HomeMy WebLinkAbout1) ADM25-0013 SCL0115C_CDs REV-B - 2025.04.24PROJECT DESCRIPTION CODE COMPLIANCE VICINITY MAPSHEET INDEX 1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Licensor: Sheet Title: Sheet Number: Jurisdiction: Issued For: B 04/24/2025 95%CDs FOR REVIEW WM A 04/08/2025 90%CDs FOR REVIEW KP/WM REV DATE DESCRIPTION BY Prepared For: Engineer: 2840 HOWE ROAD, SUITE E MARTINEZ, CA 94553 www. TheCBRGroup.com Site Name: T-Mobile ID: OROVILLE QUINCY HWY PG&E NORTH TOWER CONSTRUCTION FOR OFFICIAL USE ONLY SCL0115C Site Address: 2867 ORO QUINCY HWY PROJECT TEAM SITE TITLE SHEET T-1 ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 1)2022 CALIFORNIA BUILDING CODE (CBC) 2)2022 CALIFORNIA RESIDENTIAL CODE (CRC) 3)2022 CALIFORNIA HISTORICAL BUILDING CODE (CHBC) 4)2022 CALIFORNIA EXISTING BUILDING CODE (CEBC) 5)2022 CALIFORNIA GREEN BUILDINGS STANDARDS CODE (CGBSC) 6)2022 CALIFORNIA FIRE CODE (CFC) 7)2022 CALIFORNIA MECHANICAL CODE (CMC) 8)2022 CALIFORNIA PLUMBING CODE (CPC) 9)2022 CALIFORNIA ELECTRICAL CODE (CEC) 10)2022 CALIFORNIA ENERGY CODE (CEC) 11)2021 NFPA 101, LIFE SAFETY CODE 12)2022 NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE AS AMENDED BY CA 13)2022 NFPA 13, FIRE SPRINKLER CODE AS AMENDED BY CA 14)2023 NFPA 70, NATIONAL ELECTRICAL CODE 15)ASCE 7-16, STRUCTURAL MINIMUM DESIGN LOADS AND ASSOCIATED CRITERIA 16)ACI 318-19, CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 17)CAL-OSHA THE INSTALLATION AND OPERATION OF ANTENNAS AND ASSOCIATED EQUIPMENT AT AN EXISTING AT&T UNMANNED WIRELESS COMMUNICATIONS FACILITY. SCOPE OF WORK CONSISTS OF THE FOLLOWING: ANTENNA AREA: 1.INSTALL (N) 12-FT. TOP-HAT ASSEMBLY 2.INSTALL (6)(N) ANTENNAS 3.INSTALL (6)(N) RADIOS 4.INSTALL (3)(N) TMAS 5.INSTALL (24)(N) 7/8"∅ COAX CABLES 6.EXTEND PG&E LADDER ON TOWER EQUIPMENT AREA: 7.INSTALL (1)(N) CHAIN-LINK FENCE ENCLOSURE ON (N) CONCRETE SLAB 8.INSTALL (1)(N) 6160 CABINET 9.INSTALL (2)(N) BASEBANDS INSIDE 6160 CABINET 10.INSTALL (1)(N) B160 CABINET 11.INSTALL (1)(N) IXRE ROUTER 12.INSTALL (2)(N) HYBRID CABLE SYSTEM (HCS) 13.INSTALL (1)(N) HCS WINDER BOX, (1)(N) 200A METER PANEL, (1) 200A PPC CABINET WITH (1)(N) CAM-LOCK BOX 14.INSTALL (1)(N) LED SERVICE LIGHT, (1)(N) GPS ANTENNA, (1)(N) CIENA BOX WITH (1)(N) FIBER BOX, AND (1)(N) FIRE EXTINGUISHER WITH CABINET 15.INSTALL (2)(N) H-FRAMES AND (1)(N) CONCRETE SLAB PROPERTY AREA 16.PROVIDE (N) TRENCHING FROM POC TO METER 17.INSTALL GRAVEL FIREBREAK INCLUDING FELT DEBRIS BARRIER 18.WEED ABATEMENT DOWN TO BARE EARTH PROPERTY OWNER: PACIFIC GAS AND ELECTRIC COMPANY 245 MARKET STREET, N10D SAN FRANCISCO, CA 94105 APN: 068-160-128 JEANNE M MARTIN TRUST 93 SADDLEBACK ROAD, ROLLING HILLS, CA 90274 CURRENT USE: UNMANNED TELECOMMUNICATIONS FACILITY PROPOSED USE: UNMANNED TELECOMMUNICATIONS FACILITY APN: 068-150-051 POWER AGENCY: PG&E 245 MARKET STREET SAN FRANCISCO, CA 94105 TELEPHONE AGENCY: AT&T CALIFORNIA 5001 EXECUTIVE PARKWAY SAN RAMON, CA 94583 COORDINATES (LAT/LONG): 39.506861° (39° 30' 24.70" NORTH) / -121.502292° (121° 30' 08.25" WEST) JURISDICTION: BUTTE COUNTY STRUCTURE TYPE: PG&E UTILITY LATTICE TOWER GROUND ELEVATION: ±540' AMSL PROJECT INFORMATION 04/09/2025 RADIO FREQUENCY DATA PLAN VERSION 1 REVISION LEVEL DATE: GENERAL CONTRACTOR NOTES CALL 811 B E F ORE YO U D I GSA FE DIGGING P A R TNERR DO NOT SCALE DRAWINGS THESE DRAWINGS ARE FORMATTED TO BE FULL SIZE AT 24" x 36". CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOBSITE AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT/ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR MATERIAL ORDERS OR BE RESPONSIBLE FOR THE SAME. OCCUPANCY AND CONSTRUCTION TYPE APPLICANT/LESSEE: T-MOBILE 1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 JAROD SPARROWK PH: (209) 247-6526 AGENT/ENGINEER: THE CBR GROUP 2840 HOWE ROAD, SUITE E MARTINEZ, CA 94553 S. WILSON PH: (925) 246-3212 EMAIL: projects@thecbrgroup.com PROJECT TYPE: COVERAGE STRATEGY OROVILLE QUINCY HWY PG&E NORTH TOWER SITE ID: SCL0115C TOWER: #27/121 SAP: #40590733 LINE NAME: VACA-LAKEVIEW-230KV 480' NORTH OF 2867 OROVILLE QUINCY HIGHWAY OROVILLE, CA 95966 STRUCTURE PHOTO ACCESSIBILITY REQUIREMENTS FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION, ACCESSIBILITY ACCESS AND REQUIREMENTS ARE NOT REQUIRED, IN ACCORDANCE WITH CALIFORNIA STATE ADMINISTRATIVE CODE, PART 2, TITLE 24, SECTION 1103B.1, EXCEPTION 1 & SECTION 1134B.2.1, EXCEPTION 4. OCCUPANCY : U (UNMANNED COMMUNICATIONS FACILITY) CONSTRUCTION TYPE: NOT APPLICABLE A-1 OVERALL SITE PLAN A-2 EXISTING AND PROPOSED ANTENNA AND EQUIPMENT PLANS A-3 A-4 DETAILSA-6 GN-1 GENERAL NOTES GN-2 GENERAL NOTES GN-3 SITE SIGNAGE ANTENNA AND EQUIPMENT SCHEDULEA-5 A-2.1 EXISTING AND PROPOSED EQUIPMENT PLANS T-1 TITLE SHEET EXISTING AND PROPOSED ELEVATIONS (SOUTH) EXISTING AND PROPOSED ELEVATIONS (EAST) GN-4 BATTERY SPECIFICATIONS E-3 ELETRICAL DETAILS DETAILSA-6.1 E-1 ELECTRICAL NOTES, PROPOSED GROUNDING PLAN/S E-2 SINGLE LINE DIAGRAM, AND PANEL SCHEDULE LS-1 SITE SURVEY EXHIBIT E-3.1 ELETRICAL DETAILS C:\Users\Wing Mok\Box\CBR General\T-MOBILE\T-Mobile Sites\SCL0115C\04 A&E\06 CAD\SCL0115C_T-1.dwg, 4/24/2025 11:15:01 AM GENERAL CONSTRUCTION NOTES 1.ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE LOCAL BUILDING CODE, THE LATEST EDIT AND ALL OTHER APPLICABLE CODES AND ORDINATES. 2.CONTRACTOR SHALL VISIT THE JOB SITE TO BECOME FAMILIAR HIMSELF WITH ALL CONDITIONS AFFECTING THE PROPOSED WORK AND SHALL MAKE PROVISIONS AS TO THE COST THEREOF. CONTRACTOR SHALL ALSO BE RESPONSIBLE TO BECOME FAMILIAR WITH THE CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO ATTENTION OF THE ENGINEER OF RECORD PRIOR TO THE COMMENCEMENT OF WORK. NO COMPENSATION WILL BE AWARDED BASED ON CLAIM OF LACK OF THE KNOWLEDGE OF THE FIELD CONDITIONS. 3.PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY UNLESS OTHERWISE NOTED. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT AND APPURTENANCES, AND LABOR NECESSARY TO EFFECT ALL INSTALLATION AS INDICATED ON THE DRAWINGS. 4.DIMENSIONS SHOWN ARE TO BE FINISH SURFACED UNLESS OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT IS REQUIRED CLEARANCE. THEREFORE, IT IS CRITICAL TO FIELD VERIFY DIMENSIONS, SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, EXISTING CONDITIONS AND/OR DESIGN INTENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING THE WORK. 5.DETAILS ARE INTENDED TO SHOW DESIGN INTENT. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK 6.CONTRACTOR SHALL RECEIVE CLARIFICATION IN WRITING, AND SHALL RECEIVE IN WRITING AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEMS NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACTOR DOCUMENTS. 7.CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING THE BEST CONSTRUCTION SKILLS AND ATTENTION. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER CONTRACT, UNLESS OTHERWISE NOTED. 8.CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE WORK AREA, ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BE AFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TO ALL OSHA REQUIREMENTS. 9.CONTRACTOR SHALL COORDINATE HIS WORK WITH THE SUPERINTENDENT OF BUILDINGS & GROUNDS AND SCHEDULE HIS ACTIVITIES AND WORKING HOURS IN ACCORDANCE WITH THE REQUIREMENTS. 10.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THIER WORK WITH THE WORK OF OTHERS AS IT MAY RELATE TO RADIO EQUIPMENT, ANTENNAS AND ANY OTHER PORTION OF THE WORK. 11.INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS UNLESS SPECIFICALLY OTHERWISE INDICATED OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 12.MAKE NECESSARY PROVISIONS TO PROTECT EXISTING SURFACES, EQUIPMENT, IMPROVEMENTS PIPING ETC. AND IMMEDIATELY REPAIR ANY DAMAGE THAT OCCURS DURING CONSTRUCTION. 13.IN DRILLING HOLES INTO CONCRETE WHETHER FOR FASTENING OR ANCHORING PURPOSED, OR PENETRATIONS THROUGH THE FLOOR FOR CONDUIT RUNS, PIPE RUNS, ETC., MUST BE CLEARLY UNDERSTOOD THAT REINFORCING STEEL SHALL NOT BE DRILLED INTO, CUT OR DAMAGED UNDER ANY CIRCUMSTANCES (UNLESS NOTED OTHERWISE). LOCATIONS OF REINFORCING STEEL ARE NOT DEFINITELY KNOWN AND THEREFORE MUST BE SEARCHED FOR BY APPROPRIATE METHODS AND EQUIPMENT 14.REPAIR ALL EXISTING WALL SURFACES DAMAGED DURING CONSTRUCTION SUCH THAT THEY MATCH AND BLEND IN WITH ADJACENT SURFACES. 15.SEAL PENETRATIONS THROUGH FIRE RATED AREA WITH U.L. LIST AND FIRE CODE APPROVED MATERIALS. 16.KEEP CONTRACT AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, AND RUBBISH, EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OF THE OWNER SHALL BE REMOVED. LEAVE PREMISE IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ALL ITEMS UNTIL COMPLETION OF CONSTRUCTION. 17.MINIMUM BEND RADIUS OF ANTENNA CABLES SHALL BE IN ACCORDANCE WITH CABLE MANUFACTURERS RECOMMENDATIONS. 18.ALL EXISTING INACTIVE SEWER, WATER, GAS ELECTRIC, AND OTHER UTILITY, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO APPLICABLE REGULATORY AUTHORITIES. 19.CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION SHALL BE IN CONFORMANCE WITH JURISDICTION OR STATE AND LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL AND COORDINATE WITH LOCAL REGULATORY AUTHORITIES. 20.ALL CONSTRUCTION IS TO ADHERE TO CLIENT (WIRELESS CARRIER) INTEGRATED CONSTRUCTION STANDARDS UNLESS CALIFORNIA CODE IS MORE STRINGENT. 21.THE INTENT OF THE PLANS AND SPECIFICATIONS TO PERFORM THE CONSTRUCTION IN ACCORDANCE WITH THE CALIFORNIA BUILDING STANDARDS CODE, TITLES 19 AND 24, CALIFORNIA CODE OF REGULATIONS SHALL ANY CONDITIONS DEVELOP NOT COVERED BY THE APPROVED PLANS AND SPECIFICATIONS WHEREIN THE FINISHED WORK WILL NOT COMPLY WITH TITLE 24, CALIFORNIA CODE OF REGULATIONS, A CHANGE ORDER DETAILING AND SPECIFYING THE REQUIRED WORK SHALL BE SUBMITTED TO AND APPROVED BY THE JURISDICTION BEFORE PROCEEDING WITH THE WORK. SITE WORK NOTES 1.DO NOT EXCAVATE OR DISTURB THE PROPERTY LINES OR LEASE LINES, UNLESS OTHERWISE NOTED. 2.DO NOT SCALE BUILDING DIMENSIONS FROM DRAWING. 3.SIZE, LOCATION AND TYPE OF ANY UNDERGROUND UTILITIES OR IMPROVEMENTS SHALL BE ACCURATELY NOTED AND PLACED ON AS-BUILT DRAWINGS BY GENERAL CONTRACTOR AND ISSUED TO ARCHITECT/ENGINEER AT COMPLETION OF PROJECT. 4.ALL EXISTING UTILITIES, FACILITIES, CONDITIONS AND THEIR DIMENSIONS SHOWN ON PLANS HAVE BEEN PLOTTED FROM AVAILABLE RECORDS. THE ENGINEER AND OWNER ASSUME NO RESPONSIBILITY WHATSOEVER AS TO THE SUFFICIENCY OR ACCURACY OF THE INFORMATION SHOWN ON THE PLANS OR THE MANNER OF THEIR REMOVAL OR ADJUSTMENT. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING EXACT LOCATION OF ALL EXISTING UTILITIES AND FACILITIES PRIOR TO START OF CONSTRUCTION. CONTRACTOR SHALL ALSO OBTAIN FROM EACH UTILITY COMPANY DETAILED INFORMATION RELATIVE TO WORKING SCHEDULES AND METHODS OF REMOVING OR ADJUSTING EXISTING UTILITIES. 5.CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES BOTH HORIZONTALLY AND VERTICALLY PRIOR TO START OF CONSTRUCTION. ANY DISCREPANCIES OR DOUBTS AS TO THE INTERPRETATION OF PLANS SHALL BE IMMEDIATELY REPORTED TO THE ARCHITECT/ENGINEER FOR SOLUTION AND INSTRUCTION, AND NO FURTHER WORK SHALL BE PERFORMED UNTIL THE DISCREPANCY IS CHECKED AND CORRECTED BY THE ARCHITECT/ENGINEER. FAILURE TO SECURE SUCH AS INSTRUCTION MEANS CONTRACTOR WILL HAVE WORKED AT HIS/HER OWN RISK AND EXPENSE. CONTRACTOR SHALL CALL LOCAL DIGGER HOT LINE FOR UTILITY LOCATIONS 48 HOURS PRIOR TO CONSTRUCTION. 6.ALL NEW AND EXISTING UTILITY STRUCTURES ON SITE AND IN AREAS TO BE DISTURBED BY CONSTRUCTION SHALL BE ADJUSTED TO FINISH ELEVATIONS PRIOR TO FINAL INSPECTION OF WORK. 7.GRADING OF THE SITE WORK AREA IS TO BE SMOOTH AND CONTINUOUS IN SLOPE AND IS TO FEATHER INTO EXISTING GRADES AT THE GRADING LIMITS. 