HomeMy WebLinkAboutB24-1997 RC3 PLANS - APPROVEDVICINITY MAP (SCALE: NTS) SATELLITE VIEW (SCALE: NTS) EXISTING SHEET INDEX SYSTEM RATING EQUIPMENT SUMMARY ELECTRICAL INFORMATION MAIN SERVICE PANEL BUS SIZE: MAIN SERVICE BREAKER SIZE: RACKING: SWH GROUND MOUNT BUILDING INFORMATION CONSTRUCTION TYPE: V-B OCCUPANCY: R3 GENERAL NOTES 1.All electrical materials shall be new and listed by recognized electrical testing laboratory Custom made equipment shall have complete test data submitted by the manufacturer attesting to its safety 2.Outdoor equipment shall be NEMA 3R rated or equivalent 3.All metallic equipment shall be grounded 4.Contractor shall obtain electrical permits prior to installation and shall coordinate all inspections, testing commissioning and acceptance with the client, utility co. and city inspectors as needed. 5.The electrical contractor shall verify the exact locations of service points and service sizes with the serving utility company and comply with all utility companies requirements. 6.Drawings are diagrammatic only, routing of raceways shall be option of the contractor unless otherwise noted and shall be coordinated with other trades. 7.If the roof material or the roof structure not adequate for PV installation, call the engineer of record prior to installation. The contractor is responsible to verify that the roof is capable of withstanding the extra weight. 8.If the distances for cable runs are different than shown, the contractor shall notify the electrical engineer to validate the wire size. Final drawings will be red-lined and updated as appropriate. 9.Whenever a discrepancy in quality of equipment arises on the drawing or specifications, the contractor shall be responsible for providing and installing all materials and services required by the strictest conditions noted on the drawings or in the specifications to ensure complete compliance and longevity of the operable system required by the engineer of record. PHOTOVOLTAIC NOTES: 1.Ground mounted photovoltaic panels and modules shall be tested, listed and identified by recognized testing laboratory 2.Solar system shall not cover any plumbing or mechanical vents 3.Modules and support structures shall be grounded unless racking has integrated ground. 4.Removal of an interactive inverter or other equipment shall not disconnect the bonding connection between the grounding electrode conductor and the photovoltaic source and/or output circuit grounded conductors. 5.All PV modules and associated equipment and wiring shall be protected from physical damage. 6.Live parts of PV source circuits and PV output circuits over 150v to ground shall not be accessible to other than qualified persons while energized. 7.Inverter is equipped with integrated DC disconnect, thus providing ground fault protection 8.All conductors shall be copper and 75 deg rated 9.A single conductor shall be permitted to be used to perform the multiple functions of dc grounding, AC grounding and bonding between AC and DC systems. 10. Non-current carrying metal parts of equipment shall be effectively bonded together. Bond both ends of raceways. 