HomeMy WebLinkAboutFAI15-0050 041-130-044 Butte College Bldg #11 Phy Sci Qtr Sprk 6.21 (4) Inspection, Testing, and Maintenance Cover Sheet NFPA25 as amended by CCR, Title 19 Property Information: Name: Butte College Women's Locker Room Bldg#19 Occupancy/Use: E _ 3536 Butte Campus Drive Construction Type: �� of CAS/A-1( Address: MI [�' 1� ��''` ii City: Oroville No. Stories: 1 S C( .Ir a ZIP: 95965 Year Constructed: t1y � l:�s Contact: Mark Allen y,, n�P Telephone: (530)893-7590 Contractor Information: Number of System Risers Name: Voltage Specialists Copy sent to: Address: 370 Apple Lane EOwner Date: 06/21/24 City: Paradise ❑Fire AHJ Date: State: California ❑Contractor Date: (530)624-4514 NOTES: Telephone: 1) For specific inspection,testing,and maintenance 880862 requirements and information, see NFPA 25, 2011 CA License#: Edition as amended by California Code of Regulations, Title 19, §901 to§906. Job#: 2)Inspection items may be performed by the owner in Performed b Wyatt C. accordance with California Code of Regulations,Title 19, Y: §904.1(a) Check box for each system inspected and enter the number of forms used for inspection. Check boxes (Fail or Pass)to indicate status of inspected system at end of inspection. Forms Included with Fail* Pass HilliElli1E1 ❑./ Automatic Sprinkler System 5 0 ❑ ✓❑ ❑ Standpipe and Hose System 6 0 ❑ ❑ 1 ❑ ❑ Private Water Supply System 7 0 ❑ ❑ ❑ ❑ Fire Pump 8 0 ❑ ❑ ❑ E Water Storage Tank 9 0 ❑ ❑ ❑ ❑ Water Spray System 10 0 ❑ ❑ ❑ Foam Water Sprinkler System 11 0 ❑ Water Mist System 12 0 ❑./ Concerns that are not deficiencies(i.e. Non-Sprinklered Areas) ❑ Yes ❑✓ No *See "Deficiencies and Comments" section at end of each respective form. AES 1 September 3,2013 Wet Pipe California Code of Regulations -Title 19 Quarterly and 1 of 3 Fire Sprinkler System Inspection, Testing, and Maintenance Annual Report Property Information ";�fc"CF CaCI."0 II Contractor or Licensed Owner Information IB u i l d i n g Name Butte College Women's Locker Room i 1 '/ Name Voltage Specialists 'Address 3536 Butte Campus Drive 7fii e Qom/ Address 370 Apple Lane 3536 Butte Campus Dr. �1y��. F R=� City Paradise St. CA Zip 95969 'CityOroville (License# 880862 IPhone 530-362-2609 'Contact Person I ❑ SFM IJob# Mark Allen I ✓❑ CSLB 'Misc. Riser Information IL. Main Drain Test(Annual) M Riser Location Riser Main Drain Initial Static Residual Final Static p F,N/A No. Diameter Diameter Pressure Pressure Pressure 1 Storage 2.5" 1 1/4" I I I I I II I I I I I I I I I ❑ This building has more than 5 risers. See additional AES 2.9 form attached Number of AES 2.9 forms attached I I Quarterly Inspections 1 =Inspection T=Test M=Maintenance P=Pass F=Fail N/A =Not Applicable Item Description NFPA 25 CA ed. Date Date Date Date Reference 103/22/24 ' ' 06/21/24 1.1 I Control Valves—Identification Sign 13.3.1 P P 1.2 I Control Valves—Inspection 13.3.2 P P 1.3 I Waterflow Alarm Devices 5.2.5 P P 1.4 I Supervisory Devices 5.2.5 N/A N/A N/A N/A 1.5 I Gauges(Wet Pipe Systems) 5.2.4.1 P P 1.6 I Enter Water Supply Pressure Below Riser Check 5.2.4.1 psi psi psi psi 1.7 I Enter Water Supply Pressure Above Riser Check 5.2.4.1 psi psi psi psi 1.8 I Pressure Readings Acceptable 5.2.4.1 P P 1.9 I Hydraulic Design Information Sign 5.2.6 P P (for hydraulically designed systems) 1.10 I General Information Sign 5.2.8 N/A N/A N/A N/A (not required for system prior to 2007 edition of NFPA 13) 1.11 I Heat Tape 5.2.7 N/A N/A N/A N/A 1.12 I Spare Sprinklers 5.2.1.4 P P 1.13 I Fire Department Connections 13.7 N/A N/A N/A N/A 1.14 I Alarm Valves—Exterior Inspection 13.4.1 P P 1.15 I Pressure Reducing Valves 13.5.1.1 N/A N/A N/A N/A 1.16 I Backflow Preventers 13.6.1 N/A