8.ALL TEMPORARY EXCAVATIONS FOR THE INSTALLATION OF FOUNDATIONS, UTILITIES, ETC. SHALL BE PROPERLY LAID BACK OR BRACED IN ACCORDANCE WITH CORRECT OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) REQUIREMENTS. 9.STRUCTURAL FILLS SUPPORTING PAVEMENT SHALL BE COMPACTED TO 95% OF MAXIMUM STANDARD PROCTOR DRY DENSITY. 10.NEW GRADES NOT IN BUILDING AND DRIVEWAY IMPROVEMENT AREA TO BE ACHIEVED BY FILLING WITH APPROVED CLEAN FILL AND COMPACTED TO 95% OF STANDARD PROCTOR DENSITY. 11.ALL FILLS SHALL BE PLACED IN UNIFORM LIFTS. THE LIFTS THICKNESS SHOULD NOT EXCEED THAT WHICH CAN BE PROPERLY COMPACTED THROUGHOUT ITS ENTIRE DEPTH WITH THE EQUIPMENT AVAILABLE. 12.ALL FILLS PLACED ON EXISTING SLOPES THAT ARE STEEPER THAN 10 HORIZONTAL TO 1 VERTICAL SHALL BE PROPERLY BENCHED INTO THE EXISTING SLOPE AS DIRECTED BY A GEO-TECHNICAL ENGINEER. 13.CONTRACTOR SHALL CLEAN ENTIRE SITE AFTER CONSTRUCTION SUCH THAT NO PAPERS, TRASH, WEEDS, BRUSHES OR ANY OTHER DEPOSITS WILL REMAIN. ALL MATERIALS COLLECTED DURING CLEANING OPERATIONS SHALL BE DISPOSED OF OFF-SITE BY THE GENERAL CONTRACTOR. 14.ALL TREES AND SHRUBS WHICH ARE NOT IN DIRECT CONFLICT WITH THE IMPROVEMENTS SHALL BE PROTECTED BY THE GENERAL CONTRACTOR. 15.ALL SITE WORK SHALL BE CAREFULLY COORDINATED BY GENERAL CONTRACTOR WITH LOCAL UTILITY COMPANY, TELEPHONE COMPANY, AND OTHER UTILITY COMPANIES HAVING JURISDICTION OVER THIS LOCATION. ENVIRONMENTAL NOTES 1.ALL WORK PERFORMED SHALL BE DONE IN ACCORDANCE WITH ISSUED PERMITS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PAYMENT OF FINES AND PROPER CLEAN UP FOR AREAS IN VIOLATION. 2.CONTRACTOR AND/OR DEVELOPER SHALL BE RESPONSIBLE FOR CONSTRUCTION AND MAINTENANCE OF EROSION AND SEDIMENTATION CONTROLS DURING CONSTRUCTION FOR PROTECTION OF ADJACENT PROPERTIES, ROADWAYS AND WATERWAYS AND SHALL BE MAINTAINED IN PLACE THROUGH FINAL JURISDICTIONAL INSPECTION & RELEASE OF SITE. 3.CONTRACTOR SHALL INSTALL/CONSTRUCT ALL NECESSARY SEDIMENT/SILT CONTROL FENCING AND PROTECTIVE MEASURES WITHIN THE LIMITS OF SITE DISTURBANCE PRIOR TO CONSTRUCTION. 4.NO SEDIMENT SHALL BE ALLOWED TO EXIT THE PROPERTY. THE CONTRACTOR IS RESPONSIBLE FOR TAKING ADEQUATE MEASURED FOR CONTROLLING EROSION. ADDITIONAL SEDIMENT CONTROL FENCING MAY BE REQUIRED IN ANY AREAS SUBJECT TO EROSION. 5.THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING POSITIVE DRAINAGE ON THE SITE AT ALL TIMES WITH SILT AND EROSION CONTROL MEASURES MAINTAINED ON THE DOWNSTREAM SIDE OF SITE DRAINAGE. ANY DAMAGE TO ADJACENT PROPERTY AS A RESULT OF EROSION WILL BE CORRECTED AT THE CONTRACTOR EXPENSE. 6.CONTRACTOR SHALL BE RESPONSIBLE FOR DAILY INSPECTIONS AND ANY REPAIRS OF ALL SEDIMENT CONTROL MEASURES INCLUDING SEDIMENT REMOVAL AS NECESSARY. 7.CLEANING OF VEGETATION AND TREE REMOVAL SHALL BE ONLY AS PERMITTED AND BE HELD TO A MINIMUM. ONLY TREES NECESSARY FOR CONSTRUCTION OF THE FACILITIES SHALL BE REMOVED. 8.SEEDING AND MULCHING AND/OR SODDING OF THE SITE WILL BE ACCOMPLISHED AS SOON AS POSSIBLE AFTER COMPLETION OF THE PROJECT FACILITIES AFFECTING LAND DISTURBANCE. 9.CONTRACTOR SHALL PROVIDE ALL EROSION AND SEDIMENTATION CONTROL MEASURES AS REQUIRED BY LOCAL, COUNTY AND STATE CODES AND ORDINANCES TO PROTECT EMBANKMENTS FROM SOIL LOSS AND PREVENT ACCUMULATION OF SOIL AND SILT IN STREAMS AND DRAINAGE PATHS LEAVING THE CONSTRUCTION AREA. THIS MAY INCLUDE SUCH MEASURES AS SILK FENCES, STRAW BALE SEDIMENT BARRIERS, AND CHECK DAMS. 10.RIP RAP OF SIZES INDICATED SHALL CONSIST OF CLEAN, HARD, SOUND, DURABLE, UNIFORM IN QUALITY STONE FREE OF ANY DETRIMENTAL QUANTITY OF SOFT, FRIABLE, THIN, ELONGATED OR LAMINATED PIECES, DISINTEGRATED MATERIAL, ORGANIC MATTER, OIL, ALKALI, OR OTHER DELETERIOUS SUBSTANCES. ROOF & WATERPROOFING NOTES: 1.CONTRACTOR SHALL CONTACT THE BUILDING OWNER TO DETERMINE IF ROOF IS UNDER WARRANTY. CONTRACTOR SHALL GUARANTEE THAT ANY AND ALL NEW ROOFING WORK MEETS THE SPECIFICATION OF ANY EXISTING ROOFING WARRANTIES SUCH THAT THE WARRANTY IS NOT MADE INVALID AS A RESULT OF THIS WORK. IF IT IS DETERMINED THAT THE ARCHITECT'S DETAILING IS INADEQUATE OR IMPROPER OR IF ANY OTHER DISCRPANCY IS FOUND, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT AND THE CLIENT PROJECT MANAGER IN WRITING. ULTIMATELY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH THE ORIGINAL ROOF MANUFACTURER'S SPECIFICATIONS. 2.CONTRACTOR SHALL USE METHODS AND MATERIALS SIMILAR AND COMPATIBLE WITH EXISTING MATERIALS AND CONDITIONS FOR ROOF PATCHING, NEW PENETRATIONS, ETC. 3.THE CONTRACTOR SHALL PROPERLY SEAL ALL NEW ROOF AND BUILDING ENVELOPE PENETRATIONS SUCH THAT THE INTEGRITY OF THE ORIGINAL BUILDING ASSEMBLY AND ALL APPLICABLE WARRANTIES ARE MAINTAINED. 4.IF DEEMED NECESSARY TO REMOVE EXISTING FINISHED AND/OR MATERIALS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECONSTRUCTING FINISHES AND MATERIALS TO LIKE-NEW CONDITIONS. CONTRACTOR SHALL MAINTAIN THE ORIGINAL COLORS, TEXTURES AND FINISHES UNLESS SPECIFICALLY NOTED TO THE CONTRARY OR APPROVED BY CLIENT CONSTRUCTION MANAGER IN ADVANCE. 5.AT THE CLIENT CONSTRUCTION MANAGER'S DISCRETION, THE CONTRACTOR SHALL PROVIDE ROOFTOP WALKPADS TO ALL NEW EQUIPMENT. ON CONVENTIONAL ROOFING, THE WALKPADS SHALL BE "DUCK BOARDS" AS MANUFACTURED BY 'APC' OR EQUAL. ON SPECIAL ROOFINT SYSTEMS SUCH AS SINGLE MEMBRANE, ROOFS WILL REQUIRE A SPECIFIC PRODUCT AS NOTED ON PLANS OR AS REQUIRED BY NOTES #1 & #2 ABOVE. PENETRATION AT FIRE-RATED ASSEMBLIES NOTES: 1.AT THE CLIENT PROJECT MANAGER'S DIRECTION, THE CONTRACTOR SHALL PROVIDE "HILTI" HIGH PERFORMANCE FIRESTOP SYSTEM #FS601 AT ALL FIRE-RATED PENETRATIONS INSTALLED PER MANUFACTURER'S LATEST INSTALLATION SPECIFICATIONS. 2.ALL PENETRATIONS THROUGH FIRE-RATED ASSEMBLIES SHALL BE CONSTRUCTED SO AS TO MAINTAIN AN EQUAL OR GREATER FIRE-RATING. PAINTING NOTES: 1.ALL PAINT PRODUCT LINE SHALL BE "SHERWIN-WILLIAMS" OR EQUAL UNLESS SPECIFICALLY NOTED OTHERWISE. 2.CONTRACTOR SHALL PREPARE ALL SURFACES AND APPLY ALL FINISHES PER LATEST EDITION OF MANUFACTURER'S SPECIFICATIONS. 3.FINISH COLOR AND TEXTURE OF ALL SURFACES TO BE PAINTED SHALL MATCH ADJACENT SURFACES UNLESS NOTED OTHERWISE. 4.ALL PAINT MATERIAL DATA SHEET SHALL BE PROVIDED TO THE CELL CARRIER CONSTRUCTION MANAGER. 5.CONTRACTOR SHALL CORRECT RUNS, SAGS, MISSES, AND OTHER DEFECTS INCLUDING INADEQUATE COVERAGE AS DIRECTED BY THE CLIENT CONSTRUCTION MANAGER. REPAINT AS NECESSARY TO ACHIEVE SURFACES WHICH ARE SMOOTH, EVENLY COATED WITH UNIFORM SHEEN AND FREE FROM BLEMISHES. 1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Licensor: Sheet Title: Sheet Number: Jurisdiction: Issued For: B 04/24/2025 95%CDs FOR REVIEW WM A 04/08/2025 90%CDs FOR REVIEW KP/WM REV DATE DESCRIPTION BY Prepared For: Engineer: 2840 HOWE ROAD, SUITE E MARTINEZ, CA 94553 www. TheCBRGroup.com Site Name: T-Mobile ID: OROVILLE QUINCY HWY PG&E NORTH TOWER CONSTRUCTION FOR OFFICIAL USE ONLY SCL0115C Site Address: 2867 ORO QUINCY HWY GENERAL NOTES GN-1 C:\Users\Wing Mok\Box\CBR General\T-MOBILE\T-Mobile Sites\SCL0115C\04 A&E\06 CAD\SCL0115C_GN-1.dwg, 4/24/2025 11:15:05 AM 1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Licensor: Sheet Title: Sheet Number: Jurisdiction: Issued For: B 04/24/2025 95%CDs FOR REVIEW WM A 04/08/2025 90%CDs FOR REVIEW KP/WM REV DATE DESCRIPTION BY Prepared For: Engineer: 2840 HOWE ROAD, SUITE E MARTINEZ, CA 94553 www. TheCBRGroup.com Site Name: T-Mobile ID: OROVILLE QUINCY HWY PG&E NORTH TOWER CONSTRUCTION FOR OFFICIAL USE ONLY SCL0115C Site Address: 2867 ORO QUINCY HWY GENERAL NOTES GN-2 STRUCTURAL STEEL 1.ALL STEEL WORK SHALL BE IN ACCORDANCE WITH STEEL CONSTRUCTION MANUAL, 15th EDITION AND ALL EXTERIOR EXPOSED STEEL AND HARDWARE SHALL BE HOT-DIPPED GALVANIZED. FILL MODIFICATIONS ARE TO BE COATED WITH ZINC-ENRICHED PAINT. 2.STEEL SECTIONS SHALL BE IN ACCORDANCE WITH THE FOLLOWING ASTM STANDARDS: -ANGLE, BARS, AND CHANNELS: ASTM A36, 36 KSI -W-SHAPES: ASTM 1992, 50 KSI -HSS SECTOR: ASTM A53-E, 35 KSI 3.ALL WELDING SHALL BE PERFORMED USING E70 (LOW HYDROGEN) ELECTRODES BY AWS CERTIFIED WELDERS. WELDING SHALL CONFORM TO AISC AND THE LATEST EDITION OF AWS D1.1. WHERE FILLET WELD SIZES ARE NOT SHOWN, PROVIDE THE MINIMUM SIZE PER TABLE J2.4 IN THE AISC "MANUAL OF STEEL CONSTRUCTION". PAINTED SURFACES SHALL BE TOUCHED UP. 4.NON-STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8" DIA. ASTM A307 BOLTS UNLESS NOTED OTHERWISE. BOLTED CONNECTIONS SHALL BE ASTM A325 BEARING TYP. 3/4" DIA. CONNECTIONS AND SHALL HAVE MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE. 5.CONTRACTOR SHALL COLD-GALVANIZE ALL RAW STEEL AS REQUIRED DURING CONSTRUCTION PROCESS. CONCRETE AND REINFORCEMENT STEEL 1.ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 318-16, ACI 301-16 AND THE CAST-IN-PLACE CONCRETE SPECIFICATIONS. 2.ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2,500 PSI AT 28 DAYS UNLESS NOTED OTHERWISE. 3.WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 WELDED STEEL WIRE FABRIC UNLESS NOTED OTHERWISE 4.REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, UNLESS NOTED OTHERWISE. 5.SPLICES CLASS "B" AND ALL HOOKS SHALL BE STANDARD UNLESS NOTED OTHERWISE. 6.A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE UNLESS NOTED OTHERWISE IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. 7.CONCRETE COVER FOR REINFORCEMENT STEEL SHALL BE ACCORDING TO ACI 318-19, TABLE 20.6.1.3.1: CONCRETE MASONRY 1.MORTAR SHALL BE HAVE TYPE "S" WITH A MINIMUM 1,800 PSI AT 28 DAYS. GROUT SHALL BE A MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI AT 28 DAYS AND ALL GROUT SHALL BE CONSOLIDATED WITH A MECHANICAL VIBRATOR. 2.CONCRETE MASONRY UNITS SHALL BE MEDIUM WEIGHT (115 PCF) UNITS CONFORMS TO ASTM C90, GRADE N-1, f'M OF 1,500 PSI. 3.ALL CELLS IN CONCRETE BLOCKS SHALL BE FILLED SOLID WITH GROUT, EXCEPT AS NOTED IN THE DRAWINGS OR SPECIFICATIONS. CELL SHALL BE IN VERTICAL ALIGNMENT. DOWELS IN FOOTINGS SHALL BE SET TO ALIGN WITH CORES CONTAINING STEEL. ALL BOND BEAM BLOCK SHALL BE "DEEP CUT" UNITS. 4.ALL CELLS CONTAINING REINFORCING STEEL OR EMBEDDED ITEMS AND ALL CELLS IN RETAINING WALLS AND WALLS BELOW GRADE SHALL BE SOLID GROUTED. ALL HORIZONTAL REINFORCING STEEL SHALL BE PLACED IN BOND OR LINTEL BEAM UNITS. 5.WHEN GROUTING IS STOPPED FOR ONE LONGER, HORIZONTAL CONSTRUCTION JOINTS SHALL BE FORMED BY STOPPING THE GROUT POUR 1-1/2" BELOW TOP OF THE UPPERMOST UNIT. LOW LIFT CONSTRUCTION, MAXIMUM GROUT POUR HEIGHT IS 4 FEET. 6.PROVIDE INSPECTION AND CLEAN OUT HOLES AT BASE OF VERTICAL CELLS HAVING GROUT LIFTS IN EXCESS OF 4'-0" OF HEIGHT. 7.PROVIDE ONE BAR DIAMETER (A MINIMUM OF 1/2") GROUT BETWEEN MAIN REINFORCING AND MASONRY UNITS. 8.SAND SHALL BE CLEAN, SHARP AND WELL GRADED, AND FREE FROM INJURIOUS AMOUNTS OF DUST, LUMPS, SHALE, ALKAU OR ORGANIC MATERIAL. 9.BRICK SHALL CONFORM TO ASTM C-62 AND SHALL BE GRADE MW OR BETTER. CONCRETE EXPOSURE MEMBER REINFORCEMENT SPECIFIED COVER, IN. CAST AGAINST AND PERMANENTLY IN CONTACT WITH GROUND ALL ALL 3 EXPOSED TO WETHER OR IN CONTACT WITH GROUND ALL NO.6 THROUGH NO.18 BARS 2 NO. 5 BAR, W31 OR D31 WIRE, AND SMALLER 1-1/2 NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND SLABS, JOISTS, AND WALLS NO. 14 AND NO.18 BARS 1-1/2 NO.11 BAR AND SMALLER 3/4 BEAMS, COLUMNS PEDESTALS, AND TENSION TIES PRIMARY REINFORCEMENT, STIRRUPS, TIES, SPIRALS, AND HOOPS 1-1/2 PAINTING NOTES: 1.ALL PAINT PRODUCT LINE SHALL BE "SHERWIN-WILLIAMS" OR EQUAL UNLESS SPECIFICALLY NOTED OTHERWISE. 2.CONTRACTOR SHALL PREPARE ALL SURFACES AND APPLY ALL FINISHES PER LATEST EDITION OF MANUFACTURER'S SPECIFICATIONS. 