HomeMy WebLinkAboutFAI19-0037 2024-08-15 CF FA 2024Fire Alarm and Life Safety System Inspection Certificate For Sycamore Middle School 1125 Sycamore Street Gridley, CA 95948 Tested to NFPA 72 Standards This Inspection was performed in accordance with applicable NFPA Standards. The subsequent pages of this report provide performance measurements, listed ranges of acceptable results, and complete documentation of the inspection. Whenever discrepancies exist between acceptable performance standards and actual test results, notes and/or recommended solutions have been proposed or provided for immediate review and approval. Annual Inspection Inspection Date Aug 15, 2024 Building: Sycamore Middle School Company: Hue & Cry, Inc. Contact: Jordan Reeves Contact: Nick Kuykendall Title: Superintendent Title: INSPECTOR/TECHNICIAN Fire Alarm Testing Report Page of 2 14 Executive Summary Hue & Cry, Inc.Download Date: 08/16/2024 Executive Summary Generated by: BuildingReports.com Building Information Building: Sycamore Middle School Contact: Jordan Reeves Address: 1125 Sycamore Street Phone: 1-530-846-34721 Address: Fax: City/State/ZIP Code: Gridley, CA 95948 Mobile: Country: United States of America Email: jreeves@gusd.org Inspection Performed By Company: Hue & Cry, Inc.Inspector: Nick Kuykendall Address: 1751 Bruce Drive Phone: 800-800-alarm Address: Fax: City/State/ZIP Code: Anderson, California 96007 Mobile: Country: United States of America Email: n.kuykendall@hueandcry.com System Control Unit Manufacturer: Honeywell Inspection Date: 08/14/2024 IDC Style: B Model Number: 6820EVS Install Date: 10/17/1995 SLC Style: Software Version: Version Date: 10/17/1995 NAC Style: Y Location: Office Current Protection: Breaker OfficeDisconnect Location:Type: Breaker Page of 3 14 Executive Summary Hue & Cry, Inc.Download Date: 08/16/2024 Inspection Summary Category:Total Items Serviced Passed Failed/Other Qty %Qty %Qty %Qty % Control 16 16.49%16 100.00%8 50.00%8 50.00% Indicating 54 55.67%54 100.00%53 98.15%1 1.85% Initiating 27 27.84%27 100.00%27 100.00%0 0.00% Totals 97 100%97 100.00%88 90.72%9 9.28% Certification Company: Hue & Cry, Inc.Building: Sycamore Middle School Inspector: Nick Kuykendall Contact: Jordan Reeves Signed: Aug 14, 2024 Signed: Nick Kuykendall Certifications Certification Type Number C-10 Electrical Licensed Contractor 620587 Page of 4 14 Discrepancy Report Hue & Cry, Inc.Download Date: 08/16/2024 Discrepancy Report Generated by: BuildingReports.com Building: Sycamore Middle School Control Panel: 1 - Honeywell 6820EVS The Discrepancy Report consolidates each discrepancy listed within the various Testing sections of your Inspection. Discrepancies are listed by Category, and grouped by device type. The description of the problem is provided and where appropriate, code references are listed for your convenience. Any item that was inspected that is subject to a recall or part of a manufacturer’s replacement/upgrade program is included. Device Type Manufacturer ModelNumber Date Qty Items listed for Recall or Replacement/Upgrade No items found during this inspection. ScanID Location Problem Address Reference Control Battery 1 61625370 Extender Panel Date Expired 1 NFPA72 Table 14.4.3.2 (9)c(1) 1 61625371 Extender Panel Date Expired 1 NFPA72 Table 14.4.3.2 (9)c(1) 1 61625375 