Loading...
HomeMy WebLinkAboutB24-1262 040-310-087 OAK RIDGE CABINETS, Fire Alarm-ADEMCO 128FB, 4-27-2023 (Annual) Form for Inspection, Testing and Maintenance of �1, * Security Systems Fire Alarms and Signaling Systems A VYANET OPERATING GROUP, INC.COMPANY Location Code: 045-715-5390 Contact: SHAWN MACNEILL Company: Eagle Security Systems Contact Address: 11128 MIDWAY Address: 3268 Esplanade Ste A CHICO,CA 95928-8240 Chico,CA 95973 Phone: 530-893-8774 Company Phone: 530-345-6395 Email: SHAWN@OAKRIDGECABINETS.COM Inspector Carlos Palomera Property Evaluated: OAK RIDGE CABINETS(Business) 156551 NICET II 11128 MIDWAY-A Date of Work: 4/27/2023 CHICO,CA 95928-8240 Frequency: Annual Description: Fire Alarm(ADEMCO 128FB) Deficiency Summary Please refer to the Deficiency Summary located on applicable Fire Alarm Supplementary Forms for additional deficiency details. General Comments There are no general comments for this submission VYANET Operating Group,Inc.,410 SW Columbia,Suite 120,Bend,OR,97702 Phone:541-812-6409 Page 1 of 4 Eagle Security Systems E AGLE 3268 Esplanade Ste A Security Systems Chico,CA 95973 A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395 Form for Inspection, Testing and Maintenance of Fire Alarms and Signaling Systems Separate forms are available for inspection,testing,and maintenance 4.System Information of the rest of the fire protection system of which the fire alarms and 4.1 Control Unit: signaling systems are a part.More frequent inspection,testing,and Manufacturer: Honeywell maintenance may be necessary depending on the conditions of the occupancy and the water supply. Model number: Vista 128FB Notes: 4.2 Software and Firmware Revision number: N/a 1. All questions are to be answered Yes,No,or Not Applicable.All 4.3 System Power: "No"answers are to be explained in the Comments for this form. 4.3.1 Primary(Main)Power: 2. Refer to NFPA-72 for specific inspection frequency requirements Nominal voltage: 120 for the different components. NFPA 72 Edition: ❑2013 Z 2016❑2019 Amps: 20 The work covered on this form is(select Location: N/a one): Annual Overcurrent protection type: Breaker Date of Work 4/27/2023 Amps: 20 All responses refer to the current work(inspection, testing and Disconnecting means location: N/a maintenance)performed on this date. 4.3.2 Secondary Power: 1.Property Information Type: Battery Owner: Location: Panel SHAWN MACNEILL Battery type(if applicable): ❑Lead-acid❑Nickel- Owner's Phone Number: cadmium 530-893-8774 ❑Primary(dry cell) ❑✓Sealed lead-acid Owner's Address: Calculated capacity of batteries to drive the system: 11128 MIDWAY.CHICO.CA.95928-8240 Property Being Evaluated: In standby mode(hours): In alarm mode(minutes): OAK RIDGE CABINETS(Business) 5.Notifications Made Prior To Testing Property Address: 11128 MIDWAY-A.CHICO.CA.95928-8240 Contact Assembly Description: Fire Alarm(ADEMCO 128FB) Monitoring VYANET 08:45 2.Owner's Section organization: A.Are the fire alarms and signaling systems ❑✓Yes❑No Building STAFF 08:45 in service? management: B.Have fire alarms and signaling systems ✓J Yes❑No Building occupants: NA NA remained in service since the last inspection? C.Was the system(of which the fire alarm Authority Having CAL FIRE 08:45 and signaling systems are a part)free of A Yes❑No Jurisdiction: actuation of devices or alarms since the last Other,if required: inspection? D.The required record documents are available and include the current revisions of all fire alarm software and the revisions of _✓J Yes❑No software of any systems with which the fire alarm software interfaces? 