3.FINISH COLOR AND TEXTURE OF ALL SURFACES TO BE PAINTED SHALL MATCH ADJACENT SURFACES UNLESS NOTED OTHERWISE. 4.ALL PAINT MATERIAL DATA SHEET SHALL BE PROVIDED TO THE CELL CARRIER CONSTRUCTION MANAGER. 5.CONTRACTOR SHALL CORRECT RUNS, SAGS, MISSES, AND OTHER DEFECTS INCLUDING INADEQUATE COVERAGE AS DIRECTED BY THE T-MOBILE CONSTRUCTION MANAGER. REPAINT AS NECESSARY TO ACHIEVE SURFACES WHICH ARE SMOOTH, EVENLY COATED WITH UNIFORM SHEEN AND FREE FROM BLEMISHES. ROOF & WATERPROOFING NOTES: 1.CONTRACTOR SHALL CONTACT THE BUILDING OWNER TO DETERMINE IF ROOF IS UNDER WARRANTY. CONTRACTOR SHALL GUARANTEE THAT ANY AND ALL NEW ROOFING WORK MEETS THE SPECIFICATION OF ANY EXISTING ROOFING WARRANTIES SUCH THAT THE WARRANTY IS NOT MADE INVALID AS A RESULT OF THIS WORK. IF IT IS DETERMINED THAT THE ARCHITECT'S DETAILING IS INADEQUATE OR IMPROPER OR IF ANY OTHER DISCRPANCY IS FOUND, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT AND THE CLIENT PROJECT MANAGER IN WRITING. ULTIMATELY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH THE ORIGINAL ROOF MANUFACTURER'S SPECIFICATIONS. 2.CONTRACTOR SHALL USE METHODS AND MATERIALS SIMILAR AND COMPATIBLE WITH EXISTING MATERIALS AND CONDITIONS FOR ROOF PATCHING, NEW PENETRATIONS, ETC. 3.THE CONTRACTOR SHALL PROPERLY SEAL ALL NEW ROOF AND BUILDING ENVELOPE PENETRATIONS SUCH THAT THE INTEGRITY OF THE ORIGINAL BUILDING ASSEMBLY AND ALL APPLICABLE WARRANTIES ARE MAINTAINED. 4.IF DEEMED NECESSARY TO REMOVE EXISTING FINISHED AND/OR MATERIALS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECONSTRUCTING FINISHES AND MATERIALS TO LIKE-NEW CONDITIONS. CONTRACTOR SHALL MAINTAIN THE ORIGINAL COLORS, TEXTURES AND FINISHES UNLESS SPECIFICALLY NOTED TO THE CONTRARY OR APPROVED BY T-MOBILE CONSTRUCTION MANAGER IN ADVANCE. 5.AT THE CLIENT CONSTRUCTION MANAGER'S DISCRETION, THE CONTRACTOR SHALL PROVIDE ROOFTOP WALKPADS TO ALL NEW EQUIPMENT. ON CONVENTIONAL ROOFING, THE WALKPADS SHALL BE "DUCK BOARDS" AS MANUFACTURED BY 'APC' OR EQUAL. ON SPECIAL ROOFINT SYSTEMS SUCH AS SINGLE MEMBRANE, ROOFS WILL REQUIRE A SPECIFIC PRODUCT AS NOTED ON PLANS OR AS REQUIRED BY NOTES #1 & #2 ABOVE. PENETRATION AT FIRE-RATED ASSEMBLIES NOTES: 1.AT THE CLIENT PROJECT MANAGER'S DIRECTION, THE CONTRACTOR SHALL PROVIDE "HILTI" HIGH PERFORMANCE FIRESTOP SYSTEM #FS601 AT ALL FIRE-RATED PENETRATIONS INSTALLED PER MANUFACTURER'S LATEST INSTALLATION SPECIFICATIONS. 2.ALL PENETRATIONS THROUGH FIRE-RATED ASSEMBLIES SHALL BE CONSTRUCTED SO AS TO MAINTAIN AN EQUAL OR GREATER FIRE-RATING. GENERAL NOTES GN-2 C:\Users\Wing Mok\Box\CBR General\T-MOBILE\T-Mobile Sites\SCL0115C\04 A&E\06 CAD\SCL0115C_GN-1.dwg, 4/24/2025 11:15:06 AM NOTES: 1. CONTRACTOR SHALL INSTALL ALL INFORMATION SIGNAGE IN ACCORDANCE WITH T-MOBILE DOCUMENT #03-0074, RF EXPOSURE POLICY AND RF SAFETY COMPLIANCE PROGRAM, LATEST EDITION. 2. CONTRACTOR SHALL CONTACT T-MOBILE R-RFSC FOR INFORMATION ON MPE LEVELS AND INSTRUCTIONS ON LEVEL AND LOCATION OF SIGNAGE SIGNAGE AND STRIPING INFORMATION 1.THE FOLLOWING INFORMATION IS A GUIDELINE WITH RESPECT TO PREVAILING STANDARDS LIMITING HUMAN EXPOSURE TO RADIO FREQUENCY ENERGY AND SHOULD BE USED AS SUCH. IF THE SITE'S EME REPORT OR ANY LOCAL, STATE OR FEDERAL GUIDELINES OR REGULATIONS SHOULD BE IN CONFLICT WITH ANY PART OF THESE NOTES OR PLANS, THE MORE RESTRICTIVE GUIDELINE OR REGULATION SHALL BE FOLLOWED AND OVERRIDE THE LESSER. 2.THE PUBLIC LIMIT OF RF EXPOSURE ALLOWED BY T-MOBILE IS 1mWcm*2 AND THE OCCUPATIONAL LIMIT OF RF EXPOSURE ALLOWED BY T-MOBILE IS 5mWcm*2. 3.IF THE BOTTOM OF THE ANTENNA IS MOUNTED 8 FEET ABOVE THE GROUND OR WORKING PLATFORM LINE OF THE PERSONAL COMMUNICATION SYSTEM (PCS) AND DOES NOT EXCEED THE PUBLIC LIMIT OF RF EXPOSURE LIMIT THEN NO STRIPING OR BARRICADES SHOULD BE NEEDED. 4.IF THE PUBLIC LIMIT OF RF EXPOSURE ON THE SITE IS EXCEEDED AND THE AREA IS PUBLICLY ACCESSIBLE (E.G. ROOF ACCESS DOOR THAT CANNOT BE LOCKED, OR FIRE EGRESS) THEN BOTH BARRICADES AND STRIPING SHALL BE PLACED AROUND THE ANTENNAS. THE EXACT EXTENT OF THE BARRICADES AND STRIPING SHALL BE DETERMINED BY THE EME REPORT FOR THE SITE DONE BEFORE OR SHORTLY AFTER COMPLETION OF SITE CONSTRUCTION. USE THE PLANS AS A GUIDELINE FOR PLACEMENT OF SUCH BARRICADES AND STRIPING. 5.ALL TRANSMIT ANTENNAS REQUIRE A THREE LANGUAGE WARNING SIGN WRITTEN IN ENGLISH, SPANISH, AND CHINESE. THIS SIGN SHALL BE PROVIDED TO THE CONTRACTOR AND THE T-MOBILE CONSTRUCTION PROJECT MANAGER AT THE TIME OF CONSTRUCTION. THE LARGER SIGN SHALL BE PLACED IN PLAIN SIGHT AT ALL ROOF ACCESS LOCATIONS AND ON ALL BARRICADES. THE SMALLER SIGN SHALL BE PLACED ON THE ANTENNA ENCLOSURES IN A MANNER THAT IS EASILY SEEN BY ANY PERSON ON THE ROOF. WARNING SIGNS SHALL COMPLY WITH ANSI C95.2 COLOR, SYMBOL, AND CONTENT CONVENTIONS. ALL SIGNS SHALL HAVE T-MOBILE'S NAME AND THE COMPANY CONTACT INFORMATION (E.G. TELEPHONE NUMBER) TO ARRANGE FOR ACCESS TO THE RESTRICTED AREAS. THIS TELEPHONE NUMBER SHALL BE PROVIDED TO THE CONTRACTOR BY THE T-MOBILE CONSTRUCTION PROJECT MANAGER AT THE TIME OF CONSTRUCTION. 6.PHOTOS OF ALL STRIPING, BARRICADES AND SIGNAGE SHALL BE PART OF THE CONTRACTOR'S CLOSE-OUT PACKAGE AND SHALL BE TURNED INTO THE T-MOBILE CONSTRUCTION PACKAGE AND SHALL BE TURNED OVER TO THE T-MOBILE CONSTRUCTION PROJECT MANAGER AT THE END OF CONSTRUCTION. STRIPING SHALL BE DONE WITH FADE-RESISTANT YELLOW SAFETY PAINT IN A CROSS-HATCH PATTERN AS DETAILED BY THE CONSTRUCTION DRAWINGS. ALL BARRICADES SHALL BE MADE OF AN RF-FRIENDLY MATERIAL SO AS NOT TO BLOCK OR INTERFERE WITH THE OPERATION OF THE ANTENNAS. BARRICADES SHALL BE PAINTED WITH FADE-RESISTANT YELLOW SAFETY PAINT. THE CONTRACTOR SHALL PROVIDE ALL RF-FRIENDLY BARRICADES NEEDED, AND SHALL PROVIDE THE T-MOBILE CONSTRUCTION PROJECT MANAGER WITH A DETAILED SHOP DRAWING OF EACH BARRICADE UPON CONSTRUCTION COMPLETION. INFORMATION SIGN 1-3 N.T.S.C FRONT OF THE SIGN: ALL PAINT WILL BE BAKED WITH ENAMEL AND WITH UV-PROTECTIVE COATING OVER THE FACE OF THE SIGN. SIGN 1-2: POLE, SEE DETAIL B, THIS SHEET SIGN 1-2 MUST BE A NON-METALLIC LABEL WITH AN ADHESIVE BACKING, THE LABEL SHALL BE MADE USING VINYL OR SIMILAR WEATHERPROOF MATERIAL. THE LABEL SHALL BE APPROXIMATELY 5X7 INCHES WITH A WHITE BACKGROUND AND BLACK LETTERING. THE GREEN BAND SHALL BE 1.375 INCH IN HEIGHT & THE LETTERING SHALL BE BLACK WITH 0.75-INCH HIGH LETTERS. THE TEXT LETTERING SHALL BE BLACK WITH 1/8-INCH HIGH LETTERS. UV-PROTECTION SHALL BE PLACED OVER THE FRONT OF THE LABEL. SIGN 1-3: BACK OF ANTENNAS, SEE DETAIL C & 3, THIS SHEET SIGN 1-3 IS A 1-INCH X 2-INCH PANEL THAT CAN BE APPLIED TO THE BACK OR SIDE OF AN ANTENNA TO IDENTIFY IT AS AN T-MOBILE ANTENNA. SIGN 1-4: SIDE OF ANTENNAS, SEE DETAIL D & 3, THIS SHEET SIGN 1-4 IS MADE FROM TRANSPARENT MATERIAL 1-1/2-INCHES WIDE & 24-INCHES LONG. THE LETTERING IS TO BE BLACK WITH 1/2-INCH LETTERING IN A VERTICAL COLUMN. THE SPACING BETWEEN WORDS MUST BE SUCH THAT IT IS EASILY READ & FILLS THE LENGTH OF THE SIGN. INFORMATION SIGN 1-1 N.T.S.A INFORMATION SIGN 1-2 N.T.S.B INFORMATION SIGN 1-4 N.T.S.D Property of T-MOBILE Authorized Personnel Only No Trespassing Violators will be Prosecuted In case of emergency, or prior to performing maintenance on this site, call ____________________ and reference cell site number __________________ AUTHORIZED PERSONNEL ONLY NOTICE Property of T-MOBILE Authorized Personnel Only In case of emergency, or prior to performing maintenance on this site, call __________________ and reference cell site number _________________ INFORMATION Posted in accordance with federal Communications Commission rules and antenna tower registration 47CFR 17.4(g). 1 2 3 4 5 6 7 Federal Communications Communication Tower Registration Number 8"12" This Site Operated by: T-MOBILE 1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 IN CASE OF FIRE AND THE NEED FOR SHUTDOWN TO DEACTIVATE ANTENNAS CALL THE FOLLOWING NUMBER: For 24-Hour Emergency Contact and Access Please Call: (888) 662-4662 Reference Site#: ___________ Site Address: ______________________________________________ TRESPASSING NO DANGER INFORMATION T-MOBILE OPERATES TELECOMMUNICATION ANTENNAS AT THIS LOCATION. REMAIN AT LEAST 3 FEET AWAY FROM ANY ANTENNA AND OBEY ALL POSTED SIGNS. CONTACT THE OWNER(S) OF THE ANTENNA(S) BEFORE WORKING CLOSER THAN 3 FEET FROM THE ANTENNA(S). CONTACT T-MOBILE AT 888-662-4662 PRIOR TO PERFORMING ANY MAINTENANCE OR REPAIRS NEAR TMOBILE ANTENNAS. THIS IS SITE # _____________________ CONTACT THE MANAGEMENT OFFICE IF THIS DOOR/HATCH/GATE IS FOUND UNLOCKED. INFORMACION EN ESTA PROPIEDAD SE UBICAN ANTENAS DE TELECOMUNICACIONES OPERADAS POR T-MOBILE. FAVOR MANTENER UNA DISTANCIA DE NO MENOS DE 3 PIES Y OBEDECER TODOS LOS AVISOS. COMUNIQUESE CON EL PROPIETARIO O LOS PROPIETARIOS DE LAS ANTENAS ANTES DE TRABAJAR O CAMINAR DE MENOS DE 3 PIES DE LA ANTENA. COMUNIQUESE CON T MOBILE 888-662-4662 ANTES DE REALIZAR CUALQUIER MANTENIMIENTO O REPARACION DE LAS ANTENAS DE T-MOBILE. ESTA ES LA ESTACION BASE NUMERO ___________________________ FAVOR COMINUCARSE CON LA OFICINA DE LA ADMINISTRACION DEL EDIFICIO SI ESTA PUENTA O COMPUERTA SE ENCUENTRA SIN CANDADO.12"8" INFORMATION ACTIVE ANTENNAS ARE MOUNTED ON THE OUTSIDE FACE OF THIS BUILDING INFORMATION SIGN 1-2 ON THIS STRUCTURE STAY BACK A MINIMUM OF 3 FEETFROM THESE ANTENNAS CONTACT T-MOBILE AT 888-662-4662 & FOLLOW THEIR INSTRUCTIONS PRIOR TO PERFORMING ANY MAINTENANCE ORREPAIRS CLOSER THAN 3 FEET FROM THE ANTENNAS. THIS IS T-MOBILE SITE _________________7"5" 2"1"S T A Y B A C K 3 F E E T F R O M A N T E N N A 1-1/2"24"NOTICE TO WORKERS AVISO A TRABAJADORES RADIO FREQUENCY ANTENNAS ON THIS ROOF. PLEASE EXERCISE CAUTION AROUND ANTENNAS AND OBEY POSTED SIGNS AND/OR MARKINGS. FOR ACCESS TO RESTRICTED AREAS OR FOR FURTHER INFORMATION, PLEASE CALL 1-888-662-4662 (SITE NUMBER: __________) IN ACCORDANCE WITH FCC RULES 47 CFR 1.1310 EN ESTE TECHO HAY ANTENAS DE RADIOFRECUENCIA. POR FAVOR USE PRECAUCIÓN ALREDEDOR DE LAS ANTENAS Y OBEDEZCA LOS AVISOS Y/O MARCAS PUESTOS. PARA OBTENER ACCESO A LAS ZONAS RESTRINGIDAS O PARA OBTENER MÁS INFORMACIÓN, LLAME AL TELÉFONO 1-888-662-4662 (NUMERO DE SITIO: _________) DE ACUERDO A LAS REGLAS DE FCC 47 CFR 1.1310 1-888-662-4662 __________ FCC 47 CFR 1.1310 12"20"EMERGENCY SHUT DOWN FOR IMMEDIATE SHUT DOWN OF ALL RADIO FREQUENCY EMISSIONS OF THIS SITE, 1) CALL CONTACT NUMBER AND GIVE SITE IDENTIFICATION NO. CONTACT PHONE NUMBER: 1-888-662-4662 SITE IDENTIFICATION NUMBER: _________ 2) DISCONNECT POWER AT MAIN SERVICE DISCONNECT: CONTRACTOR TO SUBMIT PROPOSED WRITTEN DIRECTIONS FOR EACH OF (5) SIGNS TO PROJECT CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO ORDERING SIGNS 3) DISCONNECT BACK-UP POWER AT BATTERY DISCONNECT: CONTRACTOR TO SUBMIT PROPOSED WRITTEN DIRECTIONS FOR EACH OF (5) SIGNS TO PROJECT CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO ORDERING SIGNS N.T.S.1 GENERAL NOTES N.T.S.12 EMERGENCY SHUTDOWN SIGNAGE N.T.S.13 TRILINGUAL SIGNAGE N.T.S.3 WARNING, CAUTION AND NOTICE SIGNS N.T.S.2 INFORMATION SIGNAGE N.T.S.5 SHELTER SIGNAGE N.T.S.7 SHELTER SIGNAGE N.T.S.10 FCC ASR SIGNAGE N.T.S.6 DOOR/EQUIPMENT SIGNAGE N.T.S.8 SHELTER/CABINET DOOR SIGNAGE N.T.S.9 GATE SIGNAGE T-MOBILE CAUTION Beyond This Point you are entering a controlled area where RF Emissions may exceed the FCC Controlled Exposure Limits. Obey all posted signs and site guidelines for working in an RF environment. Ref:FCC 47CFR 1.1307(b) WARNING Beyond This Point you are entering a controlled area where RF Emissions exceed the FCC Controlled Exposure Limits. Failure to obey all posted signs and site