FACP Failed Test 1 NFPA72 Table 14.4.3.2 (9)c(1) 1 61625376 FACP Failed Test 1 NFPA72 Table 14.4.3.2 (9)c(1) 1 61625365 Portable 21 EVS Power Supply (L) Date Expired 1 NFPA72 Table 14.4.3.2 (9)c(1) 1 61625366 Portable 21 EVS Power Supply (R) Date Expired 1 NFPA72 Table 14.4.3.2 (9)c(1) 1 61625363 Portable 21 Power Supply (L) Date Expired 1 NFPA72 Table 14.4.3.2 (9)c(1) 1 61625364 Portable 21 Power Supply (R) Date Expired 1 NFPA72 Table 14.4.3.2 (9)c(1) Indicating Horn 2 11531557 Library Failed Operation 1 NFPA72 14.2.2.2.2 Code References NFPA72 Table 14.4.3.2 (9)c (1) Batteries shall be replaced in accordance with the recommendations of the alarm equipment manufacturer or when the recharged battery voltage or current falls below the manufacturer's recommendations NFPA72 14.2.2.2.2 System deficiencies shall be corrected. Page of 5 14 Proposed Solutions Report Hue & Cry, Inc.Download Date: 08/16/2024 Proposed Solutions Report Generated by: BuildingReports.com Building: Sycamore Middle School Control Panel: 1 - Honeywell 6820EVS The Proposed Solution Report provides a solution for each discrepancy listed on the Discrepancy Report. Provide a check mark where indicated to approve repairs listed within the report. Items listed as T/M are available for repair on a Time and Materials basis. ScanID Location Solution Model #Cost Fix Control Battery 61625370 Extender Panel Replace Battery DURA12 T/M 61625371 Extender Panel Replace Battery DURA12-8F2 T/M 61625375 FACP Replace Battery DURA12-8F2 T/M 61625376 FACP Replace Battery DURA12-8F2 T/M 61625365 Portable 21 EVS Power Supply (L)Replace Battery DURA12-8F2 T/M 61625366 Portable 21 EVS Power Supply (R)Replace Battery DURA12 T/M 61625363 Portable 21 Power Supply (L)Replace Battery DURA12-8F2 T/M 61625364 Portable 21 Power Supply (R)Replace Battery DURA12-8F2 T/M Indicating Horn 11531557 Library Investigate 2901-9838 T/M PO #: (none)T/M Page of 6 14 Notes & Recommendations Hue & Cry, Inc.Download Date: 08/16/2024 Notes & Recommendations Generated by: BuildingReports.com Building: Sycamore Middle School The Notes & Recommendations Report details additional inspection notes made by the Inspectors during the course of the building inspection. Notes are grouped by Category. General Note All batteries expired and need to be replaced (8) 12v8ah batteries (12v7ah should work as well) Horn in library did not go off while testing audibles Page of 7 14 Inspection & Testing Hue & Cry, Inc.Download Date: 08/16/2024 Inspection & Testing Generated by: BuildingReports.com Building: Sycamore Middle School Control Panel: 1 - Honeywell 6820EVS The Inspection & Testing section lists all of the items inspected in your building. Items are grouped by Passed or . Items are listed by Category. Each item includes the services performed, and the time & date at which testing Failed/Other occurred. Device Type Location Service Time Date Passed Control Communication Line Office Annual 12:22:05 PM 08/14/2024 Communication Line Office Annual 12:22:13 PM 08/14/2024 Control Panel Office Annual 11:18:14 AM 08/14/2024 Disconnect Nurses Office Circuit Breaker #13 Annual 7:40:26 AM 08/15/2024 Disconnect Portable 21 Breaker 13 Annual 7:40:30 AM 08/15/2024 Indicating Horn Counselors Office Annual 11:43:20 AM 08/14/2024 Horn Gym East Annual 11:43:46 AM 