200A DC 12.600 KW STC AC 8.120 KW STC SITE MAP & PV LAYOUT ELECTRICAL 1-LINE DIAGRAM ATTACHMENT LAYOUT SYSTEM LABELING DETAIL INVERTER DATA SHEET PROPERTY PLAN MODULE DATA SHEET RACKING DATA SHEET PV 1.0 PV 2.0 PV 3.0 PV 4.0 PV 5.0 D 6.0 D 7.0 D 8.0 28 ZNSHINE SOLAR 450 WATT MODULES WITH 28 IQ8PLUS ENPHASE MICROINVERTER 200A APN Number: 08/21/2024 Property Address: Owner: 040020092 Kassidy Lesch Property Type:Single Family Residence Drawn by:New@engineerinc.io Date: 162 McFadden Ln, Chico, CA 95928 THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: ·2020 National Electrical Code ·2022 California Building Code ·2022 California Residential Code ·2022 California Green Building Standard Code ·2022 California Plumbing Code ·2022 California Mechanical Code ·2022 California Electrical Code ·2022 California Fire Code ·2022 California Energy Code ·2016 International Property Maintenance Code ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES GOVERNING CODES CONTRACTOR Marks Solar Address:1632 Garden Rd, Durham, CA 95938 Phone number: 530-680-7331 Lic: 701317 RSD DATA SHEET D 9.0 COMBINER BOX DATA SHEET D 10.0 These drawings are protected by copyright under US alaw. Any form of reproduction is strictly prohibited without prior written approval from Engineerinc. Phone number:(310)-928-0938 JB Ground Mounted Solar PV Array 28 - ZNshine 450W Modules 28 - Enphase IQ8+Microinverters Pitch: 30 Deg Orientation: 189 Deg ECB AC LEECH LINEMcFadden LnWELL SEPTIC TANK AC wiring ~ 30 feet Underground run 2" Schedule # 50 PVC Pipe 24" Min depth MSP a a a a a a aa b b a a b b c c b bc c b b c c b b c c SITE MAP & PV LAYOUT PV 1.0 PV SYSTEM AS INDICATED Scale:Project: Project Name: Property Address: Kassidy Lesch 162 McFadden Ln, Chico, CA 95928 SOLAR MODULES ___ Znshine Solar 450 Watt Model #ZXM6-NH144 EMT type Conduit Solar Module ...................... ..................... ............. 28 INDEX (N) Microinverter Phone Number: (310) 928-0938 DATE:08/21/2024 INVERTER INVERTER TYPE: Micro ____ Enphase IQ8+ Model: IQ8PLUS-72-2-US MSP (E) Main Service Panel200A AC............(N) 60A AC Disconnect CONTRACTOR Marks Solar Address:1632 Garden Rd, Durham, CA 95938 Phone number: 530-680-7331 Lic: 701317 Drawn by:New@engineerinc.io 28 ECB.......(N) Enphase IQ Combiner PVC type Conduit............. FMT type Conduit............. SCALE:1/8" = 1'-0" 180 ° 90 ° 270 ° 0° S W N E 10’ vegetation free zone around entire array Covered with gravel PV 2.0 PV SYSTEM AS INDICATED Scale:Project: ELECTRICAL 1-LINE DIAGRAM CONTRACTOR Marks Solar Address:1632 Garden Rd, Durham, CA 95938 Phone number: 530-680-7331 Lic: 701317 Project Name: Property Address: Kassidy Lesch 162 McFadden Ln, Chico, CA 95928 Phone Number: (310) 928-0938 DATE:08/21/2024 Drawn by:New@engineerinc.io 1 8BRANCH - C2 J BOX NEMA3R ZNSHINE 450 W MODULES ENPHASE IQ8+ MICROINVERTERS ENPHASE Q CABLE (2)#12 AWG PV WIRE (1)#6 AWG EGC FREE IN THE AIR (2) #14 AWG THWN/ THWN-2 PV Monitoring Device 15A IQ Combiner 4/4C (6) #10 AWG THWN/THWN-2 (1) #8 AWG GND 3/4" EMT, 3 FEET INSTALL (3)20A PV 2-POLE C/B 1 10BRANCH - B2 28 28 EXISTING ______ MAIN SERVICE PANEL 120/240V, 1P, 3W EXISTING NON CENTER _____ MAIN C/B GEC (E) GROUNDING ELECTRODE SYSTEM MAIN METER 200A 60A NON-FUSED, VISIBLE LOCKABLE LABELED AC DISCONNECT, WITH 50A FUSES BLADE TYPE, NEMA3R 120 / 240V (UTILITY REQUIRED) 200A (3) #8 AWG THWN/THWN-2 (1) #8 AWG GND 3/4" EMT, 2 FEET (3) #6 AWG THWN/THWN-2 (1) #8 AWG GND 3/4" EMT, 3 FEET NOTE: Service Panel does not contain center fed Main Breaker: AC wiring ~ 30 feet Underground run 2" Schedule # 50 PVC Pipe 24" Min depth 1 10BRANCH - A2 CUSTOMER SIDE TAP USING POLARIS BLOCK POLARIS Insulated Multitap Connector: IT 1/0, 2 Ports, For Wire Sizes 14 AWG – 1/0 AWG PV ARRAY RATING WIRE SIZE CALCULATION BRANCH CIRCUIT - A BRANCH CIRCUIT - A