RUN INSIDE ABUILDING, THEY SHALL BE CONTAINED IN METALRACEWAYS TYPE MC METAL CLAD CABLE OR METALENCLOSURES FROM POINT OF PENETRATION OF THESURFACE OF THE BUILDING TO THE FIRST READILYACCESSIBLE DISCONNECTING MEANS [CEC 690.31(G)].21. FLEXIBLE, FINE-STRANDED CABLES SHALL BETERMINATED ONLY WITH TERMINALS, LUGS, DEVICESOR CONNECTORS THAT ARE LISTED IN ACCORDANCEWITH CEC 110.14.22. CONNECTORS SHALL BE OF LATCHING OR LOCKINGTYPE. CONNECTORS THAT ARE READILYACCESSIBLE AND OPERATING AT OVER 30V DC OR 15VAC SHALL REQUIRE TOOL TO OPEN AND MARKED "DONOT DISCONNECT UNDER LOAD" OR "NOTFOR CURRENT INTERRUPTING"[CEC 690.33(C) & (E)(2)].GENERAL NOTES DRIVEWAYPV-061/26/2024SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (530) 720-5377LIC. NO. - 1068160REVDATEDESCRIPTIONREVISIONSDC SIZE: 8.025 KW DC-(STC)CEC AC SIZE: 7.304 KW AC(15) JA SOLAR JAM72D30 535/MB(15) ENPHASE IQ8H-240-72-2-US [240V] [SI1-SB](01) ENCHARGE-10-1P-NA [240V] [SI1-JUN20]BATTERY SIZE: 10.5 KWHCONTRACTORPROJECT NAME & ADDRESS3881 BENATAR WAY STE G,CHICO, CA 95928REVAMP SOLAR ENERGYAPN #: 026090005000AHJ: COUNTY OF BUTTEUTILITY: PG&ERON SUMMERS7055 RAILROAD AVE,PALERMO, CA 95968A1/26/2024AHJ CORRECTIONWARNING LABELSLABEL LOCATION: RSD INITIATION DEVICE, AC DISCONNECTPER CODE: CEC 690.56(C)(2)ELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONWARNINGLABEL LOCATION: COMBINER PANEL, ACDISCONNECT, POINT OF INTERCONNECTIONPER CODE: CEC 706.15(C)(4), CEC 690.13(B)LABEL LOCATION: MAIN SERVICE DISCONNECT, UTILITY METERPER CODE: CEC 690.13(B)POWER SOURCE OUTPUTCONNECTION. DO NOT RELOCATETHIS OVERCURRENT DEVICE.WARNINGLABEL LOCATION: POINT OF INTERCONNECTIONPER CODE: CEC 705.12(B)(3)(2)LABEL LOCATION: AC DISCONNECTPER CODE: CEC 705.12(B)(3)(3)TURN OFF PHOTOVOLTAIC ACDISCONNECT PRIOR TOWORKING INSIDE PANELWARNINGLABEL LOCATION: COMBINER PANEL(S), MAIN SERVICE DISCONNECTPER CODE: CEC 110.27(C), OSHA 1910.145(f)(7)ELECTRICAL SHOCK HAZARDTERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONWARNINGDC VOLTAGE IS ALWAYS PRESENT WHENSOLAR MODULES ARE EXPOSED TO SUNLIGHTLABEL LOCATION: DC DISCONNECTPER CODE: CEC 690.13(B)LABEL LOCATION: AC DISCONNECTPER CODE: CEC 690.13(B)LABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: CEC 690.56(C)!!!!PHOTOVOLTAIC POWER SOURCELABEL LOCATION: DC CONDUIT/RACEWAYSPER CODE: CEC 690.31(D)(2)SOLAR PV DC CIRCUITLABEL LOCATION: DC CONDUIT/RACEWAYSPER CODE: CEC 690.31(D)(2)LABEL LOCATION: AC DISCONNECT/POINT OF INTERCONNECTIONPER CODE: CEC 690.54PHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OUTPUT CURRENT:23.70 ANOMINAL OPERATING AC VOLTAGE:240 VTHIS EQUIPMENT FED BY MULTIPLESOURCES:TOTAL RATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEEDAMPACITY OF BUSBARWARNING!LABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: CEC 705.12(D), CEC 