guidelines could result in serious injury. Ref:FCC 47CFR 1.1307(b)T-MOBILE T-MOBILE NOTICE Beyond This Point you are entering an area where RF Emissions may exceed the FCC General Population Exposure Limits. Follow all posted signs and site guidelines for working in an RF environment. Ref:FCC 47CFR 1.1307(b) N.T.S.4 ROOFTOP SIGNAGE NOTICE GUIDELINES FOR WORKING IN RADIO FREQUENCY ENVIRONMENTS All personnel should have electromagnetic energy (EME) awareness training. All personnel entering this site must be authorized. Obey all posted signs. Assume all antennas are active. Before working on antennas, notify owners and disable appropriate transmitters. Maintain minimum 3 feet clearance from all antennas. Do not stop in front of antennas. Use personal RF monitors while working near antennas. Never operate transmitters without shields during normal operation. Do not operate base station antennas in equipment room. For information contact: 877-611-5868 TMO130956 12"12"N.T.S.11 EMERGENCY CONTACT SIGN In case of Emergency Contact T-MOBILE Please Reference Site ID Phone: 1-(800) 264-6620 Site ID FCC ID4.0"5.0" "SHALL MATCH SITE ID OF THIS PLAN" OWNER / OPERATOR NOTE: SITE ID LABEL TO BE AFFIXED AT OR NEAR THE POINT OF POWER CONNECTION WITH TZeS241 LABELING TAPE OR EQUIVALENT BLACK ON WHITE LABELING TAPE OF AT LEAST 18mm WIDTH WITH EXTRA-STRENGTH ADHESIVE. USE ANY COMPATIBLE P-TOUCH LABEL MAKER. TEXT SHOULD BE PRINTED IN ALL CAPS WITH MINIMUM HEIGHT OF 1/2". NOTE: SITE ID SHALL MATCH SITE ID IN PERMIT PLANS INFORMATION Obey all postings and boundaries beyond this point. Call T-Mobile at 1-888-662-4662 for more information.8"12" This is an ACCESS POINT to an Area with transmitting antennas. STATE: ______________ SWITCH: ________________________________ SITE ID: __________________________________________________________ SITE SIGNAGE GN-3 1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Licensor: Sheet Title: Sheet Number: Jurisdiction: Issued For: B 04/24/2025 95%CDs FOR REVIEW WM A 04/08/2025 90%CDs FOR REVIEW KP/WM REV DATE DESCRIPTION BY Prepared For: Engineer: 2840 HOWE ROAD, SUITE E MARTINEZ, CA 94553 www. TheCBRGroup.com Site Name: T-Mobile ID: OROVILLE QUINCY HWY PG&E NORTH TOWER CONSTRUCTION FOR OFFICIAL USE ONLY SCL0115C Site Address: 2867 ORO QUINCY HWY C:\Users\Wing Mok\Box\CBR General\T-MOBILE\T-Mobile Sites\SCL0115C\04 A&E\06 CAD\SCL0115C_GN-1.dwg, 4/24/2025 11:15:06 AM FIRE DEPARTMENT NOTES: 1.UNDER THE T-MOBILE PROJECT MANAGER'S DIRECTION, THE CONTRACTOR SHALL PROVIDE "HILTI" HIGH-PERFORMANCE FIRE STOP SYSTEM #FS601 AT ALL FIRE-RATED PENETRATION INSTALLED PER MANUFACTURER'S LATEST INSTALLATION SPECIFICATION. 2.ALL PENETRATIONS THROUGH FIRE-RATED ASSEMBLIES SHALL BE CONSTRUCTED SO AS TO MAINTAIN AN EQUAL OR GREATER FIRE RATING. 3.BUILDING UNDERGOING CONSTRUCTION, ALTERATION OR DEMOLITION SHALL BE IN ACCORDANCE WITH CFC CHAPTER 33 (FIRE SAFETY DURING CONSTRUCTION & DEMOLITION). 4.NEW AND EXISTING BUILDINGS SHALL BE PROVIDED WITH APPROVED ADDRESS IDENTIFICATION. THE ADDRESS IDENTIFICATION SHALL BE LEGIBLE AND PLAED IN A POSITION THAT IS VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. ADDRESS IDENTIFICATION CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND. (CFC SECTION 505 PREMISES IDENTIFICATION) 5.DECORATIVE MATERIALS SHALL BE MAINTAINED IN ACCORDANCE WITH CFC CHAPTER 8. 6.VALVES CONTROLLING THE WATER SUPPLY FOR AUTOMATIC SPRINKLER SYSTEMS, PUMPS, TANKS, WATER LEVELS AND TEMPERATURES, CRITICAL AIR PRESSURES, AND WATERFLOW SWITCHES ON ALL SPRINKLER SYSTEMS SHALL BE ELECTRICALLY SUPERVISED BY A LISTED FIRE ALARM CONTROL UNIT. (CFC SECTION 903.4) 7.INSTALLATION OF FIRE ALARM SYSTEMS SHALL BE IN ACCORDANCE WITH CFC SECTION 907. 8.PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN ACCORDANCE WITH CFC SECTIONS 906.1 & 906.2 AND CALIF. CODE OR REGULATIONS TITLE 19, DIVISION 1, CHAPTER 3. 9.CONTRACTOR SHALL VERIFY IN FIELD THE EXISTENCE OR INSTALLATION OF A FIRE EXTINGUISHER WITH A MINIMUM RATING OF A 2A-10BC, WITH A CHARGE STATUS ACCEPTABLE TO THE LOCAL FIRE AUTHORITY HAVING JURISDICTION. 10.COMPLETE PLANS AND SPECIFICATIONS FOR ALARM SYSTEMS FIRE-EXTINGUISHING SYSTEMS, INCLUDING AUTOMATIC SPRINKLERS AND OTHER FIRE-PROTECTION SYSTEMS SHALL BE SUBMITTED TO FIRE AND LIFE SAFETY FOR REVIEW AND APPROVAL IN INSTALLATION. (CFC SECTION 901.2) N.T.S.1 FIRE DEPARTMENT NOTES N.T.S.2 BATTERY FIRE SAFETY SIGN N.T.S.3 BATTERY CABINET NOTICE SIGN N.T.S.5 BATTERY SAFETY DATA SHEET N.T.S.6 BATTERY SPECIFICATION SHEET N.T.S.4 BATTERY LOAD CALCULATIONS BATTERY TYPE MODEL CAPACITY (AH)VOLTAGE CAPACITY (kWh)/BAT # OF EXISITING BAT # OF PROPOSED BAT FINAL # OF BAT kWh NORTHSTAR NSB190FT RED 183 12 2.196 0 12 12 26.35 AH = AMPERE HOURS BAT = BATTERY kWh = KILOWATT HOURS TOTAL kWh 26.35 T-MOBILE NOTICE Beyond This Point you are entering an area where RF Emissions may exceed the FCC General Population Exposure Limits. Follow all posted signs and site guidelines for working in an RF environment. Ref:FCC 47CFR 1.1307(b) BATTERY SPECIFICATIONS GN-4 1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Licensor: Sheet Title: Sheet Number: Jurisdiction: Issued For: B 04/24/2025 95%CDs FOR REVIEW WM A 04/08/2025 90%CDs FOR REVIEW KP/WM REV DATE DESCRIPTION BY Prepared For: Engineer: 2840 HOWE ROAD, SUITE E MARTINEZ, CA 94553 www. TheCBRGroup.com Site Name: T-Mobile ID: OROVILLE QUINCY HWY PG&E NORTH TOWER CONSTRUCTION FOR OFFICIAL USE ONLY SCL0115C Site Address: 2867 ORO QUINCY HWY C:\Users\Wing Mok\Box\CBR General\T-MOBILE\T-Mobile Sites\SCL0115C\04 A&E\06 CAD\SCL0115C_GN-4.dwg, 4/24/2025 11:15:10 AM OROVILLE Q U I N C Y H I G H W A Y LS-1 TIMOTHY SCHAD, L.S. 10699 ROUND VALLEY RD. GRASS VALLEY, CA. 95949 PHONE: (916) 947-7603 TIM@INITIALPOINT.COM OVERALL PARCEL 1"=100' SURVEY NOTES 1. ALL LATITUDES AND LONGITUDES ARE NAD 83, ALL ELEVATIONS ARE NAVD 88 (UNLESS NOTED OTHERWISE). 2. ALL BOUNDARY INFORMATION SHOWN HEREON HAS BEEN COMPILED FROM RECORD DATA. THIS IS NOT A BOUNDARY SURVEY. 3. DATE OF FIELD SURVEY JANUARY 6, 2025. 4. NO PRELIMINARY TITLE REPORT HAS BEEN PROVIDED, ANY EASEMENTS OR OTHER TITLE RELATED ISSUES NOT INCLUDED IN SAID REPORT WHICH ARE PART OF THE TITLE PROCESS MAY OR MAY NOT HAVE BEEN ADDRESSED, TIMOTHY F. SCHAD, L.S. ACCEPTS NO RESPONSIBILITY OR LIABILITY FOR BOUNDARY OR TITLE ITEMS ADDRESSED HEREON. THIS IS NOT A BOUNDARY SURVEY. 5. OVERHEAD UTILITY LINES ARE BASED ON A COMBINATION OF FIELD LOCATED DATA AND AERIAL IMAGERY AND ARE DEPICTED FOR REFERENCE ONLY. SCL0115C 480' NORTH OF 2867 OROVILLE QUINCY HWY. OROVILLE, CA. 95966 ELEC. TRANSMISSION TOWER SBE PCL. NO. 135-4-55-1 SITE SURVEY EXHIBIT LS-1 BASIS OF BEARING NOTE ALL BEARINGS SHOWN HEREON ARE PER PARCEL MAP RECORDED IN BOOK 70 OF MAPS AT PAGE 87, OFFICIAL RECORDS OF BUTTE COUNTY. LATITUDES AND LONGITUDES ARE NAD 83, ALL ELEVATIONS ARE NAVD 88 (UNLESS NOTED OTHERWISE). LEGEND PARCEL DESCRIPTION PARENT PARCEL PENDING RECEIPT OF PRELIMINARY TITLE REPORT REAL PROPERTY IN THE COUNTY OF BUTTE, STATE OF CALIFORNIA, DESCRIBED AS FOLLOWS: SBE PARCEL # 135-4-55-1 & 135-4-55B-1 BUTTE COUNTY APN:068-150-051 GEODETIC LOCATION DATE OF SURVEY: JANUARY 6, 2025 SITE NUMBER / NAME: SCL0115C TYPE: EXISTING ELECTRIC TRANSMISSION TOWER SITE ADDRESS: 480' NORTH OF 2867 OROVILLE QUINCY HIGHWAY OROVILLE, CA 95966 I, TIMOTHY SCHAD, HEREBY CERTIFY THE GEODETIC COORDINATES AT THE CENTERLINE OF THE EXISTING TOWER TO BE: LATITUDE= 39° 30' 24.70" NORTH (NAD83) (39.506861º) LONGITUDE= 121° 30' 08.25" WEST (NAD83) (-121.502292º) GROUND ELEVATION= 512.0' NAVD88 (0.0' A.G.L.) TOP HIGHEST EXISTING ANTENNA ELEV.= 596.5' NAVD88 (84.5' A.G.L.) TOP TOWER ELEV.= 656.3' NAVD88 (144.3' A.G.L.) (HIGHEST POINT) THE ACCURACY STANDARDS FOR THIS CERTIFICATION ARE AS FOLLOWS: GEODETIC COORDINATES: +/- FIFTEEN (15) FEET (NAD-83) ELEVATIONS: +/- THREE (3) FEET (NAVD-88) POLE DETAIL NO SCALE' SITE TOPOGRAPHY 1"=20'C:\Users\Wing Mok\Box\CBR General\T-MOBILE\T-Mobile Sites\SCL0115C\04 A&E\06 CAD\SCL0115C_SITE SURVEY.dwg, 4/24/2025 11:15:13 AM X X XX X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X X X X X XX X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X XXXXXXXX X X X X X XX X X X X X X XX X X X X XXXXX X X X X X X X X X X X X X X X X X X XX X X X XX X XX 0'32' SCALE: 1/32" = 1'-0" 64'16'96'8' 1 OVERALL SITE PLAN 120°240° 0°NORTH MAG.16°30'SYMBOLS & ABBREVIATIONS SECTION REFERENCE CENTERLINE ELEVATION REFERENCE CONCRETE SAND PLYWOOD GRAVEL EARTH MASONRY BRICK (N) (E) GROUNDING LINE WORK POINT MATCH LINE PROPERTY/LEASE LINE STEEL EXISTING NEW GROUND WELL EXISTING UTILITY POLE EXISTING LUMINAIRE SET POINT REVISION DETAIL REFERENCE GRID REFERENCE OVERHEAD SERVICE CONDUCTORS UNDERGROUND SERVICE CONDUCTORS SPOT ELEVATION (DATUM) FENCE BREAK LINE X XX XX XX XX XX XX FOUNDATION MONUMENT X OH OH OH UG UG UG X X X X TYP.TYPICAL A.G.L.ABOVE GROUND LEVEL U.N.O.UNLESS NOTED OTHERWISE N.T.S.NOT TO SCALE T.B.D.TO BE DETERMINED OVERALL SITE PLAN A-1 TYPICAL NOTE/S: 1.PRIOR TO CONSTRUCTION, PLEASE VERIFY IN FIELD ALL DIMENSIONS, LENGTHS, PROPERTY LINES, AND CONDUIT RUNS. - OROVILLE Q U I N C Y H W Y - ~ (E) FIELD ~~ (E) PRIVATE ACCESS ROAD ~A-3 1 A-4 1 (N) T-MOBILE EQUIPMENT AREA BE T A S E C T O R AZ = 1 2 0 ° GAMM A S E C T O R AZ = 2 4 0° A-2 1 A-2 2 (N) T-MOBILE ANTENNA AND RADIOS ON (E) UTILITY LATTICE TOWER A-3 1 A-3 2 ~ APN: 068-160-128 ~ ~ APN: 910-031-083 ~ (E) UTILITY VAULT (E) SECONDARY POWER VAULT (POWER P.O.C.) (E) FENCE (E)PROPERTY LINE, TYP. ~ (E) FIELD ~ A-3 2 A-4 2 (N) 15' WEED ABATEMENT AROUND TOWER (N) 10' GRAVEL FIREBREAK INCLUDING FELT DEBRIS BARRIER OUT FROM TOWER (N)T-MOBILE U/G POWER ROUTE FROM (E) SECONDARY POWER VAULT TO (N) METER PANEL (±313 FT) ~ APN: 068-150-070 ~ 1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Licensor: Sheet Title: Sheet Number: Jurisdiction: Issued For: B 04/24/2025 95%CDs FOR REVIEW WM A 04/08/2025 90%CDs FOR REVIEW KP/WM REV DATE DESCRIPTION BY Prepared For: Engineer: 2840 HOWE ROAD, SUITE E MARTINEZ, CA 94553 www. TheCBRGroup.com Site Name: T-Mobile ID: OROVILLE QUINCY HWY PG&E NORTH TOWER CONSTRUCTION FOR OFFICIAL USE ONLY SCL0115C Site Address: 2867 ORO QUINCY HWY (N)T-MOBILE U/G FIBER ROUTE FROM (E) UTILITY VAULT TO (N) 6160 CABINET (±65 FT) ~ APN: 068-150-051 ~ALPHA SECTORAZ = 340°C:\Users\Wing Mok\Box\CBR General\T-MOBILE\T-Mobile Sites\SCL0115C\04 A&E\06 CAD\SCL0115C_A-1.dwg, 4/24/2025 11:15:20 AM X XXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXX X X X X X X XXXXXXXXXXXXX X X X X X XXXXXXXXXXXX XXXXXXXX X X X X X X X XXXXXXXXXX X XXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXX X X X X X X XXXXXXXXXXXXX X X X X X XXXXXXXXXXXX 1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Licensor: Sheet Title: Sheet Number: Jurisdiction: Issued For: B 04/24/2025 95%CDs FOR REVIEW WM A 04/08/2025 90%CDs FOR REVIEW KP/WM REV DATE DESCRIPTION BY Prepared For: Engineer: 2840 HOWE ROAD, SUITE E MARTINEZ, CA 94553 www. TheCBRGroup.com Site Name: T-Mobile ID: OROVILLE QUINCY HWY PG&E NORTH TOWER CONSTRUCTION FOR OFFICIAL USE ONLY SCL0115C Site Address: 2867 ORO QUINCY HWY A-3 2 120°240° 0°NORTH MAG.16°30' 1 EXISTING EQUIPMENT PLAN 0'4'2' SCALE: 3/8" = 1'-0" 8'6' 120°240° 0°NORTH MAG.16°30'EXISTING AND PROPOSED EQUIPMENT PLANS A-2 2 PROPOSED EQUIPMENT PLAN 0'4'2' SCALE: 3/8" = 1'-0" 8'6' (E)CHAIN-LINK FENCE ENCLOSURE A-4 2 A-3 1 A-4 1 (N) 6160 CABINET MOUNTED ON (E) AND (N) CONCRETE SLAB (N) B160 CABINET MOUNTED ON (E) CONCRETE SLAB (N) CIENA BOX WITH (N) FIBER BOX BELOW MOUNTED TO (N) H-FRAME ~ (E) EQUIPMENT AREA ENCLOSURE ~ ~ (E) EQUIPMENT AREA