Loading...
HomeMy WebLinkAboutFAI15-0099 022-320-001 Biggs Elem FA 11.1.24 ALARM AND DETECTION REPORT Page 1 of 8 VOLTAG PECIALisTs 530-624-4514 C101C16 License#880862 www.VoltageSpecialists.com Inspection # ALARM & DETECTION EQUIPMENT TEST REPORT Type of Inspection: Annual Date: 11/1/24 site: Biggs Elementary School Customer: Biggs USD Street: 300 B Street Contact: John Strattard City/State: Biggs, California Phone#: 530-868-1281 Fax#: 1. Before Test Notify Proper Authorities: Name Phone # A. Owner or Owner's Rep John Strattard 530-868-1281 B. Fire Department C. Central Station Central Station 1-800-722-0364 D. Central Station Acct# 18-9479 2. Control Panel Status Yes No Note # A. Is the system monitored by Central Station? X On Test Time: 3:00 Return to Service Time: 9:00 B. Is the Power Light on? X C. Does the Panel indicate Normal conditions? X D. Are all indicating Lamp Bulbs in Operator order? X E. Does the Trouble Light operate? X F. Does the Silence Switch Operate? X G. Battery A.H. 18 Date Batteries Installed: 6/19/2020 1-1. Does the Panel have Non-Operational Zones? X I. Does the Panel have Battery Backup? X J. Do the batteries indicate they are Properly Charged? X Condition of Batteries: Good Note# Battery Voltage with AC Power: 27.43 Battery Voltage without AC Power: 27.40 K. List any trouble conditions on panel before test: Note# Note# Comments: Note# Note# 3. FACP Manufacturer: Silent Knight Model# 6820EVS System Type: Addressable Location of Annunciators: Location of Primary Power Source: Panel# Breaker Comments: Note# Note# FCPS: Manufacturer: Silent Knight Model# EVS-100W Panel/Breaker# Location:Gym Storage 8Ah Battery Voltage with A/C Power: 27.22 w/o A/C Power 27.19 Date: 9/15/2022 FCPS: Manufacturer: Silent Knight Model# 5895XL Panel/Breaker# Location:Gym Storage 18Ah Battery Voltage with A/C Power: 27.28 w/o A/C Power 27.24 Date: 8/28/2020 FCPS: Manufacturer: Silent Knight Model# EVS-100 Panel/Breaker# Location:Admin.Nurse Office 18Ah 8/28/2020 Battery Voltage with A/C Power: 27.28 w/o A/C Power 27.26 Date: Owner/Rep: Phone#: Date: Inspector: Wyatt C. Phone#: 530 362 2609 Date: 11/1/24 Owners Rep Sign: Date:11/1/24 Inspector Sign: ALARM AND DETECTION REPORT Page 2 of 8 Property Site: Biggs Elementary School Operational #Tested This Equipment Total# Report Yes N/A Note# 4. Remote Annunciators 5. Zones 6. Manual Stations (Pull) 4 4 X Hardwire Addressable 7. Detectors Photoelectric 62 62 X Ionization Heats/Fixed or R of R 38 38 X Flame Duct(See#15) 8. Horn/Strobe Strobe Only Bell Speakers Horn 9. 10. Automatic Door Release 11. Water Flow switches Did W/F Ring Outside Bell? Did W/F Activate Alarm Panel? 12. Tamper Switches 13. PIV OS &Y 14. 15. Did test of Duct Detectors shut down air handling units? 16. Did the Monitoring Center(Fire Dept, Central Station, Lease Line) receive signal? 17. Is system reset for normal conditions? 18. Is system restored to operational service? 