Loading...
HomeMy WebLinkAboutFAI15-0050 041-130-044 Butte College #8 Allied Health South FM200 6.28.24 Report of Inspection/Test Annual Special Hazard FM200 System YOLTAGPECIALISTs Date: 6/28/24 Property Owner/Agent Butte College Butte College C10/16 License#880862 530-624-4514 Allied Health South Conducted by: Don Cantrell Inspection Ref: 11-168 Signatures Inspector-Printed Don Inspector-Signature Date I state that the information on this form is correct at the /�� w time and place of inspection,and that all equipment Cantrell ��('j]//I 6/28/24 tested at this time was left in operational condition upon completion of this inspection except as noted. Owner-Printed Mark Allen Owner-Signature Date Except as noted,the building is occupied with the same occupancy classification and hazard of contents as last inspection. Also,the system has remained in service without modification and been free of actuation of devices or alarms. Notifications To Be Notified I Testing I Time I Phone I Contact NA ,Start /►� End 1 System and Panel Information Type Fm 200 I425 LBS Amount of Agent I HazardComputer room Panel Manufacturer I Moc Serial No. 1 Locaticr Chemtron Micro 1002 Server room Over current Protection Type Over current Size(Amps) Primary Supply Disconnect Location/Panel#/Breaker# Breaker I 20 I PANEL SLB Cylinder(s) Cylinder Fill I Inspection-Service Equip ID Description! Size Manufacturer Weight > d `o L 0. Location Model „ o. 3 'o g = Y o, 3 r, 43 0 � & .o " o 'v V 3 o R 0) 3 5 u- 15 c l°_ C7 c U 0 _ ~ ~ < (' J = U m t— N Server room Chemtrom [ , t . 1, 2 '13701OklOkl OklOkl Okl OklOkl OklOklOk Ok-Passes Inspection S-Serviced on site X-Requires Service NA-Not Applicable Page 1 of 3 Voltage Specialists 370 Apple Lane, Paradise 95969 Report of Inspection/Test Annual Special Hazard FM200 System VOLTAG PECIALISTS Date: 6/28/24 Property: Butte College c10/16 License#880862 530-624-4514 Owner: Butte College Inspection Ref: I1-168 System Function Summary & Test Function Description Yes No I Alarm Panel Supervisory Functions Panel AC Power Loss I Loss of AC power to the alarm panel is detected by the alarm system. I O 0 Panel Sec Power Loss I Loss of Secondary power to the alarm panel is detected by the alarm O ❑ system. Open Alarm Circuits I Electrical opens in initiating and indicating circuits are detected. I ❑✓ ❑ Short Alarm Circuits I Electrical shorts in initiating and indicating circuits are detected. I I✓I ❑ Panel to Panel Circuits Integrity of single or multiple circuits providing interface between two or I a ❑ more control panels verified. Ground Faults Detected I Ground faults in alarm and power circuits are detected • I ✓❑ ❑ Alarm Functions - Chemical Suppression 1st Alarm A single initiating zone shows alarm. ❑✓ ❑ 2nd Alarm A 2nd initiating zone shows alarm. n n Time Delay Delay between 1st alarm and agent discharge. L✓J ❑ I Discharge Alarm Audible alarm upon agent discharge. �� ❑ Agent discharge Actual discharge of chemical fire suppression agent. �✓ ❑ Abort Switch Switch prevents discharge of chemical fire suppression agent. n n Panel Inspection Yes ❑✓ No ❑ System was in operation upon arrival? Yes ❑✓ No ❑ Panel and surrounding equipment, conduit and wiring well secured and in good condition Yes ElNo ❑ Are all lamps and displays operating correctly? Yes ❑✓ No ❑ Primary power supply operates properly under full load ? Yes ❑✓ No ❑ Are drawings and wiring diagrams available at the panel? Yes ❑✓ No ❑ Are operating instructions posted or available at the panel? Yes n No ❑ Are zones labeled and identified? Chemical Suppression Inspection Yes ElNo El Agent control heads or nozzles are in good condition and properly mounted ? Yes ❑✓ No ❑ All ceiling and floor panels are in place? Yes ❑✓ No ❑ Warning signs are proper and visible ? Central Station Test Yes ❑ No ✓❑ Type Transmission Yes ❑ No El Alarm, Trouble and Supervisory indication tested and verified with the central station? Yes ❑ No ❑ Operator spoke to Page 2 of 3 Voltage Specialists 370 Apple Lane, Paradise 95969 Report of Inspection/Test Annual Special Hazard FM200 System VOLTAG PECIALISTS Date:6/28/24 c10/16 License#880862 530-624-4514 Property: Butte College Owner: Butte College Inspection Ref: 11-168 Alarm Device List Zone Physical Functional Device Type Address Location Description Manufacture Model Condition Test Photo smoke 1 Ceiling I Hochiki Good I Passed Ion smoke 1 Ceiling IHochiki Good IPassed Ion smoke 2 Ceiling IHochiki Good IPassed Ion smoke 1 Ceiling IHochiki GoodPassed Smoke Under floor I No access I Smoke Ion 1 Under floor Good I Passed Smoke Under floor No access I Smoke Under floor I No access I Pull station Man rise. West exit Notifier Good !Passed Pull station Man rise. East exit Notifier Good Passed Abort Abort West exit Chemtron Good Passed Abort Abort East exit Chemtron Good Passed Horn strobe N1 Above FACP System sensor Good Passed Strobe N1 Hall System senso Good Passed Bell N1 Above FACP System sensor Good Passed 8 ah batteries Panel 2023 Good Passed Alarm Device Summary Number 1 6 IS Items Serviced 11 E I 1 E of Items IX 'Items Requiring Service 11 E I 1 E Page 3 of 3 Voltage Specialists 370 Apple Lane, Paradise 95969