08/14/2024 Horn Hall by Room 15 Annual 11:43:27 AM 08/14/2024 Horn Main Hall by Rooms 2-3 Annual 11:43:06 AM 08/14/2024 Horn Nurses Office Annual 11:43:10 AM 08/14/2024 Horn Office Conference Room Annual 11:43:23 AM 08/14/2024 Horn Offices for Counselors Annual 11:43:13 AM 08/14/2024 Horn Outside by Room 22 Annual 11:43:33 AM 08/14/2024 Horn Outside by Room 23 Annual 11:43:36 AM 08/14/2024 Horn Outside by Rooms 19 Annual 11:43:43 AM 08/14/2024 Horn Outside by Rooms 21 Annual 11:43:40 AM 08/14/2024 Horn Staff Lounge Annual 11:43:30 AM 08/14/2024 Horn Office Annual 11:43:17 AM 08/14/2024 Horn/Strobe Band Room Annual 11:47:05 AM 08/14/2024 Horn/Strobe Boys R/R Outside Main Bldg Annual 11:47:02 AM 08/14/2024 Horn/Strobe Boys R/R by Media Room Annual 11:44:51 AM 08/14/2024 Horn/Strobe Girls R/R by Media Room Annual 11:44:54 AM 08/14/2024 Horn/Strobe Hall by Girls R/R by Main Bldg Annual 11:44:09 AM 08/14/2024 Horn/Strobe Main Hall West near Storage Annual 11:46:19 AM 08/14/2024 Horn/Strobe Main Hall by Rooms 5-6 Annual 11:43:59 AM 08/14/2024 Horn/Strobe Office Lobby Annual 11:44:02 AM 08/14/2024 Page of 8 14 Inspection & Testing Hue & Cry, Inc.Download Date: 08/16/2024 Device Type Location Service Time Date Passed Horn/Strobe Outside Main Bldg West Annual 11:44:05 AM 08/14/2024 Horn/Strobe Storage by Rooms 15-16 Annual 11:44:45 AM 08/14/2024 Horn/Strobe Portables 17 Annual 11:47:09 AM 08/14/2024 Horn/Strobe Portables 17 Annual 11:47:12 AM 08/14/2024 Horn/Strobe Portables 18 Annual 11:46:24 AM 08/14/2024 Horn/Strobe Portables 18 Annual 11:46:56 AM 08/14/2024 Horn/Strobe Portables 19 Annual 11:46:31 AM 08/14/2024 Horn/Strobe Portables 19 Annual 11:46:37 AM 08/14/2024 Horn/Strobe Portables 20 Annual 11:46:40 AM 08/14/2024 Horn/Strobe Portables 20 Annual 11:46:44 AM 08/14/2024 Horn/Strobe Portables 21 Annual 11:46:47 AM 08/14/2024 Horn/Strobe Portables 21 Annual 11:46:51 AM 08/14/2024 Horn/Strobe Room 1 Annual 11:45:04 AM 08/14/2024 Horn/Strobe Room 10 Annual 11:46:07 AM 08/14/2024 Horn/Strobe Room 11 Annual 11:45:54 AM 08/14/2024 Horn/Strobe Room 12 Annual 11:45:43 AM 08/14/2024 Horn/Strobe Room 13 Annual 11:45:14 AM 08/14/2024 Horn/Strobe Room 14 Annual 11:45:11 AM 08/14/2024 Horn/Strobe Room 15 Annual 11:44:48 AM 08/14/2024 Horn/Strobe Room 16 Annual 11:44:42 AM 08/14/2024 Horn/Strobe Room 2 Annual 11:45:39 AM 08/14/2024 Horn/Strobe Room 23 Annual 11:43:53 AM 08/14/2024 Horn/Strobe Room 23 Restroom Annual 11:43:50 AM 08/14/2024 Horn/Strobe Room 3 Annual 11:45:48 AM 08/14/2024 Horn/Strobe Room 4 Annual 11:45:51 AM 08/14/2024 Horn/Strobe Room 5 Annual 11:45:57 AM 08/14/2024 Horn/Strobe Room 6 Annual 11:46:00 AM 08/14/2024 Horn/Strobe Room 7 Annual 11:46:14 AM 08/14/2024 Horn/Strobe Room 8 Annual 11:43:56 AM 08/14/2024 Horn/Strobe Room 9 Annual 11:46:10 AM 08/14/2024 Strobe Counselors R/R Annual 12:20:29 PM 08/14/2024 Strobe Nurses R/R Annual 12:20:26 PM 08/14/2024 Initiating Heat Detector Portable 17 Annual 12:17:57 PM 08/14/2024 Heat Detector Portable 18 Annual 12:17:44 PM 08/14/2024 Heat Detector Portable 19 Annual 12:17:47 PM 08/14/2024 Heat Detector Portable 20 Annual 12:17:51 PM 08/14/2024 Page of 9 14 Inspection & Testing Hue & Cry, Inc.Download Date: 08/16/2024 Device Type Location Service Time Date Passed Heat Detector Portable 21 Annual 12:17:54 PM 08/14/2024 Pull