19. Have Proper Authorities (see#1)been notified system is back in service? List Proper Authorities: 20. Indicate %of equipment tested this report 25% 50% 75% VJI00% 21. Indicate %of equipment tested YTD 25% 50% 75% 100% Comments for any"no"answers or explanations (Note#): 11/1/24 Owners Rep Sign: Date: Inspector Sign: ALARM AND DETECTION REPORT Biggs Elementary School Page 3 of 8 Zone or DEVICE SLC DEVICE TYPE DEVICE LOCATION PASS FAIL NOTE# CHANNEL # HT Classroom 5 HVAC Closet X 97 M02 HT Classroom 8 X 97 M03 HT Classroom 9 X 97 M04 HT Classroom 10 X 97 M05 HT Classroom 8 X 97 M06 HT Classroom 7 X 97 M07 HT Classroom 6 X 97 M08 HT Classroom 14 X 97 M09 HT Classroom 15 X 97 M10 HT Classroom 13 X 97 M11 HT Classroom 16 X 97 M12 HT RM 13-16 Quad Lab/Office X 97 M13 HT RM 13-16 RR X 97 M14 HT Classroom 4 HVAC X 97 M20 HT Classroom 3 HVAC X 97 M21 HT Classroom 2 HVAC X 97 M22 HT Classroom 1 HVAC X 97 M23 HT Classroom 9 HVAC X 97 M24 HT Classroom 10 HVAC X 97 M25 HT RM 1 -4 Boys/Girls RR X 97 M26 HT Shed By RM 14 X 97 S23 HT D Bldg. RR Plumbing Chase X 97 S29 HT Classroom 17 X 01 M10 HT Classroom 18 X 01 M11 HT Classroom 19 X 01 M12 HT Classroom 20 X 01 M13 HT Classroom 21 X 01 M14 HT Classroom 22 X 01 M15 HT Classroom 24 X 01 M16 HT Classroom 23 X 01 M17 HT Classroom 25 X 01 M18 11/1/24 Owners Rep Sign: Date: Inspector Sign: ALARM AND DETECTION REPORT Biggs Elementary School Page 4 of 8 Zone or DEVICE SLC ZONE CHANNEL TYPE DEVICE LOCATION PASS FAIL NOTE# # HT Classroom 26 X 01 M19 HT Kitchen Water Heater Closet X 01 MO1 HT N. Kitchen Breezeway X 01 M02 HT Portable RR Attic X 01 M09 HT Kitchen Freezer Attic X 01 M20 HT Kitchen X 01 S05 HT Kitchen X 01 S06 PS By FACP X 97 MO1 PS MP NE. Exit X 01 M04 PS MP NW. Exit X 01 M07 PS MP S. Exit X 01 M08 BD MP N. X 01 S34 BD MP S. X 01 S35 KH Kitchen Ansul X 01 M03 11/1/24 Owners Rep Sign: Date: Inspector Sign: ALARM AND DETECTION REPORT Biggs Elementary School Page 5 of 8 Zone or DEVICE SLC DEVICE TYPE DEVICE LOCATION PASS FAIL NOTE# CHANNEL # PSD Portable Staff RR X 01 soil PSD Portable Girls RR X 01 S012 PSD Portable Boys RR X 01 S013 PSD Classroom 17 X 01 S014 PSD Classroom 18 X 01 S016 PSD Classroom 19 X 01 S018 PSD Classroom 20 X 01 S020 PSD Classroom 21 X 01 S022 PSD Classroom 22 X 01 S024 PSD Classroom 24 X 01 S026 PSD Classroom 23 X 01 S028 PSD Classroom 25 X 01 S030 PSD Classroom 26 X 01 S032 PSD MP Kitchen Food Storage X 01 S01 PSD Kitchen Food Storage X 01 SO2 PSD Kitchen RR X 01 SO4 PSD MP Peak X 01 S07 PSD MP Peak X 01 S10 PSD Above FACP Main Office X 97 soot PSD Admin Lobby X 97 S002 PSD Admin Nurses Office X 97 S003 PSD Admin Nurses Office RR X 97 S004 PSD Admin Principles Office X 97 S005 PSD Admin Teacher/Copier RM RR X 97 S006 PSD Admin Teacher/Copier RM RR X 97 S007 PSD Admin Boys RR X 97 S008 PSD Admin Girls RR X 97 S009 PSD Classroom 5 X 97 solo PSD Classroom 4 X 97 S012 PSD Classroom 3 X 97 S014 PSD Classroom 2 X 97 S016 11/1/24 Owners Rep Sign: Date: Inspector Sign: