HomeMy WebLinkAboutFAI20-0005 009-162-014 HAZEL HOTEL_ Fire Alarm-SILENT KNIGHT 5820XL_ 3-8-2024 (Annual) Form for Inspection, Testing and Maintenance of �11, 4* Security Systems Fire Alarms and Signaling Systems A VYANET OPERATING GROUP, INC.COMPANY Location Code: 045-344-2122 Contact: TRISH STILWELL Company: Eagle Security Systems Contact Address: 880 HAZEL ST Address: 3268 Esplanade Ste A GRIDLEY,CA 95948 Chico,CA 95973 Phone: 530-846-7800 Company Phone: 530-345-6395 Email: HAZEL@CHIPHOUSING.ORG Inspector Carlos Palomera Property Evaluated: HAZEL HOTEL(Business) 156551 NICET II 880 HAZEL ST Date of Work: 3/8/2024 GRIDLEY,CA 95948 Frequency: Annual Description: Fire Alarm(SILENT KNIGHT 5820XL) Deficiency Summary Please refer to the Deficiency Summary located on applicable Fire Alarm Supplementary Forms for additional deficiency details. General Comments There are no general comments for this submission Eagle Security Systems,3268 Esplanade Ste A,Chico,CA,95973 Phone:530-345-6395 Page 1 of 4 Eagle Security Systems S AG L E 3268 Esplanade Ste A Security Systems Chico,CA 95973 A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395 Form for Inspection, Testing and Maintenance of Fire Alarms and Signaling Systems Separate forms are available for inspection,testing,and maintenance 4.System Information of the rest of the fire protection system of which the fire alarms and 4.1 Control Unit: signaling systems are a part.More frequent inspection,testing,and Manufacturer: Silent knight maintenance may be necessary depending on the conditions of the occupancy and the water supply. Model number: 5820x1 Notes: 4.2 Software and Firmware Revision number: 9.09 1. All questions are to be answered Yes,No,or Not Applicable.All 4.3 System Power: "No"answers are to be explained in the Comments for this form. 4.3.1 Primary(Main)Power: 2. Refer to NFPA-72 for specific inspection frequency requirements Nominal voltage: 120 for the different components. 1.Property Information Amps: 20 Owner: Location: Elevator Lobby TRISH STILWELL Overcurrent protection type: Breaker Owner's Phone Number: Amps: 20 530-846-7800 Disconnecting means location: #11 Owner's Address: 4.3.2 Secondary Power: 880 HAZEL ST.GRIDLEY.CA.95948 Type: Battery Property Being Evaluated: Location: Panel HAZEL HOTEL(Business) Battery type(if applicable): ❑Lead-acid❑Nickel- cadmiumPro e Address: Property ❑Primary(dry cell) 880 HAZEL ST.GRIDLEY.CA.95948 ❑✓Sealed lead-acid Assembly Description: Calculated capacity of batteries to drive the system: Fire Alarm(SILENT KNIGHT 5820XL) In standby mode(hours): 2.Owner's Section In alarm mode(minutes): A.Are the fire alarms and signaling systems ]Yes❑No 5.Notifications Made Prior To Testing in service? B.Have fire alarms and signaling systems ❑✓Yes❑No Contact remained in service since the last inspection? C.Was the system(of which the fire alarm Monitoring VYANET 09:00 and signaling systems are a part)free of organization: actuation of devices or alarms since the last ]Yes❑No Building STAFF 09:00 inspection? management: D.The required record documents are available and include the current revisions of I Building occupants: NA NA all fire alarm software and the revisions of Yes❑No Authority Having software of any systems with which the fire Jurisdiction: NA NA alarm software interfaces? 