Number Modules 10 ZXM6-NH144 Znshine Solar 450 Watt Number OF Microinverters in Circuit 10 Number MicroInverters 10 Enphase IQ8+ Microinverters IQ8Plus-72-2-US(240V)Microinverter Maximum Output Current (A)1.21 Total DC Wattage (Watts)Watts STC, (Watts/Module) 10 * 450 = 4500 Branch Circuit Total Current (A)10 * 1.21 * 1.25 = 15.13 Array Currents I-SC 11.47 A I-MP 10.88 A Breaker Size Per Branch Circuit (A)20 Module Voltage V-OC 50.3 V V-MP 41.4 V BRANCH CIRCUIT - B BRANCH CIRCUIT - B Number Modules Number OF Microinverters in Circuit 10 Number MicroInverters Enphase IQ8+ Microinverters IQ8Plus-72-2-US(240V)Microinverter Maximum Output Current (A)1.21 Total DC Wattage (Watts)Branch Circuit Total Current (A)10 * 1.21 * 1.25 = 15.13 Array Currents I-SC 11.47 A I-MP 10.88 A Breaker Size Per Branch Circuit (A)20 Module Voltage V-OC 50.3 V V-MP 41.4 V BRANCH CIRCUIT - C BRANCH CIRCUIT - C Number Modules 8 Number OF Microinverters in Circuit 8 Number MicroInverters 8 Enphase IQ8+ Microinverters IQ8Plus-72-2-US(240V)Microinverter Maximum Output Current (A)1.21 Total DC Wattage (Watts)Watts STC, (Watts/Module) 8 * 450 = 3600 Branch Circuit Total Current (A)8 * 1.21 * 1.25 = 12.1 Array Currents I-SC 11.47 A I-MP 10.88 A Breaker Size Per Branch Circuit (A)20 Module Voltage V-OC 50.3 V V-MP 41.4 V FROM JBOX TO ENPHASE COMBINER BOX Maximum Continuous Current (A)15.13 More Than 3 CCC Adjustment Factor 0.8 Adjusted Conductor Ampacity(A)15.13 / 0.8 = 18.91 Raceway Height From Roof (Temp 39+22=61C)3 1/2"# of wire( # BC *2)6 Ambient Temp Factor Per NEC Table 310.15(b)(2)(a)0.71 Temp. Derate Factor (max. Continuous current divided ambient tem. Factor (A)18.91 / 0.71 = 26.64 Wire Size from NEC Table 310.15(b)16 10 AWG FROM ENPHASE COMBINER BOX TO AC DISCONNECT Total Number Of Microinverters 28 Total Amps From All Microinverters (A)28 * 1.21 = 33.88 Consider Continuous (A)33.88 * 1.25 = 42.35 Temp. Derate Factor(0.91 at wall of the Building) (A)42.35 / 0.91 = 46.54 Wire Size from NEC Table 310.15(b)16 8 AWG Ambient Temp Factor Per NEC Table 310.15(b)(2)(a)0.91 (3) #6 AWG THWN/THWN-2 (1) #8 AWG GND 3/4" FMT, 42 FEET ZXM6-NH144 Znshine Solar 450 Watt ZXM6-NH144 Znshine Solar 450 Watt 10 10 Watts STC, (Watts/Module) 10 * 450 = 4500 (E) NEW GROUNDING ELECTRODE SYSTEM ADDITIONAL GROUND ROD PER C.E.C Article 690.47 and 250 CUSTOMER SIDE TAP WITH POLARIS BLOCK SEE SHEET D 11 for datasheet EXISTING 125A SUB PANEL (3) #4/0 AWG THWN/THWN-2 (1) #1 AWG GND SERVICE POINT & UTILITY METERING You Are Here GROUND MOUNTED SOLAR PV ARRAY ENPHASE COMBINER BOX AC DISCONNECT SYSTEM LABELING DETAIL PV 3.0 PV SYSTEM AS INDICATED Scale:Project: (STICKER TO BE LOCATED ON CONDUIT WITH DC CURRENT EVERY 4' HORIZONTALLY OR 10' VERTICALLY AND 1' FROM EACH SIDE OF A BEND) (TO BE LOCATED ON SUB-PANEL ONLY WHEN SUB-PANEL IS DEDICATED FOR PV ONLY) (STICKER LOCATED INSIDE PANEL NEXT TO SOLAR BREAKER) (STICKER LOCATED INSIDE PANEL BELOW PV BREAKER) PV ARRAY J BOX INVERTER INTEGRATED DC DISCONNECT PV SUB-PANEL * if applicable SUB-PANEL * if applicable AC DISCONNECT * if applicable METER MAIN SERVICE PANEL *if applicable (STICKER LOCATED ON THE PV SUB PANEL) CAUTION AUTHORIZED SOLAR PERSONNAL ONLY! CAUTION SOLAR DC CURRENT PRESENT DURING DAYLIGHT HOURS WARNING! ELECTRIC SHOCK HAZARD. IF GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED. DC DISCONNECT DC PHOTOVOLTAIC POWER SOURCE RATED MAX POWER POINT CURRENT- AMPS RATED MAX POWER POINT VOLTAGE- VOLTS MAXIMUM SYSTEM