690.59CAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED!SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYDO NOT DISCONNECTUNDER LOADLABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: CEC 690.15(B) & CEC 690.33(D)(2)WARNINGMULTIPLE POWER SOURCESOURCES: UTILITY GRID, PV AND ESS SYSTEMLABEL LOCATION: MAIN SERVICE DISCONNECT, PRODUCTION/NET METERPER CODE: CEC 690.59, 705.12(C)!LABEL LOCATION: DC DISCONNECT/INVERTER/PV DIST.EQUIPMENTPER CODE: CEC 690.53MAXIMUM DC VOLTAGEOF PV SYSTEMPV SYSTEMDISCONNECTRAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMMAIN PHOTOVOLTAICSYSTEM DISCONNECTBATTERYMULTIPLE SOURCES OF POWER.POWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWN:CAUTIONADDRESS: 7055 RAILROAD AVE, PALERMO, CA 95968RAPID SHUTDOWN SWITCH& GATEWAYACCOMBINER PANELUTILITY METER ANDMAIN SERVICE PANELENERGYSTORAGESYSTEMDISCONNECTLABEL LOCATION: ESS DISCONNECTPER CODE: NEC 706.15(C)SINGLE 120-VOLT SUPPLYDO NOT CONNECTMULTIWIRE BRANCH CIRCUITSWARNINGLABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 705.82!THE MAIN SERVICE BREAKER HASBEEN DOWNSIZED TO 100 AMPS. NOUP-SIZING IS PERMITTED.LABEL LOCATION: MAIN SERVICE PANELFRONT OF HOUSE BACKUPLOAD PANEL ARRAY 1FRONT OF HOUSE 15'-2"NREFERENCE ONLYPV-071/26/2024SHEET TITLEDRAWN DATEDRAWN BYPCADSHEET NUMBERSYSTEM DETAILSPHONE - (530) 720-5377LIC. NO. - 1068160REVDATEDESCRIPTIONREVISIONSDC SIZE: 8.025 KW DC-(STC)CEC AC SIZE: 7.304 KW AC(15) JA SOLAR JAM72D30 535/MB(15) ENPHASE IQ8H-240-72-2-US [240V] [SI1-SB](01) ENCHARGE-10-1P-NA [240V] [SI1-JUN20]BATTERY SIZE: 10.5 KWHCONTRACTORPROJECT NAME & ADDRESS3881 BENATAR WAY STE G,CHICO, CA 95928REVAMP SOLAR ENERGYAPN #: 026090005000AHJ: COUNTY OF BUTTEUTILITY: PG&ERON SUMMERS7055 RAILROAD AVE,PALERMO, CA 95968A1/26/2024AHJ CORRECTIONINSTALLATIONRESOURCE12345678910ABCDEF**DIMENSIONS ARE 2D (FLAT) Summers (#1259371)ground based 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Page 1 of 6Last updated by Rishabh Yadav on 11/22/23 01:28 AM Project Details Name Summers Date 11/22/2023 Location 7055 Railroad Avenue, Palermo, CA 95968 ASCE code 7.10 Total modules 16 Wind speed 100 mph Module JA Solar : JAM72D30-535/MB (35mm)Snow load 0 psf Dimensions Dimensions: 89.96" x 44.65" x 1.38" (2285.0mm x 1134.0mm x 35.0mm)Wind exposure C Total watts 8,560 kW Piers 6 Concrete 1.40 yd³ Inter sub-arrayspacing 227.0"Calculated using solar azimuth of -42.88° and solar elevation of 13.83° at 9AM (America/Los_Angeles) on the winter solistice. Substructure & Foundation Tilt 25°South facing grade 0° Pipe/tubing diameter 3"Soil class 2 Foundation type Concrete Hole diameter 16" Summers (#1259371)ground based 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Page 2 of 6Last updated by Rishabh Yadav on 11/22/23 01:28 AM Sub array #1 Rows 4 Columns 4 # Arrays 1 Area 30' 1" (EW) × 15' 2" (NS)Rail type XR1000 Diagonal bracing no E/W spacing 12' 7"Rail cantilever 3' 6"Pipe cantilever 2' 6" Piers/array 6 Total south piers 3 (5' 4")Total north piers 3 (9' 7") Total cross pipes 2 (30' 1")Total pipe length 104' 11" Shear 1,466 lbs Moment 3,664 ft-lbs Uplift -1,813 lbs Summers (#1259371)ground based 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Page 3 of 6Last updated by Rishabh Yadav on 11/22/23 01:28 AM 30'1"17'15'2' 6"CANTILEVER 12' 7"E-W PIER SPACING 9'N-S PIER SPACINGCROSS PIPE LENGTH Summers (#1259371)ground based 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Page 4 of 6Last updated by Rishabh Yadav on 11/22/23 01:28 AM Pipe Fitting Detail XR1000 Rail Front View 3” TOP CAP 3” PIPE/TUBING 3” RAIL CONNECTOR XR1000 RAIL PV MODULE Side View 3” PIPE/TUBING 3” TOP CAP 3” RAIL CONNECTOR XR1000 RAIL PV MODULE UNIVERSAL FASTENING OBJEC Clamp Detail Mid Clamp, Plan UNIVERSAL FASTENING OBJECT PV MODULE FRAME Mid Clamp, Front RAIL PV MODULE FRAME UNIVERSAL FASTENING OBJECT End Clamp, Plan STOPPER SLEEVE UNIVERSALFASTENING OBJECT PV MODULEFRAME RAIL 1” End Clamp, Front PV MODULE FRAME RAIL UNIVERSAL FASTENINGOBJECT STOPPER SLEEVE1” 2 0 4 " R A IL 3 ' 6 "R A IL C A N T IL E V E R 1' 4" HOLE DIAMETER4' 6"DEPTHHOLE 3'2' 4"6' 7"9' 7"8' 4"CLEARANCENORTH 1' 2"CLEARANCESOUTH N-S PIER SPACING 9' 15' 5" 3' 2" 25° Summers (#1259371)ground based 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Page 5 of 6Last updated by Rishabh Yadav on 11/22/23 01:28 AM Grounding Diagram UFO Clamp Grounding Lug Min 10 AWG Copper Wire Fault Current Ground Path Bonding Points Fault Current Ground Path *Grounding Lugs and wire are not required in systems using certain Enphase microinverters or certain Sunpower modules. Equipment grounding is achieved with the Engage cable for Enphase or the AC module cable system for Sunpower via their integrated EGC. * * Section View Plan View Optional Cross Brace Only one Grounding Lug required per continuous subarray.* Cross Pipe RailCross Pipe UFO or CAMO Summers (#1259371)ground based 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Page 6 of 6Last updated by Rishabh Yadav on 11/22/23 01:28 AM Bill of Materials Part Spares Total Qty Rails XR-1000-204A XR1000, Rail 204" Clear 0 8 Clamps & Grounding UFO-CL-01-A1 Universal Module Clamp, Clear 0 40 UFO-STP-35MM-M1 Stopper Sleeve, 35MM, Mill 0 16 XR-LUG-03-A1 Grounding Lug, Low Profile 0 1 Substructure 70-0300-SGA SGA Top Cap at 3"0 6 GM-BRC3-01-M1 Ground Mount Bonded Rail Connector - 3"0 16 GROUND MOUNT INSTALLATION MANUAL - 3© 2022 IRONRIDGE, INC. VERSION 3.4 CHeCKLIST IRONRIDGe COMPONeNTSPRe-INSTALLATION ☐Verify module compatibility. See Page 14 for info. ☐Purchase 2” or 3” Pipe or Mechanical Tubing Pipe: 2” or 3” (NPS) ASTM A53 