HomeMy WebLinkAbout017-300-016 SITE PLAN 6.3.24265' 7"S 12° 32
' 52"
E
224'N 12° 34' 26"
E296' 4
"N 21
°
48
'
58
"
W
178' 4"S 21° 14' 38" W36'5'18'10"5'8'
(N) P
o
o
l
Equip
m
e
n
t
Eagle Nest D
r
.
14' 4"11' 10"(E) Home(N) Pool(E) DeckSeptic TankSewer
l
ine
to
commun
i
ty
sys
tem
15'
Scale: 1/8" = 1 ft
EROSION CONTROL PLAN1. NO SOIL DISTURBANCESHALL OCCUR PRIOR TO OBTAINING A BUILDING PERMIT ANDGRADING PERMIT
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR EROSION CONTROL.
3. EROSION CONTROL MEASURES SHALL BE IN PLACE AT ALL TIMES.
4. SOILS TRACKED OFF SITE INTO THE STREETS SHALL BE CLEANED UP AT END OF EACHWORK DAY.5. INACTIVE SOIL STOCKPILES SHALL BE COVERED. ACTIVE STOCKPILES SHALL BE COVEREDPRIOR TO A FORECASTED RAIN EVENT.6. THE EROSION CONTRIL PLAM SHALL BE REVALUATED & ADJUSTED ACCORDINGLY AS THESITE CHANGES & AFTER RAIN EVENTS.
7. EROSION CONTROL MEASURES SHALL BE MAINTAINED.
8 PLACE SIGN AT WASHOUT. WASHING OF CONCRETE EQUIP. & TOOLS AT ANY OTHER
LOCATION THAN DESIGNATED CONCRETE WASHOUT IS A VIOLATION PF LAW & SUBJECT TO
FINE
CALGREEN NOTES:DURING CONSTRUCTION, ONE OR MORE OF THE FOLLOWINF MEASURES SHALL BE
IMPLEMENTED TO PREVENT EROSION & RETAIN SOIL RUN OFF ON SITE:
A. RETENTION BASINF OF SUFFICIENT SIZE SHALL BE UTILIZED TO RETAIN STORM
WATER ON THE SITE. B. WHERE STORM WATER IS CONVEYED TO A PUBLIC DRAINAGE SYSTEM, COLLECTIONPOINT, GUTTER OR SIMILAR DISPOSAL METHOD, WATER SHALL BE FILTERED BY USE OF ABARRIER SYSTEM, WATTLE OR OTHER METHOD APPROVED BY THE ENFORCING AGENCY. C. COMPLIANCE WITH LAWFULLY ENACTED STORM WATER MANAGMENT ORDINANCE
METHODS TO MANAGE SURFACE WATER INCLUDE:
SWALES, WATER COLLECTION AND DISPOSAL SYSTEMS, FRENCH DRAINS, WATER
RETENTION GARDENS & OTHER WATER MEASURES WHICH KEEP SURFACE WATER AWAY
FROM BUILDINGS AND AID IN GROUNDWATER RECHARGE.
GENERAL NOTES
1. PROVIDE (2) CIRCULATION DRAINS PER PUMP THAT SHALL BE
HYDRAULICALLY BALANCED, AND ARE SEPERATED BY A DISTANCE OF
AT LEAST 3' IN ANY DIMENSION BETWEEN DRAINS. SUCTION
OUTLETS THAT ARE LESS THAN 12" ACROSS SHALL BE COVERED WITHANTI-ENTRAPMENT GRATES. CDC SECTION 3109.4.4.8.2. POOL BARRIER SHALL COMPLY WITH CBC SECTION 3109. THE POOL SHALLINCORPORATE THE FOLLOWING: A) ACCESS GATES THROUGH THE BARRIER SHALL OPENOUTWARD AWAY FROM THE POOL AND SHALL BE
SELF-CLOSING AND HAVE SELF-LATCHING DEVICE PLACED NO LOWER THAN 60"
ABOVE GROUND.
B) RESIDENCE DOORS PROVIDING DIRECT ACCESS TO THE POOL SHALL BEEQUIPPED WITH AN ALARM THAT PRODUCES AUDIBLE WARNING WHEN DOOR ISOPEN C) THE BARRIER SHALL BE NOT LESS THAT 60" ABOVE GROUNDMEASURED ON THE SIDE THAT FACES AWAY FROM THE POOL.3. ALL POOL EQUIPMENT MUST BE CERTIFIED BY THE ENERGY COMMISION
THAT THE SYSTEM OR EQUIPMENT COMPLIES WITH CALIFORNIA ENERGY CODE
SECTION 1104.4 AND 110.5
A) PROVIDE PERMANENT AND WATERPROOF OPERATING
INSTRUCTIONS4. 2022 CALIF. BUILDING CODE (STRUCTURAL ONLY)5. 2022 CALIF. MECHANICAL CODE.6. 2022 CALIF. PLUMBING CODE.7. 2022 CALIF. ELECTRICAL CODE.
8. 2022 CALIFORNIA GREEN CODE (BUILDING ENERGY EFFICIENCY
STANDARDS).
9. 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE.
Owner:Wes McMahon
Address:107 Eagle Nest Dr
City:Chico
Phone:
State:CA
Zip:95973
POOL CLEANER:IN-LINE
VAC LINE:2"
TILE:6'
ELECTRICAL BY:BIRCHARD
CHLORINATOR:YES
ELECTRICAL BONDING:BIRCHARD
MOTOR:VARIABLE
FILTER:PENTAIR
LED:YES
AUTOFILL:YES
ANTISUPHON:YES
SKIMMERS:2
RETURNS:3 - 2"
PUMP:PENTAIR
HEATER:NACLOCK:YES
LIGHT:PENTAIR
MAIN DRAIN:2 - 2"GAS BY:NA
PERIMETER:116
EST TOTAL GALLONS:16,000
DEPTH:8'
SQFT:624SIZE:36'x18'
POOL SPECS
265
'
7
"S 12° 32' 5
2
"
E
224'
N 12° 34' 26" E 296' 4
"N 21°
4
8
'
58
"
W
178' 4"
S 21° 14' 3
8
"
W
36'
5'18'10"5'
8'
(N) Po
o
lEquip
m
e
n
t
Eagle Nest Dr
.
14' 4"
11'
1
0
"
(E) Home
(N) Pool
(E) Deck
Septi
c
Tank
Sew
e
r
l
ine
to
c
ommun
i
t
y
sy
s
tem
15'