Station Band Room Annual 12:20:34 PM 08/14/2024 Pull Station Gym East Annual 12:04:28 PM 08/14/2024 Pull Station Gym North Annual 12:05:24 PM 08/14/2024 Pull Station Gym West Exit Annual 12:03:19 PM 08/14/2024 Pull Station Hall by Room 15 Annual 12:07:55 PM 08/14/2024 Pull Station Main Hall between rooms 5-6 Annual 11:56:24 AM 08/14/2024 Pull Station Cafeteria Annual 12:07:51 PM 08/14/2024 Pull Station Kitchen Annual 12:09:05 PM 08/14/2024 Pull Station Main hall betwen rooms 2-3 Annual 11:57:36 AM 08/14/2024 Pull Station Room 22 Annual 12:00:14 PM 08/14/2024 Pull Station Room 23 Annual 12:00:51 PM 08/14/2024 Smoke Detector Office Above FACP Annual 11:50:56 AM 08/14/2024 Smoke Detector Portable 17 Annual 12:20:00 PM 08/14/2024 Smoke Detector Portable 17 Annual 12:20:03 PM 08/14/2024 Smoke Detector Portable 18 Annual 12:18:11 PM 08/14/2024 Smoke Detector Portable 18 Annual 12:19:57 PM 08/14/2024 Smoke Detector Portable 19 Annual 12:19:21 PM 08/14/2024 Smoke Detector Portable 19 Annual 12:19:24 PM 08/14/2024 Smoke Detector Portable 20 Annual 12:19:31 PM 08/14/2024 Smoke Detector Portable 20 Annual 12:19:34 PM 08/14/2024 Smoke Detector Portable 21 Annual 12:19:49 PM 08/14/2024 Smoke Detector Portable 21 Annual 12:19:53 PM 08/14/2024 Device Type Location Service Time Date Failed/Other Control 1 Battery Extender Panel Annual 11:28:46 AM 08/14/2024 1 Battery Extender Panel Annual 11:29:14 AM 08/14/2024 1 Battery FACP Annual 11:25:36 AM 08/14/2024 1 Battery FACP Annual 11:26:51 AM 08/14/2024 1 Battery Portable 21 EVS Power Supply (L) Annual 12:13:53 PM 08/14/2024 1 Battery Portable 21 EVS Power Supply (R) Annual 12:14:25 PM 08/14/2024 1 Battery Portable 21 Power Supply (L) Annual 12:13:25 PM 08/14/2024 1 Battery Portable 21 Power Supply (R) Annual 12:12:46 PM 08/14/2024 Indicating 2 Horn Library Annual 11:42:43 AM 08/14/2024 Page of 10 14 Inspection & Testing Hue & Cry, Inc.Download Date: 08/16/2024 Building: Sycamore Middle School Control Panel: 2 The Inspection & Testing section lists all of the items inspected in your building. Items are grouped by Passed or . Items are listed by Category. Each item includes the services performed, and the time & date at which testing Failed/Other occurred. Device Type Location Service Time Date Passed Control Power Supply Office Annual 11:18:55 AM 08/14/2024 Power Supply Portable 21 Annual 12:12:25 PM 08/14/2024 Power Supply Portable 21 Annual 12:18:05 PM 08/14/2024 Page of 11 14 Service Summary Hue & Cry, Inc.Download Date: 08/16/2024 Service Summary Generated by: BuildingReports.com Building: Sycamore Middle School The Service Summary section provides an overview of the services performed in this report. Device Type Service Quantity Failed/Other Battery Annual 8 Horn Annual 1 Total 9 Passed Communication Line Annual 2 Control Panel Annual 1 Disconnect Annual 2 Heat Detector Annual 5 Horn/Strobe Annual 38 Horn Annual 13 Power Supply Annual 3 Pull Station Annual 11 Smoke Detector Annual 11 Strobe Annual 2 Total 88 Grand Total 97 Page of 12 14 Battery & Power Supply Testing Hue & Cry, Inc.Download Date: 08/16/2024 Battery & Power Supply Testing Generated by: BuildingReports.com Building: Sycamore Middle School Control Panel: 1 - Honeywell 6820EVS The Battery & Power Supply Testing section details the readings and measurements of