Grade B SCH 40 Pipe, galvanized to a min of ASTM A653 G90 or ASTM A123 G35. Mechanical Tubing: 2.375” x 12 ga (O.D) or 3.500” x 8 ga (O.D.) Mechanical Tubing with one of the following Galvinizations (ASTM A1057). • Allied Gatorshield • Allied Flo-Coat Coating • Wheatland ThunderCoat TOOLS ReQUIReD ☐Post Hole Digger or Powered Auger ☐Socket Drive (7/16”, 9/16”, 15/16” and 1/2” Sockets) ☐Torque Wrenches (0-240 in-lbs and 10-40 ft-lbs) ☐Transit, String Line, or Laser Level ☐3/16” Allen Head TORQUe VALUeS Top Cap Set Screws (3/16” Allen Head) ☐2” or 3” NPS Schedule 40 Grade B Pipe: 20 ft-lbs ☐2.375” x 12 ga OD Mechanical Tubing: 11 ft-lbs ☐3.500” x 8 ga OD Mechanical Tubing: 16 ft-lbs ☐For Ground Screw to Pipe Connection Hardware see Page 5. ☐Top Cap U-Bolt Nuts (9/16” Socket): 15 ft-lbs ☐Rail Connector Bracket Nuts (9/16” Socket): 21 ft-lbs ☐Rail Connector U-Bolt Nuts (9/16” Socket): 60 in-lbs ☐Rail Grounding Lug Nut (7/16” Socket): 80 in-lbs ☐Rail Grounding Lug Terminal Screws (7/16” Socket): 20 in-lbs ☐Module Grounding Lug Nut (3/8” Socket): 60 in-lbs ☐Module Grounding Lug Terminal Screws (1/2” Socket): 20 in-lbs ☐Universal Fastening Objects (7/16” Socket): 80 in-lbs ☐Diagonal Brace Set Screws (1/2” Socket): 15 ft-lbs ☐Diagonal Brace Bolts (1/2” Socket): 40 ft-lbs ☐Microinverter Kit Nuts (7/16” Socket): 80 in-lbs ☐Frameless Module Kit Nuts (7/16” Socket): 80 in-lbs ➢If using previous version of: Integrated Grounding Mid Clamps, Grounding Lug and end Clamps please refer to Alternate Components Addendum (Version 1.90). ➢If installing on a low slope roof please refer to Ground Mount for Flat Roof Applications Addendum (Version 3.30). ➢Unless otherwise noted, all components have been evaluated for multiple use. They can be uninstalled and reinstalled in the same or new location. XR100 & XR1000 Rail Rail Connector Top Cap UFO (30-46mm) Diagonal Brace Stopper Sleeve Rail Grounding Lug Microinverter Kit Frameless Module Kit Frameless End/Mid Clamp CAMO End Cap Wire Clip Module Grounding Lug Hex Head Set Screw IronRidge February 1, 2023 Mr. Corey Geiger Page 33 of 76 Ground Mounting System – Structural Analysis – 4 Module (XR1000) Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers - 33 - Notes: see page 38 3" Unbraced Pipe Frame Wind Speed & Exposure Category 0 5 10 15 20 25 30 35 40 45 0 230 235 203 197 187 179 172 145 123 105 10 200 203 187 184 181 179 172 145 123 105 20 170 172 162 161 161 162 163 145 123 105 30 159 161 153 152 153 155 157 145 123 105 40 145 145 140 140 142 145 148 145 123 105 50 131 131 131 130 133 137 141 145 123 105 60 121 121 121 123 126 130 134 141 123 105 0 221 226 194 189 179 171 154 130 111 94 10 196 199 181 179 175 171 154 130 111 94 20 167 170 159 157 157 157 154 130 111 94 30 157 159 150 149 150 151 152 130 111 94 40 143 