ALARM AND DETECTION REPORT Biggs Elementary School Page 6 of 8 Zone or DEVICE SLC DEVICE TYPE DEVICE LOCATION PASS FAIL NOTE# CHANNEL # PSD Classroom 1 X 97 S018 PSD Classroom 1 Work RM X 97 S020 PSD Classroom 1 RR Alcove X 97 S021 PSD Classroom 1 RR X 97 S022 PSD D Bldg. Office Elec. Closet X 97 S024 PSD D Bldg. Office X 97 S025 PSD D Bldg. Storage Closet X 97 S026 PSD D Bldg. Janitors Closet X 97 S027 PSD D Bldg. Girls RR X 97 S028 PSD D Bldg. Boys RR X 97 S030 PSD Classroom 8 X 97 S031 PSD Classroom 9 X 97 S033 PSD Classroom 10 X 97 S035 PSD Library RM 7 X 97 S037 PSD Library RM 7 X 97 S038 PSD Library RM 6 Conference X 97 S039 PSD Library RM 6 Conference X 97 S040 PSD Classroom 13-16 Janitor Closet X 97 S041 PSD Classroom 13-16 Staff RR X 97 S042 PSD Classroom 13-16 Quad Lab X 97 S043 PSD Classroom 13-16 Staff RR X 97 S044 PSD Classroom 13 X 97 S045 PSD Classroom 14 X 97 S048 PSD Classroom 13-16 Girls RR X 97 S049 PSD Classroom 13-16 Boys RR X 97 S050 PSD Classroom 15 X 97 S051 PSD Classroom 16 X 97 S054 PSD Classroom 13-16 Quad Lab X 97 S057 PSD Library 7 HVAC Closet X 97 S060 PSD Library 6 HVAC Closet X 97 S061 PSD F Bldg. Vestibule Staff RR X 97 S062 11/1/24 Owners Rep Sign: Date: Inspector Sign: ALARM AND DETECTION REPORT Biggs Elementary School Page 7 of 8 Zone or DEVICE SLC DEVICE TYPE DEVICE LOCATION PASS FAIL NOTE# CHANNEL # CO Classroom 5 X 97 S11 CO Classroom 4 X 97 S13 CO Classroom 3 X 97 S15 CO Classroom 2 X 97 S17 CO Classroom 1 X 97 S19 CO Classroom 8 X 97 S32 CO Classroom 9 X 97 S34 CO Classroom 10 X 97 S36 CO Classroom 13 X 97 S46 CO Classroom 14 X 97 S47 CO Classroom 14 X 97 S52 CO Classroom 16 X 97 S53 CO Classroom 13-16 Office X 97 S55 CO Classroom 13-16 Quad Lab X 97 S56 CO MP Peak X 01 S08 CO MP Peak X 01 S09 CO Classroom 17 X 01 S15 CO Classroom 18 X 01 S17 CO Classroom 19 X 01 S19 CO Classroom 20 X 01 S21 CO Classroom 21 X 01 S23 CO Classroom 22 X 01 S25 CO Classroom 24 X 01 S27 CO Classroom 23 X 01 S29 CO Classroom 25 X 01 S31 CO Classroom 26 X 01 S33 11/1/24 Owners Rep Sign: Date: Inspector Sign: ALARM AND DETECTION REPORT Biggs Elementary School Page 8 of 8 Zone or DEVICE sLC DEVICE CHANNEL # TYPE DEVICE LOCATION PASS FAIL NOTE# LEGEND PSD—Photoelectric Smoke Detector BD—Beam Detector H—Horn V—Visual ISD—Ionization Smoke Detector PS—Pull Station WPH—Weather Proof Horn TS—Tamper Switch PDD—Photo Duct Smoke Detector RR—Rate of Rise Heat Detector C—Chime WF—Water Flow Switch IDD—Ion Duct Smoke Detector HT—Fixed Temp Heat Detector CV—Chime Visual DH—Door Holder DHS—Door Holder&Smoke Detector FD—Flame Detector S—Speaker OSY—Outside Stem&Yoke Tamper Valve SSD—Signal Station Smoke Detector B—Bell AV—Audible Visual PIV—Post Indicator Valve Cur-Elevator Curtains FRD-Fire Rolldown Door SDC Smoke Detector&Door Holder Combo CO-Carbon Monoxide Detector - - - NOTE # COMMENT Discrepancies Found? I 1 Yes 1,1 No See Discrepancy Report? n Yes ✓ No 11/1/24 Owners Rep Sign: Date: Inspector Sign: