Loading...
HomeMy WebLinkAboutFAI15-0050 041-130-044 Butte College Paint Booth Welding 6.24.24 Dry Chemical Pre-Engineered California Code of Regulations -Title 19 Semi-Annual 2 of 2 Fire Extinguishing System Inspection,Testing,and Maintenance Report OF C fit4Nt Property Information :�� 'gyp of Contractor or Licensed Owner Information 'Building Name Butte College Welding lz'r Name Voltage Specialists 'Address 3536 Butte Campus Dr ��, Job# City Oroville ;ti,4 E wiRt- Inspection, Testing, and Maintenance = Inspection T =Test M=Maintenance P=Pass F=Fail N/A =Not Applicable Item Description NFPA 17 CA ed. Date Comments Only P,F,N/A Reference 3.8 M Dry Chemical is Not Caked 11.3.1.1(4) N/A (Non-Pressurized) 3.9 I M INo Signs of Corrosion or Damage to the Agent Cylinders I 11.3.1.3 I I I P 3.10 I M Fixed-Temperature Sensing Elements Maintained or I11.3.2 P Replaced 3.11 I M 'Dry Chemical is Not Caked I 11.3.1.2 I P (Stored Pressure Tank Every 6 Years) D=Deficiency C=Comment (Indicate type) Item Date Rise Deficiencies and Comments Item Date RisM Indicate all equipment,devices and parts that were repaired or replaced Lill i LiiLi LiILi LiiLi Lieu LiILi Lieu fI I ❑Check here if additional Deficiencies and Comments are listed on Form AES 9. Number attached: ❑ See Correction Form AES 10 for corrected deficiencies. Number attached: 1 hereby certify that the fire protection equipment listed above has been fully inspected, tested,and maintained on this date by the company indicated above, in accordance with CCR, Title 19, Sections 901 to 906 and that the equipment is fully operable except as noted in the "Deficiencies and Comments"section of this form. Print Name I Don Cantrell Signature I Date 06/28/24 Form AES 21 Sept.3,2013 Specialty Pre-Engineered &Engineered Fire California Code of Regulations -Title 19 Semi-Annual 1 of 1 Extinguishing System Inspection,Testing,and Maintenance Report _ _ Property Information %��.�F �p�� Contractor or Licensed Owner Information (Building Name Butte College Welding ; { la' (Name Voltage Specialists (Address 3536 Butte Campus Dr t�}j �J (Address 370 Apple Lane (City Paradise St. CA Zip 9699 (City Oroville (License# 880860 (Phone 530-624-4514 (Contact Person Mark Allen I ❑ SFM (Job# (Phone I ❑� CSLB 'Misc. S stem Information System Location Outside paint booth System Mfr. Pyrochem Model# MCH 3 (Protected Area Type Paint booth Protected Hazard Powder coating boos Cylinder Size(s) 70#x2 D=Deficiency C=Comment (Indicate type) DateIMIIMir Deficiencies and Comments Indicate all equipment,devices and parts that were repaired or replace- n Eil II 111 1-11171 I III I I II I L il III I❑ ❑Check here if additional Deficiencies and Comments are listed on Form AES 9. Number attached: ❑ See Correction Form AES 10 for corrected deficiencies. Number attached: 1 hereby certify that the fire protection equipment listed above has been fully inspected, tested,and maintained on this date by the company indicated above,in accordance with CCR, Title 19, Sections 901 to 906 and that the equipment is fully operable except as noted in the "Deficiencies and Comments"section of this form. Print Name I Don Cantrell Signature I Date 06/28/24 Form AES 22 Sept.3,2013