ENCLOSURE ~ ~ DIRT ~ OUTLINE OF (N) CONCRETE SLAB (E) TOWER LEG (E) TOWER BASE 10'-0" (N) CONCRETE EXTENSION 8'-0" (N) CONCRETE EXTENSION10'-0" (N) CONCRETE EXTENSION (N) UNISTRUT-MOUNTED LED WORK LIGHT (N) 200A PPC CABINET WITH (N) CAM-LOCK BOX MOUNTED TO (N) H-FRAME (N) 200A METER PANEL MOUNTED TO (N) H-FRAME (N) NEMA3R-RATED HCS WINDER BOX MOUNTED ON (N) H-FRAME A-6 11 A-6.1 9 (2)(N) HCS CABLES; RUN THRU (N) CABLE ROUTE A-6 12 (N) PORTABLE FIRE EXTINGUISHER WITH 18-LB. CAPACITY (B:C RATING) INSIDE (N) FIRE EXTINGUISHER CABINET MOUNTED ON (N) H-FRAME A-6.1 11 E-3 12 A-6 6 A-6 9 A-6 5 A-6 9 (N) CHAIN-LINK FENCE ENCLOSURE A-6.1 5 (N) CONCRETE SLAB A-6.1 4 (N) 3'-0" WIDE ACCESS GATE 2'-0"8'-6" 11" (N) GPS ANTENNA A-6.1 11 A-6.1 9 A-6 12 E-3 8 A-6.1 9 E-3 10 E-3.1 4 A-6.1 9 1'-6"5"5" 12'-5" (NEW CHAIN-LINK FENCE)6"4'-7"4"6"(E) CONCRETE PLATFORM (E) ACCESS GATE (E) ACCESS GATE (E)CONCRETE SLAB (E)CONCRETE SLAB(E)CONCRETES SLAB(E)CONCRETE SLAB8'-0" (N) CONCRETE EXTENSION5'-6" E-3 9 (2)(N) 4"∅ STUB-UP CONDUITS 1'-6"6"3'-3"6"7'-7" (NEW CHAIN-LINK FENCE)(2)(N) 4"∅ STUB-UP CONDUITS AT TOWER LEG C:\Users\Wing Mok\Box\CBR General\T-MOBILE\T-Mobile Sites\SCL0115C\04 A&E\06 CAD\SCL0115C_A-2.dwg, 4/24/2025 11:15:22 AM 1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Licensor: Sheet Title: Sheet Number: Jurisdiction: Issued For: B 04/24/2025 95%CDs FOR REVIEW WM A 04/08/2025 90%CDs FOR REVIEW KP/WM REV DATE DESCRIPTION BY Prepared For: Engineer: 2840 HOWE ROAD, SUITE E MARTINEZ, CA 94553 www. TheCBRGroup.com Site Name: T-Mobile ID: OROVILLE QUINCY HWY PG&E NORTH TOWER CONSTRUCTION FOR OFFICIAL USE ONLY SCL0115C Site Address: 2867 ORO QUINCY HWY A-3 2 120°240° 0°NORTH MAG.16°30' 3 EXISTING ANTENNA AND EQUIPMENT PLAN - BELOW CONDUCTOR 0'4'2' SCALE: 1/4" = 1'-0" 12'8' 120°240° 0°NORTH MAG.16°30'EXISTING AND PROPOSED ANTENNA AND EQUIPMENT PLANS A-2.1 4 PROPOSED ANTENNA AND EQUIPMENT PLAN - BELOW CONDUCTOR 0'4'2' SCALE: 1/4" = 1'-0" 12'8' (E) PG&E TOWER A-3 1 A-4 1 (N) T-MOBILE ANTENNA APXVAALL18M-U-J20 MOUNTED ON (N) TOWER MOUNT ATTACHED TO (N) 12'-0" TOP HAT, TYP. (1 PER SECTOR, POS 1 - TOTAL 3) A-6 1 A-6 7 A-6.1 2 (N) T-MOBILE ANTENNA AIR 6419 B41 ATTACHED TO (N) TOWER MOUNT, TYP. (1 PER SECTOR, POS 2 - TOTAL 3) BE T A S E C T O R AZ = 1 2 0 ° 1 EXISTING ANTENNA AND EQUIPMENT PLAN - ABOVE CONDUCTOR 0'4'2' SCALE: 1/4" = 1'-0" 12'8' 2 PROPOSED ANTENNA AND EQUIPMENT PLAN - ABOVE CONDUCTOR 0'4'2' SCALE: 1/4" = 1'-0" 12'8' (E) TOWER BASE 120°240° 0°NORTH MAG.16°30'120°240° 0°NORTH MAG.16°30'65° (TY P . ) (2)(N) HCS CABLES; RUN FROM (N) STUB-UP CONDUITS ALONG TOWER LEG UP TO (N) RADIOS A-6.1 1 GAM M A S E C T O R AZ = 2 4 0° BE T A S E C T O R AZ = 1 2 0 ° 65° (TY P . ) GAM M A S E C T O R AZ = 2 4 0° (N) T-MOBILE RADIO 4460 B25+B66 MOUNTED ON (N) TOWER MOUNT ATTACHED TO (N) H-FRAME, TYP. (1 PER SECTOR - TOTAL 3) (N) T-MOBILE RADIO 4480 B71+B85 MOUNTED ON (N) TOWER MOUNT, ATTACHED TO (N) H-FRAME, TYP. (1 PER SECTOR - TOTAL 3) (E) PG&E TOWER (E) TOWER BASE A-6 2 A-6 7 A-6.1 2 A-6 3 A-6 8 A-6.1 2 A-6 4 A-6 8 A-6.1 2 A-3 1 A-4 1 A-3 2 A-4 2 A-4 2 (N) T-MOBILE 12'-0" TOP HAT (2)(N) T-MOBILE TMAs MOUNTED BEHIND (N) ANTENNA (2 PER SECTOR - TOTAL 6) (24)(N) 7/8"∅ COAX FEEDERS FROM (N) RADIOS TO ANTENNAS ON TOP HAT ALPHA SECTORAZ = 340°ALPHA SECTORAZ = 340°C:\Users\Wing Mok\Box\CBR General\T-MOBILE\T-Mobile Sites\SCL0115C\04 A&E\06 CAD\SCL0115C_A-2.1.dwg, 4/24/2025 11:15:29 AM 0'-0" A.G.L. GROUND LEVEL ±84'-6" A.G.L. TOP OF (E) ANTENNA (BY OTHERS) ±97'-10" A.G.L. BOTTOM OF (E) CONDUCTORS ±130'-10" A.G.L. BOTTOM OF (E) CONDUCTORS ±144'-4" A.G.L. TOP OF (E) LATTICE TOWER ±66'-10" A.G.L. BOTTOM OF (E) ANTENNA (BY OTHERS) 0'-0" A.G.L. GROUND LEVEL ±156'-4" A.G.L. TOP OF (N) TOP HAT ±66'-10" A.G.L. BOTTOM OF (E) ANTENNA (BY OTHERS) ±97'-10" A.G.L. BOTTOM OF (E) CONDUCTORS ±130'-10" A.G.L. BOTTOM OF (E) CONDUCTORS 10'-0"VERTICALCLERANCE10' - 0 " RA D I A L CL E A R A N C E (TY P . ) ±61'-0" A.G.L. RAD CENTER OF (N) T-MOBILE ANTENNAS ±58'-0" A.G.L. BOTTOM OF (N) ANTENNA MOUNT ±150'-0" A.G.L. RAD CENTER OF (N) T-MOBILE ANTENNAS ±144'-4" A.G.L. TOP OF (E) LATTICE TOWER ±64'-0" A.G.L. TOP OF (N) ANTENNA MOUNT ±57'-0" A.G.L. TOP OF (N) RADIO MOUNT ±51'-0" A.G.L. BOTTOM OF (N) RADIO MOUNT ±54'-0" A.G.L. CENTERLINE OF (N) T-MOBILE RADIOS EXISTING AND PROPOSED ELEVATIONS (SOUTH) A-30'8' SCALE: 1/8" = 1'-0" 24'16'4' 2 PROPOSED ELEVATION (SOUTH) 1 EXISTING ELEVATION (SOUTH) 0'8' SCALE: 1/8" = 1'-0" 24'16'4' (N) T-MOBILE ANTENNA AIR 6419B41 MOUNTED ON (N) H-FRAME ATTACHED TO (N) TOWER MOUNT (BETA SECTOR, POS 2) (N) T-MOBILE ANTENNA APXVAALL18M-U-J20 ATTACHED TO (N) TOWER MOUNT (1 PER SECTOR - TOTAL 3) (E) ANTENNAS BY OTHERS, TYP. (E) EQUIPMENT INSIDE CHAIN-LINK FENCE ENCLOSURE ON CONCRETE SLAB (BY OTHERS) (E) POWER CONDUCTOR, TYP. (N) T-MOBILE RADIO 4460 B25+B66 MOUNTED TO (N) TOWER MOUNT, ATTACHED TO (N) H-FRAME, TYP. (N) T-MOBILE RADIO 4480 B71+B85 MOUNTED TO (N) TOWER MOUNT, ATTACHED TO (N) H-FRAME, TYP. (N) T-MOBILE EQUIPMENT MOUNTED INSIDE (N) CHAIN-LINK FENCE ENCLOSURE ON (E) AND (N) CONCRETE SLAB (BEYOND) A-6 2 A-6 7 A-6.1 2 A-6 3 A-6 8 A-6.1 2 A-6 4 A-6 8 A-6.1 21'-0"1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Licensor: Sheet Title: Sheet Number: Jurisdiction: Issued For: B 04/24/2025 95%CDs FOR REVIEW WM A 04/08/2025 90%CDs FOR REVIEW KP/WM REV DATE DESCRIPTION BY Prepared For: Engineer: 2840 HOWE ROAD, SUITE E MARTINEZ, CA 94553 www. TheCBRGroup.com Site Name: T-Mobile ID: OROVILLE QUINCY HWY PG&E NORTH TOWER CONSTRUCTION FOR OFFICIAL USE ONLY SCL0115C Site Address: 2867 ORO QUINCY HWY (N) T-MOBILE 12'-0" TOP HAT12'-0"TOP HAT(2)(N) T-MOBILE TMAs MOUNTED BEHIND (N) ANTENNA (2 PER SECTOR - TOTAL 6) (24)(N) 7/8"∅ COAX FEEDERS FROM (N) RADIOS TO ANTENNAS ON TOP HAT (2)(N) HCS CABLES FROM (N) 6160 CABINET TO (N) RADIOS A-6 1 A-6 7 A-6 10 A-6.1 1 (2)(N) STUB-UP CONDUITS AT TOWER LEG C:\Users\Wing Mok\Box\CBR General\T-MOBILE\T-Mobile Sites\SCL0115C\04 A&E\06 CAD\SCL0115C_A-3.dwg, 4/24/2025 11:15:35 AM 0'-0" A.G.L. GROUND LEVEL ±97'-10" A.G.L. BOTTOM OF (E) CONDUCTORS ±130'-10" A.G.L. BOTTOM OF (E) CONDUCTORS ±66'-10" A.G.L. BOTTOM OF (E) ANTENNA (BY OTHERS) ±156'-4" A.G.L. TOP OF (N) TOP HAT ±150'-0" A.G.L. RAD CENTER OF (N) T-MOBILE ANTENNA ±144'-4" A.G.L. TOP OF (E) LATTICE TOWER ±61'-0" A.G.L. TOP OF (N) T-MOBILE ANTENNAS ±58'-0" A.G.L. BOTTOM OF (N) ANTENNA MOUNT ±64'-0" A.G.L. TOP OF (N) ANTENNA MOUNT ±57'-0" A.G.L. TOP OF (N) RADIO MOUNT ±51'-0" A.G.L. BOTTOM OF (N) RADIO MOUNT ±54'-0" A.G.L. CENTERLINE OF (N) T-MOBILE RADIOS EXISTING AND PROPOSED ELEVATIONS (EAST) A-40'8' SCALE: 1/8" = 1'-0" 24'16'4' 2 PROPOSED ELEVATION (EAST) 1 EXISTING ELEVATION (EAST) 0'8' SCALE: 1/8" = 1'-0" 24'16'4' (E) ANTENNAS BY OTHERS, TYP. 1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Licensor: Sheet Title: Sheet Number: Jurisdiction: Issued For: B 04/24/2025 95%CDs FOR REVIEW WM A 04/08/2025 90%CDs FOR REVIEW KP/WM REV DATE DESCRIPTION BY Prepared For: Engineer: 2840 HOWE ROAD, SUITE E MARTINEZ, CA 94553 www. TheCBRGroup.com Site Name: T-Mobile ID: OROVILLE QUINCY HWY PG&E NORTH TOWER CONSTRUCTION FOR OFFICIAL USE ONLY SCL0115C Site Address: 2867 ORO QUINCY HWY (N) T-MOBILE ANTENNA AIR 6419B41 MOUNTED ON (N) H-FRAME ATTACHED TO (N) TOWER MOUNT (ALPHA SECTOR, POS 2) (N) T-MOBILE ANTENNA APXVAALL18M-U-J20 ATTACHED TO (N) TOWER MOUNT (ALPHA SECTOR, POS 1) (N) T-MOBILE RADIO 4460 B25+B66 MOUNTED TO (N) TOWER MOUNT, ATTACHED TO (N) H-FRAME, TYP. (N) T-MOBILE RADIO 4480 B71+B85 MOUNTED TO (N) TOWER MOUNT, ATTACHED TO (N) H-FRAME, TYP. A-6 2 A-6 7 A-6.1 2 A-6 3 A-6 8 A-6.1 2 A-6 4 A-6 8 A-6.1 21'-0"(N) T-MOBILE EQUIPMENT MOUNTED INSIDE (N) CHAIN-LINK FENCE ENCLOSURE ON (E) AND (N) CONCRETE SLAB (BEYOND) (N) T-MOBILE 12'-0" TOP HAT12'-0"TOP HAT(E) EQUIPMENT INSIDE CHAIN-LINK FENCE ENCLOSURE ON CONCRETE SLAB (BY OTHERS) (2)(N) T-MOBILE TMAs MOUNTED BEHIND (N) ANTENNA (2 PER SECTOR - TOTAL 6) A-6 10 A-6 1 A-6 7 (24)(N) 7/8"∅ COAX FEEDERS FROM (N) RADIOS TO ANTENNAS ON TOP HAT (2)(N) HCS CABLES FROM (N) 6160 CABINET TO (N) RADIOS A-6.1 1 (2)(N) STUB-UP CONDUITS AT TOWER LEG C:\Users\Wing Mok\Box\CBR General\T-MOBILE\T-Mobile Sites\SCL0115C\04 A&E\06 CAD\SCL0115C_A-4.dwg, 4/24/2025 11:15:39 AM ANTENNA SCHEDULE (VERIFY WITH CURRENT RFDS) SECTOR EXISTING/PROPOSED ANTENNA SIZE (INCHES) (H X W X D) ANTENNA RAD CENTER AZIMUTH ACTIVE TECHNOLOGY RADIO (QTY)TMA / MULTIPLEXER (QTY)FIBER, COAX TYPE AND QUANTITY (LENGTH) A1 PROPOSED RFS - APXVLL18M-U-J20 (OCTO)71.8" X 19.7" X 8.5"150'-0" 340° N600, L700, L2100, N1900, L1900, N2100 (1) RADIO 4480 B71+B85, (1) RADIO 4460 B25+B66 (2) TMAT19G21BL26-21 STYLE 3CY TMA (8) 7/8" COAX - 100 FT (6) FIBER JUMPER - 2F SM OUTDOORCON-LCD W COVER 5M (8) COAX JUMPER A2 PROPOSED AIR 6419 B41 (ACTIVE ANTENNA - MASSIVE MIMO)33.6" X 20.0" X 6.3"61'-0"N2500 --(2) FIBER JUMPER - 2F SM OUTDOORCON-LCD W COVER 5M - 10 FT ANTENNA AND EQUIPMENT SCHEDULE A-5 ALPHA PROPOSED EQUIPMENT SCHEDULE (AT EQUIPMENT AREA) ENCLOSURE TYPE ENCLOSURE 6160_V2 AC B160 BASEBAND RP 6651 (N2500), RP 6651 (N600, N1900, N2100, L700, L1900, L2100)- TRANSPORT SYSTEM (1) CSR IXRE V2 (GEN 2)- HYBRID CABLE SYSTEM (2) HYBRID TRUNK 6/24 4AWG 25M - GAMMA RAN SCOPE OF WORK (VERIFY LATEST RFDS) 1.) ADD (1) RP6651 FOR L7/N6 + L19/L21/N19/N21 MMBB. 2.) ADD (1) RP6651 FOR N2500 3.) ADD (1) iXRE ROUTER 4.) ADD E6160 AND B160 CABINETS 5.) ADD (2) 6X24 HCS 4AWG 25M BETA 1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Licensor: Sheet Title: Sheet Number: Jurisdiction: Issued For: B 04/24/2025 95%CDs FOR REVIEW WM A 04/08/2025 90%CDs FOR REVIEW KP/WM REV DATE DESCRIPTION BY Prepared For: Engineer: 2840 HOWE ROAD, SUITE E MARTINEZ, CA 94553 www. TheCBRGroup.com Site Name: T-Mobile ID: OROVILLE QUINCY HWY PG&E NORTH TOWER CONSTRUCTION FOR OFFICIAL USE ONLY SCL0115C Site Address: 2867 ORO QUINCY HWY ANTENNA SCHEDULE (VERIFY WITH CURRENT RFDS) SECTOR EXISTING/PROPOSED ANTENNA SIZE (INCHES) (H X W X D) ANTENNA RAD CENTER AZIMUTH ACTIVE TECHNOLOGY RADIO (QTY)TMA / MULTIPLEXER (QTY)FIBER, COAX TYPE AND QUANTITY (LENGTH) B1 PROPOSED RFS - APXVLL18M-U-J20 (OCTO)71.8" X 19.7" X 8.5"150'-0" 120° N600, L700, L2100, N1900, L1900, N2100 (1) RADIO 4480 B71+B85, (1) RADIO 4460 B25+B66 (2) TMAT19G21BL26-21 STYLE 3CY TMA (8) 7/8" COAX - 100 FT (6) FIBER JUMPER - 2F SM OUTDOORCON-LCD W COVER 5M (8) COAX JUMPER B2 PROPOSED AIR 6419 B41 (ACTIVE ANTENNA - MASSIVE MIMO)33.6" X 20.0" X 6.3"61'-0"N2500 --((2) FIBER JUMPER - 2F SM OUTDOORCON-LCD W COVER 5M - 10 FT ANTENNA SCHEDULE (VERIFY WITH CURRENT RFDS) SECTOR EXISTING/PROPOSED ANTENNA SIZE (INCHES) (H X W X D) ANTENNA RAD CENTER AZIMUTH ACTIVE TECHNOLOGY RADIO (QTY)TMA / MULTIPLEXER (QTY)FIBER, COAX TYPE AND QUANTITY (LENGTH) C1 PROPOSED RFS - APXVLL18M-U-J20 (OCTO)71.8" X 19.7" X 8.5"150'-0" 240° N600, L700, L2100, N1900, L1900, N2100 (1) RADIO 4480 B71+B85, (1) RADIO 4460 B25+B66 (2) TMAT19G21BL26-21 STYLE 3CY TMA (8) 7/8" COAX - 100 FT (6) FIBER JUMPER - 2F SM OUTDOORCON-LCD W COVER 5M (8) COAX JUMPER C2 PROPOSED AIR 6419 B41 (ACTIVE ANTENNA - MASSIVE MIMO)33.6" X 20.0" X 6.3"61'-0"N2500 --((2) FIBER JUMPER - 2F SM OUTDOORCON-LCD W COVER 5M - 10 FT C:\Users\Wing Mok\Box\CBR General\T-MOBILE\T-Mobile Sites\SCL0115C\04 A&E\06 CAD\SCL0115C_A-5.dwg, 4/24/2025 11:15:43 AM OR APPROVED EQUIVALENT TMA DETAIL MANUFACTURER: COMMSCOPE MODEL #: TMAT19G21BL26-21 DIMENSIONS: 9.3"H x 10.0"W x 4.2"D WEIGHT: 16.7 LBS 10"4.2"9.3"VENT MANUFACTURER: ERICSSON MODEL: AIR6419 B41 HEIGHT: 33.6 in. WIDTH: 20.0 in. DEPTH:6.3 in. WEIGHT: 68.5 lbs. WIND SPEED, MAXIMUM: 150 MPH FREQUENCY: REFER TO RF