3.Monitoring Information Other,if required: Monitoring organization: Vyanet Operating Group Address: 2700 Hegan Lane Suite 112 Chico CA.95926 Phone: 541-241-1800 Fax: Email: Account number: 344-2122 Phone line 1: Phone line 2: Means of transmission: CELL Entity to which alarms are retransmitted: Phone: NFPA 72 v1.1-2019 Page 2 of 4 Eagle Security Systems ta) =' E AG IdE 3268 Esplanade Ste A 'r-' Security Systems Chico,CA 95973 A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395 6.Testing Results 6.6 Supervising Station Monitoring 6.1 Control Unit and Related Equipment Lscription I Yes/No I i ascription Visual Functional Results Alarm signal ,/Yes❑No U Pass❑Fail Inspection Test ❑N/A Alarm L✓J Pass❑Fail Control unit ❑d Yes❑No ❑d Yes❑No 0 Pass❑Fail restoration 0 Yes❑No ❑N/A N/A Lamps/LEDs/L L✓J Pass❑Fail Trouble signal ❑✓yes❑No L✓J Pass❑Fail CDs 0Yes❑No 0Yes El No ]N/A ❑N/A Trouble L✓J Pass❑Fail Fuses 0 Yes❑No ❑�Yes❑No L✓J Pass❑Fail restoration L✓J Yes_J No ❑N/A N/A Trouble signals L✓J Pass❑Fail Supervisory L✓J Yes_J No L✓J Pass❑Fail L✓J Yes_J No L_l Yes❑No ] Li signal ❑N/A Disconnect L✓J Pass❑Fail/A Supervisory L✓J Yes_J No ❑✓Pass CI Fail switches L✓J Yes_J No L_l Yes❑No ]N/A restoration ❑N/A 6.7 Public Emergency Alarm Reporting System Ground-fault ❑✓Pass❑Fail L✓J Yes_J No L_l Yes❑No monitoring ]N/A Description [ Yes/No I I Time(seconds) Results Supervision 0 Pass❑Fail Alarm signal ❑Pass CI Fail LJ Yes_JNo L�Yes❑No ]N/A ❑Yes❑No _✓I N/A Local ❑✓Pass❑Fail Alarm CI Pass CI Fail annunciator L✓J Yes_JNo L�Yes❑No _J N/A El Yes❑No restoration _✓I N/A Remote ❑✓Pass CI Fail Trouble signal CI Pass CI Fail annunciators ❑✓Yes❑No ❑/Yes❑No _J N/A ❑Yes❑No ❑✓N/A Remote power ❑✓Pass CI Fail Trouble ❑Pass❑Fail ❑✓Yes❑No ❑/Yes❑No ❑Yes❑No panels _J N/A restoration 0 N/A CI Pass CI Fail Supervisory ❑Pass❑Fail Other: ❑Yes❑No ❑Yes El No _J N/A signal ry ❑Yes❑No NA N/A g 6.2 Secondary Power Supervisory ]Yes❑No ❑Pass❑Fail Description Visual Functional Results restoration ❑✓N/A Inspection Test 1 7.Notifications That Testing Is Complete Battery 0 Pass❑Fail Contact ime 11-7 condition ❑✓Yes❑No ❑O Yes❑No ]N/A Monitoring VYANET 12:50 Load voltage ❑✓Yes❑No ❑/Yes❑No ❑✓Pass❑Fail organization: _J N/A Building STAFF 12:50 Discharge test ❑✓Yes❑No ❑/Yes❑No ❑✓Pass❑Fail management: _J N/A Charger test ❑✓Pass CI Fail Building occupants: NA NA ❑✓Yes❑No ❑/Yes El No ]N/A Authority Having Jurisdiction: NA NA Remote panel ❑�/Yes❑No ❑�Yes❑No IA Pass❑Fail batteries ❑N/A Other,if required: 6.3 Alarm and Supervisory Alarm Initiating Device 8.System Restored To Normal Operation Complete supplementary device test form for all initiating devices. Date: 3/8/2024 6.4 Notification Appliances Time: 12:50 Complete supplementary appliance test form for all notification 9.Comments appliances. Any "No"answers, test failures or other problems found with the fire 6.5 Interface Equipment alarm system must be explained using the comment specific for each Complete supplementary interface component test form for all question.Additional comments can be added here. interface components. Please see the summary section at the top of the form for the Circuit Interface/Signaling Line Circuit Interface/Fire Alarm comments. Control Interface 10.Inspector's Information Inspected By Carlos Palomera Inspector License: 156551 NICET II I state that the information on this form is correct at the time and place of my inspection,and that all equipment tested at this time was left in operating condition upon completion of this inspection except as noted in the Comments.This system as specified herein has been inspected and tested according to NFPA 72,2016 edition,Chapter 14. NFPA 72 v1.1-2019 Page 3 of 4 1�����"'� Eagle3268Esplana Securityd Systems ��� =� EAGLE e SteA ' 0Security Systems Chico,CA 95973 A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395 Signature of Inspector T Date 3/8/2024 11.Owner or Owner's Representative Owner or Owner's Representative Name Owner or Owner's Representative Signature Na Signature Available Date 3/8/2024 NFPA 72 v1.1-2019 Page 4 of 4