Loading...
HomeMy WebLinkAbout047-440-075 B24-0971 REVISED SITE PLAN120120 120120 120120 120120 4020FX4020FX4020FX3050SC4020FX4020FX120120120120120120120120 FX SH SC LS AW HO LV RSDCDH FHFA TC TS TA TH BROKENARCH ROUND TOP PT FX FIXED GLASS SH SINGLE HUNG DH DOUBLE HUNG SC SINGLE CASEMENT DC DOUBLE CASEMENT TC TRIPLE CASEMENT LS LEFT SLIDING**RS RIGHT SLIDING**TS TRIPLE SLIDING** AW SINGLE AWNING FA DOUBLE AWNING TA TRIPLE AWNING HO HOPPER FH DOUBLE HOPPER TH TRIPLE HOPPER LV LOUVERED PT PASS THRU - NO GLASS **NOTE: WINDOWS ARE AS VIEWED FROM OUTSIDE LOOKING INWARD. WINDOW LABELS 4'-0"12'-0"3'-4"12'-0"3'-4"12'-0"3'-4"12'-0"4'-0" 66'-0"40'-0"6'-0"7'-0"7'-0"7'-0"7'-0"6'-0"40'-0"4'-0"12'-0"3'-4"12'-0"3'-4"12'-0"3'-4"12'-0"4'-0" 66'-0" FLOOR PLAN NOTES:FLOOR PLAN NOTES: 1.)NOTE: ALL NOTES ON THIS PLAN REFER TO THE NOTESNOTES, , SEE SHEET INDEX FOR LOCATION. 2.)SEE DETAIL 1/SD1 FOR TYPICAL SHEAR WALL SCHEDULETYPICAL SHEAR WALL SCHEDULE.. 3.)AUTOMATIC RESIDENTIAL FIRE SPRINKLERS ARE NOT REQUIRED. 4.)A PHOTOVOLTAIC (SOLAR) SYSTEM WILL NOT BE INSTALLED. 5.)SUBMIT FINAL CONSTRUCTION WASTE MANAGEMENT REPORT TO THE BUILDING DEPARTMENT PRIOR TO FINAL INSPECTION. CGBSC 4.408 6.)SUBMIT RESIDENTIAL MANDATORY MEASURES CHECKLIST TO THE BUILDING DEPARTMENT. CGBSC 7.)THE WATER DISTRIBUTION SYSTEM WILL BE USING PEX PIPING. SEE NOTESNOTES, PLUMBING. 8.)PLATE HEIGHT TO BE 14' UNLESS NOTED OTHERWISE. 9.)TYPICAL WALL FRAMING, UNLESS NOTED OTHERWISE: EXTERIOR WALLS: 2"x6" DF STUDS @ 16" c/c FLOOR PLAN SCALE: 1/4" = 1'-0" NOTE: HOLD TOP OF WINDOWS AT 8'-0".UNLESS NOTED OTHERWISE SHEET INDEXSHEET INDEX 1 FLOOR PLAN 2 FOUNDATION PLAN SECTION A-2 3 ROOF PLAN ROOF VENTILATION CALCS TRUSS LAYOUT SHEET 4 EXTERIOR ELEVATIONS 5 ELECTRICAL PLAN ELECTRICAL NOTES ELECTRICAL LEGEND 6 PLOT PLAN ASSESSORS MAP LOCATION MAP SN STRUCTURAL NOTES SD1 STRUCTURAL DETAILS SD2 STRUCTURAL DETAILS THIS PLAN TO COMPLY WITH THE FOLLOWING:THIS PLAN TO COMPLY WITH THE FOLLOWING: 2022 CALIFORNIA BUILDING CODE (CBC) - STRUCTURAL ONLYSTRUCTURAL ONLY 2022 CALIFORNIA RESIDENTIAL CODE (CRC), 2022 CALIFORNIA MECHANICAL CODE (CMC), 2022 CALIFORNIA PLUMBING CODE (CPC), 2022 CALIFORNIA ELECTRICAL CODE (CEC), 2022 CALIFORNIA FIRE CODE (CFC), 2022 CALIFORNIA ENERGY CODE (CEnC) 2022 CALIFORNIA GREEN BUILDINGS STANDARDS CODE (CGBSC) (COMMONLY CALLED "CALGREEN") LOCAL CODES OCCUPANCY GROUP:OCCUPANCY GROUP: OCCUPANCY IS U CONSTRUCTION TYPE:CONSTRUCTION TYPE: CONSTRUCTION TYPE IS VB FIRE SPRINKLERS:FIRE SPRINKLERS: NOT REQUIRED. SOLAR ENERGY:SOLAR ENERGY: A PHOTOVOLTAIC SYSTEM IS NOT REQUIREDA PHOTOVOLTAIC SYSTEM IS NOT REQUIRED. CARPORT/COVERED PATIO A 2 A 2 A 2 A 2 CONCRETE SLAB FLOORCONCRETE SLAB FLOOR UNCOVERED WALLS & CEILINGUNCOVERED WALLS & CEILING SEE NOTESNOTES, LANDINGS. CONCRETECONCRETE WALKWAYWALKWAY CONCRETECONCRETE WALKWAYWALKWAY FLOOR PLAN STRUCTURAL NOTES:FLOOR PLAN STRUCTURAL NOTES: 1.)       SEE TYPICAL NOTE SHEET SN AND TYPICAL DETAIL             SHEETS SD1-SD2 FOR ADDITIONAL INFORMATION. 2.)       TYPICAL MINIMUM BEARING WALL FRAMING U.N.O.:                 EXTERIOR WALL: 2X6 DF#2 AT 16" O.C.   **NOTE:     SHEATH ALL EXTERIOR WALLS PER SWS                         TYPE "6" MINIMUM, UNLESS NOTED OTHERWISE.   3.)       SEE DETAIL 5/SD1 FOR TYPICAL STUD WALL             ELEVATION AND TYPICAL WALL OPENING SCHEDULE. 4.)       ANY DISCREPANCIES BETWEEN FRAMING SHOWN AND             FIELD CONDITIONS SHALL BE IMMEDIATELY BROUGHT             TO THE ENGINEER OF RECORD. 5.)       ALL FRAMING EXPOSED TO WEATHER, WITHOUT                ADEQUATE PROTECTION, SHALL BE PRESSURE             TREATED WITH TREATMENT PROCESS AND             APPLICATION APPROPRIATE FOR EXPOSURE             ACCORDING TO MFR'S WRITTEN GUIDELINES. 6.)       ALL STRUCTURAL MEMBERS SHALL BE FASTENED IN      COMPLIANCE WITH 2022 CBC FASTENING SCHEDULE,     TABLE 2304.10.2, UNLESS NOTED OTHERWISE. 7.)       DRAIN WATER ONTO IMPERMEABLE SURFACES SLOPED           AWAY FROM BUILDING OR INTO CLOSED CONDUIT                        DISCHARGING 10'-0" MIN. FROM BUILDING. SEE                   GEOTECH REPORT, WHERE APPLICABLE, FOR                                ADDITIONAL INFORMATION. L=4.0' 4*4*HDU4SSTB201SD21SD2 TYP. L=4.0' 4*4*HDU4SSTB20HDU4SSTB20L=4.0' 4*4*HDU4SSTB20HDU4SSTB20L=4.0' 4*4*HDU4SSTB20L=3.33' 4*4*HDU4SSTB20HDU4SSTB205 SD2 5 SD2 L=3.33' 4*4*HDU4SSTB205SD25SD2 HDU4SSTB20L=40.0' 5 SD1 5 SD1 TYP.TOP AT 12'TOP AT 12'TOP AT 12'TOP AT 12'TOP AT 12'66 H DU 8S S T B28L=4.0'22 H D U8 S S T B 2 8 L=4.0'22 HDU8SSTB28HDU8SSTB28 © COPYRIGHT 2023 SHEET 2640 SHOWN 5/6/2024 SCALE: DATE:DARRON & KRISTIANE RANSBARGERDARRON & KRISTIANE RANSBARGER5046 SAN JUANICO DRIVE, CHICO, CALIFORNIA 95973ASSESSORS PARCEL NUMBER 047 - 440 - 075A CARPORT / COVERED PATIO for:G.S.M. CONSTRUCTIONSUMMIT STRUCTURAL DESIGN - STRUCTURAL ENGINEER383 RIO LINDO AVENUE #200, CHICO, CA 95926(530) 592-4407 WORK EMAIL ADDRESS: Ryland@SummitChico.com ARCH D (24" x 36") 1 STORY THESE PLANS HAVE BEENREVIEWED ONLY FORCOMPLIANCE WITH ATTACHEDSTRUCTURAL CALCULATIONS. THE ENGINEER'S STAMP ON THIS PLAN IS VALID ONLY WITH A LETTER SIGNED BY THISENGINEER FOR EACHUNIQUE BUILD. 1 C:/Users/Lynn/OneDrive/Documents/Chief X15 Plans/Gareth Munoz - Ransbarger Patio/RansbargerPatio.layoutOWNER: DARRON & KRISTIANE RANSBARGER(530) 966-2336 CELLEMAIL ADDRESS: Darron.Ransbarger@GMail.com MAX RAMIREZ - GOLDEN SUN DESIGN - ENERGY CALCS22189 SAMSON AVENUE, CORNING, CALIFORNIA 96021PHONE: (530) 321-7242 CELLEMAIL ADDRESS: AlphaMax47@GMail.com WHILE EVERY ATTEMPT HASBEEN MADE IN THEPREPARATION OF THIS PLANTO AVOID MISTAKES, THE MAKER CANNOT GUARANTEE AGAINST HUMAN ERROR. BUILDING CONTRACTOR / HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. LYNN SMITH - DRAFTING199 SYCAMORE VALLEY ROAD, CHICO, CA 95973(530) 891-0585 WORK EMAIL ADDRESS: LynnSmith32@ATT.net (E) LIVABLE(E) LIVABLE:: 4027 SqFt (E) TOTAL4027 SqFt (E) TOTAL (E) GARAGE(E) GARAGE:: 1293 SqFt (E) TOTAL1293 SqFt (E) TOTAL CARPORTCARPORT & COVERED& COVERED PATIOSPATIOS:: 2161 SqFt EXIST 2640 SqFt NEW 4801 SqFt TOTAL4801 SqFt TOTALFLOOR PLAN2023GSM CONSTRUCTIONGARETH MUNOZ (530) 591-0111EMAIL ADDRESS: GarethMunoz@GMail.com 5/6/2024 4'-0"12'-0"3'-4"12'-0"3'-4"12'-0"3'-4"12'-0"4'-0" 66'-0"40'-0"4'-0"12'-0"3'-4"12'-0"3'-4"12'-0"3'-4"12'-0"4'-0" 66'-0"40'-0"DEEP SCORE FOUNDATION PLAN SCALE: 1/4" = 1'-0" NOTE: ALL ANCHOR BOLTS & HOLD-DOWN BOLTS SHALL BE IN PLACE FOR FOUNDATION INSPECTION. NOTE: PLUMBING DEAD LEGS SHALL HAVE A METHOD OF FLUSHING. CRC R309.6 4" CONCRETE SLAB4" CONCRETE SLAB W/ #3 REBAR AT 24"c/c EACH WAY OVER 4" ROCK BASE. DO NOT SLOP FLOOR. GRADING AT FOUNDATION:GRADING AT FOUNDATION: THE GROUND IMMEDIATELY ADJACENT TO THE FOUNDATION SHALL SLOPE AWAY FROM THE BUILDING AT A SLOPE OF NOT LESS THAN 6 INCHES WITHIN THE FIRST 10 FEET (5% SLOPE). DEEP SCOREDEEP SCOREDEEP SCOREDEEP SCOREDEEP SCOREDEEP SCOREDEEP SCOREDEEP SCOREDEEP SCOREFOUNDATION PLAN STRUCTURAL NOTES:FOUNDATION PLAN STRUCTURAL NOTES: 1.)       SEE TYPICAL NOTE SHEET SN AND TYPICAL DETAIL             SHEETS SD1-SD2 FOR ADDITIONAL INFORMATION. 2.)       PROVIDE ANCHOR BOLT SIZE AND SPACING PER             SHEAR WALL SCHEDULE AND TYPICAL DETAILS. 3.)       MINIMUM SLAB SECTION:               A-       4" CONCRETE SLAB WITH #3 AT 24" O.C. E.W.                         SECURELY LOCATED AT MID-DEPTH OF SLAB.             B-       WATERPROOF MEMBRANE IN COMPLIANCE WITH ASTM E 1643 (DELETE AT EXTERIOR                           SLABS)-SEE SOILS REPORT IF APPLICABLE.             C-       4" FREE DRAINING MATERIAL-SEE SOILS REPORT                         IF APPLICABLE.             D-       PROPERLY PREPARED SUBGRADE-SEE SOILS                         REPORT IF APPLICABLE.             E-        CONTRACTOR TO PROVIDE CONTROL JOINTS AT                         10'-0" O.C. EA. WAY MAX.               NOTE: CURING OF SLABS SHALL FOLLOW GUIDELINES                         PROVIDED BY THE AMERICAN CONCRETE INSTITUTE                         AND THE CALIFORNIA BUILDING CODE TO MINIMIZE                         SHRINKAGE CRACKING.   4.)       TYPICAL MINIMUM BEARING WALL FRAMING U.N.O.:                 EXTERIOR WALL: 2X6 DF#2 AT 16" O.C.   **NOTE:     SHEATH ALL EXTERIOR WALLS PER SWS                         TYPE "6" MINIMUM, UNLESS NOTED OTHERWISE. 5.)       SEE DETAIL 5/SD1 FOR TYPICAL STUD WALL             ELEVATION AND TYPICAL WALL OPENING SCHEDULE. 6.)       PLUMBING, SPRINKLER, AND MECHANICAL                SUBCONTRACTORS SHALL COORDINATE ALL WALL             PENETRATIONS WITH FRAMING SUBCONTRACTOR. 7.)       ANY DISCREPANCIES BETWEEN FRAMING SHOWN AND             FIELD CONDITIONS SHALL BE IMMEDIATELY BROUGHT             TO THE ENGINEER OF RECORD. 8.)       ALL FRAMING EXPOSED TO WEATHER, WITHOUT   ADEQUATE PROTECTION, SHALL BE PRESSURE             TREATED WITH TREATMENT PROCESS AND             APPLICATION APPROPRIATE FOR EXPOSURE             ACCORDING TO MFR'S WRITTEN GUIDELINES. 9.)       ALL STRUCTURAL MEMBERS SHALL BE FASTENED IN    COMPLIANCE WITH 2022 CBC FASTENING SCHEDULE, TABLE 2304.10.2, UNLESS NOTED OTHERWISE. 10.)    DRAIN WATER ONTO IMPERMEABLE SURFACES SLOPED AWAY FROM BUILDING OR INTO CLOSED CONDUIT DISCHARGING 10'-0" MIN. FROM BUILDING. SEE GEOTECH REPORT, WHERE APPLICABLE, FOR ADDITIONAL INFORMATION. 11.)    VERIFY ALL ELEVATIONS, STEPS, DIMENSIONS, WALL       SIZES AND LOCATIONS, AND FLOOR ELEVATIONS WITH ARCHITECT/DESIGNER. 12.)    SEE DETAIL 6/SD2 FOR TYPICAL SPREAD FOOTING SCHEDULE. TYP 3SD23SD2 TYP 2 SD2 2 SD2 F2.5F2.530x30 F2.5F2.5 30x30F2.5F2.530x30F2.5F2.5 30x30F2.5F2.530x30F2.5F2.5 30x30F2.5F2.530x30F2.5F2.5 30x30 F2.5F2.5 30x30 F2.5F2.5 30x30 F2.5F2.5 30x30 F2.5F2.5 30x30 F2.5F2.5 30x30 F2.5F2.5 30x30 F2.5F2.5 30x30 F2.5F2.5 30x30 GRADE BEAM:GRADE BEAM: 12" WIDE x 12" THICK W/ (2) #4 CONT. TOP & BOTTOM. GRADE BEAM:GRADE BEAM: 12" WIDE x 12" THICK W/ (2) #4 CONT. TOP & BOTTOM. GRADE BEAM:GRADE BEAM: 12" WIDE x 12" THICK W/ (2) #4 CONT. TOP & BOTTOM. GRADE BEAM:GRADE BEAM: 12" WIDE x 12" THICK W/ (2) #4 CONT. TOP & BOTTOM. GRADE BEAM:GRADE BEAM: 12" WIDE x 12" THICK W/ (2) #4 CONT. TOP & BOTTOM. GRADE BEAM:GRADE BEAM: 12" WIDE x 12" THICK W/ (2) #4 CONT. TOP & BOTTOM. GRADE BEAM:GRADE BEAM: 12" WIDE x 12" THICK W/ (2) #4 CONT. TOP & BOTTOM. GRADE BEAM:GRADE BEAM: 12" WIDE x 12" THICK W/ (2) #4 CONT. TOP & BOTTOM. NOTE:NOTE: PROVIDE 4 1/2" MIN. CURB HEIGHT, FROM TOP OF SLAB TO TOP OF CURB, TYP. ALL OPENINGS. F2.5F2.5 30x30 F2.5F2.5 30x30 F2.5F2.5 30x30 F2.5F2.5 30x30 HDU4SSTB20HDU4SSTB20HDU4SSTB20HDU4SSTB20HDU4SSTB20HDU4SSTB20HDU4SSTB20HDU4SSTB20HDU4SSTB20HDU4SSTB20H DU 8S S T B28H D U8 S S T B 2 8 HDU8SSTB28HDU8SSTB28 TRUSSES @ 24" c/cTRUSSES @ 24" c/c DESIGN & CALCS BY OTHERS GRAVEL FILL 4" CONCRETE SLAB SCALE: 1/4" = 1'-0" SECTION A-2A 2 A 2 FOUNDATION DETAILS:FOUNDATION DETAILS: SEE STRUCTURAL PAGES FOR DETAILS STUCCO WEEP SCREEDS:STUCCO WEEP SCREEDS: INSTALL 2" ABOVE PAVED AREAS. INSTALL 4" ABOVE SOIL. 26 GUAGE MINIMUM CRC R703.7.2.1. 3 COAT STUCCO:3 COAT STUCCO: APPLIED OVER 2 LAYERS OF GRADE D PAPER. FASCIA & GUTTER:FASCIA & GUTTER: CONNECT TO 2"x3" DOWNSPOUTS ROOF VENTILATION:ROOF VENTILATION: SEE ROOF PLAN & ROOF VENTILATION CALCS. NOT REQUIRED. CONTINUOUS RIDGE VENT COMPOSITION ROOFING:COMPOSITION ROOFING: OVER 15# FELT OVER 1/2" CDX PLYWOOD OR OSB WITH 8d'S AT 6", 12" c/c. PITCH 6 / 1PITCH 6 / 12 2" x 6" STUDS @ 16" c/c 14' PLATE HEIGHT 4" CONCRETE SLAB4" CONCRETE SLAB UNCOVERED WALLS & CEILINGUNCOVERED WALLS & CEILING © COPYRIGHT 2023 SHEET 2640 SHOWN 5/6/2024 SCALE: DATE:DARRON & KRISTIANE RANSBARGERDARRON & KRISTIANE RANSBARGER5046 SAN JUANICO DRIVE, CHICO, CALIFORNIA 95973ASSESSORS PARCEL NUMBER 047 - 440 - 075A CARPORT / COVERED PATIO for:G.S.M. CONSTRUCTIONSUMMIT STRUCTURAL DESIGN - STRUCTURAL ENGINEER383 RIO LINDO AVENUE #200, CHICO, CA 95926(530) 592-4407 WORK EMAIL ADDRESS: Ryland@SummitChico.com ARCH D (24" x 36") 1 STORY THESE PLANS HAVE BEENREVIEWED ONLY FORCOMPLIANCE WITH ATTACHEDSTRUCTURAL CALCULATIONS. THE ENGINEER'S STAMP ON THIS PLAN IS VALID ONLY WITH A LETTER SIGNED BY THISENGINEER FOR EACHUNIQUE BUILD. 2 C:/Users/Lynn/OneDrive/Documents/Chief X15 Plans/Gareth Munoz - Ransbarger Patio/RansbargerPatio.layoutOWNER: DARRON & KRISTIANE RANSBARGER(530) 966-2336 CELLEMAIL ADDRESS: Darron.Ransbarger@GMail.com MAX RAMIREZ - GOLDEN SUN DESIGN - ENERGY CALCS22189 SAMSON AVENUE, CORNING, CALIFORNIA 96021PHONE: (530) 321-7242 CELLEMAIL ADDRESS: AlphaMax47@GMail.com WHILE EVERY ATTEMPT HASBEEN MADE IN THEPREPARATION OF THIS PLANTO AVOID MISTAKES, THE MAKER CANNOT GUARANTEE AGAINST HUMAN ERROR. BUILDING CONTRACTOR / HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. LYNN SMITH - DRAFTING199 SYCAMORE VALLEY ROAD, CHICO, CA 95973(530) 891-0585 WORK EMAIL ADDRESS: LynnSmith32@ATT.net (E) LIVABLE(E) LIVABLE:: 4027 SqFt (E) TOTAL4027 SqFt (E) TOTAL (E) GARAGE(E) GARAGE:: 1293 SqFt (E) TOTAL1293 SqFt (E) TOTAL CARPORTCARPORT & COVERED& COVERED PATIOSPATIOS:: 2161 SqFt EXIST 2640 SqFt NEW 4801 SqFt TOTAL4801 SqFt TOTAL 2023GSM CONSTRUCTIONGARETH MUNOZ (530) 591-0111EMAIL ADDRESS: GarethMunoz@GMail.com FOUNDATION PLANSECTION A-25/6/2024 D.S. TOYARDDRAIN D.S. TOYARDDRAIN D.S. TOYARDDRAIN D.S. TOYARDDRAIN DORMER VENT DORMER VENT DORMER VENT DORMER VENT DORMER VENT DORMER VENT DORMER VENT DORMER VENT DORMER VENT DORMER VENTDORMER VENT24" 24"24"PITCH 6 / 12 1) ROOF COVERING SHALL BE COMPOSITION ROOFING OVER 15# FELT OVER 1/2" CDX PLYWOOD OR OSB WITH 8d'S AT 6", 12" c/c. 2) ROOF PITCH SHALL BE 6:12, TYPICAL. 3) ROOF OVERHANG SHALL BE 24" AT OVERHANG & 24" AT GABLE ENDS, UNLESS OTHERWISE NOTED. 4) NOTE: THIS BUILDING HAS NO INTERIOR FINISHES, THEREFORE NO ATTIC VENTILATION IS REQUIRED. THE CALCULATION BELOW WOULD BE REQUIRED IF THE INTERIOR WERE FINISHED. SCALE: 1/4" = 1'-0" ROOF PLAN LEGEND:LEGEND: 9.5'RIDGE LENGTHRIDGE LENGTH 26.0' 2640 SQFT OF ATTIC 150 DIVIDED BY 150 17.6017.60 SQFT OF REQUIRED NET FREE VENTILATION AREA (NFVA)SQFT OF REQUIRED NET FREE VENTILATION AREA (NFVA) _________________________________________________________________________ RIDGE VENTSRIDGE VENTS 3.25 SQFT - (26) LIN FT OR-4 RIDGE VENT (18.0 SQ IN/LIN FT) = 0.125 SQFT/LIN FT BY LOMANCO OMNI SERIES OR EQ. BY LOMANCO OMNI SERIES OR EQ. ROOF TOP VENTSROOF TOP VENTS 5.72 SQFT - (11) 2"x32" O'HAGIN LOW PROFILE COMP COMP EYEBROW 72.0 SQ IN EACH)   = 0.52 SQFT BY O'HAGIN MFG, LLC OR EQ.BY O'HAGIN MFG, LLC OR EQ. 8.97 8.97 SQFT OF UPPER NFVA SQFT OF UPPER NFVA _________________________________________________________________________ CONTINUOUS EAVE VENTS - CONTINUOUS EAVE VENTS - NOT IN A W.U.I.NOT IN A W.U.I. 8.40 SQFT - (150) LIN FT CONT. EAVE VENT (8 SQ IN/LIN FT) = 0.056 SQFT/FT BY CONSTRUCTION METALS OR EQUAL BY CONSTRUCTION METALS OR EQUAL 8.40 8.40 SQFT OF LOWER NFVASQFT OF LOWER NFVA _________________________________________________________________________ 17.37 17.37 TOTAL SQFT OF VENTS (NFVA)TOTAL SQFT OF VENTS (NFVA) 6 : 12 PITCH 6 : 12 PITCH6 : 12PITCH6 : 12PITCHROOF PLAN STRUCTURAL NOTES:ROOF PLAN STRUCTURAL NOTES: 1.)       SEE TYPICAL NOTE SHEET SN AND TYPICAL DETAIL             SHEETS SD1-SD2 FOR ADDITIONAL INFORMATION. 2.)       TYPICAL ROOF SHEATHING (UNO): 1/2" THICK, APA,             TECO, OR PITTSBURGH RATED SHEATHING, SPAN             RATING 32/16, EXPOSURE 1 STRUCTURAL PANELS,             APPLIED WITH LONG DIMENSION ACROSS SUPPORTS             AND ADJACENT PANELS STAGGERED WITH 4' ENDS             OFFSET 4'. EDGE NAIL WITH 8d COMMON OR             EQUIVALENT (0.131" DIA X 2 1/2") AT 6" O.C. AT             ALL PANEL EDGES, BOUNDARIES, GABLE ENDS,             BLOCKING AND WHERE INDICATED ON PLAN. FIELD             NAIL AT 12" O.C. PROVIDE 1/8" GAP AT ALL PANEL             EDGES U.N.O. BY PANEL MANUFACTURER.             