VOLTAGE- VOLTS SHORT CIRCUIT CURRENT- AMPS WARNING! ELECTRIC SHOCK HAZARD. DO NOT TOUCH THE TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. PV LOAD CENTER SIZED FOR PV BREAKERS ONLY OR RENDERED UNABLE TO ACCEPT ANY ADDITIONAL LOADS. PV SUB-PANEL ONLY AC DISCONNECT AC PHOTOVOLTAIC POWER SOURCE RATED AC OUTPUT CURRENT: A MAX NOMINAL AC OPERATING VOLTAGE: 480 Vac THIS PANEL FED BY MULTIPLE SOURCES (UTILITY & SOLAR) SOLAR WARNING! INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanently attached to the equipmenq or in the required location using an approved method that is suitable to withstand the environment to which it is exposed. Plaques and signage shall meet legibility, defacemet, exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). 42.35 LABEL 1 LABEL 2 LABEL 3 LABEL 4 LABEL 5 LABEL 6 LABEL 7 LABEL 8 LABEL 9 LABEL 10 LABEL 11 LABEL 12 87 109 12 7 7 9 8 10 7 7 9 8 1011 7 4 51 2 DIRECTORY MARKINGS, LABELS AND WIRING SIGNS A. Purpose: Provide emergency responders with appropriate warning and guidance with respect to isolating solar electric system. This can facilitate identifying energized electrical lines that connect solar panels to the inverter, as these should not be cut when venting for smoke removal B. Main Service Disconnect. 1. Residential buildings - The marking main be placed within the main service disconnect. The marking shall be placed outside cover if the main service disconnect is operable with the service panel closed. 2. Commercial buildings - Tha marking shall be placed adjacent to the main service disconnect clearly visible from the location where the level is operated 3. Markings: Verbiage, Format and Type of Material. a. Verbiage: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED b. Format: White lettering on a red background. Minimum 3/8 inches letter height. All letters shall be capitalized. Arial or similar font, non bold. c. Material: Reflective, weather resistant material suitable for the environment (use UL - 969 as standard for weather rating). Durable adhesive materials meet this requirement. C.Marking Requirements on DC conduit, raceways, enclosures, cable assemblies, DC combiners and junction boxes: 1. Markings: Verbiage, Format and Type of Material. a. Placement : Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies, at turns, above and for below penetrations, all DC combiners and junction boxes b. Verbiage: CAUTION: SOLAR CIRCUIT Note: The format and type of material shall adhere to "V. V-3b, c" of this requirement. c. Inverters are not required to have caution markings 1.Marking is required on all interior and exterior DC conduit raceways,enclosures,cable assemblies,and junction boxes,combiner boxes and disconnects. 2.The materials used for marking shall be reflective,weather resistant material suitable for the environment. Minimum 3/8 "letter height; all upper case letters Arial or similar font; Red background with white lettering. 3.Marcking shall contain the words: WARNING : PHOTOVOLTAIC POWER SOURCE. 4.Marking shall be placed adjacent to the main service disconnect in a location clearly visible from the location where the disconnect is operated SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: CONTRACTOR Marks Solar Address:1632 Garden Rd, Durham, CA 95938 Phone number: 530-680-7331 Lic: 701317 Project Name: Property Address: Kassidy Lesch 162 McFadden Ln, Chico, CA 95928 Phone Number: (310) 928-0938 DATE:08/21/2024 Drawn by:New@engineerinc.io MSP 234'-3" 404'-7" 310' ECB ACMcFadden LnDRIVEWAY WELL SEPTIC TANK GATE 25' 25' 136'-7" LEECH LINE 5' 30' 50' PROPERTY PLAN PV 4.0 PV SYSTEM AS INDICATED Scale:Project: MSP Main Service Panel AC.........................AC Disconnect Solar Module..................... ................ CONTRACTOR Marks Solar Address:1632 Garden Rd, Durham, CA 95938 Phone number: 530-680-7331 Lic: 701317 Project Name: Property Address: Kassidy Lesch 162 McFadden Ln, Chico, CA 95928 Phone Number: (310) 928-0938 DATE:08/21/2024 Drawn by:New@engineerinc.io ECB...........Enphase IQ Combiner INDEX SCALE:1/32" = 1'-0" 180 ° 90 ° 270 ° 0° S W N E 48'-5" 13'-7" 2'-9" 2'-9" 8'8'8'8'8'8' 13'-9"ATTACHMENT LAYOUT PV 5.0 PV SYSTEM AS INDICATED Scale:Project: CONTRACTOR Marks Solar Address:1632 Garden Rd, Durham, CA 95938 Phone number: 530-680-7331 Lic: 701317 Project Name: Property Address: Kassidy Lesch 162 McFadden Ln, Chico, CA 95928 Phone Number: (310) 928-0938 DATE:08/21/2024 Drawn by:New@engineerinc.io MODULE WEIGHT (lbs) # OF MODULES TOTAL MODULE WEIGHT (lbs) RACK WEIGHT (lbs) TOTAL SYSTEM WEIGHT (lbs) # OF PIERS MAX SPAN BETWEEN PIERS (in) LOADING PER PIER (lbs) TOTAL AREA (sq.ft.) LOADING (PSF) WEIGHT LOAD CALCULATION 52.91 1481.48 296.29 1844.41 8' 14 131.74 2.99 616 SWH RAIL PIER CROSS RAIL SOLAR MODULE 28 SCHEDULE 40 CROSS PIPE 2" SWH PIPE TO RAIL ADAPTOR SWH STANDARD RAIL SWH SLIDER BRACKET 30° 3.5' GROUND LEVEL MICROINVERTER WEIGHT (lbs)66.64 24" CROSS PIPE 2" 8' Ground Mounted Solar PV Array Pitch: 30 Deg Orientation: 189 Deg 6'-11" 18"1'-2" 2'-9" 2'-3" 13'-9" 8' 2'-9" INVERTER DATA SHEET D 6.0 PV SYSTEM AS INDICATED Scale:Project: CONTRACTOR Marks Solar Address:1632 Garden Rd, Durham, CA 95938 Phone number: 530-680-7331 Lic: 701317 Project Name: Property Address: Kassidy Lesch 162 McFadden Ln, Chico, CA 95928 Phone Number: (310) 928-0938 DATE:08/21/2024 Drawn by:New@engineerinc.io D 7.0 PV SYSTEM AS INDICATED Scale:Project: CONTRACTOR Marks Solar Address:1632 Garden Rd, Durham, CA 95938 Phone number: 530-680-7331 Lic: 701317 RSD DATA SHEET Project Name: Property Address: Kassidy Lesch 162 McFadden Ln, Chico, CA 95928 Phone Number: (310) 928-0938 DATE:08/21/2024 Drawn by:New@engineerinc.io D 8.0 PV SYSTEM AS INDICATED Scale:Project: MODULE DATA SHEET CONTRACTOR Marks Solar Address:1632 Garden Rd, Durham, CA 95938 Phone number: 530-680-7331 Lic: 701317 Project Name: Property Address: Kassidy Lesch 162 McFadden Ln, Chico, CA 95928 Phone Number: (310) 928-0938 DATE:08/21/2024 Drawn by:New@engineerinc.io RACKING DATA SHEET D 9.0 PV SYSTEM AS INDICATED Scale:Project: CONTRACTOR Marks Solar Address:1632 Garden Rd, Durham, CA 95938 Phone number: 530-680-7331 Lic: 701317 Project Name: Property Address: Kassidy Lesch 162 McFadden Ln, Chico, CA 95928 Phone Number: (310) 928-0938 DATE:08/21/2024 Drawn by:New@engineerinc.io D 10.0 PV SYSTEM AS INDICATED Scale:Project: COMBINER BOX DATA SHEET CONTRACTOR Marks Solar Address:1632 Garden Rd, Durham, CA 95938 Phone number: 530-680-7331 Lic: 701317 Project Name: Property Address: Kassidy Lesch 162 McFadden Ln, Chico, CA 95928 Phone Number: (310) 928-0938 DATE:08/21/2024 Drawn by:New@engineerinc.io D 11.0 PV SYSTEM AS INDICATED Scale:Project: COMBINER BOX DATA SHEET CONTRACTOR Marks Solar Address:1632 Garden Rd, Durham, CA 95938 Phone number: 530-680-7331 Lic: 701317 Project Name: Property Address: Kassidy Lesch 162 McFadden Ln, Chico, CA 95928 Phone Number: (310) 928-0938 DATE:08/21/2024 Drawn by:New@engineerinc.io