HomeMy WebLinkAbout047-320-065 Onsite System Evaluation and Maintenance Report 25 Felicidad 2025Site Address: Owner: Mailing: Owners Phone: Evaluator:for Hydrotec Tank Volume:Gals.24 Inches X Yes No X Good Fair Poor High X Normal Low X Good Fair Poor X Yes No N/A Scum:4 Inches Sludge:6 Inches Yes No X N/A Scum:3 Inches Sludge:4 Inches X Good Fair Poor N/A Yes X No Yes X No X Yes No X Yes No X Good Poor X Yes No Alarms: X Audible X Visual EC ETM HLA OVR Yes X No Hydraulic Load Test:Excellent Good Poor X X Dry Ponding N/A Yes X No Yes X No Yes X No Yes X No Yes X No Yes X No Comments and System Map on Back ]HS,I-STEP8/11 Satisfactory Pump to Gravity 11.7 Marginal Graywater: Surfacing Effluent: Effluent Line D.Valve: Type of Absorption Field: Well on Property: N/A Date Tank (s) Previously Pumped: Type of Filter: N/A Running Voltage: Biotube Bacteria Action: 119.3 HYDROTEC SOLUTIONS P.O. Box 7908, Chico, CA 95927 (530) 891-4420, FAX: (530) 891-4426 Residential Supplemental Treatment Onsite System Evaluation and Maintenance Report Same 7/7/25 R. Belcher 530-521-8681 Down Slope Seepage: Saturated Field: # Occupants: Multiple Systems: Pump: N/APump:N/A Piezometers: FAILURE Not Applicable Running AMPS: Control Panel: Depth to Access Lid: N/A 25 Felicidad Ln., Chico, CA 95973 S.T.E.P. System Eval. Date: Larry McDonald All Floats Operating? Tank was Cleaned: Tank Material:Concrete Pump, Vault & Filter Cleaned? Inlet Tee: Outlet Tee: Baffle Condition: Pumping Required: 1500 Condition: Structural Condition: Access Risers: Liquid Operating Level: SEPTIC TANK: ABSORPTION TRENCHES: Evaluator Signature Date: N k DRIVEWAY TANK->P I O F x E PANEL ^ L W I A C L POOL I K D W HOUSE A A D Y L A N E DRIVEWAY 25 Felicidad Ln. HS,I-STEP8/11 PARCEL ADDRESS: We found no problems at this time. LOCATION OF SEPTIC TANK & ABSORPTION FIELD 7/7/25 I certify that this onsite wastewater treatment and disposal system evaluation report reflects conditions observed on the parcel (s) during the routine maintenance of the onsite wastewater treatment and disposal system. R. Belcher KEEFER RD. COMMENTS / OBSERVATIONS replaced as well, even though it was not bad. Rewired J-Box. We found no other problems at this time. This onsite wastewater treatment and disposal system evaluation report is a true and complete record of the onsite waste- water treatment and disposal system on the date of the evaluation. No warranty is given or implied regarding the remaining life of this system. Replaced both the "On" and "Off" floats. Customer asked to have the "High-Level" float