RECOMMEND (1) PANEL CLIP MIN. BETWEEN SUPPORTS AT ABUTTING PANEL EDGES. 3.)       SEE NOTE SECTION 8-SN FOR ROOF TRUSSES BY             OTHERS. 4.)       PROVIDE 4X POST MIN. U.N.O. AT ALL BEAM AND GIRDER TRUSS BEARING POINTS AND CONTINUE IN WALL TO FOUNDATION. 5.)       ANY DISCREPANCIES BETWEEN FRAMING SHOWN AND             FIELD CONDITIONS SHALL BE IMMEDIATELY BROUGHT             TO THE ENGINEER OF RECORD. 6.)       ALL FRAMING EXPOSED TO WEATHER, WITHOUT ADEQUATE PROTECTION, SHALL BE PRESSURE             TREATED WITH TREATMENT PROCESS AND             APPLICATION APPROPRIATE FOR EXPOSURE             ACCORDING TO MFR'S WRITTEN GUIDELINES. 7.)       ROOF TRUSS LAYOUT SHALL BE REVIEWED BY ENGINEER             AS TRUSS DESIGNS BECOME AVAILABLE FROM TRUSS             MANUFACTURER. CONTRACTOR SHALL OBTAIN SIGNED             TRUSS REVIEW LETTER FROM THE ENGINEER OF RECORD             AND BUILDING DEPARTMENT APPROVAL PRIOR TO             CONSTRUCTION. 8.)       CONTRACTOR TO VERIFY THE LOCATION AND LOADING             OF ALL TRUSS TO TRUSS BRACING AND MECHANICAL     CONNECTIONS. IMMEDIATELY NOTIFY TRUSS COMPANY OF ANY DISCREPANCIES. 9.)       ALL STRUCTURAL MEMBERS SHALL BE FASTENED IN      COMPLIANCE WITH 2022 CBC FASTENING SCHEDULE,     TABLE 2304.10.2, UNLESS NOTED OTHERWISE. 10.)    VERIFY ALL ELEVATIONS, STEPS, DIMENSIONS, RAKE             BREAKS, SLOPES, HIPS AND VALLEYS WITH ARCHITECT/DESIGNER. 11.)    PROVIDE (1) H2.5T CLIP AT EACH TRUSS BEARING AND (2) H2.5T CLIPS AT EACH MULTI-PLY OR DRAG TRUSS BEARING, U.N.O. 7 SD2 7 SD2 TYP. GIRDER TRUSSGIRDER TRUSS: TYP. U.N.O. 5 1/4" x 11 1/4 LVL5 1/4" x 11 1/4 LVL5 1/4" x 11 1/4 LVL5 1/4" x 11 1/4 LVL 5 1/4" x 11 1/4 LVL 5 1/4" x 11 1/4 LVL 5 1/4" x 11 1/4 LVL 5 1/4" x 11 1/4 LVL 6"x8" DF#2 6"x8" DF#2 6"x8" DF#2 6"x8" DF#2 6"x8" DF#2 PROVIDE THE ABOVE ATTIC VENTS ATTIC VENTILATION CALCULATIONS © COPYRIGHT 2023 SHEET 2640 SHOWN 5/6/2024 SCALE: DATE:DARRON & KRISTIANE RANSBARGERDARRON & KRISTIANE RANSBARGER5046 SAN JUANICO DRIVE, CHICO, CALIFORNIA 95973ASSESSORS PARCEL NUMBER 047 - 440 - 075A CARPORT / COVERED PATIO for:G.S.M. CONSTRUCTIONSUMMIT STRUCTURAL DESIGN - STRUCTURAL ENGINEER383 RIO LINDO AVENUE #200, CHICO, CA 95926(530) 592-4407 WORK EMAIL ADDRESS: Ryland@SummitChico.com ARCH D (24" x 36") 1 STORY THESE PLANS HAVE BEENREVIEWED ONLY FORCOMPLIANCE WITH ATTACHEDSTRUCTURAL CALCULATIONS. THE ENGINEER'S STAMP ON THIS PLAN IS VALID ONLY WITH A LETTER SIGNED BY THISENGINEER FOR EACHUNIQUE BUILD. 3 C:/Users/Lynn/OneDrive/Documents/Chief X15 Plans/Gareth Munoz - Ransbarger Patio/RansbargerPatio.layoutOWNER: DARRON & KRISTIANE RANSBARGER(530) 966-2336 CELLEMAIL ADDRESS: Darron.Ransbarger@GMail.com MAX RAMIREZ - GOLDEN SUN DESIGN - ENERGY CALCS22189 SAMSON AVENUE, CORNING, CALIFORNIA 96021PHONE: (530) 321-7242 CELLEMAIL ADDRESS: AlphaMax47@GMail.com WHILE EVERY ATTEMPT HASBEEN MADE IN THEPREPARATION OF THIS PLANTO AVOID MISTAKES, THE MAKER CANNOT GUARANTEE AGAINST HUMAN ERROR. BUILDING CONTRACTOR / HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. LYNN SMITH - DRAFTING199 SYCAMORE VALLEY ROAD, CHICO, CA 95973(530) 891-0585 WORK EMAIL ADDRESS: LynnSmith32@ATT.net (E) LIVABLE(E) LIVABLE:: 4027 SqFt (E) TOTAL4027 SqFt (E) TOTAL (E) GARAGE(E) GARAGE:: 1293 SqFt (E) TOTAL1293 SqFt (E) TOTAL CARPORTCARPORT & COVERED& COVERED PATIOSPATIOS:: 2161 SqFt EXIST 2640 SqFt NEW 4801 SqFt TOTAL4801 SqFt TOTAL 2023GSM CONSTRUCTIONGARETH MUNOZ (530) 591-0111EMAIL ADDRESS: GarethMunoz@GMail.com ROOF PLANATTIC VENTILATION CALCSTRUSS LAYOUT SHEET5/6/2024 120120120120120120120120 40W LED SEE ELECT. NOTES, EXT. LIGHTING 40W LED SEE ELECT. NOTES, EXT. LIGHTING 40W LED SEE ELECT. NOTES, EXT. LIGHTING 40W LED SEE ELECT. NOTES, EXT. LIGHTING 40W LED SEE ELECT. NOTES, EXT. LIGHTING DORMER VENT DORMER VENT DORMER VENT D.S. TOYARDDRAIN DORMER VENT DORMER VENT DORMER VENT D.S. TOYARDDRAIN FRONT ELEVATION SCALE: 1/4" = 1'-0" TRUSSES @ 24" c/cTRUSSES @ 24" c/c DESIGN & CALCS BY OTHERS 3 COAT STUCCO:3 COAT STUCCO: 3/4" THICK, APPLIED OVER 2 LAYERS OF GRADE D PAPER. FASCIA & GUTTER:FASCIA & GUTTER: CONNECT TO 2"x3" DOWNSPOUTS, CONFIRM. ROOF VENTILATION:ROOF VENTILATION: SEE ROOF PLAN & ROOF VENTILATION CALCS. CONTINUOUS RIDGE VENT STUCCO WEEP SCREEDS:STUCCO WEEP SCREEDS: INSTALL 2" ABOVE PAVED AREAS. INSTALL 4" ABOVE SOIL. 26 GAUGE MINIMUM CRC R703.7.2.1. COMPOSITION ROOFING:COMPOSITION ROOFING: OVER 15# FELT OVER 1/2" CDX PLYWOOD OR OSB WITH 8d'S AT 6", 12" c/c. PITCH 6 / 1PITCH 6 / 12 120120120120120120120120 40W LED SEE ELECT. NOTES, EXT. LIGHTING 40W LED SEE ELECT. NOTES, EXT. LIGHTING 40W LED SEE ELECT. NOTES, EXT. LIGHTING 40W LED SEE ELECT. NOTES, EXT. LIGHTING 40W LED SEE ELECT. NOTES, EXT. LIGHTING DORMER VENT DORMER VENT DORMER VENT D.S. TOYARDDRAIN DORMER VENT DORMER VENT DORMER VENT D.S. TOYARDDRAIN 120120120120120120120120 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING DORMER VENT DORMER VENTDORMER VENTDORMER VENT DORMER VENT DORMER VENT D.S. TOYARDDRAIN D.S. TOYARDDRAIN REAR ELEVATION SCALE: 1/4" = 1'-0" TRUSSES @ 24" c/cTRUSSES @ 24" c/c DESIGN & CALCS BY OTHERS 3 COAT STUCCO:3 COAT STUCCO: 3/4" THICK, APPLIED OVER 2 LAYERS OF GRADE D PAPER. FASCIA & GUTTER:FASCIA & GUTTER: CONNECT TO 2"x3" DOWNSPOUTS, CONFIRM. ROOF VENTILATION:ROOF VENTILATION: SEE ROOF PLAN & ROOF VENTILATION CALCS. CONTINUOUS RIDGE VENT STUCCO WEEP SCREEDS:STUCCO WEEP SCREEDS: INSTALL 2" ABOVE PAVED AREAS. INSTALL 4" ABOVE SOIL. 26 GAUGE MINIMUM CRC R703.7.2.1. COMPOSITION ROOFING:COMPOSITION ROOFING: OVER 15# FELT OVER 1/2" CDX PLYWOOD OR OSB WITH 8d'S AT 6", 12" c/c. PITCH 6 / 1PITCH 6 / 12 120120120120120120120120 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING DORMER VENT DORMER VENTDORMER VENTDORMER VENT DORMER VENT DORMER VENT D.S. TOYARDDRAIN D.S. TOYARDDRAIN 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING 40W LED SEE ELECT. NOTES, EXT. LIGHTING 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING DORMER VENT D.S. TOYARDDRAIN DORMER VENT DORMER VENT D.S. TOYARDDRAIN LEFT SIDE ELEVATION SCALE: 1/4" = 1'-0" TRUSSES @ 24" c/cTRUSSES @ 24" c/c DESIGN & CALCS BY OTHERS 3 COAT STUCCO:3 COAT STUCCO: 3/4" THICK, APPLIED OVER 2 LAYERS OF GRADE D PAPER. LANDINGS:LANDINGS: SEE NOTES: LANDINGS. FASCIA & GUTTER:FASCIA & GUTTER: CONNECT TO 2"x3" DOWNSPOUTS, CONFIRM. ROOF VENTILATION:ROOF VENTILATION: SEE ROOF PLAN & ROOF VENTILATION CALCS. CONTINUOUS RIDGE VENT STUCCO WEEP SCREEDS:STUCCO WEEP SCREEDS: INSTALL 2" ABOVE PAVED AREAS. INSTALL 4" ABOVE SOIL. 26 GAUGE MINIMUM CRC R703.7.2.1. COMPOSITION ROOFING:COMPOSITION ROOFING: OVER 15# FELT OVER 1/2" CDX PLYWOOD OR OSB WITH 8d'S AT 6", 12" c/c. PITCH 6 / 1PITCH 6 / 12 LANDINGS:LANDINGS: SEE NOTES: LANDINGS. 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING 40W LED SEE ELECT. NOTES, EXT. LIGHTING 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING DORMER VENT D.S. TOYARDDRAIN DORMER VENT DORMER VENT D.S. TOYARDDRAIN 3050SC DORMER VENT D.S. TOYARDDRAIN 4020FX4020FX4020FX 4020FX4020FX 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING 40W LED SEE ELECT. NOTES, EXT. LIGHTING 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING DORMER VENT D.S. TOYARDDRAIN RIGHT SIDE ELEVATION SCALE: 1/4" = 1'-0" TRUSSES @ 24" c/cTRUSSES @ 24" c/c DESIGN & CALCS BY OTHERS 3 COAT STUCCO:3 COAT STUCCO: 3/4" THICK, APPLIED OVER 2 LAYERS OF GRADE D PAPER. LANDINGS:LANDINGS: SEE NOTES: LANDINGS. FASCIA & GUTTER:FASCIA & GUTTER: CONNECT TO 2"x3" DOWNSPOUTS, CONFIRM. ROOF VENTILATION:ROOF VENTILATION: SEE ROOF PLAN & ROOF VENTILATION CALCS. CONTINUOUSRIDGE VENT STUCCO WEEP SCREEDS:STUCCO WEEP SCREEDS: INSTALL 2" ABOVE PAVED AREAS. INSTALL 4" ABOVE SOIL. 26 GAUGE MINIMUM CRC R703.7.2.1. COMPOSITION ROOFING:COMPOSITION ROOFING: OVER 15# FELT OVER 1/2" CDX PLYWOOD OR OSB WITH 8d'S AT 6", 12" c/c. PITCH 6 / 1PITCH 6 / 12 14' PLATEHEIGHT LANDINGS:LANDINGS: SEE NOTES: LANDINGS. 