Loading...
HomeMy WebLinkAboutFAI15-0050 041-130-044 Butte College #9 Math Building FM200 6.28.24 Report of Inspection/Test Annual Special Hazard FM200 System YOL,AGAPEcIALISTs Date: 6/28/24 Property Owner/Agent Butte college Butte college C10/16 License#880862 530-624-4514 Math Building Conducted by: Don Cantrell Inspection Ref: 1-161 Signatures Inspector-Printed Don Inspector-Signature Date I state that the information on this form is correct at the /� time and place of w eftinspection,and that all equipment on Cantell ��(''j]//I� 6/28/24 tested at this time was left in operational condition upon completion of this inspection except as noted. Owner- Printed Owner-Signature Date Except as noted,the building is occupied with the same occupancy classification and hazard of contents as last inspection. Also,the system has remained in service without modification and been free of actuation of devices or alarms. Notifications To Be Notified I Testing I Time I Phone I Contact NA ,Start I End 1 I I /►� System and Panel Information TypeVSH 1230 1315 LBS Amount of Agent I Hazard Computer room Panel Manufacturer IModel I Serial No. ILocation Firelite MRP-2002 00014209 5221 Server room Over current Protection Type Over current Size(Amps) Primary Supply Disconnect Location/Panel#/Breaker# Breaker I 20 !Same room next to simplex FACP Cylinder(s) Cylinder Fill I Inspection-Service Equip ID Description! Size Manufacturer Weightal > d `o L 0. Location Model „ o. 3 o g - Y a 3 r, 43 0 U C d .v -- 2 'v 00 3 o R 0, 3 5 u- v` c l°_ C7 a U _ I.- ~ < is 0 I U m t— N Server room Viking 1, 22 258lH36OI00okIokloklokIokIokIokINa Ok-Passes Inspection S-Serviced on site X-Requires Service NA-Not Applicable Page 1 of 3 Voltage Specialists, 370 Apple Lane,Paradise 96969 Report of Inspection/Test Annual Special Hazard FM200 System VOLTAG PECIALISTS Date: 6/28/24 Property: Butte college c10/16 License#880862 530-624-4514 Owner: Butte college Inspection Ref: 1-161 System Function Summary & Test Function Description Yes No I Alarm Panel Supervisory Functions Panel AC Power Loss I Loss of AC power to the alarm panel is detected by the alarm system. I O 0 Panel Sec Power Loss I Loss of Secondary power to the alarm panel is detected by the alarm O ❑ system. Open Alarm Circuits I Electrical opens in initiating and indicating circuits are detected. I ❑✓ ❑ Short Alarm Circuits I Electrical shorts in initiating and indicating circuits are detected. I I✓I ❑ Panel to Panel Circuits Integrity of single or multiple circuits providing interface between two or I a ❑ more control panels verified. Ground Faults Detected I Ground faults in alarm and power circuits are detected • I ✓❑ ❑ Alarm Functions - Chemical Suppression 1st Alarm A single initiating zone shows alarm. ❑✓ ❑ 2nd Alarm A 2nd initiating zone shows alarm. n n Time Delay Delay between 1st alarm and agent discharge. ❑ I Discharge Alarm Audible alarm upon agent discharge. ❑ Agent discharge Actual discharge of chemical fire suppression agent. �✓ ❑ Abort Switch Switch prevents discharge of chemical fire suppression agent. n n Panel Inspection Yes ❑✓ No ❑ System was in operation upon arrival? Yes ❑✓ No ❑ Panel and surrounding equipment, conduit and wiring well secured and in good condition Yes ElNo ❑ Are all lamps and displays operating correctly? Yes ❑✓ No ❑ Primary power supply operates properly under full load ? Yes ❑✓ No ❑ Are drawings and wiring diagrams available at the panel? Yes ❑✓ No ❑ Are operating instructions posted or available at the panel? Yes n No ❑ Are zones labeled and identified? Chemical Suppression Inspection Yes ElNo El Agent control heads or nozzles are in good condition and properly mounted ? Yes ❑✓ No ❑ All ceiling and floor panels are in place? Yes ❑✓ No ❑ Warning signs are proper and visible ? Central Station Test Yes ❑ No ✓❑ Type Transmission Yes ❑ No El Alarm, Trouble and Supervisory indication tested and verified with the central station? Yes ❑ No ❑ Operator spoke to Page 2 of 3 Voltage Specialists, 370 Apple Lane,Paradise 96969 Report of Inspection/Test Annual Special Hazard FM200 System VOLTAG PECIALISTS Date:6/28/24 c10/16 License#880862 530-624-4514 Property: Butte college Owner: Butte college Inspection Ref: 1-161 Alarm Device List Zone Physical Functional Device Type Address Location Description Manufacture Model Condition Test Photo smoke detector 1-1 Ceiling I Fike Good Passed Photo smoke detector 1-2 Ceiling I Fike Good Passed Photo smoke detector 2-1 Ceiling I Fike Good Passed Photo smoke detector 2-2 Ceiling IFike Good Passed Horn strobe N1-1 Inside by door !Wheelock Good Passes Strobe N1-2 Outside by door Wheelcok Good Passed Manual 3-1 By door exit Fike Good Passed Abort 4 By door exit Fike Good Passed 8ah batteries Panel 02/02/2021 Good Passed Tank measure at 19.25 Tank supervisory 6-1 Tank Control head Viking Good Passed Alarm Device Summary Number 1 0 IS (teems Serviced 11 C m of Items IX 'Items Requiring Service I I 1 Voltage Specialists, 370 Apple Lane,Paradise 96969 Page 3 of 3