3.Monitoring Information Monitoring organization: VYANET Address: Phone: 530-345-6395 Fax: Email: Account number: 174-5390 Phone line 1: Phone line 2: Means of transmission: CELL Entity to which alarms are retransmitted: Phone: NFPA 72 v1.1-2019 Page 2 of 4 01�����"'� Eagle3268 Securityld Systems ��� =� E A L E Espanae Ste A 'r-' Security Systems Chico,CA 95973 A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395 6.Testing Results 6.6 Supervising Station Monitoring 6.1 Control Unit and Related Equipment Lscription I Yes/No I i ascription Visual Functional Results Alarm signal ,/Yes❑No U Pass❑Fail Inspection Test ❑N/A Alarm L✓J Pass❑Fail Control unit ❑d yes❑No ❑d Yes❑No 0 Pass❑Fail restoration 0 Yes❑No ❑N/A N/A Lamps/LEDs/L LJ Pass❑Fail Trouble signal 0 Yes❑No LJ Pass❑Fail CDs 0Yes❑No 0Yes El No ]N/A ❑N/A Trouble LJ Pass❑Fail Fuses 0 Yes❑No 0 Yes❑No LJ Pass❑Fail restoration LJ Yes_J No ❑N/A N/A Trouble signals LJ s❑PasFail Supervisory LJ Yes_J No LJ Pass❑Fail LJ Yes_J No kJ Yes❑No ] Li signal ❑N/A Disconnect LJ Pass❑Fail Supervisory LJ Yes_J No ❑✓Pass III Fail switches LJ Yes_J No kJ Yes❑No ]N/A restoration ❑N/A 6.7 Public Emergency Alarm Reporting System Ground-fault ❑✓Pass❑Fail LJ Yes_J No kJ Yes❑No monitoring ]N/A Description [ Yes/No I I Time(seconds) Results Supervision 0 Pass❑Fail Alarm signal III Pass❑Fail LJ Yes_JNo LJ Yes❑No ]N/A ❑Yes❑No _✓I N/A Local ❑✓Pass❑Fail Alarm III Pass❑Fail annunciator LJ Yes_JNo LJ Yes❑No _J N/A CI Yes❑No restoration _✓I N/A Remote ❑✓Pass❑Fail Trouble signal III Pass❑Fail annunciators ❑✓Yes❑No ❑/Yes❑No _J N/A ❑Yes❑No ❑✓N/A Remote power ❑✓Pass❑Fail Trouble ❑Pass❑Fail ❑✓Yes❑No ❑/Yes❑No ❑Yes❑No panels _J N/A restoration 0 N/A III Pass III Fail Supervisory ❑Pass❑Fail Other: CI Yes❑No ❑Yes El No _J N/A signal ry ❑Yes❑No NA N/A g 6.2 Secondary Power Supervisory ]Yes❑No ❑Pass❑Fail Description Visual Functional Results restoration ❑✓N/A Inspection Test 1 7.Notifications That Testing Is Complete Battery J Pass❑Fail Contact ime condition 0 Yes❑No ❑O Yes❑No ]N/A Load volts e ❑✓Pass❑Fail organization: Monitoring VYANET 11:00 g ❑✓Yes❑No ❑/Yes❑No _JLi Building STAFF 11:00 Discharge test ❑✓Yes❑No ❑1/Yes❑No ❑✓Pass❑Fail management: _J N/A Charger test ❑✓Pass❑Fail Building occupants: NA NA ❑✓Yes❑No ❑/Yes El No ]N/A Authority Having Jurisdiction: CAL FIRE 11:00 Remote panel 0 Yes❑No ❑�Yes❑No LJ Pass❑Fail batteries ❑N/A Other,if required: 6.3 Alarm and Supervisory Alarm Initiating Device 8.System Restored To Normal Operation Complete supplementary device test form for all initiating devices. Date: 4/27/2023 6.4 Notification Appliances Time: 11:00 Complete supplementary appliance test form for all notification 9.Comments appliances. Any "No"answers, test failures or other problems found with the fire 6.5 Interface Equipment alarm system must be explained using the comment specific for each Complete supplementary interface component test form for all question.Additional comments can be added here. interface components. Please see the summary section at the top of the form for the Circuit Interface/Signaling Line Circuit Interface/Fire Alarm comments. Control Interface 10.Inspector's Information Inspected By Carlos Palomera Inspector License: 156551 NICET II I state that the information on this form is correct at the time and place of my inspection,and that all equipment tested at this time was left in operating condition upon completion of this inspection except as noted in the Comments.This system as specified herein has been inspected and tested according to NFPA 72,2016 edition,Chapter 14. NFPA 72 v1.1-2019 Page 3 of 4 1�����"'� Eagle3268Esplana Securityd Systems ��� =� EAGLE e SteA ' 0Security Systems Chico,CA 95973 A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395 Signature of Inspector V�---------- Date 4/27/2023 11.Owner or Owner's Representative Owner or Owner's Representative Name Owner or Owner's Representative Signature No Signature Available Date 4/27/2023 NFPA 72 v1.1-2019 Page 4 of 4