batteries and power supplies used to provide power to the fire alarm and life safety systems. Items are grouped by Passed or Failed/Other. Type Location Rated Ah Rated Volts Pre Test Post Test Min Ah Tested Ah Battery Failed/Other Sealed Lead Acid Extender Panel 7 12 12.91 4.55 7.2 Sealed Lead Acid Extender Panel 7 12 12.91 4.55 6.8 Sealed Lead Acid FACP 8 12 12.91 4.55 2.1 Sealed Lead Acid FACP 8 12 12.91 4.55 4.2 Sealed Lead Acid Portable 21 EVS Power Supply (L) 7 12 Sealed Lead Acid Portable 21 EVS Power Supply (R) 7 12 Sealed Lead Acid Portable 21 Power Supply (L) 7 12 Sealed Lead Acid Portable 21 Power Supply (R) 7 12 Page of 13 14 Inventory & Warranty Report Hue & Cry, Inc.Download Date: 08/16/2024 Inventory & Warranty Report Generated by: BuildingReports.com Building: Sycamore Middle School Control Panel: 1 - Honeywell 6820EVS The Inventory & Warranty Report lists each of the devices and items that are included in your Inspection Report. A complete inventory count by device type and category is provided. Items installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together for easy reference. Device or Type Category % of Inventory Quantity Battery Control 8.25%8 Communication Line Control 2.06%2 Control Panel Control 1.03%1 Disconnect Control 2.06%2 Heat Detector Initiating 5.15%5 Horn Indicating 14.43%14 Horn/Strobe Indicating 39.18%38 Power Supply Control 3.09%3 Pull Station Initiating 11.34%11 Smoke Detector Initiating 11.34%11 Strobe Indicating 2.06%2 Type Qty Model #Description Install Date In Service - 3 Years to 5 Years Duracell Battery 1 DURA12-8F2 Sealed Lead Acid 01/21/2020 Battery 1 DURA12-8F2 Sealed Lead Acid 09/24/2019 Battery 1 DURA12 Sealed Lead Acid 08/22/2019 Battery 3 DURA12-8F2 Sealed Lead Acid 08/22/2019 In Service - 5 Years to 10 Years Duracell Battery 1 DURA12 Sealed Lead Acid 01/21/2019 Battery 1 DURA12-8F2 Sealed Lead Acid 01/21/2019 Fire-Lite Heat Detector 5 H365 Rate-of-Rise 10/22/2014 Honeywell Smoke Detector 11 SK-PHOTO Photoelectric 10/22/2014 In Service - 15 Years to 25 Years Gentex Horn 5 MHR 10/06/2003 Horn/Strobe 2 GXS-4-15/75WR 10/06/2003 Silent Knight Horn/Strobe 1 10/06/2003 Pull Station 4 PS-SATK Single Action 10/06/2003 SimplexGrinnell Page of 14 14 Inventory & Warranty Report Hue & Cry, Inc.Download Date: 08/16/2024 Horn 6 2901-9838 10/06/2003 Horn 2 4901-9817 10/06/2003 Horn 1 GX90-4 10/06/2003 Horn/Strobe 23 2901-9838 10/06/2003 Pull Station 7 596B Single Action 10/06/2003 Strobe 2 unknown 10/06/2003 Squre D Disconnect 2 20amp Breaker 10/06/2003 System sensor Horn/Strobe 10 SPScRl 10/06/2003 Wheelock Horn/Strobe 1 10/06/2003 Horn/Strobe 1 MT12/24 10/06/2003 In Service - 25 Years or Older Honeywell Control Panel 1 6820EVS Addressable 10/17/1995 Phone line 1 Communication Line 1 846-2370 10/17/1995 Phone line 2 Communication Line 1 846-1275 10/17/1995 Building: Sycamore Middle School Control Panel: 2 The Inventory & Warranty Report lists each of the devices and items that are included in your Inspection Report. A complete inventory count by device type and category is provided. Items installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together for easy reference. Type Qty Model #Description Install Date In Service - 25 Years or Older Honeywell Power Supply 2 5496 05/20/1975 Power Supply 1 EVS-50W 05/20/1975