145 138 138 139 142 144 130 111 94 50 131 131 129 128 131 134 138 130 111 94 60 121 121 121 121 124 128 132 130 111 94 0 212 217 186 181 171 163 139 117 100 85 10 191 194 176 174 170 163 139 117 100 85 20 165 167 155 154 153 153 139 117 100 85 30 155 156 147 146 146 147 139 117 100 85 40 142 143 136 135 137 139 139 117 100 85 50 131 131 127 127 129 131 134 117 100 85 60 121 121 120 119 122 125 129 117 100 85 0 204 178 162 148 137 134 126 107 91 77 10 186 178 162 148 137 134 126 107 91 77 20 162 164 152 148 137 134 126 107 91 77 30 152 154 144 143 137 134 126 107 91 77 40 140 141 134 133 134 134 126 107 91 77 50 130 131 125 125 126 129 126 107 91 77 60 121 121 118 118 120 123 126 107 91 77 0 196 202 171 166 157 150 115 97 83 70 10 182 185 167 164 157 150 115 97 83 70 20 159 161 149 147 145 145 115 97 83 70 30 150 152 141 140 139 140 115 97 83 70 40 138 139 131 130 131 132 115 97 83 70 50 128 130 123 123 124 126 115 97 83 70 0 183 188 159 154 145 132 97 82 69 59 10 174 177 158 154 145 132 97 82 69 59 20 153 155 142 140 138 132 97 82 69 59 30 145 147 136 134 133 132 97 82 69 59 40 134 136 127 126 126 126 97 82 69 59 50 125 127 119 119 120 121 97 82 69 59 0 171 175 148 143 135 112 82 70 59 50 10 166 169 148 143 135 112 82 70 59 50 20 147 150 136 134 131 112 82 70 59 50 30 140 142 130 129 127 112 82 70 59 50 40 130 132 122 121 121 112 82 70 59 50 50 122 124 116 115 115 112 82 70 59 50 0 160 165 138 134 126 97 71 60 51 43 10 158 162 138 134 126 9771 60 51 43 20 142 145 130 128 125 97 71 60 51 43 30 135 138 125 123 121 9771 60 51 43 40 127 128 118 117 116 9771 60 51 43 50 119 121 112 111 111 9771 60 51 43 0 150 155 130 126 118 84 62 52 44 38 10 150 154 130 126 118 84 62 52 44 38 20 137 140 125 123 118 84 62 52 44 38 30 131 133 120 118 116 84 62 52 44 38 40 123 125 114 113 111 84 62 52 44 38 0 142 146 122 118 10774 54 46 39 33 10 142 146 122 118 10774 54 46 39 33 20 132 135 120 117 10774 54 46 39 33 30 127 129 116 114 10774 54 46 39 33 40 119 121 110 108 10774 54 46 39 33 100 mph Exposure C Table 2N ‐ MAXIMUM PIER SPACING (in) (APPLICABLE TO PANELS UP TO 92.5in) Slope (deg) 90 mph Exposure C 95 mph Exposure C Snow psf 105 mph Exposure C 110 mph Exposure C 120 mph Exposure C 130 mph Exposure C 140 mph Exposure C 150 mph Exposure C 160 mph Exposure C IronRidge February 1, 2023 Mr. Corey Geiger Page 47 of 76 Ground Mounting System – Structural Analysis – 4 Module (XR1000) Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers - 47 - Notes: see page 76 3" Pipe Frame Unbraced Wind Speed & Exposure Category 0 5 10 15 20 25 30 35 40 45 12 36 36 36 42 48 54 60 60 60 60 16 36 36 36 36 42 48 54 54 54 54 20 36 36 36 36 36 42 48 48 48 48 24 36 36 36 36 36 42 42 42 42 42 12 36 36 36 42 48 54 60 60 60 60 16 36 36 36 36 42 48 54 54 54 54 20 36 36 36 36 42 42 48 48 48 