3050SC DORMER VENT D.S. TOYARDDRAIN 4020FX4020FX4020FX 4020FX4020FX 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING 40W LED SEE ELECT. NOTES, EXT. LIGHTING 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING DORMER VENT D.S. TOYARDDRAIN © COPYRIGHT 2023 SHEET 2640 SHOWN 5/6/2024 SCALE: DATE:DARRON & KRISTIANE RANSBARGERDARRON & KRISTIANE RANSBARGER5046 SAN JUANICO DRIVE, CHICO, CALIFORNIA 95973ASSESSORS PARCEL NUMBER 047 - 440 - 075A CARPORT / COVERED PATIO for:G.S.M. CONSTRUCTIONSUMMIT STRUCTURAL DESIGN - STRUCTURAL ENGINEER383 RIO LINDO AVENUE #200, CHICO, CA 95926(530) 592-4407 WORK EMAIL ADDRESS: Ryland@SummitChico.com ARCH D (24" x 36") 1 STORY THESE PLANS HAVE BEENREVIEWED ONLY FORCOMPLIANCE WITH ATTACHEDSTRUCTURAL CALCULATIONS. THE ENGINEER'S STAMP ON THIS PLAN IS VALID ONLY WITH A LETTER SIGNED BY THISENGINEER FOR EACHUNIQUE BUILD. 4 C:/Users/Lynn/OneDrive/Documents/Chief X15 Plans/Gareth Munoz - Ransbarger Patio/RansbargerPatio.layoutOWNER: DARRON & KRISTIANE RANSBARGER(530) 966-2336 CELLEMAIL ADDRESS: Darron.Ransbarger@GMail.com MAX RAMIREZ - GOLDEN SUN DESIGN - ENERGY CALCS22189 SAMSON AVENUE, CORNING, CALIFORNIA 96021PHONE: (530) 321-7242 CELLEMAIL ADDRESS: AlphaMax47@GMail.com WHILE EVERY ATTEMPT HASBEEN MADE IN THEPREPARATION OF THIS PLANTO AVOID MISTAKES, THE MAKER CANNOT GUARANTEE AGAINST HUMAN ERROR. BUILDING CONTRACTOR / HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. LYNN SMITH - DRAFTING199 SYCAMORE VALLEY ROAD, CHICO, CA 95973(530) 891-0585 WORK EMAIL ADDRESS: LynnSmith32@ATT.net (E) LIVABLE(E) LIVABLE:: 4027 SqFt (E) TOTAL4027 SqFt (E) TOTAL (E) GARAGE(E) GARAGE:: 1293 SqFt (E) TOTAL1293 SqFt (E) TOTAL CARPORTCARPORT & COVERED& COVERED PATIOSPATIOS:: 2161 SqFt EXIST 2640 SqFt NEW 4801 SqFt TOTAL4801 SqFt TOTAL 2023GSM CONSTRUCTIONGARETH MUNOZ (530) 591-0111EMAIL ADDRESS: GarethMunoz@GMail.com EXTERIOR ELEVATIONS TV 3 3 RR4RREP T CO/SDSD GFCIWP GFCI+48" GFCIWP GFCI GD WP A OCAV CONTROLDC DRYER WASHERGFCI DISHWASHER ELECTRANGE GASC.T. GASRANGE HOODVENT MICROWAVE RECESS +60" GFCI GFCI +60" GFCIWP +60" GFCIWP HUM.VAC GASSERVICE 225A ELECT.SERVICEDISCONNECTVACDOOR BELL HOMESECURITY ALARMINTERCOMDIMDIM9WMINI7WL.V.PENSCOCCEXHAUST FAN/LIGHT 11W LED LIGHTSEE ELECT. NOTES:EXHAUST FANS. 10W LEDWEIGHTEDPENDANT 30W LED W.I.CANDELABRA 30W LED48" TRACK10W LED PIVOTREADING 10W LEDSWING ARM READING10W LED SWIVELREADING6W LED PATH48" 14W TUBE9WL.V. 3W PKABOVE24" 8W TUBE36" 10W TUBE65W LEDPENDANT30W LEDPENDANT40W LEDPENDANT30W LEDPENDANT26W LEDPENDANT24W LEDPENDANT22W LEDKEYLESS 10WKEYLESS W/ P.C. 10W11W LED14WLED14W LEDEYEBALL4WL.V.DUALSPOT40WDECOSPOT19WTRIPOD SPOT 19W 14W LED24" TRACK30W LED CABLE LIGHTING26W LED TRACK LIGHTING 24W LED TRACK CHANDELIER96" 2 TUBE FLUORESCENT SHOPLIGHT - 60WFLUORESCENT SHOP - 32W48" - 32W - 2 TUBE LED64W - 4 TUBE LED96" (2) TUBE FLUORESCENT - 60W 40W LEDSEE ELECT. NOTES, LIGHTS.8W LED BOWLSCONCE16W LED BOWLSCONCE24W LED BOWLSCONCE32W LED BOWLSCONCE9W LEDSCONCE7W LED ART LIGHT 24W LEDLIGHT BAR24W LED V. LIGHT BAR 40W LED DUAL SPOT SEE ELECT. NOTES, LIGHTS40W LED SPOTS W/ MOTION SEE NOTES, LIGHTS8W LED BOX8W LED FLARE6W LED PATH6W LED TULIP4W LED SPOT SUBPANELTHERMOSTATCO/SMOKE DETECT'RSEE ELECT. NOTES:SMOKE/CO ALARMSSMOKE DETECTORSEE ELECT. NOTES:SMOKE/CO ALARMsCEILING FAN W/ LIGHT SEE ELECT. NOTES: CEILING FANS. 17W LED LIGHTSSEE ELECT. NOTES: LAMP HOLDERS.CEILING FAN W/ LIGHT SEE ELECT. NOTES: CEILING FANS 17W LED LIGHTS SEE ELECT. NOTES: LAMP. HOLDERSEXHAUST FAN 50 CFMSEE ELECT. NOTES:EXHAUST FANS. EXHAUST FANSEE ENERGY I.A.Q. 1 SONE MAX. "VENT CONTROL" EXHAUST/LIGHT/HEAT11W LED LT - 1400W HT SEE ELECT. NOTES: EXHAUST FANSPHONECHRISTMASLIGHTS, SEEELECT. NOTES:CHRISTMASLIGHTS+48" 110vCONFIRM220v220VW.H.FANVENT CNTRL3W PKIN CAB.3WPK50W LEDPENDANT50W LEDPENDANT50W LEDPENDANT40W LEDSEE ELECT.NOTES, EXT.LIGHTINGDARK SKYCOMPLIANT.220 VOLT:220 VOLT: 220v, WEATHERPROOF 220vSYMBOLDESCRIPTIONEXHAUST FAN, EXHAUST FAN W/ LIGHT &EXHAUST FAN W/ LIGHT & HEAT.LAUNDRY ROOM OR (1) BATHROOM FANW/ A MAX. NOISE RATING OF 1 SONE. THESWITCH SHALL BE LABELED "VENTILATIONCONTROL". SEE ENERGY CALCS FORCFM MIN. EACH BATHROOM FAN SHALL BE 50 CFMMIN. W/ A NOISE RATING OF 3 SONE MAX.BATHROOM FANS MUST BE HUMIDISTATCONTROLLED CAPABLE OF ADJUSTMENTBETWEEN A RELATIVE HUMIDITY RANGEOF 50% TO 80%. CGBSC SEC. 4.506BASEBOARD HEAT.CAT5 W/ TV, PHONE & TV JACKSAPPLIANCESAPPLIANCES::DRYER, WASHER, DISHWASHER, ELECT.RANGE, DISPOSAL, GAS COOKTOP, HOODW/ VENT, MICROWAVE, OVEN,REFRIGERATOR, SAUNA, STEAM, TOWELWARMER, TRASH COMPACTOR110 VOLT:110 VOLT: CHRISTMAS WEATHERPROOFDUPLEX, CLOSET DUPLEX, DUPLEX W/ USB,DUPLEX, DUPLEX SPLIT WIRED, RECESSEDDUPLEX, GFCI, GARAGE GFCI, GFCI FOR TV+60" (WHEN NEEDED), DUPLEX FOR TV+60", WEATHERPROOF DUPLEX, CEILINGMOUNTED GARAGE DUPLEX & FLOORDUPLEX. ALL SHALL BE TAMPERRESISTANT. SWITCHES:SWITCHES: AIR SWITCH, DISPOSAL,OCCUPANCY, HUMIDISTAT, SWITCH,VACANCY SENSOR, DIMMER, SPEEDCONTROL, WHOLE HOUSE FAN, 3-WAY, 3-WAY DIMMER, TIMER, WATERPROOF &HUMIDISTAT SWITCH LABELED"VENTILATION CONTROL". NOTENOTE: : NOT ALL3-WAY & 4-WAY DESIGNATIONS ARESHOWN.ELECTRICAL LEGENDVACUUM OUTLET & WALL MOUNTEDCENTRAL VACUUM SYSTEMCABINET MOUNTED LIGHTING:CABINET MOUNTED LIGHTING: ABOVE CABINET PUCK, UNDER CABINETPUCK, PUCK IN CABINET, UNDER CABINETTUBE & LV TAPE LIGHTING.RECESSED CEILING LIGHTINGRECESSED CEILING LIGHTING:: MINI RECESSED, 4" CAN LIGHT, 6" CANLIGHT & EYEBALL CAN LIGHT.CEILING MOUNTED LIGHTING: CEILING MOUNTED LIGHTING: CEILINGFIXTURE, KEYLESS, KEYLESS W/ PULLCHORD, DUAL SPOT, TRIPOD SPOT LIGHT &DECORATIVE SPOT LIGHT.CHANDELIER LIGHTINGCHANDELIER LIGHTINGPENDANT LOW VOLTAGE LIGHTINGPENDANT LOW VOLTAGE LIGHTINGTRACK LIGHTINGTRACK LIGHTINGTUBE LIGHTINGTUBE LIGHTINGWALL MOUNTED SCONCE LIGHTINGWALL MOUNTED SCONCE LIGHTINGWALL ART LIGHTINGWALL ART LIGHTINGLIGHT BARSLIGHT BARSEXTERIOR WALL LIGHTINGEXTERIOR WALL LIGHTING& PATHWAY YARD LIGHTS& PATHWAY YARD LIGHTSWALL READING LAMPSWALL READING LAMPSELECTRICAL SERVICE METER, GASSERVICE METER, ELECTRICALDISCONNECT, SUB PANEL, DOOR CHIME,DOOR BELL, SETBACK THERMOSTAT,HOME SECURITY ALARM, AUDIO VISUALCONTROL, CO/SMOKE DETECTOR &SMOKE DETECTOR. ALL HARDWIREDSMOKE/CO DETECTORS SHALL BEINTERCONNECTED.CEILING FANSCEILING FANS::A FIXTURE THAT WEIGHS MORE THAN 6 LBS OR EXCEEDS 16" IN ANY DIMENSIONSHALL NOT BE SUPPORTED BY THESCREW SHELL OF A LAMP HOLDER. CECSECTION 410.15 (A).OUTLET BOXES SHALL NOT BE USED ASTHE SOLE SUPPORT. CEC SECTION 314.27NOTENOTE: : PROVIDE SPEED CONTROL SWITCH& DIMMER SWITCH FOR FANS THAT HAVELIGHT KITS.2/22/2022DOOR CHIME CO/SD CAT7+60" CAT7 CAT6+60" CAT6 DISPOSAL USB 1/2 HOT TV +60"VACXMASTIMERTIMER CENTRAL VACUUM LV TAPE 1.4W - 4W/ FOOTLV TAPE 1.4W - 4W/ FOOT 200W 200WBASEB'DBASEB'D HEAT HEATTRASHCOMP TOWELWARMER STEAM SPA SAUNA REF 220v DOUBLEOVEN 220v OVEN 48" - 32W - 2 TUBE LED 48" - 32W - 2 TUBE LED 48" - 32W - 2 TUBE LED 48" - 32W - 2 TUBE LED 48" - 32W - 2 TUBE LED 48" - 32W - 2 TUBE LED 48" - 32W - 2 TUBE LED 48" - 32W - 2 TUBE LED 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING 40W LED SPOTS W/ MOTION SEE ELECT. NOTES, EXT. LIGHTING 40W LED SEE ELECT. NOTES, EXT. LIGHTING 40W LED SEE ELECT. NOTES, EXT. LIGHTING 40W LED SEE ELECT. NOTES, EXT. LIGHTING 40W LED SEE ELECT. NOTES, EXT. LIGHTING 40W LED SEE ELECT. NOTES, EXT. LIGHTING GFCITOP 48" EP SUBPANEL WP WP WP WPWP EXTERIOR LIGHTING:EXTERIOR