HomeMy WebLinkAbout063-330-014 14809 Eagle Ridge 2025Site Address: Owner: Mailing: Owners Phone: Evaluator:for Hydrotec Tank Volume:Gals.24 Inches X Yes No Good X Fair Poor High X Normal Low X Good Fair Poor X Yes No N/A Scum:2 Inches Sludge:14+Inches Yes No X N/A Scum:0 Inches Sludge:12+Inches X Good Fair Poor N/A X Yes No Yes X No X Yes No X Yes No X Good Poor X Yes No Alarms: X Audible X Visual EC ETM HLA OVR Yes X No Hydraulic Load Test:Excellent Good Poor X Dry Ponding X N/A Yes X No Yes X No Yes X No Yes X No Yes X No Yes X No Comments and System Map on Back ]HS,I-STEP8/11 1500 Condition: Structural Condition: Access Risers: Liquid Operating Level: All Floats Operating? Tank was Cleaned: This tank needs to be pumped Tank Material:Concrete Pump, Vault & Filter Cleaned? Inlet Tee: Outlet Tee: Baffle Condition: Pumping Required: N/A 14809 Eagle Ridge Dr., Forest Ranch, CA 95942 S.T.E.P. System Eval. Date: Ellice Rodrick A. Sievers 530-592-6240 Down Slope Seepage: Saturated Field: # Occupants: Multiple Systems: Pump: N/APump:N/A Piezometers: FAILURE Not Applicable Running AMPS: Control Panel: Depth to Access Lid: HYDROTEC SOLUTIONS P.O. Box 7908, Chico, CA 95927 (530) 891-4420, FAX: (530) 891-4426 Residential Supplemental Treatment Onsite System Evaluation and Maintenance Report Same 4/29/25 N/A Date Tank (s) Previously Pumped: Type of Filter: N/A Running Voltage: Screen Bacteria Action: 121.7 Community 11.58 Marginal Graywater: Surfacing Effluent: Effluent Line D.Valve: Type of Absorption Field: Well on Property: Satisfactory SEPTIC TANK: ABSORPTION TRENCHES: Evaluator Signature Date: N m O I O ^ FENCE GATE >10' x ^ PANEL E A G HOUSE L E R I D G u E D R I V E 14809 Eagle Ridge Dr. COMMENTS / OBSERVATIONS Replaced the "On/Off" and "High Level" floats. We found no other problems at this time. community system. We found no problems at this time. This onsite wastewater treatment and disposal system evaluation report is a true and complete record of the onsite waste- water treatment and disposal system on the date of the evaluation. No warranty is given or implied regarding the remaining life of this system. This tank needs to be pumped. There is root intrusion where the riser meets the tank PARCEL ADDRESS: This septic tank pumps its effluent to a transport line that goes to the main, LOCATION OF SEPTIC TANK & ABSORPTION FIELD 4/29/25 I certify that this onsite wastewater treatment and disposal system evaluation report reflects conditions observed on the parcel (s) during the routine maintenance of the onsite wastewater treatment and disposal system. A. Sievers and riser should be resealed. The pump is making noises that indicate it should be replaced soon. DRIVEWAY HS,I-STEP8/11