DATA SHEET AIR6419 ANTENNA DETAIL33.66.3"16.1" NOT USED 19.7"8.5"71.8"APXVAALL18M-U-J20 ANTENNA DETAIL MANUFACTURER: AMPHENOL MODEL: APXVAALL18M-U-J20 HEIGHT: 71.8 in. WIDTH: 19.7 in. DEPTH:8.5 in. WEIGHT: 57.5 lbs. WIND SPEED, MAXIMUM: 150 MPH FREQUENCY: REFER TO RF DATA SHEET 24" X 24" X 8" NEMA3 ENCLOSURE FOR WINDER BOX; TALLEY PART #INFAB-24248RBG-CD 24.0"8.0"WINDER BOX DETAIL 2"∅ CONDUITS TO BE SECURED TO H-FRAME W/ SNAP-IN AND RUBBER GROMMETS, TYP. H-FRAME TO 6160 CABINET HCS CABLES WINDER BOX GROUND 24.0"24.0" LED SERVICE LIGHT MANUFACTURER: NUVO (SATCO) MODEL: 65-541 DIMENSIONS: 7.24"H X 9.91"W X 2.44"D WEIGHT: 1.14 LBS. (NET) ELECTRICAL INFO: WATTAGE: 15W/25W/35W LUMEN OUTPUT: 1800L-4900L TECHNOLOGY: LED FIXTURE TYPE: FLOOD LIGHT LENS MATERIAL: TEMPERED GLASS MATERIAL: DIE-CAST ALUMINUM RADIO 4460 DETAIL 15.1"17.0"11.9"MANUFACTURER: ERICSSON MODEL: RADIO 4460 B25+B66 DEPTH:11.9 in. LENGTH: 17.0 in. WIDTH: 15.1 in. WEIGHT: ~109 lbs. FREQUENCY: REFER TO RF DATA SHEET OR APPROVED EQUIVALENT 6160 CABINET DETAIL 63.0"33.5"25.6" MANUFACTURER: ERICSSON MODEL: 6160 AC V2 HEIGHT: 63.0" WIDTH: 25.6" DEPTH:33.5" WEIGHT: 320 LBS. (NET) MAX WEIGHT: 605 LBS.25.6"25.6"16.5"21.5" CL CL NOT USED NOT USED NOT USED NOT USEDRADIO 4480 DETAIL 15.4"21.8"7.5"MANUFACTURER: ERICSSON MODEL: RADIO 4480 B71+B85 DEPTH:7.5 in. LENGTH: 21.8 in. WIDTH: 15.4 in. WEIGHT: ~93 lbs. FREQUENCY: REFER TO RF DATA SHEET OR APPROVED EQUIVALENT 63.0"29.6"26.0" MANUFACTURER: ERICSSON MODEL: B160 HEIGHT: 63.0" WIDTH: 26.0" DEPTH:29.6" WEIGHT: 430 LBS. (NET) MAX WEIGHT: 1883.0 LBS (INCLUDING BATTERIES) B160 CABINET DETAIL 25.6" CL CL 27.6"22.45"21.65" ANTENNA MOUNTING DETAIL OR APPROVED EQUIVALENT 44 4 2 2 5 7 6 GENERAL MOUNTING BRACKET PARTS 1 QTY 1 1 3 ITEM 1 2 DESCRIPTION Bracket, Downtilt, Antenna Adaptor, Pole, Lower Bracket, Downtilt, Pole 5/16 Split Washer 1/2 Split Washer 5/16 X 1 Hex Head Bolt 1/2 X 1 Hex Head Bolt 1 2 34 5 6 7 NOTES: 1.EACH ANTENNA HAS ITS OWN MOUNTING BRACKET KIT, TILTING ATTACHMENT AND CABLE KIT SOLD SEPARATELY. GC TO UTILIZE TILTING ATTACHMENT METHOD AS NEEDED. SEE ANTENNA SPECIFICATION SHEET. 2.VERIFY EXISTING CONDITIONS. ALL MOUNTING ATTACHMENTS AND HARDWARE SHALL BE VERIFIED BY CONSTRUCTION MANAGER. 3.INSERT SCISSOR BRACKETS BETWEEN THE UPPER ANTENNA MOUNTING BRACKET AND THE UPPER POLE ADAPTER BRACKET. SECURE USING 1/2-IN. HARDWARE PROVIDED. 4.TO SET THE DEGREE OF DOWNTILT, ALIGN THE DESIRED HOLES ON THE SCISSOR BRACKETS AND SECURE USING 5/16 INCH HARDWARE PROVIDED. 5.THE NUMBER OF CONNECTORS WILL VARY BASED ON ANTENNA TYPE. 6.PLACE RF TERMINATIONS OR CAPS ON ALL UNUSED ANTENNA PORTS. (N) RRU WITH RRU SUPPORT KIT PROVIDED BY MANUFACTURER RADIO MOUNT TO MOUNT PIPE DETAIL (N) 1/2"∅ U-BOLT (TOP AND BOTTOM) MOUNT PIPE OR APPROVED EQUIVALENT CABINET ANCHORAGE DETAIL 4-1/2" MIN. 1/2"∅ HILTI KWIK BOLT TZ2 WITH 3-5/8" (MIN.) EMBEDMENT DEPTH PER ICC-ESR #4266 (STAINLESS STEEL) CONCRETE SLAB INSULATING WASHER FLAT WASHER LOCK WASHER NOTE: SPECIAL INSPECTION IS REQUIRED FOR THE INSTALLATION OF THE ANCHOR BOLTS ACCORDING TO ICC-ESR #4266 CABINET N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: DETAILS A-6 N.T.S SCALE: N.T.S SCALE: 1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Licensor: Sheet Title: Sheet Number: Jurisdiction: Issued For: B 04/24/2025 95%CDs FOR REVIEW WM A 04/08/2025 90%CDs FOR REVIEW KP/WM REV DATE DESCRIPTION BY Prepared For: Engineer: 2840 HOWE ROAD, SUITE E MARTINEZ, CA 94553 www. TheCBRGroup.com Site Name: T-Mobile ID: OROVILLE QUINCY HWY PG&E NORTH TOWER CONSTRUCTION FOR OFFICIAL USE ONLY SCL0115C Site Address: 2867 ORO QUINCY HWY C:\Users\Wing Mok\Box\CBR General\T-MOBILE\T-Mobile Sites\SCL0115C\04 A&E\06 CAD\SCL0115C_A-6.dwg, 4/24/2025 11:15:47 AM NOT USED NOT USED TYPICAL WOVEN WIRE GATE/FENCE NOTES (INSTALL SWING GATES PER ASTM F- 900) 1.GATE POST, CORNER, TERMINAL OR PULL POST SHALL BE 2-7/8"∅ SCHEDULE 40 FOR GATE WIDTHS UP THROUGH 6 FEET OR 12 FEET FOR DOUBLE SWING GATE PER ASTM-F1083. 2.LINE POST: 2-3/8"∅ SCHEDULE 40 PIPE PER ASTM-F1083. 3.GATE FRAME: 1-1/2"∅ SCHEDULE 40 PIPE PER ASTM-F1083. 4.TOP RAIL & BRACE RAIL: 1-1/4"∅ SCHEDULE 40 PIPE PER ASTM-F1083. 5.FABRIC: 9-GA. CORE WIRE SIZE 2" MESH, CONFORMING TO ASTM-A392 CLASS 1. 6.TIE WIRE: MINIMUM 11-GA GALVANIZED STEEL INSTALL A SINGLE WRAP TIE WIRE AT POSTS AND RAILS AT MAX. 24" INTERVALS. INSTALL HOG RINGS ON TENSION WIRE AT 24" INTERVALS. 7.TENSION WIRE: 7-GA. GALVANIZED STEEL. 8.GATE LATCH: 1-3/8" O.D. PLUNGER ROD W/ MUSHROOM TYPE CATCH AND LOCK (KEYED ALIKE FOR ALL SITES OR COMBINATION AS SPECIFIED BY AWS). 9.LOCAL ORDINANCE FOR BARBED WIRE PERMIT SHALL GOVERN INSTALLATION. 10.ALL WORK SHALL CONFORM WITH THE PROJECT SPECIFICATIONS. CHAIN-LINK ACCESS GATE 1'-0"∅ PLAIN CONCRETE OR SAKRETE PIER, TYP. L C GATE POST SEE DWGS FOR WIDTH GATE POSTCL TOP BRACE RAIL (CLR OPNG) FINISH FLOOR DIAGONAL ROD WITH STEEL TURNBUCKLE GATE FRAME 1'-0"3'-0"STRETCHER BAR GATE LATCH W/ LOCK VERTICAL PRIVACY SLATS (HDPE OR APPROVED EQ.) BETWEEN CHAIN-LINK FENCE NOTE: ALL CONCRETE MUST HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI @ 28 DAYS. NOT USEDN.T.S SCALE:H-FRAME ON CONCRETE SLAB DETAIL 5"5"DETAIL 'A-A' 1/4 DETAIL 'B-B' NOTE: SPECIAL INSPECTION IS REQUIRED FOR THE INSTALLATION OF THE ANCHOR BOLTS ACCORDING TO ICC-ESR #4266 1-1/2" TYP. 9" MIN. TO EDGE OF CONCRETE TOP OF SLAB 8"x8"x3/8" STEEL PLATE 3-1/2" O.D. POST 3-1/2" O.D. POST 8"x8"x3/8" STEEL PLATE UNISTRUT PIPE/CONDUIT CLAMP P1119 OR P2558-35 (GALV.), TYP.; FOLLOW MANUFACTURER RECOMMENDATIONS FOR BOLT TORQUE 3-1/2" O.D. POST (4) 1/2" KWIK BOLT TZ2 WITH MINIMUM 3-3/4" EMBEDMENT INTO CONCRETE TOP OF CONCRETE SLAB UNISTRUT P1000 (GALV) UNISTRUT P1000 (GALV) UNISTRUT P1000 (GALV)5'-0" MAX.FIELD LOCATEFIELD LOCATEPER PLAN (POST SPACING IS MAX: 4-FT., PROVIDE EXTRA POST) A B UNISTRUT P1000 (GALV) 3-1/2"∅ SCH.40 PIPE (GALV) OR 3-1/2"∅ RGS CONDUIT (GALV) PIPE CAP, TYP. A B CL EQUAL SPACINGEQUAL SPACING UNISTRUT P1000 (GALV) NOT USED 3"4"3" (N) CONCRETE PAD (E) CONCRETE PAD USE 7"-LONG #4 DOWEL @ 24" O.C.; DRILL HOLES, BRUSH, BLOW CLEAN AND SET DOWELS IN HILTI HIT-HY 200 V3 ADHESIVE (N) TO (E) CONCRETE PAD DETAIL GPS ANTENNA MOUNTING DETAIL 1.THE ELEVATION AND LOCATION OF THE GPS ANTENNA SHALL BE IN ACCORDANCE WITH THE FINAL RF REPORT. 2.THE GPS ANTENNA MOUNT IS DESIGNED TO FASTEN TO A STANDARD 1-1/4"∅, SCHEDULE 40, GALVANIZED STEEL OR STAINLESS STEEL PIPE. THE PIPE MUST NOT BE THREADED AT THE ANTENNA STEEL PIPE. THE PIPE MUST NOT BE THREADED AT THE ANTENNA MOUNT END. THE PIPE SHALL BE CUT TO THE REQUIRED LENGTH (MINIMUM OF 18") USING A HAND OR ROTARY PIPE CUTTER TO ASSURE A SMOOTH AND PERPENDICULAR CUT. A HACK SAW SHALL NOT BE USED. THE CUT PIPE END SHALL BE DEBURRED AND SMOOTH IN ORDER TO SEAL AGAINST THE NEOPRENE GASKET ATTACHED TO THE ANTENNA MOUNT. NOTES: GPS ANTENNA KIT BY ERICSSON PART NO. PKG6-2DUX-GPSANT OR APPROVED EQUIVALENT ANTENNA PIPE MOUNT; SEE NOTES CONCRETE PAD DETAIL #5 AND SMALLER & WWF BEAMS AND COLUMNS CONCRETE CAST AGAINST EARTH........3 IN. CONCRETE EXPOSED TO EARTH OR WEATHER: CONCRETE NOT EXPOSED TO EARTH OR WEATHER OR NOT CAST AGAINST THE GROUND: 1.ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACI 336, ASTM A184, ASTM A185 AND THE DESIGN AND CONSTRUCTION SPECIFICATION PER CAST-IN-PLACE CONCRETE. 2.ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS, UNLESS NOTED OTHERWISE. 3.REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, DEFORMED UNLESS NOTED OTHERWISE. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 WELDED STEEL WIRE FABRIC UNLESS NOTED OTHERWISE. SPLICES SHALL BE CLASS "B" AND ALL HOOKS SHALL BE STANDARD, UNO. 4.THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: 5.A CHAMFER 3/4" SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, UNO, IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. 6.INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHOR SHALL BE PER MANUFACTURER'S WRITTEN RECOMMENDED PROCEDURE. THE ANCHOR BOLT, DOWEL OR ROD SHALL CONFORM TO MANUFACTURER'S RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON THE DRAWINGS. NO REBAR SHALL BE CUT WITHOUT PRIOR ENGINEERING APPROVAL WHEN DRILLING HOLES IN CONCRETE. EXPANSION BOLTS SHALL BE PROVIDED BY RAMSET/REDHEAD OR APPROVED EQUAL, UNLESS NOTED OTHERWISE. SPECIAL INSPECTIONS, WHEN REQUIRED BY GOVERNING CODES SHALL BE PERFORMED IN ORDER TO MAINTAIN MANUFACTURER'S MAXIMUM ALLOWABLE LOADS. CONCRETE AND REINFORCING STEEL NOTES: #6 AND LARGER SLAB AND WALL ........................3/4 IN. ...............1 1/2 IN. .........1 1/2 IN. ..........................2 IN. EXISTING GRADE VARIES 1'-0"MIN.6" THICK CONCRETE SLAB WITH #4 REINFORCING BAR @ 24" O.C. EA. WAY DG57 WITH WEED GUARD FABRIC UNDERNEATH 4" MIN10 MILS MOISTURE BARRIER AND 2-1/2" SAND BED FOR SLAB ON GRADE 6" MIN. 1 #4 TYP. ALL SIDES #4 @ 24" O.C. TYP. 10 10 7.GRAVEL SHALL BE NATURAL OR CRUSHED STONE WITH 100% PASSING 1 INCH SIEVE. 8.DIMENSIONS SHOWN ARE EXACT MINIMUM PAD SIZES REQUIRED FOR EQUIPMENT LAYOUTS - CONTRACTOR MAY ROUND UP TO THE NEAREST FOOT (OR HALF FOOT) IF LEASE AREA AND SPACE PERMIT. UNIVERSAL T-BRACKET MOUNT DETAIL OR APPROVED EQUIVALENT T-1200/T1800 MOUNT PARTS ITEM QTY PART NO.PART DESCRIPTION LENGTH UNIT WT.NET WT. 1 1 X-T1800 T-BRACKET WELDMENT FOR T-1800 6.48 6.48 1 1 X-T1200 T-BRACKET WELDMENT FOR T-1200 5.04 5.04 2 1 UTB-BB BACK BRACKET FOR UNIVERSAL T-BRACKETS 1.89 1.89 3 4 G38FW 3/8" HDG USS FLATWASHER 0.01 0.05 4 4 G38LW 3/8" HDG LOCKWASHER 0.01 0.03 5 4 G38NUT 3/8'' HDG HEAVY 2H HEX NUT 0.03 0.14 6 2 G38R-9.75 3/8" X 9-3/4" THREADED ROD (HDG.)0.05 0.70 NOTE: USED TO BE MICROFLECT (VALMONT) B2252 TOTAL WT. #9.29 MANUFACTURER: SITE PRO 1 (VALMONT) 1 2 1-1/2" TO 6" ROUND MEMBER LEGS OR 2-1/2" TO 5" 90° ANGLE LEGS 4 5 6 3 ACTUAL BRACKET LENGTH T1200: 17.3125" T1800: 25.25" 6x24 HYBRID CABLE SYSTEM 5m 0.5m 0.8m 0.9m0.7m 1.0m 1000mm* 1060mm* 1120mm* 1180mm* Bundle1: Bundle2: Bundle3: Bundle4: BottomFiberPigtailLengths 86mm diam, L=250mm, max Optical fiber and DC conductor breakout 4x6fiber pairs 170 mm 50mm diam., max Bulkhead fitting Cable Assembly Legnth 0.3m0.2m 2m Color coded 4AWG Conductor pairs(6) Color coded pair groups 4x6 fiber Fiber pairs terminated with LC plug, protected with dust cap (see table above for breakout lengths/bundle) Fiber pairs terminated w/ ODC plug, protected with weatherproof cap Breakout DC conductors (6 pairs, 6AWG), w/shrink cap on tips *Each subsequent pair in the bundle staggered in length to clear previous pair's connector 6x24 cables will be utilized in the same applications as existing 6x12 products. NOTE/S: 1.GENERAL CONTRACTOR TO PROVIDE ALL NECESSARY HCS SUPPORT REQUIRED BY T-MOBILE. QTY RECOMMENDED CONDUIT SIZE 1 - 3 (1) 6"∅ 4 - 6 (2) 6"∅The 6x12 products will no longer be used. EQUIPMENT H-FRAME DETAIL OR APPROVED EQUIVALENT NOTES: 1.MIN. DISTANCE FROM ANGLE EDGE TO U=BOLT HOLE IS 1-1/4" 2.ALL HOLES SHALL BE 9/16"∅ 3.ALL STEEL SHALL BE HOT DIPPED GALV. 4.FIELD DRILLED HOLES, FIELD CUTTING OF STEEL AND DAMAGED AREAS SHALL BE RETOUCHED WITH PG&E NO.56 ZINC PRIMER OR EQUIVALENT. 