LIGHTING: SEE ELECTRICAL NOTES: EXTERIOR, EXTERIOR LIGHTING. SEE ELECTRICAL NOTES:SEE ELECTRICAL NOTES: "ALL AREAS" FOR MANDATORY MEASURES. ALL LIGHTING FIXTURES:ALL LIGHTING FIXTURES: ALL LIGHTING SHALL BE L.E.D. ALL RECESSED LIGHTING:ALL RECESSED LIGHTING: THAT ARE NOT CONTROLLED BY OCCUPANCY OR VACANCY SENSORS, SHALL HAVE DIMMING CONTROLS & MUST BE AIR TIGHT & INSULATION CONTACT RATED. CEnC 150.0.K.2.F ELECTRICAL PLAN SCALE: 1/4" = 1'-0" ELECTRICAL NOTES ELECTRICAL SHALL BE INSTALLED PER 2022 C.E.C.:ELECTRICAL SHALL BE INSTALLED PER 2022 C.E.C.: ALL AREASALL AREAS:: REFER TO THE MANDATORY MEASURESMANDATORY MEASURES FOR RESIDENTIAL LIGHTING MEASURESRESIDENTIAL LIGHTING MEASURES ATTACHED TO THE ENERGY COMPLIANCE DOCUMENTATION. THE LUMINARY FIXTURE TYPE OR CONTROL TYPE SHALL COMPLY WITH THE MANDATORY ENERGY LIGHTING REQUIREMENTS THROUGHOUT. AGING-IN-PLACEAGING-IN-PLACE:: ELECTRICAL RECEPTACLE OUTLETS, SWITCH & CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION & AIR-CONDITIONING) INTENDED TO BE USED BY OCCUPANTS, SHALL BE LOCATED NO MORE THAN 48" MEASURED FROM THE TOP OF THE BOX & NOT LESS THAN 15" MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISHED FLOOR. CRC R327.1.2. EXCEPTIONSEXCEPTIONS:: DEDICATED RECEPTACLE & FLOOR RECEPTACLE OUTLETS; CONTROLS MOUNTED ON CEILING FANS & CEILING LIGHTS; & CONTROLS LOCATED ON APPLIANCES. RECEPTACLE OUTLETS REQUIRED BY THE CEC ON A WALL SPACE WHERE THE DISTANCE BETWEEN THE FINISHED FLOOR & THE BUILT-IN FEATURE ABOVE THE FINISHED FLOOR, SUCH AS A WINDOW, IS LESS THAN 15". ATTICATTIC: : PROVIDE A PERMANENT120v RECEPTACLE & SWITCH CONTROLLED LIGHT(S) NEAR THE ATTIC MECHANICAL EQUIPMENT FOR MAINTENANCE. THE LIGHT SWITCH SHALL BE LOCATED NEAR THE ATTIC ACCESS. CPC 508.4.4. APPLIANCESAPPLIANCES: : RECEPTACLES FOR A SPECIFIC APPLIANCE SHALL BE LOCATED WITHIN 6' OF THE INTENDED LOCATION OF THE APPLIANCE. CEC 210.50.C. ELECTRIC COOKTOP READY SYSTEMSELECTRIC COOKTOP READY SYSTEMS USING GAS OR PROPANE COOKTOP TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING: 1.) A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3' FROM THE COOKTOP AND ACCESSIBLE TO THE COOKTOP WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 50 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS “240V READY.” ALL ELECTRICAL COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH THE CEnC. CENC 150.0U 2.) THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE ELECTRIC COOKTOP INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USE.” CENC 150.0U BATHROOMSBATHROOMS: : RECEPTACLESRECEPTACLES:: SHALL BE SUPPLIED BY ONE OR MORE 20-AMP BRANCH CIRCUIT. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS PER CEC 210.11.C.3. ALL RECEPTACLES MUST HAVE GFCI PROTECTION CEC210.8.A.1. WET LOCATIONSWET LOCATIONS: : LIGHTS INSTALLED IN WET OR DAMP AREAS SHALL BE INSTALLED SUCH THAT WATER CANNOT ENTER OR ACCUMULATE IN WIRING COMPARTMENTS, LAMP HOLDERS, OR OTHER ELECTRICAL PARTS & SHALL BE LABELED "SUITABLE FOR WET LOCATIONS". CEC 410.10.A. RECEPTACLES SHALL NOT BE INSTALLED WITHIN A ZONE MEASURED 3' HORIZONTALLY & 8' VERTICALLY FROM THE TOP OF THE BATHTUB RIM OR SHOWER STALL THRESHOLD. CEC 406.9 (C). SWITCHES SHALL NOT BE INSTALLED WITHIN 3 FEET OF THE PERIMETER OF BATHTUBS OR SHOWER STALLS. CEC 404.4 (C) FANS WITH BUILT-IN HEATERSFANS WITH BUILT-IN HEATERS:: SHALL BE SUPPLIED BY A DEDICATED 30 AMP CIRCUIT & SEPARATE SWITCH. CEC 424.3.A. SINKSSINKS: : AT LEAST ONE 120 VOLT RECEPTACLE IS REQUIRED WITHIN 3' OF OUTSIDE EDGE OF EACH SINK. IN NO CASE CAN IT BE LOCATED MORE THAN 12" BELOW THE TOP OF THE SINK. CEC 210.52.D. BATHROOM LIGHTSBATHROOM LIGHTS: : AT LEAST ONE LIGHT MUST BE CONTROLLED BY AN OCCUPANCY OR VACANCY SENSOR PROVIDING AUTOMATIC-OFF FUNCTIONALITY. CEnC 150.0.K.2.E. BATHROOM MECHANICAL EXHAUST FANSBATHROOM MECHANICAL EXHAUST FANS: : EACH BATHROOM CONTAINING A BATHTUB, SHOWER OR TUB/SHOWER COMBINATION SHALL BE MECHANICALLY VENTILATED WITH ENERGY STAR APPROVED EQUIPMENT WITH AN INTEGRAL HUMIDISTAT INSTALLED. CRC R303.3.1. 1.) EXHAUST FANS SHALL BE SWITCHED SEPARATELY FROM LIGHT SWITCHES CEnC 150.0.K.2.B. 2.) FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING. 3.) UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE READILY ACCESSIBLE. 4.) HUMIDISTAT CONTROLS SHALL BE CAPABLE OF ADJUSTMENTS BETWEEN A RELATIVE HUMIDITY RANGE OF 50% TO 80%. BATHROOM NOTEBATHROOM NOTE:: FOR THE PURPOSES OF THIS NOTE, A BATHROOM IS A ROOM WHICH CONTAINS A BATHTUB, SHOWER OR TUB/SHOWER COMBINATION. BEDROOMS & CLOSETSBEDROOMS & CLOSETS: : SMOKE DETECTORSSMOKE DETECTORS: : PROVIDE A SMOKE DETECTOR IN EACH BEDROOM. SEE SMOKE/CARBON MONOXIDE ALARMS. CRC R314.3. CLOSETS LIGHTS:CLOSETS LIGHTS: MINIMUM CLEARANCE FROM CLOSET STORAGE IS 12" FOR SURFACE MOUNTED COMPLETELY LIGHT ON THE CEILING OR ABOVE THE DOOR & 6" FOR RECESSED LIGHTS CEC 410.16.C. W.I. CLOSETS: PROVIDE OCCUPANCY SENSOR LIGHT SWITCH.W.I. CLOSETS: PROVIDE OCCUPANCY SENSOR LIGHT SWITCH. BRANCH CIRCUITS & RECEPTACLESBRANCH CIRCUITS & RECEPTACLES: : PANEL LOCATIONSPANEL LOCATIONS: : NO ELECTRICAL PANELS SHALL BE LOCATED IN CLOSETS OR BATHROOMS. MAINTAIN A CLEARANCE OF 36" IN FRONT OF PANELS, 30" WIDE (OR WIDTH OF EQUIPMENT, WHICHEVER IS GREATER) & 6'-6" HIGH FOR HEADROOM. CEC 110.26. ELECTRICAL SERVICEELECTRICAL SERVICE: : SEE FLOOR PLAN FOR ELECTRICAL SERVICE MAIN AMPERAGE. VERIFY LOCATION OF MAIN & SUB PANEL. PANEL BOARD(S) SHALL BE PROVIDED W/ A CIRCUIT DIRECTORY OR CIRCUIT IDENTIFICATION. CEC 408.3.F. EACH CIRCUIT & CIRCUIT MODIFICATION SHALL BE LEGIBLY IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC PURPOSE. THE IDENTIFICATION SHALL INCLUDE AN APPROVED DEGREE OF DETAIL THAT ALLOWS EACH CIRCUIT TO BE DISTINGUISHED FROM ALL OTHERS. SPARE CONDITIONS THAT CONTAIN UNUSED OVERCURRENT DEVICES OR SWITCHES SHALL BE DESCRIBED ACCORDINGLY, THE IDENTIFICATION SHALL BE INCLUDED IN A CIRCUIT DIRECTORY THAT IS LOCATED ON THE FACE OR INSIDE OF THE PANEL DOOR IN THE CASE OF A PANEL BOARD & AT EACH SWITCH OR CIRCUIT BREAKER IN A SWITCHBOARD OR SWITCH GEAR. NO CIRCUIT SHALL BE DESCRIBED IN A MANNER THAT DEPENDS ON TRANSIENT CONDITIONS OF OCCUPANCY. BRANCH CIRCUITS:BRANCH CIRCUITS: ALL 125 TO 250-VOLT, SINGLE PHASE, 15 & 20-AMP RECEPTACLES IN THE LOCATIONS SPECIFIED SHALL HAVE (GFCI)(GFCI) GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL. CEC 210.8.A.: BATHROOMS, OUTDOORS, LAUNDRY, BASEMENTS, CRAWL SPACES AT OR BELOW GRADE, INDOOR DAMP AND WET LOCATIONS, KITCHENS WHERE RECEPTACLES ARE INSTALLED TO SERVE THE COUNTERTOP SURFACE AND SINKS, BATHTUBS AND SHOWERS WHERE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF THE OUTSIDE EDGE OF THE SINK, BATHTUB OR SHOWER. ALL 120 TO -VOLT, SINGLE PHASE. 15- AND 20-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS (I.E.: RECEPTACLES LIGHTS, SMOKE DETECTORS. ETC.) INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS. LIVING ROOMS. PARLORS. LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED COMBINATION-TYPE ARC FAULT CIRCUIT INTERRUPTER. INSTALLED TO PROVIDE PROTECTION OF THE ENTIRE BRANCH CIRCUIT. CEC. 210.12.A. UFER GROUNDUFER GROUND: : PROVIDE A 20' LENGTH OF REBAR OR $4 COPPER WIRE ENCASED IN CONCRETE IN THE BOTTOM OF A CONCRETE FOOTING. CEC 250.52.A.3. BOND ALL METAL GAS & WATER PIPES TO GROUND. ALL CLAMPS SHALL BE ACCESSIBLE & OF AN APPROVED TYPE. CEC 250.104. COMBUSTIBLE INSULATION CLEARANCECOMBUSTIBLE INSULATION CLEARANCE:: COMBUSTIBLE INSULATION SHALL BE SEPARATED NOT LESS THAN 3" FROM RECESSED LUMINAIRES, FAN MOTORS & OTHER HEAT-PRODUCING DEVICES. SEE CRC R302.14 FOR EXCEPTIONS. DOORBELL BUTTONSDOORBELL BUTTONS: : DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48" ABOVE THE EXTERIOR FLOOR OR LANDING, MEASURED FROM OF THE TOP OF THE DOOR BELL ASSEMBLY. SEE CRC R327.1.4 FOR ADDITION INFORMATION. ENERGY STORAGE SYSTEMSENERGY STORAGE SYSTEMS: : CEC 150.0.S. ENERGY STORAGE SYSTEMS (ESS) SHALL COMPLY WITH THE PROVISIONS OF CRC R328.1 AND PROTECTED FROM VEHICLE DAMAGE AS PER CRC R328.8.1. 