Loading...
HomeMy WebLinkAbout017-300-016 SITE PLAN 6.3.24265' 7"S 12° 32 ' 52" E 224'N 12° 34' 26" E296' 4 "N 21 ° 48 ' 58 " W 178' 4"S 21° 14' 38" W36'5'18'10"5'8' (N) P o o l Equip m e n t Eagle Nest D r . 14' 4"11' 10"(E) Home(N) Pool(E) DeckSeptic TankSewer l ine to commun i ty sys tem 15' Scale: 1/8" = 1 ft EROSION CONTROL PLAN1. NO SOIL DISTURBANCESHALL OCCUR PRIOR TO OBTAINING A BUILDING PERMIT ANDGRADING PERMIT 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR EROSION CONTROL. 3. EROSION CONTROL MEASURES SHALL BE IN PLACE AT ALL TIMES. 4. SOILS TRACKED OFF SITE INTO THE STREETS SHALL BE CLEANED UP AT END OF EACHWORK DAY.5. INACTIVE SOIL STOCKPILES SHALL BE COVERED. ACTIVE STOCKPILES SHALL BE COVEREDPRIOR TO A FORECASTED RAIN EVENT.6. THE EROSION CONTRIL PLAM SHALL BE REVALUATED & ADJUSTED ACCORDINGLY AS THESITE CHANGES & AFTER RAIN EVENTS. 7. EROSION CONTROL MEASURES SHALL BE MAINTAINED. 8 PLACE SIGN AT WASHOUT. WASHING OF CONCRETE EQUIP. & TOOLS AT ANY OTHER LOCATION THAN DESIGNATED CONCRETE WASHOUT IS A VIOLATION PF LAW & SUBJECT TO FINE CALGREEN NOTES:DURING CONSTRUCTION, ONE OR MORE OF THE FOLLOWINF MEASURES SHALL BE IMPLEMENTED TO PREVENT EROSION & RETAIN SOIL RUN OFF ON SITE: A. RETENTION BASINF OF SUFFICIENT SIZE SHALL BE UTILIZED TO RETAIN STORM WATER ON THE SITE. B. WHERE STORM WATER IS CONVEYED TO A PUBLIC DRAINAGE SYSTEM, COLLECTIONPOINT, GUTTER OR SIMILAR DISPOSAL METHOD, WATER SHALL BE FILTERED BY USE OF ABARRIER SYSTEM, WATTLE OR OTHER METHOD APPROVED BY THE ENFORCING AGENCY. C. COMPLIANCE WITH LAWFULLY ENACTED STORM WATER MANAGMENT ORDINANCE METHODS TO MANAGE SURFACE WATER INCLUDE: SWALES, WATER COLLECTION AND DISPOSAL SYSTEMS, FRENCH DRAINS, WATER RETENTION GARDENS & OTHER WATER MEASURES WHICH KEEP SURFACE WATER AWAY FROM BUILDINGS AND AID IN GROUNDWATER RECHARGE. GENERAL NOTES 1. PROVIDE (2) CIRCULATION DRAINS PER PUMP THAT SHALL BE HYDRAULICALLY BALANCED, AND ARE SEPERATED BY A DISTANCE OF AT LEAST 3' IN ANY DIMENSION BETWEEN DRAINS. SUCTION OUTLETS THAT ARE LESS THAN 12" ACROSS SHALL BE COVERED WITHANTI-ENTRAPMENT GRATES. CDC SECTION 3109.4.4.8.2. POOL BARRIER SHALL COMPLY WITH CBC SECTION 3109. THE POOL SHALLINCORPORATE THE FOLLOWING: A) ACCESS GATES THROUGH THE BARRIER SHALL OPENOUTWARD AWAY FROM THE POOL AND SHALL BE SELF-CLOSING AND HAVE SELF-LATCHING DEVICE PLACED NO LOWER THAN 60" ABOVE GROUND. B) RESIDENCE DOORS PROVIDING DIRECT ACCESS TO THE POOL SHALL BEEQUIPPED WITH AN ALARM THAT PRODUCES AUDIBLE WARNING WHEN DOOR ISOPEN C) THE BARRIER SHALL BE NOT LESS THAT 60" ABOVE GROUNDMEASURED ON THE SIDE THAT FACES AWAY FROM THE POOL.3. ALL POOL EQUIPMENT MUST BE CERTIFIED BY THE ENERGY COMMISION THAT THE SYSTEM OR EQUIPMENT COMPLIES WITH CALIFORNIA ENERGY CODE SECTION 1104.4 AND 110.5 A) PROVIDE PERMANENT AND WATERPROOF OPERATING INSTRUCTIONS4. 2022 CALIF. BUILDING CODE (STRUCTURAL ONLY)5. 2022 CALIF. MECHANICAL CODE.6. 2022 CALIF. PLUMBING CODE.7. 2022 CALIF. ELECTRICAL CODE. 8. 2022 CALIFORNIA GREEN CODE (BUILDING ENERGY EFFICIENCY STANDARDS). 9. 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE. Owner:Wes McMahon Address:107 Eagle Nest Dr City:Chico Phone: State:CA Zip:95973 POOL CLEANER:IN-LINE VAC LINE:2" TILE:6' ELECTRICAL BY:BIRCHARD CHLORINATOR:YES ELECTRICAL BONDING:BIRCHARD MOTOR:VARIABLE FILTER:PENTAIR LED:YES AUTOFILL:YES ANTISUPHON:YES SKIMMERS:2 RETURNS:3 - 2" PUMP:PENTAIR HEATER:NACLOCK:YES LIGHT:PENTAIR MAIN DRAIN:2 - 2"GAS BY:NA PERIMETER:116 EST TOTAL GALLONS:16,000 DEPTH:8' SQFT:624SIZE:36'x18' POOL SPECS 265 ' 7 "S 12° 32' 5 2 " E 224' N 12° 34' 26" E 296' 4 "N 21° 4 8 ' 58 " W 178' 4" S 21° 14' 3 8 " W 36' 5'18'10"5' 8' (N) Po o lEquip m e n t Eagle Nest Dr . 14' 4" 11' 1 0 " (E) Home (N) Pool (E) Deck Septi c Tank Sew e r l ine to c ommun i t y sy s tem 15' Scale: 1/32" = 1 ft