5.NEW BRACKET TO BE ATTACHED TO VALMONT MOUNT PART # B-1709.VARIES3'-6" (42") 5" 3'-0" MAX. ∠2x2x3/16 GALV. ASTM A36; TOP AND BOTTOM 1/2"x2-1/2"x4" GALV. U-BOLTS ASTM A36, TYP. SCH. 40 2" I.D. PIPE 1'-9 1/2"6"6"EQUIPMENT MOUNT AT TOWER LEG DETAIL OR APPROVED EQUIVALENT EXISTING TOWER LEG 2-3/8" O.D. PIPE 2-3/8" O.D. PIPE EXISTING TOWER LEG - BB - AA MANUFACTURER: MICROFLECT MODEL/PRODUCT NO.: B1709 DWG. NO.: B134909 WEIGHT: 65.0 LBS. N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: DETAILS A-6.1 N.T.S SCALE: 1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Licensor: Sheet Title: Sheet Number: Jurisdiction: Issued For: B 04/24/2025 95%CDs FOR REVIEW WM A 04/08/2025 90%CDs FOR REVIEW KP/WM REV DATE DESCRIPTION BY Prepared For: Engineer: 2840 HOWE ROAD, SUITE E MARTINEZ, CA 94553 www. TheCBRGroup.com Site Name: T-Mobile ID: OROVILLE QUINCY HWY PG&E NORTH TOWER CONSTRUCTION FOR OFFICIAL USE ONLY SCL0115C Site Address: 2867 ORO QUINCY HWY N.T.S SCALE:C:\Users\Wing Mok\Box\CBR General\T-MOBILE\T-Mobile Sites\SCL0115C\04 A&E\06 CAD\SCL0115C_A-6.dwg, 4/24/2025 11:15:48 AM XXXXXXX X X X X X X X XXXXXXXXXX XXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXX X X X X X XXXXXTYPICAL E-1 NOTE/S: 1.(N) T-MOBILE EQUIPMENT TO BE GROUNDED TO EXISTING GROUNDING BAR USING #2-AWG SOLID BARE TINNED COPPER WIRE UNLESS OTHERWISE NOTED. 2.(E) GROUND WIRES ARE NOT SHOWN FOR CLARITY. 3.TEST (E) SITE GROUND SYSTEM. REPORT ANY DEFICIENCIES TO ENGINEER FOR FURTHER INSTRUCTIONS. 4.ALL EXISTING ELECTRICAL EQUIPMENT THAT IS MODIFIED FOR NEW CIRCUIT RECONFIGURATION SHALL BE BROUGHT TO MEET CURRENT CODE REQUIREMENTS. 1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Licensor: Sheet Title: Sheet Number: Jurisdiction: Issued For: B 04/24/2025 95%CDs FOR REVIEW WM A 04/08/2025 90%CDs FOR REVIEW KP/WM REV DATE DESCRIPTION BY Prepared For: Engineer: 2840 HOWE ROAD, SUITE E MARTINEZ, CA 94553 www. TheCBRGroup.com Site Name: T-Mobile ID: OROVILLE QUINCY HWY PG&E NORTH TOWER CONSTRUCTION FOR OFFICIAL USE ONLY SCL0115C Site Address: 2867 ORO QUINCY HWY 120°240° 0°NORTHMAG.16°30' 2 PROPOSED GROUNDING PLAN - ANTENNA AREA 0'4'2' SCALE: 3/8" = 1'-0" 8'6' GENERAL ELECTRICAL NOTES 1.ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL ANY/ALL ELECTRICAL WORK INDICATED. ANY/ALL CONSTRUCTION SHALL BE IN ACCORDANCE W/DRAWINGS AND ANY/ALL APPLICABLE SPECIFICATIONS. IF ANY PROBLEMS ARE ENCOUNTERED BY COMPLYING WITH THESE REQUIREMENTS, CONTRACTOR SHALL NOTIFY 'CONTRACTOR MANAGER' AS SOON AS POSSIBLE, AFTER THE DISCOVERY OF THE PROBLEMS, AND SHALL NOT PROCEED WITH THAT PORTION OF WORK, UNTIL THE 'CONSTRUCTION MANAGER' HAS DIRECTED THE CORRECTIVE TO BE TAKEN. 2.ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE AND THEMSELF WITH ANY/ALL CONDITIONS AFFECTING ELECTRICAL AND COMMUNICATION INSTALLATION AND MAKE PROVISIONS AS TO COST THEREOF. ALL EXISTING CONDITIONS OF ELECTRICAL EQUIP., LIGHT FIXTURES, ETC., THAT ARE PART OF THE FINAL SYSTEM, SHALL BE VERIFIED BY THE CONTRACTOR, PRIOR TO THE SUBMITTING OF HIS BID, FAILURE TO COMPLY WITH THIS PARAGRAPH WILL IN NO WAY RELIEVE CONTRACTOR OF PERFORMING ALL WORK NECESSARY FOR A COMPLETE AND WORKING SYSTEM. 3.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE CEC AND ALL CODES AND LOCAL ORDINANCES OF THE LOCAL POWER & TELEPHONE COMPANIES HAVING JURISDICTION AND SHALL INCLUDE BUT NOT LIMITED TO: A.UL - UNDERWRITERS LABORATORIES B.CEC - CALIFORNIA ELECTRICAL CODE C.NEMA - NATIONAL ELECTRICAL MANUFACTURERS ASSOC. D.OSHA - OCCUPATIONAL SAFETY AND HEALTH ACT E.CBC - CALIFORNIA BUILDING CODE 4.DO NOT SCALE ELECTRICAL DRAWINGS, REFER TO SITE PLANS AND ELEVATIONS FOR EXACT LOCATION OF ALL EQUIPMENT, AND CONFIRM WITH 'CONSTRUCTION MANAGER' ANY SIZES AND LOCATIONS WHEN NEEDED. 5.EXISTING SERVICE: CONTRACTOR SHALL NOT INTERRUPT EXISTING SERVICE WITHOUT WRITTEN PERMISSION OF THE OWNER. 6.CONTRACTOR SHALL PAY FOR ANY/ALL PERMITS, FEES, INSPECTIONS AND TESTING. CONTRACTOR IS TO OBTAIN PERMITS AND APPROVED SUBMITTALS PRIOR TO THE WORK BEGINNING OR ORDERING EQUIPMENT. 7.THE TERM "PROVIDE" USED IN CONSTRUCTION DOCUMENTS AND SPECIFICATIONS, INDICATED THAT THE CONTRACTOR SHALL FURNISH AND INSTALL. 8.CONTRACTOR SHALL CONFIRM WITH LOCAL UTILITY COMPANY ANY/ALL REQUIREMENTS. ANY/ALL CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER, PRIOR TO BEGINNING ANY WORK 9.MINIMUM WIRE SIZE SHALL BE #12 AWG, NOT INCLUDING CONTROL WIRING, UNLESS NOTED OTHERWISE. ALL CONDUCTORS SHALL BE COPPER WITH THWN INSULATION. 10.OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET/DAMP LOCATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS. 11.IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF THE CONSTRUCTION. CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS FOR THE EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. 12.ELECTRICAL SYSTEM SHALL BE AS COMPLETELY AND EFFECTIVELY GROUNDED, AS REQUIRED BY SPECIFICATIONS, SET FORTH BY CLIENT OR WIRELESS CARRIER. 13.ALL WORK SHALL BE PERFORMED BY LICENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS, WORKMANLIKE MANNER, THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE AND SUBJECT TO REGULATORY INSPECTION AND APPROVAL BY CONSTRUCTION MANAGER. 14.ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. 15.CONTRACTOR SHALL GUARANTEE ANY/ALL MATERIALS AND WORK FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE YEAR FROM THE DAY OF FINAL ACCEPTANCE. 16.THE CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ANY ADDITIONAL CHARGE AND SHALL INCLUDE THE REPLACEMENT OR THE REPAIR OF ANY OTHER PHASE OF THE INSTALLATION, WHICH MAY BEEN DAMAGED THEREIN. 17.ADEQUATE AND REQUIRED LIABILITY INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LOSS AND ANY/ALL PROPERTY DAMAGE FOR THE DURING OF WORK. 18.PROVIDE AND INSTALL CONDUIT, CONDUCTORS, PULL WIRES, BOXES, COVER PLATES AND DEVICES FOR ALL OUTLETS AS INDICATED. 19.DITCHING AND BACK FILL: CONTRACTOR SHALL PROVIDE FOR ALL UNDERGROUND INSTALLED CONDUIT AND/OR CABLES INCLUDING EXCAVATION AND BACKFILLING AND COMPACTION. REFER TO NOTES AND REQUIREMENTS, EXCAVATION, AND BACKFILLING. 20.MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW AND SHALL APPEAR ON LIST OF U.L. APPROVAL ITEMS AND SHALL MEET OR EXCEED THE REQUIREMENTS OF THE CEC AND NEMA. 21.CONTRACTOR SHALL SUBMIT SHOP DRAWING OR MANUFACTURERS CATALOG INFORMATION OF ANY/ALL LIGHTING FIXTURES, SWITCHES AND ALL OTHER ELECTRICAL ITEMS FOR APPROVAL BY THE CONSTRUCTION MANAGER PRIOR TO INSTALLATION. 22.ANY CUTTING OR PATCHING DEEMED NECESSARY FOR ELECTRICAL WORK IS THE ELECTRICAL CONTRACTOR RESPONSIBILITY AND SHALL BE INCLUDED IN THE COST FOR WORK AND PERFORMED TO THE SATISFACTION OF THE 'CONSTRUCTION MANAGER' UPON FINAL ACCEPTANCE. 23.THE ELECTRICAL CONTRACTOR SHALL LABEL ALL PANELS WITH ONLY TYPEWRITTEN DIRECTORIES. ALL ELECTRICAL WIRING SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 24.DISCONNECT SWITCHES SHALL BE H.P. RATED HEAVY-DUTY, QUICK-MAKE AND QUICK-BREAK ENCLOSURES, AS REQUIRED BY EXPOSURE TYPE. 25.ALL CONNECTIONS SHALL BE MADE WITH A PROTECTIVE COATING OF AN ANTI-OXIDE COMPOUND SUCH AS "NON-OXIDE A" BY DEARBORNE CHEMICAL CO. COAT ALL WIRE SURFACES BEFORE CONNECTING . EXPOSED COPPER SURFACES, INCLUDING GROUND BARS, SHALL BE TREATED - NO SUBSTITUTIONS. 26.RACEWAYS: CONDUIT SHALL BE SCHEDULE 40 PVC MEETING OR EXCEEDING NEMA TC2 - 2020. CONTRACTOR SHALL PLUG AND CAP EACH END OF SPARE AND EMPTY CONDUITS AND PROVIDE TWO SEPARATE PULL STRINGS - 200 LBS TEST POLYETHYLENE CORD. ALL CONDUIT BENDS SHALL BE A MINIMUM OF 2 FT. RADIUS RGS CONDUITS WHEN SPECIFIED, SHALL MEET UL-6 FOR GALVANIZED STEEL . ALL FITTINGS SHALL BE SUITABLE FOR USE WITH THREADED RIDGE CONDUIT. COAT ALL THREADS WITH 'BRITE ZINC' OR ' GOLD GALV' 27.SUPPORT OF ALL ELECTRICAL WORK SHALL BE AS REQUIRED BY CEC. 28.CONDUCTORS: CONTRACTOR SHALL USE 98% CONDUCTIVITY COPPER TYPE THWN. INSULATION, 800 VOLT, COLOR CODED, USE SOLID CONDUCTORS FOR WIRE UP TO AND INCLUDING NO. 8 AWG. USE STRANDED CONDUCTORS FOR WIRE ABOVE NO. 8 AWG. 29.CONNECTORS FOR POWER CONDUCTORS, CONTRACTORS SHALL USE PRESSURE TYPE INSULATED TWIST-ON CONNECTORS FOR NO.10 AWG AND SMALLER USE SOLDERLESS MECHANICAL. TERMINAL LUGS FOR NO. 8 AWG AND LARGER. 30.SERVICE: 120/240V, SINGLE PHASE, 3 WIRE CONNECTION AVAILABLE FROM UTILITY COMPANY. OWNER OR OWNERS AGENT WILL APPLY FOR POWER. 31.TELEPHONE SERVICE: CONTRACTOR SHALL PROVIDE EMPTY CONDUITS WITH PULL STRINGS AS INDICATED ON DRAWINGS. 32.ELECTRICAL AND TELCO RACEWAYS TO BE BURIED A MINIMUM OF 2' DEPTH. 33.CONTRACTOR SHALL PLACE TWO LENGTHS OF WARNING TAPE AT A DEPTH OF 12" BELOW GROUND AND DIRECTLY ABOVE ELECTRICAL, AND TELCO SERVICE CONDUITS. CAUTIONS TAPE TO READ "CAUTION BURIED ELECTRIC" OR "BURIED TELECOMM". 34.ALL BOLTS SHALL BE STAINLESS STEEL. 1 PROPOSED GROUNDING PLAN - EQUIPMENT AREA 120°240° 0°NORTH MAG.16°30'0'4'2' SCALE: 3/8" = 1'-0" 8'6' TYPICAL E-1 NOTE/S: 1.(N) WIRELESS CARRIER EQUIPMENT TO BE GROUNDED TO EXISTING GROUNDING BAR USING #2-AWG SOLID BARE TINNED COPPER WIRE UNLESS OTHERWISE NOTED. 2.(E) GROUND WIRES ARE NOT SHOWN FOR CLARITY. 3.TEST (E) SITE GROUND SYSTEM. REPORT ANY DEFICIENCIES TO ENGINEER FOR FURTHER INSTRUCTIONS. 4.ALL EXISTING ELECTRICAL EQUIPMENT THAT IS MODIFIED FOR NEW CIRCUIT RECONFIGURATION SHALL BE BROUGHT TO MEET CURRENT CODE REQUIREMENTS. ELECTRICAL NOTES, AND GROUNDING PLAN/S E-1 (N) 2-AWG T-MOBILE GROUND WIRE; DIRECTLY CONNECTED TO THE TOWER USING BEAM CLAMP, TYP. E-2 6 (N) 6160 CABINET (N) B160 CABINET (N) CIENA BOX WITH (N) FIBER BOX BELOW (N) UNISTRUT-MOUNTED LED WORK LIGHT (N) 200A PPC CABINET WITH (N) CAM-LOCK BOX (N) 200A METER PANEL (N) NEMA3R-RATED HCS WINDER BOX A-6 11 (N) PORTABLE FIRE EXTINGUISHER E-3 12 (N) CHAIN-LINK FENCE ENCLOSURE (N) CONCRETE SLAB (N) 3'-0" WIDE ACCESS GATE (N) GPS ANTENNA A-6 12 E-3 9 E-3 10 E-3.1 4 (E) TOWER LEG (E) TOWER BASE (E) CONCRETE SLAB (E) PG&E TOWER (N) T-MOBILE ANTENNA APXVAALL18M-U-J20, TYP. (N) T-MOBILE ANTENNA AIR 6419 B41, TYP. (N) T-MOBILE RADIO 4460 B25+B66, TYP. (N) T-MOBILE RADIO 4480 B71+B85, TYP. E-3 8 (N) T-MOBILE GROUND BAR CONNECT TO (E) NEAREST GROUND SOURCE E-3 4 (N) T-MOBILE GROUND WIRE, TYP. CONNECT TO (N) GROUND BAR E-3 4 E-3 5 (2)(N) TMAs, TYP.C:\Users\Wing Mok\Box\CBR General\T-MOBILE\T-Mobile Sites\SCL0115C\04 A&E\06 CAD\SCL0115C_E-1.dwg, 4/24/2025 11:15:55 AM N.T.S.1 SINGLE LINE DIAGRAM N.T.S.2 EXISTING PANEL SCHEDULE WITH NEW LOAD NOTES: 1.ALL SERVICE EQUIPMENT AND INSTALLATIONS SHALL COMPLY WITH NEC, UTILITY COMPANY AND LOCAL CODE REQUIREMENTS. 2.WIRES TO END OF FLEXIBLE NONMETALLIC CONDUIT. COIL 3'-0" AT END OF FLEXIBLE NONMETALLIC CONDUIT & TAG. 3.PULL ONE GROUND CONDUCTOR PER FLEXIBLE NONMETALLIC CONDUIT. FOR ALL OTHER CIRCUITS PULL A SEPARATE CONDUCTOR. 4.ALL GFCI RECEPTACLES TO HAVE A DEDICATED GROUND WIRE. 5.EQUIPMENT TERMINATION LUGS AND CONDUCTORS ARE RATED AT A MINIMUM OF 75°C. 6.KAIC OF NEW BREAKER (S) TO MATCH EXISTING. 7.CONTRACTOR TO VERIFY NUMBER AND SIZE OF ALL CIRCUITS REQUIRED WITH T-MOBILE PRIOR TO START CONSTRUCTION. FUSE FOR SPLIT-PHASE FEEDING 2W + PE AMOUNT OF RECTIFIERS INPUT CURRENT (A)RECOMMENDED AC FUSE (A) 1 18 25 2 36 50 3 54 80 4 72 100 5 90 125 6 100 125 7 126 150 8 144 175 9 162 200 1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Licensor: Sheet Title: Sheet Number: Jurisdiction: Issued For: B 04/24/2025 95%CDs FOR REVIEW WM A 04/08/2025 90%CDs FOR REVIEW KP/WM REV DATE DESCRIPTION BY Prepared For: Engineer: 2840 HOWE ROAD, SUITE E MARTINEZ, CA 94553 www. TheCBRGroup.com Site Name: T-Mobile ID: OROVILLE QUINCY HWY PG&E NORTH TOWER CONSTRUCTION FOR OFFICIAL USE ONLY SCL0115C Site Address: 2867 ORO QUINCY HWY CONSTRUCTION NOTES: 1.CONTRACTOR TO COORDINATE WITH PG&E TO VERIFY IF MISSING, REPLACE THE CONDUIT FEEDING POWER TO THE SMARTMETER TO CONDUIT TO 3". 