48 24 36 36 36 36 36 42 42 42 42 42 12 36 36 36 42 48 54 60 60 60 60 16 36 36 36 36 42 48 54 54 54 54 20 36 36 36 36 42 48 48 48 48 48 24 36 36 36 36 36 42 42 42 42 42 12 36 36 36 42 48 54 60 60 60 60 16 36 36 36 36 42 48 54 54 54 54 20 36 36 36 36 36 42 48 48 48 48 24 36 36 36 36 36 42 42 42 42 42 12 36 36 36 42 48 60 60 60 60 60 16 36 36 36 36 48 54 54 54 54 54 20 36 36 36 36 42 48 48 48 48 48 24 36 36 36 36 36 42 42 42 42 42 12 36 42 42 48 54 60 60 60 60 60 16 36 36 36 42 48 54 54 54 54 54 20 36 36 36 36 42 48 48 48 48 48 24 36 36 36 36 42 42 42 42 42 42 12 36 42 42 48 54 60 60 60 60 60 16 36 36 36 42 48 54 54 54 54 54 20 36 36 36 36 42 48 48 48 48 48 24 36 36 36 36 42 42 42 42 42 42 12 42 48 48 54 54 60 60 60 60 60 16 36 36 36 42 48 54 54 54 54 54 20 36 36 36 42 48 48 48 48 48 48 24 36 36 36 36 42 42 42 42 42 * 12 42 48 48 54 60 60 60 60 60 60 16 36 42 42 42 54 54 54 54 54 54 20 36 36 36 42 48 48 48 48 48 * 24 36 36 36 36 42 42 42 42 * * 12 48 54 54 60 60 60 60 60 60 60 16 36 42 42 48 54 54 54 54 54 54 20 36 36 36 42 48 48 48 48 * * 24 36 36 36 36 42 42 42 * * * 150 mph Exposure C 160 mph Exposure C 105 mph Exposure C 110 mph Exposure C 120 mph Exposure C 130 mph Exposure C 140 mph Exposure C Pier Dia (in) Slope (deg) 90 mph Exposure C 95 mph Exposure C 100 mph Exposure C Soil Class 2 Table 4B ‐ MINIMUM FOUNDATION DEPTHS (in) Summers (#1259371)ground based 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Page 1 of 2Last updated by Rishabh Yadav on 11/22/23 01:28 AM Project Details ID 1259371 Name Summers Location 7055 Railroad Avenue, Palermo, CA 95968 Module JA Solar : JAM72D30-535/MB (35mm) Total modules 16 Tilt 25 degrees Total watts 8.56 kW Piers 6 Foundation type Concrete Foundation info 1.40 cu yd Pipe diameter 3"Total pipe length 104' 11" Sub array Details Rows Columns #Arrays Size Railtype Rails percolumn Diagonalbracing Piers/array Edgeclearance E/W pierspan Totalsouth piers Totalnorth piers Totalcross pipes Pipecantilever Total pipelength 4 4 1 30' 1" (EW) x15' 2" (NS)XR1000 2 false 6 1' 2" (S); 8' 4"(N)12' 7"3 (5' 4")3 (9' 7")2 (30' 1")2' 6"104' 11" Summers (#1259371)ground based 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Page 2 of 2Last updated by Rishabh Yadav on 11/22/23 01:28 AM Bill of Materials Part Spares Total Qty MSRP Total Rails XR-1000-204A XR1000, Rail 204" Clear 0 8 $167.18 $1,337.44 Clamps & Grounding UFO-CL-01-A1 Universal Module Clamp, Clear 0 40 $4.86 $194.40 UFO-STP-35MM-M1 Stopper Sleeve, 35MM, Mill 0 16 $0.87 $13.92 XR-LUG-03-A1 Grounding Lug, Low Profile 0 1 $9.65 $9.65 Substructure 70-0300-SGA SGA Top Cap at 3"0 6 $89.10 $534.60 GM-BRC3-01-M1 Ground Mount Bonded Rail Connector - 3"0 16 $24.65 $394.40 Total MSRP $2,484.41 Discount (0.0%)($0.00) Total Price $2,484.41 $/Watt $0.29 Weight 188.6 lbs