N/A N/A N/A 1.17 I Small Hose Connections- Hose Valve* 5.1.6, 13.5.2 N/A N/A N/A N/A 13.5.5.1 1.18 I PRV—Fire Sprinkler Systems 13.5.1.1 N/A N/A N/A N/A *Small hose connections are hose valves and optional hose supplied by the fire sprinkler system. They do not include Class I, II, or III standpipe systems. Form AES 2.1 Sept.3,2013 Wet Pipe California Code of Regulations -Title 19 Quarterly and 2 of 3 Fire Sprinkler System Inspection, Testing, and Maintenance Annual Report "'Si cilt111$ , :,<Property Information � Contractor or Licensed Owner Information 1.0 'Building Name Butte College Women's Locker Room i { Jz''0 'Name Voltage Specialists 'Address 3536 Butte Campus Dr. 'jN ____ 4 'Job# 'City Oroville ', E MR I ANNUAL INSPECTION, TESTING, AND MAINTENANCE miii Include ALL Quarterly Inspections I =Inspection T =Test M=Maintenance P=Pass F=Fail N/A =Not Applicable ItemDescription Reference ate Comments Only P,F,N/A 1.19 I Sprinklers 5.2.1 1.20 I Buildings(Freeze Protection) 4.1.1.1 N/A Owner's Responsibility N/A 1.21 I Pipe and Fittings 5.2.2 1.22 I Hangers 5.2.3 1.23 I Seismic Braces 5.2.3 2.1 T Field Service Test Required 5.3.1 N/A If REQUIRED, Enter'F' until N/A (Send Report to Fire Code Official) results are returned from Lab 2.2 T Recalled Sprinklers Title 19 If not present=Pass; If present=Fail 904.1(c) Water Flow Alarm Devices 5.3.3 2.3 T 90 sec. maximum - (Enter Time) 13.2.6 sec. 2.4 T Main Drain Test 13.2.5 (Enter data on Page 1 of this form) 13.3.3.4 2.5 T Control Valve-Position 13.3.3.2 2.6 T Control Valve—Operation 13.3.3.1 2.7 T Supervisory Devices 13.3.3.5 N/A N/A 2.8 T Backflow Preventer Assemblies 13.6.2 N/A N/A 2 9 T Small Hose Connections* 13.5.2.3 N/A N/A w/PRV Hose Valves—Partial Flow Test 13.5.3.3 2.10 T PRV—Fire Sprinkler Systems 13.5.1.3 N/A N/A 3.1 M Control Valves 13.3.4 3.2 M Small Hose Connections* 13.5.6.3 N/A N/A I Obstruction Investigation required I El Yes '3.3 M (If"Yes" see Deficiencies and Comments Section14.3 No for Results.) 3.4 I M 'System Returned to Service I 4.5.3 I IE Yes I No *Small hose connections are hose valves and optional hose supplied by the fire sprinkler system. They do not include Class I, II, or III standpipe systems. D=Deficiency C=Comment (Indicate type) Item' Date IseilliMi Deficiencies and Comments Indicate all equipment,devices and parts that were repaired or replaced I I I IQ I 1111 I L iLJ I I III I 1 Form AES 2.1 Sept.3,2013 Wet Pipe California Code of Regulations -Title 19 Quarterly and 3 of 3 Fire Sprinkler System Inspection, Testing, and Maintenance Annual Report Property Information "<'7k1)441 Contractor or Licensed Owner Information �f z'�� 'Building Name Butte College Women's Locker Room y [ a Name Voltage Specialists 'Address 3536 Butte Campus Dr. �-I , Job# 'City Oroville ti� E MP D=Deficiency C=Comment (Indicate type) Item Date Riser D C Deficiencies and Comments(cont.) Indicate all equipment,devices and parts that were repaired or replaced _!J 11,1 ELi 11111 ❑Check here if additional Deficiencies and Comments are listed on Form AES9 Number attached: ❑ See Correction Form AES 10 for corrected deficiencies. Number attached: I hereby certify that the fire protection equipment listed above has been fully inspected, tested,and maintained on this date by the company indicated above,in accordance with CCR, Title 19, Sections 901 to 906 and that the equipment is fully operable except as noted in the"Deficiencies and Comments"section of this form. Check box if Annual Inspection, Testing &Maintenance Items are Completed in the Indicated Quarter Quart ❑ Annual Annua riu4th - ❑ Annual Date 03/22/24 06/21/24 Print Name 'Wyatt C. n Wyatt C. Signature Form AES 2.1 Sept.3,2013