2.AC IS CONVERTED TO DC WITH RECTIFIERS IN 6160 CABINET. BATTERIES FEED DC EQUIPMENT AND DEVICES ONLY AND DOES NOT BACKFEED AC POWER SYSTEM. ALT. SOURCE 2P/200A MECHANICAL INTERLOCK SEE CONSTRUCTION NOTE #4 (N) CAM-LOCK GENERATOR CONNECTOR 120/240, 1∅, 3W, 200A (N)LIGHT(N)GFI(N) 1P 15A (N) 1P 20A NORMAL SOURCE 2P/200A±15FT.VD=0.05%(N) PPC CABINET NEAR EQUIPMENT AREA (N)TVSS(N) 2P 60A (N) 3#3/0 + 1#4 GND (N)3/4" CONDUIT (2#12 + 1#12 GND) (N) CONDUIT/CONDUCTORS PER MANUFACTURER RECOMMENDATIONS (N) B160 BATTERY CABINET (N) 2P 125A (N) RBS 6160 CABINET (6)(N) RECTIFIERS (2)(N) 2" CONDUIT TO BE INSTALLED PER T-MOBILE/MANUFACTURER INSTALLATION GUIDELINES ±16FT.(N) 2" CONDUIT (2#1 + 1#2 GND) (N) 3" CONDUIT CONDUCTORS TO BE INSTALLED BY PG&E (N) 200A PG&E SMARTMETER M (N) 200A BREAKER (N) 2-1/2" CONDUIT (3#3/0 + 1#4 GND) LOAD LOAD PER PHASE (VA)TRIP LOAD PER PHASE (VA)LOAD DESCRIPTION POLE PHASE PHASE POLE DESCRIPTIONABAB 1 (N) RBS CABINET 6160 2 10500 125 60 0 2 (N) TVSS 2 3 10500 0 4 5 (N) GFI 1 180 20 6 7 (N) LIGHT 1 200 15 8 9 10 11 12 SUBTOTAL CONTINUOUS 10500 10700 0 0 SUBTOTAL CONTINUOUS TOTAL VA CONTINUOUS (x 1.25)26500 SUBTOTAL NON-CONTINUOUS 180 0 0 0 SUBTOTAL NON-CONTINUOUS TOTAL VA NON-CONTINUOUS 180 PANEL DESIGNATION: ELECTRICAL PANEL (ITEM 1)MAIN LUGS: N/A MAIN BREAKER:200 AMPS CYCLE:60 VOLTAGE:120/240 TOTAL VA 26680 MAIN BREAKER A.I.C. RATING:65,000 A.I.C.PHASE:1 BRANCH BREAKER SERIES A.I.C. RATING:10,000 A.I.C.WIRES:3 NEUTRAL:200 AMPS TOTAL AMPS 111.2BRANCH BREAKER TYPE:-MAIN COPPER BUS:200 AMPS (E) PG&E UNDERGROUND SERVICE 120/240V 3PH 4W (N) METER PANELSINGLE LINE DIAGRAM, AND PANEL SCHEDULE E-2 C:\Users\Wing Mok\Box\CBR General\T-MOBILE\T-Mobile Sites\SCL0115C\04 A&E\06 CAD\SCL0115C_E-2.dwg, 4/24/2025 11:15:59 AM MANUFACTURER: STRIKE FIRST USA MODEL: HDOC-10 HEIGHT: 25.0" WIDTH: 12.0" WEIGHT: 30 LBS. (NET) FINISH: BAKED RED ENAMEL NOTE: FIRE EXTINGUISHER SOLD SEPARATELY USE MANUFACTURER SUPPLIED MOUNTING HARDWARE FIRE EXTINGUISHER CABINET DETAIL OR APPROVED EQUIVALENT 12.0"25.0"INCLUDED RED DECAL 'PULL FIRMLY TO OPEN' INCLUDED WHITE DECAL 'FIRE EXTINGUISHER' 200A METER PANEL DETAIL MANUFACTURER: EATON MODEL: U224MTB TYPE: RING MAIN AMPERE RATING: 200A HEIGHT: 30.0" WIDTH: 22.0" DEPTH:6.0" WEIGHT: 54.0 LBS. NOT USEDNOT USEDNOT USEDCAM-LOCK GENERATOR CONNECTOR DETAIL MANUFACTURER: INTERSECT MODEL: ICGC-3P-400-CBL CONNECTOR TYPE: MALE AMPERE RATING: RATED UP TO 400A, 208/120V, 3∅ (MAY BE USED FOR 240/120 1∅ APPLICATIONS) HEIGHT: 23.0" WIDTH: 10.0" DEPTH:9.5" APPROX. WEIGHT: 14.0 LBS. PPC CABINET DETAIL MANUFACTURER: VERTIV AC MODEL: CACA75214090 HEIGHT: 39.0" WIDTH: 20.0" DEPTH:10.0" WEIGHT (APPROX.): 75.0 LBS.10"ELECTRICAL INFO: OPERATING VOLTAGE: 240/120, SINGLE PHASE AMPERAGE: 200 AMP UTILITY/STANDBY (SQUARE D BREAKERS) AIC RATING:200 AMP - 65,000 AIC (SERIES) LOAD CENTER:30 POSITION 2-2P 200A BREAKER/S 1-2P 125A BREAKER/S 1-2P 60A BREAKER/S 1-1P 20A BREAKER/S 1-1P 15A BREAKER/S 20.0"39.0"PPC WITH GENERATOR PLUG DETAIL ALSO AVAILABLE DETAIL_ELEC_PPC.DWG GROUND BAR CONNECTION DETAIL NOTE: 1.CONTRACTOR TO UTILIZE KOPR-SHIELD (THOMAS & BETTS) ON ALL LUG CONNECTIONS OR APPROVED EQUAL 2.ALL LUGS TO BE DUAL HOLE LONG BARREL AND CRIMPED TWICE WITH MANUFACTURERS RECOMMENDED TOOL SILICON SEAL AT TOP #2 AWG FROM EQUIPMENT TO BE GROUNDED GROUND BAR DUAL CALDWELDS TO BE USED WITH #2 AWG BCW TO GROUND RING 1' OVC SEALTITE GROUND BAR DETAIL 2 3/4" 5 1" 4 7/16" 3 2" NOTES/LEGEND: 1.COPPER GROUND BAR, "X 1/4"X 20", NEWTON INSTRUMENT CO. CAT. NO. B-6142 OR EQUAL. HOLE CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION. (ACTUAL GROUND BAR SIZE WILL VARY BASED ON NUMBER OF GROUND CONNECTIONS) 2.INSULATORS, NEWTON INSTRUMENT CAT. NO. 3061-4 OR EQUAL 3.5/8" LOCKWASHER, NEWTON INSTRUMENT CO. CAT. NO. 3015-8 OR EQUAL 4.WALL MOUNTING BRACKET, NEWTON INSTRUMENT CO. CAT NO. A-6056 OR EQUAL 5.5/8-11 X 1" HHCS BOLTS, NEWTON INSTRUMENT CO. CAT NO. 3012-1 OR EQUAL 6.INSULATORS SHALL BE ELIMINATED WHEN BONDING DIRECTLY TO TOWER/MONOPOLE STRUCTURE. CONNECTION TO TOWER/MONOPOLE STRUCTURE SHALL BE PER MANUFACTURERS RECOMMENDATIONS. NOTE: ALL HARDWARE SHALL BE STAINLESS STEEL EXOTHERMIC WELD CONNECTION TYPE VB TYPE VS TYPE GL LUGTYPE XA TYPE GR TYPE PG TYPE LJ TYPE HA TYPE GT TYPE SS TYPE TA TYPE PC TYPE RR TYPE NDTYPE NX1 TYPE GY TYPE NC TYPE PH TYPE GR N.T.S SCALE: N.T.S SCALE:MECHANICAL CONNECTION BOLT GROUND ROD CLAMP 2-BOLT PARALLEL SPLICER CROSS RUN CLAMP UNIVERSAL PIPE CLAMP 75/1.25 2-HOLE LUG CAST 'T' SPLICER 1-BOLT PARALLEL CLAMP U-BOLT PIPE CLAMP 1-BOLT PARALLEL CLAMP UNIVERSAL PIPE CLAMP 50H2 1.ALL HARDWARE 18-8 STAINLESS STEEL, INCLUDING LOCK WASHES, COAT ALL SURFACES WITH AN ANTI-OXIDANT COMPOUND BEFORE MATING. ALL HARDWARE SHALL BE STAINLESS STEEL 3/8 INCH DIAMETER OR LARGER. 2.FOR GROUND BOND TO STEEL ONLY: INSERT A CADMIUM FLAT WASHER BETWEEN LUG AND STEEL, COAT ALL SURFACES WITH AN ANTI-OXIDANT COMPOUND BEFORE MATING. 3.WHEN THE SCOPE OF WORK REQUIRES THE ADDITION OF A GROUNDING BAR TO AN EXISTING TOWER, THE SUBCONTRACTOR SHALL OBTAIN APPROVAL FROM THE TOWER OWNER PRIOR TO MOUNTING THE GROUNDING BAR TO THE TOWER. 4.ALL DETAILS ARE SHOWN ON GENERAL TERM, ACTUAL GROUNDING INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. 5.GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METALLIC COMPONENTS USING #2 GROUND WIRES AND CONNECT TO SURFACE MOUNTED GROUND BUS BARS AS SHOWN. FOLLOW ANTENNA AND BTS MANUFACTURER'S PRACTICES FOR GROUNDING REQUIREMENTS. GROUND COAX SHIELD AT BOTH ENDS USING MANUFACTURERS PRACTICES. ALL UNDERGROUND WATER PIPES, METAL CONDUITS AND GROUNDS THAT ARE A PART OF THIS SYSTEM SHALL BE BONDED TOGETHER. 6.CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE, 5 OHMS MAXIMUM. PROVIDE SUPPLEMENT GROUNDING RODS AS REQUIRED TO ACHIEVE SPECIFIED OHMS READING. GROUNDING AND OTHER OPTIONAL TESTING WILL BE WITNESSED BY THE T-MOBILE REPRESENTATIVE. 7.NOTIFY ENGINEER OF RECORD IF THERE ARE ANY DIFFICULTIES INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. 8.BARE GROUNDING CONDUCTOR SHALL BE HARD DRAWN TINNED COPPER SIZES AS NOTED ON PLAN. 9.ALL HORIZONTALLY RUN GROUNDING CONDUCTORS SHALL BE INSTALLED MINIMUM 12" BELOW GRADE/FROST-LINE IN TRENCH, U.N.O., AND BACK FILL SHALL BE COMPACTED AS REQUIRED BY ARCHITECT. 10.ALL GROUND CONDUCTORS SHALL BE RUN AS STRAIGHT AND SHORT AS POSSIBLE, WITH A MINIMUM 12" BENDING RADIUS NOT LESS THAN 90 DEGREES. 11.ALL SUPPORT STRUCTURES, CABLE CHANNEL WAYS OR WIRE GUIDES SHALL BE BONDED TO GROUND SYSTEM AT A POINT NEAREST THE MAIN GROUNDING BUS "MGB" (OR DIRECTLY TO GROUND-RING). 12.ACCEPTABLE CONNECTIONS FOR GROUND SYSTEM SHALL BE: a.BURNDY, HY-GRADE U.L. LISTED CONNECTORS FOR INDOOR USE OR AS APPROVAL BY T-MOBILE. b.CADWELD, EXOTHERMIC WELD (WELDED CONNECTIONS) c.TWO - (2) HOLE TINNED COPPER COMPRESSION (LONG BARREL) FITTINGS (BUS BAR CONNECTIONS). 13.ALL CRIMPED CONNECTIONS SHALL HAVE EMBOSSED MANUFACTURER'S DIEMARK VISIBLE AT THE CRIMP (RESULTING FROM USE OF PROPER CRIMPING DEVICE). PRIOR TO ANY LUG-BUSSBAR CONNECTIONS, THE BUSSBAR SHALL BE CLEANED BY USE OF "SCOTCH-BRITE" OR PLAIN STEEL WOOL AS TO REMOVE ALL SURFACE OXIDATION AND CONTAMINANTS. A COATING OF "NO-OX-ID" SHALL BE APPLIED TO THE CONNECTION SURFACES. ALL CONNECTION HARDWARE SHALL BE TYPE 316 SS (NOT ATTRACTED TO MAGNETS). 14.ELECTRICAL SERVICE EQUIPMENT GROUNDING SHALL COMPLY WITH CEC AND SHALL BOND ALL EXISTING AND NEW GROUNDING ELECTRODES. NEW GROUNDING ELECTRODE SHALL INCLUDE BUT NOT LIMITED TO GROUND RODS, GROUND RING IF SERVICE IS WITHIN THE RADIO EQUIPMENT LOCATION, BUILDING STEEL IF APPLICABLE, COLD WATER CONNECTIONS MUST BE MADE ON THE STREET SIDE OF MAIN SHUT-OFF VALVE. 15.ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL GROUNDING INSTALLATION REQUIREMENTS AND CONSTRUCTION ACCORDING TO SITE CONDITIONS. 16.ALL GROUNDING CONDUCTORS: #2 AWG SOLID BARE TINNED COPPER WIRE UNLESS OTHERWISE NOTED. 17.GROUND BAR LOCATED IN BASE OF EQUIPMENT WILL BE PROVIDED, FURNISHED AND INSTALLED BY THE VENDOR. 18.GROUND RING SHALL BE LOCATED A MINIMUM OF 24" BELOW GRADE OR 6" MINIMUM BELOW THE FROST LINE. 19.INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1'-0" FROM EQUIPMENT CONCRETE SLAB, SPREAD FOOTING, OR FENCE. 20.EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLD GALVANIZED SPRAY. 21.GROUND BARS: A. EQUIPMENT GROUND BUS BAR (EGB) LOCATED AT BOTTOM OF ANTENNA POLE/MAST FOR MAKING GROUNDING JUMPER CONNECTIONS TO COAX FEEDER CABLES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. JUMPERS (FURNISHED BY OWNERS) SHALL BE INSTALLED AND CONNECTED BY ELECTRICAL CONTRACTOR. B. MAIN GROUND BUS BAR (MGB) LOCATED NEAR THE BASE OF THE RADIO EQUIPMENT CABINET(S) SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. 22.ALL GROUNDING INSTALLATIONS AND CONNECTIONS SHALL BE MADE BY ELECTRICAL CONTRACTOR. 23.FOLLOW C.E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE GROUNDING. 24.GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS OR AT GROUNDING POINTS PROVIDED (2 MINIMUM). 25.IF EQUIPMENT IS IN A C.L. FENCE ENCLOSURE, GROUND ONLY CORNER POSTS AN`D SUPPORT POSTS OG GATE. IF CHAIN LINK LID IS USED, THEN GROUND LID ALSO. 26.GROUNDING @ PPC CABINET SHALL BE VERTICALLY INSTALLED. 27.ALL GROUNDING FOR ANTENNAS SHALL BE CONNECTED SO THAT IT WILL BY-PASS MAIN BUSS BAR. 28.ALL EMT RUNS SHALL BE GROUNDED AND HAVE A BUSHING. NO PVC ABOVE GROUND. 29.USE SEPARATE HOLES FOR GROUNDING @ BUSS BAR. NO "DOUBLING-UP" OF LUGS. 30.POWER AND TELCO CABS SHALL BE GROUNDED (BONDED) TOGETHER. 31.NO "L AND B" ALLOWED ON GROUNDING. 32.PROVIDE STAINLESS STEEL CLAM AND BRASS TAGS ON COAX @ ANTENNAS AND DOGHOUSE. N.T.S.1 GROUNDING NOTES N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: ELECTRICAL DETAILS E-3 1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Licensor: Sheet Title: Sheet Number: Jurisdiction: Issued For: B 04/24/2025 95%CDs FOR REVIEW WM A 04/08/2025 90%CDs FOR REVIEW KP/WM REV DATE DESCRIPTION BY Prepared For: Engineer: 2840 HOWE ROAD, SUITE E MARTINEZ, CA 94553 www. TheCBRGroup.com Site Name: T-Mobile ID: OROVILLE QUINCY HWY PG&E NORTH TOWER CONSTRUCTION FOR OFFICIAL USE ONLY SCL0115C Site Address: 2867 ORO QUINCY HWY NOT USED C:\Users\Wing Mok\Box\CBR General\T-MOBILE\T-Mobile Sites\SCL0115C\04 A&E\06 CAD\SCL0115C_E-3.dwg, 4/24/2025 11:16:02 AM MANUFACTURER: CIENA MODEL: 3931 HEIGHT: 17.0" WIDTH: 16.8" DEPTH:7.0" WEIGHT: 28.6 LBS. (NET) CIENA BOX DETAIL17.0"16.8"7.0" GROUND RING TRENCH DETAIL FINISHED GRADE CONTINUOUS GROUND RING, SIZED PER GROUNDING DETAIL30" OR 6" BELOW FROST LINE,WHICHEVER IS GREATERCONTINUOUS WARNING TAPE 6"12"6" MIN. COMPACTED EARTH BACKFILL GROUND ROD DETAIL FINISHED GRADE #2-AWG BCW GROUND RING 10'-LONG X 5/8"∅ COPPER-CLAD STEEL GROUND ROD30"CALDWELD CONNECTION NOT USEDINSPECTION WELL DETAIL FINISHED GRADE 1'-6"12" MAX8" INSIDE DIA PRE-CAST CONCRETE WELL WITH NON-CONDUCTIVE LID OR APPROVED EQ. GROUND ROD, 10' X 5/8" LONG COPPER CLAD STEEL 3/4" CRUSHED STONE OR EQ.; FILL TEST WELL JUST BELOW THE TOP OF T-CONNECTOR DMC T-CONNECTOR 250 MCM BARE COPPER WIRE (B.C.W.) PIGTAIL FOR EMERGENCY GENERATOR CONNECTION 250 MCM B.C.W. CONNECTED BACK TO SITE GROUND GRID FOR PG&E TOWERS, USE THIS DETAIL NOT USED 1200 CONCORD AVENUE, SUITE 500 CONCORD, CA 94520 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Licensor: Sheet Title: Sheet Number: Jurisdiction: Issued For: B 04/24/2025 95%CDs FOR REVIEW WM A 04/08/2025 90%CDs FOR REVIEW KP/WM REV DATE DESCRIPTION BY Prepared For: Engineer: 2840 HOWE ROAD, SUITE E MARTINEZ, CA 94553 www. TheCBRGroup.com Site Name: T-Mobile ID: OROVILLE QUINCY HWY PG&E NORTH TOWER CONSTRUCTION FOR OFFICIAL USE ONLY SCL0115C Site Address: 2867 ORO QUINCY HWY N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S SCALE: ELECTRICAL DETAILS E-3.1 C:\Users\Wing Mok\Box\CBR General\T-MOBILE\T-Mobile Sites\SCL0115C\04 A&E\06 CAD\SCL0115C_E-3.dwg, 4/24/2025 11:16:03 AM