1.) AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED: A.) ESS READY INTERCONNECTION EQUIPMENT WITH A MINIMUM BACKED-UP CAPACITY OF 60 AMPS & A MINIMUM OF FOUR ESS-SUPPLIED BRANCH CIRCUITS, OR B.) A DEDICATED RACEWAY FROM THE MAIN SERVICE TO A SUB-PANEL THAT SUPPLIES THE BRANCH CIRCUITS IN CEC150.0(S)(2). ALL BRANCH CIRCUITS ARE PERMITTED TO BE SUPPLIED BY THE MAIN SERVICE PRIOR TO THE INSTALLATION OF ESS. THE TRADE SIZE OF THE RACEWAY SHALL NOT BE LESS THAN 1 INCH. THE SUB-PANEL THAT SUPPLIES THE BRANCH CIRCUITS MUST BE LABELED “SUBPANEL SHALL INCLUDE ALL BACKED-UP LOADS”. 2.) A MINIMUM OF FOUR BRANCH CIRCUITS SHALL BE IDENTIFIED & HAVE THEIR SOURCE OF SUPPLY COLLOCATED AT A SINGLE (SUBPANEL) PANELBOARD SUITABLE TO BE SUPPLIED BY THE ESS. AT LEAST ONE CIRCUIT SHALL SUPPLY THE REFRIGERATOR, ONE LIGHTING CIRCUIT FOR THE PRIMARY EGRESS, AND AT LEAST ONE SLEEPING ROOM RECEPTACLE CIRCUIT. 3.) THE MAIN SERVICE PANEL SHALL HAVE A MINIMUM BUSBAR RATING OF 225 AMPS. 4.) SUFFICIENT SPACE SHALL BE RESERVED TO ALLOW FUTURE INSTALLATION OF A SYSTEM ISOLATION EQUIPMENT/TRANSFER SWITCH WITHIN 3’ OF THE MAIN PANELBOARD. RACEWAYS SHALL BE INSTALLED BETWEEN THE PANELBOARD & THE SYSTEM ISOLATION EQUIPMENT/TRANSFER SWITCH LOCATION TO ALLOW THE CONNECTION OF BACK-UP POWER SOURCE. EXHAUST FANSEXHAUST FANS: : EXHAUST FANSEXHAUST FANS:: PROVIDE A MINIMUM 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR CONTINUOUS VENTILATION. CRC R303.3 FAN SHALL BE ENERGY STAR COMPLIANT & PROVIDED WITH HUMIDITY CONTROL CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF GREATER THAN 50% TO A MAXIMUM OF 80%. CGBSC 4.506.1. THE EXHAUST SHALL BE EQUIPPED WITH BACK-DRAFT DAMPERS CEnC 150.0.M.7. EXTERIOREXTERIOR: : EXTERIOR RECEPTACLESEXTERIOR RECEPTACLES: : ALL OUTDOOR RECEPTACLES SHALL BE WP/GFCI PROTECTED. CEC 210.8.3. PROVIDE AT LEAST ONE RECEPTACLE ON FRONT & BACK OF THE RESIDENCE NOT MORE THAN 6'-6" ABOVE GRADE LEVEL. CEC 210.52.E.1.2. EXTERIOR LIGHTINGEXTERIOR LIGHTING:: PROVIDE A PORCH LIGHT AT ALL EXTERIOR DOORS. ALL OUTDOOR LIGHTING TO BE HIGH EFFICACY AND CONTROLLED BY A MANUAL ON/ OFF SWITCH AND ONE OF THE FOLLOWING: A) CONTROLLED BY A PHOTOCELL & EITHER A MOTION SENSOR OR AN AUTOMATIC TIME SWITCH CONTROL, OR B) ASTRONOMICAL TIME CLOCK. CEnC 150.0.K.3.A. CHRISTMAS LIGHTS RECEPTACLESCHRISTMAS LIGHTS RECEPTACLES:: PROVIDE OUTLET NEAR TOP PLATE, SWITCHED @ FRONT DOOR - WP/GFCI PROTECTED. HVAC COND. UNIT:HVAC COND. UNIT: PROVIDE 220v ELECT. DISCONNECT W/ 30"x30" CLEAR WORKSPACE & 110v WP GFCI PROTECTED SERVICE RECEPTACLE WITHIN 25'. GARAGEGARAGE: : GARAGE LIGHTS:GARAGE LIGHTS: AT LEAST ONE LIGHT MUST BE CONTROLLED BY A VACANCY SENSOR PROVIDING AUTOMATIC-OFF FUNCTIONALITY. CEnC 150.0.K.2.C. RECEPTACLESRECEPTACLES:: PROVIDE AT LEAST ONE OUTLET IN EACH GARAGE BAY IN ATTACHED GARAGES & DETACHED GARAGES WITH ELECTRICITY & ALL SHALL BE REQUIRED TO BE GFCI PROTECTED. CEC 210.70.2.1. & CEC 210.52.G.1. RECEPTACLES:RECEPTACLES: AT LEAST (1) 120v, 20 AMP BRANCH CIRCUIT SHALL BE INSTALLED TO SUPPLY RECEPTACLE OUTLETS IN EACH GARAGE BAY & SHALL HAVE NO OTHER OUTLETS. CEC 210.11.C.4 RECEPTACLES NEAR SINKS:RECEPTACLES NEAR SINKS: ALL RECEPTACLES WITHIN 6' OF A SINK SHALL BE GFCI PROTECTED. CEC 210.8.A.7. GARAGE FIREWALLGARAGE FIREWALL:: PROVIDE A 24" SEPARATION BETWEEN RECEPTACLE & SWITCH BOXES LOCATED ON OPPOSITE SIDES OF THE FIREWALL BETWEEN THE GARAGE AND THE RESIDENCE. (BOXES IN SEPARATE STUD BAYS ARE ACCEPTABLE.) RECEPTACLE NEAR WATER HEATERRECEPTACLE NEAR WATER HEATER: SEE NOTES ON GENERAL NOTES PAGE UNDER: SEE NOTES ON GENERAL NOTES PAGE UNDER "WATER HEATERS" FOR SPECIFIC REQUIREMENTS."WATER HEATERS" FOR SPECIFIC REQUIREMENTS. EV CAPABILITY:EV CAPABILITY: A LISTED RACEWAY SHALL BE INSTALLED TO ACCOMMODATE A DEDICATED 208/240-VOLT BRANCH CIRCUIT ORIGINATING AT THE MAIN SERVICE OR SUB PANEL & SHALL TERMINATE INTO A LISTED CABINET, BOX OR OTHER ENCLOSURE FOR THE FUTURE INSTALLATION & USE OF ELECTRIC VEHICLE (EV) CHARGERS. THE RACEWAY SHALL NOT BE LESS THAN 1" INSIDE DIAMETER & SHALL BE CONTINUOUS AT ENCLOSED, INACCESSIBLE, OR CONCEALED AREAS AND SPACES. THE SERVICE PANEL AND/OR SUBPANEL SHALL PROVIDE CAPACITY TO INSTALL A 40-AMP MINIMUM BRANCH CIRCUIT. THE RACEWAY TERMINATION LOCATION SHALL BE PERMANENTLY AND VISIBLY MARKED AS “EV CAPABLE”. CGBSC 4.106.4.2.3. HALLWAYSHALLWAYS: : HALLWAYS OF 10' OR MORE IN LENGTH SHALL HAVE AT LEAST ONE ELECTRICAL RECEPTACLE. CEC 210.52 .H. KITCHEN & DINING AREASKITCHEN & DINING AREAS: : SMALL APPLIANCE CIRCUITSSMALL APPLIANCE CIRCUITS: PROVIDE TWO OR MORE 20-AMPERE SMALL APPLIANCE BRANCH CIRCUITS EVENLY PROPORTIONED IN THE KITCHEN, PANTRY, BREAKFAST ROOM, DINING ROOM OR SIMILAR AREA TO SERVE ALL WALL AND FLOOR RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS PER CEC 210.52.B.1. DISHWASHER & DISPOSALDISHWASHER & DISPOSAL TO HAVE SEPARATE DEDICATED 120 VOLT CIRCUITS WITH GFCI PROTECTION. CEC 210.8.D. KITCHEN LIGHTINGKITCHEN LIGHTING:: THE KITCHEN LIGHTING SHALL HAVE A 15 AMP MINIMUM CIRCUIT. CEC 210.23.A. ISLAND/PENINSULA COUNTERTOPS AND WORK SURFACES ISLAND/PENINSULA COUNTERTOPS AND WORK SURFACES : AT LEAST ONE RECEPTACLE SHALL BE PROVIDED FOR THE FIRST 9 SQFT, OR FRACTION THEREOF, OF THE COUNTERTOP OR WORK SURFACE. A RECEPTACLE OUTLET SHALL BE PROVIDED FOR EVERY ADDITIONAL 18 SQFT, OR FRACTION THEREOF, OF THE COUNTERTOP OR WORK SURFACE. AT LEAST ONE RECEPTACLE OUTLET SHALL BE LOCATED WITHIN 2' OF THE OUTER END OF A PENINSULAR COUNTERTOP OR WORK SURFACE CEC 210.52 (C) COUNTERTOP RECEPTACLESCOUNTERTOP RECEPTACLES: : IN THE KITCHEN, PANTRY, BREAKFAST ROOM & DINING ROOMS SHALL BE INSTALLED AT EACH WALL COUNTER SPACE THAT IS 12" OR WIDER. RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24" MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET SPACE. CEC 210.52.C.1. RECEPTACLES SHALL BE LOCATED NOT MORE THAN 20" ABOVE THE COUNTERTOP & MAY NOT BE INSTALLED FACE-UP IN ON THE COUNTER. CEC 210.52.C.5. GFCI PROTECTIONGFCI PROTECTION:: ALL KITCHEN COUNTERTOP RECEPTACLES TO BE GFCI PROTECTED. CEC 210.8.6. ELECTRIC RANGE/OVENELECTRIC RANGE/OVEN:: REQUIRES A DEDICATED 120/240 VOLT CIRCUIT. CEC 210.21.B.4. IF WITHIN 6' OF A SINK, THE RECEPTACLE SHALL BE GFCI PROTECTED RANGE HOODS FANS LESS THAN 400 CFMRANGE HOODS FANS LESS THAN 400 CFM:: SHALL BE VERIFIED BY A HERS RATER TO CONFIRM THE RANGE HOOD MEETS THE REQUIRED AIRFLOW & SOUND REQUIREMENTS SPECIFIED IN ASHRAE 62.2 SECT. 7.2. CENC 150.0(O)1G. LANDSCAPING CONTROLSLANDSCAPING CONTROLS: : LANDSCAPING IS NOT A PART OF THIS PLAN. PROVIDE STUB-OUT FOR LANDSCAPE LIGHTING & IRRIGATION TIMER. (CONFIRM LOCATION) LAUNDRY & UTILITY ROOMSLAUNDRY & UTILITY ROOMS: : BATHROOM LIGHTS:BATHROOM LIGHTS: AT LEAST ONE LIGHT MUST BE CONTROLLED BY A VACANCY SENSOR PROVIDING AUTOMATIC-OFF FUNCTIONALITY. CEnC 150.0.K.2.C. LAUNDRY & UTILITY ROOM RECEPTACLE OUTLETS:LAUNDRY & UTILITY ROOM RECEPTACLE OUTLETS: SHALL BE SUPPLIED BY AT LEAST ONE 20-AMPERE BRANCH CIRCUIT. RECEPTACLES SHALL BE GFCI PROTECTED. CEC 210.8.A.10. DRYER OUTLETDRYER OUTLET: : PROVIDE DEDICATED 30 AMP 240 VOLT RECEPTACLE FOR DRYER PER MANUFACTURER. RECEPTACLE SHALL BE GFCI PROTECTED. CEC 210.8.A LIGHTING & LIGHTING CONTROLSLIGHTING & LIGHTING CONTROLS: : LIGHTINGLIGHTING:: ALL LIGHTING MUST BE HIGH EFFICACY LIGHTS IN ACCORDANCE WITH TABLE 150.0 (A) CEnC 150.0.K. ALL LIGHTING LOCATED IN WET LOCATIONS SHALL BE MARKED "SUITABLE FOR WET LOCATIONS" & ALL LIGHTS LOCATED IN DAMP LOCATIONS SHALL BE MARKED "SUITABLE FOR DAMP LOCATIONS". CEC 410.10 .A. RECESSED LIGHTINGRECESSED LIGHTING:: SHALL NOT CONTAIN SCREW BASED SOCKETS. CEnC 150.0.K. 1C & HAVE A LABEL THAT CERTIFIES IT IS AIRTIGHT W/ LEAKAGE LESS THAN 2.0 CFM AT 75 PASCALS IN ACCORDANCE W/ ASTME283 & BE SEALED W/ A GASKET OR CAULK & MEET THE REQUIREMENTS OF CEC 410.116. RECESSED LIGHTINGRECESSED LIGHTING SHALL HAVE DIMMING CONTROLS. CEnC 150.0.K.2.F. LIGHTING CONTROL DEVICES:LIGHTING CONTROL DEVICES: ALL LIGHTING CONTROL DEVICES & SYSTEMS, BALLASTS, AND LUMINARIES MUST MEET THE REQUIREMENTS OF CEC 110.9. CEILING FANS W/LIGHT:CEILING FANS W/LIGHT: SHALL BE HIGH-EFFICACY W/ DIMMER SWITCH. MAINTAIN 36" CLEARANCE FROM ANY FIRE SPRINKLER & SMOKE DETECTORS. LAMP HOLDERS:LAMP HOLDERS: ALL SHALL BE SECURELY SUPPORTED. A FIXTURE THAT WEIGHS MORE THAN 6 POUNDS OR EXCEEDS 16 INCHES IN ANY DIMENSION SHALL NOT BE SUPPORTED BY THE SCREW SHELL OF A LAMP HOLDER PER CEC 314.23. OUTLET BOXES SHALL NOT BE USED AS THE SOLE SUPPORT FOR CEILING (PADDLE) FANS PER CEC SECTION 314.27.A&D. FIRE RESISTANCEFIRE RESISTANCE:: WHERE A LUMINAIRE IS RECESSED IN FIRE-RESISTANT MATERIAL IN A BUILDING OF FIRE-RESISTANT CONSTRUCTION, THE RECESSED LIMINAIRE SHALL SATISFY THE CONDITIONS OUTLINED IN CEC 410.116 (C). RECEPTACLESRECEPTACLES: : EVERY KITCHEN, FAMILY ROOM, DINING ROOM, LIVING ROOM, PARLOR, LIBRARY, DEN, SUNROOM, BEDROOM, RECREATION ROOM, OR SIMILAR ROOM SHALL HAVE RECEPTACLES INSTALLED IN ACCORDANCE WITH THE GENERAL PROVISIONS SPECIFIED ON CEC 210.52.A.1. THROUGH A.4.: 1.) SPACINGSPACING: : RECEPTACLES SHALL BE INSTALLED SUCH THAT NO POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6' FROM AN RECEPTACLE. 2.) WALL SPACEWALL SPACE SHALL BE CONSIDERED: A.) ANY SPACE 2' OR MORE IN WIDTH (INCLUDING SPACE MEASURED AROUND CORNERS) & UNBROKEN ALONG THE FLOOR LINE BY DOORWAYS & SIMILAR OPENINGS, FIREPLACES & FIXED CABINETS. B.) THE SPACE OCCUPIED BY FIXED PANELS IN EXTERIOR WALLS, EXCLUDING SLIDING PANELS. C.) THE SPACE AFFORDED BY FIXED ROOM DIVIDERS, SUCH AS FREESTANDING BAR-TYPE COUNTERS OR RAILINGS. 3.) FLOOR RECEPTACLESFLOOR RECEPTACLES IN OR ON FLOORS SHALL BE COUNTED AS PART OF THE REQUIRED NUMBER OF RECEPTACLES UNLESS LOCATED WITHIN 18" OF THE WALL. 4.) COUNTERTOP RECEPTACLESCOUNTERTOP RECEPTACLES INSTALLED FOR COUNTERTOP SURFACES AS SPECIFIED IN CEC 210.52(C) SHALL NOT BE CONSIDERED AS THE RECEPTACLE REQUIRED BY CEC 210.52(A). 5.) RECEPTACLES: RECEPTACLES: ALL 125 TO 250-VOLT, SINGLE PHASE, 15 AND 20-AMP NON- LOCKING TYPE RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES. SEE CEC 406.12. RECEPTACLE LOCATIONS:RECEPTACLE LOCATIONS: SHALL BE INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE THAN 6-FEET6-FEET FROM A RECEPTACLE. ANY WALL SPACE 2 FEET2 FEET OR MORE IN WIDTH AND UNBROKEN ALONG THE FLOOR LINE BY DOORWAYS AND SIMILAR OPENINGS SHALL HAVE A RECEPTACLE. CEC 210.52.A. SMOKE/CARBON MONOXIDE ALARMSSMOKE/CARBON MONOXIDE ALARMS: : SEE "NOTES, SMOKE/C.O. ALARMSNOTES, SMOKE/C.O. ALARMS" ON SEPARATE SHEET FOR ADDITIONAL INFORMATION. SMOKE ALARMSSMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: A.) IN EACH SLEEPING ROOM. CRC R314.3.1. B.) OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. CRC R314.3.2. C.) ON EACH STORY OF THE DWELLING, INCLUDING BASEMENTS & HABITABLE ATTICS & NOT INCLUDING CRAWL SPACES & UNINHABITABLE ATTICS. CRC R314.3.3 ATTICS:ATTICS: SMOKE ALARMS SHALL NOT BE INSTALLED IN UNFINISHED ATTICS OR GARAGES. CRC R314.3.3.2 COOKING APPLIANCESCOOKING APPLIANCES:: SMOKE ALARMS SHALL BE INSTALLED A MINIMUM OF 20' FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. EXCEPTIONEXCEPTION:: IONIZATION SMOKE ALARMS WITH AN ALARM SILENCING SWITCH OR PHOTOELECTRIC SMOKE ALARM CAN BE GREATER THAN 10' FROM THE APPLIANCE. PHOTOELECTRIC ALARMS CAN BE GREATER THAN 6' FROM THE APPLIANCE WHERE THE COOKING AREA & ADJACENT SPACES HAVE NO CLEAR INTERIOR PARTITIONS & THE 10' DISTANCE WOULD PROHIBIT THE PLACEMENT OF A REQUIRED SMOKE ALARM. CRC R314.3.3.4 BATHROOMSBATHROOMS:: SMOKE ALARMS SHALL BE INSTALLED MORE THAN 3' HORIZONTALLY FROM THE DOOR OR OPENING OF A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER UNLESS THIS WOULD PREVENT PLACEMENT ADJACENT BEDROOMS. CRC R314.3.3.5. F/A REGISTERF/A REGISTER:: SMOKE ALARMS SHALL NOT BE INSTALLED WITHIN 36" OF A SUPPLY REGISTER & SHALL BE LOCATED OUTSIDE OF THE DIRECT AIRFLOW OF THAT REGISTER. CRC R314.3.3.6. CEILING FANSCEILING FANS:: SMOKE ALARMS SHALL NOT BE INSTALLED WITHIN 36" OF THE TIP OF THE BLADE FROM A CEILING-SUSPENDED FAN. CRC R314.3.3.7. TRAY CEILINGSTRAY CEILINGS:: SMOKE ALARMS SHALL BE INSTALLED ON THE HIGHEST PORTION OF THE CEILING OR ON SLOPED CEILING WITHIN 12" OF THE HIGHEST POINT. CRC R314.3.3.10. INTERCONNECTIONINTERCONNECTION:: SMOKE DETECTORS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. CRC R314.4. FOR BEST RESULTS, USE DUAL IONIZATION & PHOTOELECTRIC SENSOR SMOKE ALARMS. STAIRS:STAIRS: LIGHT SWITCHLIGHT SWITCH:: A THREE-WAY LIGHT SWITCH IS REQUIRED AT THE TOP & BOTTOM OF EACH FLIGHT OF STAIRS. CEC 210.70.A & CRC R303.7. SURGE PROTECTIONSURGE PROTECTION: : CEC 230.67CEC 230.67 (A) (A) SURGE-PROTECTIVE DEVICESURGE-PROTECTIVE DEVICE: : ALL SERVICES SUPPLYING DWELLING UNITS SHALL BE PROVIDED WITH A SURGE-PROTECTIVE DEVICE (SPD). (B) (B) LOCATIONLOCATION: : THE SPD SHALL BE AN INTEGRAL PART OF THE SERVICE EQUIPMENT OR SHALL BE LOCATED IMMEDIATELY ADJACENT THERETO. EXCEPTION: THE SPD SHALL NOT BE REQUIRED TO BE LOCATED IN THE SERVICE EQUIPMENT AS REQUIRED IN (B) IF LOCATED AT EACH NEXT LEVEL DISTRIBUTION EQUIPMENT DOWNSTREAM TOWARD THE LOAD. (C) (C) TYPETYPE: : THE SPD SHALL BE A TYPE 1 OR TYPE 2 SPD. (D) (D) REPLACEMENTREPLACEMENT: : WHERE SERVICE EQUIPMENT IS REPLACED, ALL OF THE REQUIREMENTS OF THIS SECTION SHALL APPLY. TERMINAL CONNECTION TORQUETERMINAL CONNECTION TORQUE: : TIGHTENING TORQUE VALUES FOR TERMINAL CONNECTIONS SHALL BE INDICATED ON EQUIPMENT OR IN THE INSTALLATION INSTRUCTIONS. CEC 110.14. THERMOSTATS:THERMOSTATS: THERMOSTATSTHERMOSTATS: : SHALL BE PROGRAMMABLE TYPE WITH SETBACK CONTROLS. CA. ENERGY 150.0.I. SEE AGING IN PLACE FOR HEIGHT. WATER HEATERSWATER HEATERS:: GAS OR PROPANE FIREDGAS OR PROPANE FIRED: SEE NOTES ON GENERAL NOTES PAGE UNDER "WATER HEATERS". WHOLE BUILDING VENTILATIONWHOLE BUILDING VENTILATION: : WHOLE BUILDING VENTILATIONWHOLE BUILDING VENTILATION: : AN EXHAUST FANS USED AS THE QUALIFYING WHOLE-BUILDING VENTILATION FAN, SHALL COMPLY WITH THE FOLLOWING: 1.) SEE BUILDING ENERGY ANALYSIS REPORT MINIMUM REQUIREMENT RECAP FOR MINIMUM CFM RATING. 2.) BE RATED A MAXIMUM OF 1.0 SONE. 3.) THE CONTROL SWITCH MUST BE LABELED AS THE WHOLE-BUILDING VENTILATION & STATING THAT THE FAN SHOULD OPERATE WHENEVER THE HOME IS OCCUPIED. WHOLE HOUSE FANSWHOLE HOUSE FANS:: WHOLE HOUSE FANS:WHOLE HOUSE FANS: PROVIDE INSULATED LOUVERS OR COVERS (MIN. R-4.2) WHICH CLOSE WHEN THE FAN IS OFF. 3/16/2023 EXTERIOR LIGHTING:EXTERIOR LIGHTING: SEE ELECTRICAL NOTES: EXTERIOR, EXTERIOR LIGHTING. SEE ELECTRICAL NOTES:SEE ELECTRICAL NOTES: "ALL AREAS" FOR MANDATORY MEASURES. ALL LIGHTING FIXTURES:ALL LIGHTING FIXTURES: ALL LIGHTING SHALL BE L.E.D. ALL RECESSED LIGHTING:ALL RECESSED LIGHTING: THAT ARE NOT CONTROLLED BY OCCUPANCY OR VACANCY SENSORS, SHALL HAVE DIMMING CONTROLS & MUST BE AIR TIGHT & INSULATION CONTACT RATED. CEnC 150.0.K.2.F EXTERIOR RECEPTACLESEXTERIOR RECEPTACLES SEE ELECTRICAL NOTES: EXTERIOR RECEPTACLES. BREAKER PANELBREAKER PANEL SEE ELECTRICAL NOTES: BRANCH CIRCUITS. 100 AMP. © COPYRIGHT 2023 SHEET 2640 SHOWN 5/6/2024 SCALE: DATE:DARRON & KRISTIANE RANSBARGERDARRON & KRISTIANE RANSBARGER5046 SAN JUANICO DRIVE, CHICO, CALIFORNIA 95973ASSESSORS PARCEL NUMBER 047 - 440 - 075A CARPORT / COVERED PATIO for:G.S.M. CONSTRUCTIONSUMMIT STRUCTURAL DESIGN - STRUCTURAL ENGINEER383 RIO LINDO AVENUE #200, CHICO, CA 95926(530) 592-4407 WORK EMAIL ADDRESS: Ryland@SummitChico.com ARCH D (24" x 36") 1 STORY THESE PLANS HAVE BEENREVIEWED ONLY FORCOMPLIANCE WITH ATTACHEDSTRUCTURAL CALCULATIONS. THE ENGINEER'S STAMP ON THIS PLAN IS VALID ONLY WITH A LETTER SIGNED BY THISENGINEER FOR EACHUNIQUE BUILD. 5 C:/Users/Lynn/OneDrive/Documents/Chief X15 Plans/Gareth Munoz - Ransbarger Patio/RansbargerPatio.layoutOWNER: DARRON & KRISTIANE RANSBARGER(530) 966-2336 CELLEMAIL ADDRESS: Darron.Ransbarger@GMail.com MAX RAMIREZ - GOLDEN SUN DESIGN - ENERGY CALCS22189 SAMSON AVENUE, CORNING, CALIFORNIA 96021PHONE: (530) 321-7242 CELLEMAIL ADDRESS: AlphaMax47@GMail.com WHILE EVERY ATTEMPT HASBEEN MADE IN THEPREPARATION OF THIS PLANTO AVOID MISTAKES, THE MAKER CANNOT GUARANTEE AGAINST HUMAN ERROR. BUILDING CONTRACTOR / HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. LYNN SMITH - DRAFTING199 SYCAMORE VALLEY ROAD, CHICO, CA 95973(530) 891-0585 WORK EMAIL ADDRESS: LynnSmith32@ATT.net (E) LIVABLE(E) LIVABLE:: 4027 SqFt (E) TOTAL4027 SqFt (E) TOTAL (E) GARAGE(E) GARAGE:: 1293 SqFt (E) TOTAL1293 SqFt (E) TOTAL CARPORTCARPORT & COVERED& COVERED PATIOSPATIOS:: 2161 SqFt EXIST 2640 SqFt NEW 4801 SqFt TOTAL4801 SqFt TOTAL 2023GSM CONSTRUCTIONGARETH MUNOZ (530) 591-0111EMAIL ADDRESS: GarethMunoz@GMail.com ELECTRICAL PLANELECTRICAL NOTESELECTRICAL LEGEND 181.00' N90°W214.81'N0°E181.01' N89° 28' 47"E 216.45'S0°EE3' FROM GAS LINE5' FROM BLDG. OR PROP. LINED/W D/WNORTH SLOPESLOPE W ATTLESLOPE SLOPES L O PE SLOPESLOPESLOPESLOPEE LEC TE ELECT45'-4"120'-8"15'-0" 10'-0"66'-0"105'-0"38'-0"68'-0"50'-5"40'-0"20'-0"WELL LOCATION 5 0' SEPTIC FR EE A R E A 1 0 0' LE A C H F REE A R EA 10' PUBLIC SERVICES EASEMENT STREET LIGHTEDGE OF PAVEMENT C / L S A N J U A N I C O D R I V E FUTURE POOLFUTURE POOL SEPARATE PERMIT REQUIRED PROPERTY OWNERPROPERTY OWNER:: DARRON & KRISTIANE RANSBARGER 5046 SAN JUANICO DRIVE CHICO, CA 95973 PHONE (530) 966-2336 CONTRACTORCONTRACTOR:: G.S.M. CONSTRUCTION GARETH MUNOZ 1435 OAK RIDGE DRIVE CHICO, CA 95928 PHONE (530) 591-0111 SITE ADDRESSSITE ADDRESS:: 5046 SAN JUANICO DRIVE CHICO, CA 95973 CONC. WALK CONC/PAINT WASHOUT NO SOILS STOCKPILE TEMP. PORTA-POTTY LOCATION COVER BARE SOILS W/ STRAW TEMPORARY STRAW ROLLS --4027 SQFT (E) RESIDENCE --1293 SQFT (E) GARAGE --2161 SQFT (E) PORCH --2640 SQFT (N) CARPORT/COVERED PORCH 10,12110,121 SQFT TOTALSQFT TOTAL 39,029 SQFT LOT 25.9%25.9%LOT COVERAGELOT COVERAGE 5320 SQFT RESIDENCE, GARAGE (E) SEPTIC & LEACH FIELD(E) SEPTIC & LEACH FIELD: AS PER BUTTE COUNTY HEALTH DEPARTMENT REQUIREMENTS. GRADING:GRADING: THE LOT SHALL BE GRADED TO DRAIN SURFACE AWAY FROM (N) FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 INCHES WITHIN THE FIRST 10 FEET. CRC R401.3 CONC. WALK CONC. DRIVEWAY PLOT PLAN SCALE: 1" = 20'-0" (E) RESIDENCE CALGREEN NOTE:CALGREEN NOTE: DURING CONSTRUCTION, ONE OR MORE OF THE FOLLOWING MEASURES SHALL BE IMPLEMENTED TO PREVENT FLOODING OF THE ADJACENT PROPERTY, PREVENT EROSION & RETAIN SOIL RUNOFF ON THE SITE: A.) RETENTION BASINS OF SUFFICIENT SIZE SHALL BE UTILIZED TO RETAIN STORM WATER ON THE SITE. B.) WHERE STORM WATER IS CONVEYED TO A PUBLIC DRAINAGE SYSTEM, COLLECTION POINT, GUTTER OR SIMILAR DISPOSAL METHOD, WATER SHALL BE FILTERED BY USE OF A BARRIER SYSTEM, WATTLE OR OTHER METHOD APPROVED BY THE ENFORCING AGENCY. C.) COMPLIANCE WITH A LAWFULLY ENACTED STORM WATER MANAGEMENT ORDINANCE. METHODS TO MANAGE SURFACE WATER INCLUDEMETHODS TO MANAGE SURFACE WATER INCLUDE:: SWALES, WATER COLLECTION AND DISPOSAL SYSTEMS, FRENCH DRAINS, WATER RETENTION GARDENS & OTHER WATER MEASURES WHICH KEEP SURFACE WATER AWAY FROM BUILDINGS AND AID IN GROUNDWATER RECHARGE. ELECTRICAL SERVICEELECTRICAL SERVICE:: CONNECT TO UNDERGROUND ELECTRICAL SERVICE. MINIMUM EROSION & SEDIMENT CONTROLSMINIMUM EROSION & SEDIMENT CONTROLS FOR PROJECTS DISTURBING LESS THAN 1 ACRE:FOR PROJECTS DISTURBING LESS THAN 1 ACRE: THE BEST MANAGEMENT PRACTICES (BMP'S) LISTED BELOW MUST BE IN PLACE DURING CONSTRUCTION. THE BMP'S LISTED ARE MINIMUM REQUIREMENTS &B ADDITIONAL BMP'S COULD BE REQUIRED BASED ON SITE CONDITIONS. STABILIZED ENTRY: PROVIDE MINIMUM 3" TO 6" FRACTURED ROCK 50' LONG BY 15' WIDE OVER CONSTRUCTION GRADE FABRIC. ALL SOILS TRACKED ONTO PAVED ROADWAYS MUST BE CLEANED UP ON A DAILY BASIS. WHEN STREETS ARE WET OR DURING A RAIN EVENT THERE SHALL BE NO TRACKING OF SOILS ONTO THE STREET. WATTLES INSTALLED PROPERLY BEHIND CURB OR SIDEWALKS. ROCK BAGS (MINIMUM 2 PER SIDE) AT ALL DRAIN INLET LOCATIONS WITHIN 150' OF THE PROJECT SITE. INTERNAL FILTERS PLACED INSIDE EACH DRAIN INLET. TRASH BARS ACROSS THE BACK OF ALL DRAIN INLETS. STABILIZE ALL DISTURBED SOILS IN THE FRONT YARD AREAS WITHIN 15' OF THE BACK OF CURB OR SIDEWALK. (STRAW OR EROSION BLANKETS MAY BE USED FOR THIS APPLICATION) STABILIZE ALL SLOPES WHERE EROSION COULD OCCUR & CAUSE SILT RUN OFF. (STRAW, VISQUEEN OR EROSION BLANKETS MAY BE USED FOR THIS APPLICATION) ALL PAINT, FUEL, CONSTRUCTION PRODUCTS ETC. SHALL BE STORED IN A COVERED LOCATION AWAY FROM SIDEWALKS & STORM DRAIN INLETS. PORTABLE CHEMICAL TOILETS IF PROVIDED ON THE SITE MUST BE KEPT OFF OF SIDEWALKS & AT LEAST 50' FROM THE NEAREST STORM DRAIN INLET. ALL TRASH MUST COLLECTED & STORED PROPERLY. DO NOT LET ITEMS SUCH AS DRYWALL MUD BOXES, PAINT BUCKETS, CLEANING MATERIAL CONTAINERS ETC. COME IN CONTACT WITH ANY RAINFALL OR STORM WATER RUN OFF. PROVIDE A DESIGNATED AREA FOR CONCRETE WASHOUT. HAY BALES LINED WITH VISQUEEN ,AY BE USED FOR THIS APPLICATION. ROLLAWAY BINS MAY ALSO BE USED. ALL CONCRETE WASHOUT SYSTEMS SHALL BE PLACED OFF OF THE STREET. AFTER INSTALLATION OF THE ABOVE ITEMS IS COMPLETE A MAINTENANCE PROGRAM NEEDS TO BE DEVELOPED TO INSURE THE CONTINUED EFFECTIVENESS OF YOUR BMP'S. (N) CARPORT/ COVERED PORCH ABOVE-GROUNDABOVE-GROUND 325 G. PROPANE TANK325 G. PROPANE TANK: 10' MIN. FROM BLDG., HVAC COND. UNIT & PROPERTY LINE. ELECTRICAL SERVICEELECTRICAL SERVICE:: CONNECT TO UNDERGROUND ELECTRICAL SERVICE. REPLACEMENT FILEDREPLACEMENT FILED: AS PER BUTTE COUNTY HEALTH DEPARTMENT REQUIREMENTS. SUBJECT SUBJECT CHICO © COPYRIGHT 2023 SHEET 2640 SHOWN 5/6/2024 SCALE: DATE:DARRON & KRISTIANE RANSBARGERDARRON & KRISTIANE RANSBARGER5046 SAN JUANICO DRIVE, CHICO, CALIFORNIA 95973ASSESSORS PARCEL NUMBER 047 - 440 - 075A CARPORT / COVERED PATIO for:G.S.M. CONSTRUCTIONSUMMIT STRUCTURAL DESIGN - STRUCTURAL ENGINEER383 RIO LINDO AVENUE #200, CHICO, CA 95926(530) 592-4407 WORK EMAIL ADDRESS: Ryland@SummitChico.com ARCH D (24" x 36") 1 STORY THESE PLANS HAVE BEENREVIEWED ONLY FORCOMPLIANCE WITH ATTACHEDSTRUCTURAL CALCULATIONS. THE ENGINEER'S STAMP ON THIS PLAN IS VALID ONLY WITH A LETTER SIGNED BY THISENGINEER FOR EACHUNIQUE BUILD. 6 C:/Users/Lynn/OneDrive/Documents/Chief X15 Plans/Gareth Munoz - Ransbarger Patio/RansbargerPatio.layoutOWNER: DARRON & KRISTIANE RANSBARGER(530) 966-2336 CELLEMAIL ADDRESS: Darron.Ransbarger@GMail.com MAX RAMIREZ - GOLDEN SUN DESIGN - ENERGY CALCS22189 SAMSON AVENUE, CORNING, CALIFORNIA 96021PHONE: (530) 321-7242 CELLEMAIL ADDRESS: AlphaMax47@GMail.com WHILE EVERY ATTEMPT HASBEEN MADE IN THEPREPARATION OF THIS PLANTO AVOID MISTAKES, THE MAKER CANNOT GUARANTEE AGAINST HUMAN ERROR. BUILDING CONTRACTOR / HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. LYNN SMITH - DRAFTING199 SYCAMORE VALLEY ROAD, CHICO, CA 95973(530) 891-0585 WORK EMAIL ADDRESS: LynnSmith32@ATT.net (E) LIVABLE(E) LIVABLE:: 4027 SqFt (E) TOTAL4027 SqFt (E) TOTAL (E) GARAGE(E) GARAGE:: 1293 SqFt (E) TOTAL1293 SqFt (E) TOTAL CARPORTCARPORT & COVERED& COVERED PATIOSPATIOS:: 2161 SqFt EXIST 2640 SqFt NEW 4801 SqFt TOTAL4801 SqFt TOTAL 2023GSM CONSTRUCTIONGARETH MUNOZ (530) 591-0111EMAIL ADDRESS: GarethMunoz@GMail.com PLOT PLANASSESSORS MAPLOCATION MAP