FAI23-0002 040-310-093 TRUROOTS LLC (317-C011)_ Fire Alarm Supplement-INITIATING DEVICES_ 6-27-2025 (Quarterly)
Fire Alarm Supplementary Form ��f, ,; Security Systems A VYANET OPERATING GROUP, INC.COMPANY Location Code: 045-317-0011 Contact: TRUROOTS LLC Company: Eagle Security Systems Contact Address: 29 SPEEDWAY AVE Address: 3268 Esplanade Ste A CHICO,CA 95928 Chico,CA 95973 Phone: 530 899 5000 Company Phone: 530-345-6395 Email: john.alston@truroots.com; Inspector: JOSE ANTONIO SANCHEZ LUNA MICHAEL.HIPP@TRUROOTS.COM NICET 1 165142,Expires:3/1/2027 Property Evaluated: TRUROOTS LLC(317-0011)(Business) Date of Work: 6/27/2025 29 SPEEDWAY AVE CHICO,CA 95928 Frequency: Quarterly Description: Fire Alarm Supplement(INITIATING DEVICES) Deficiency Summary There are no reported deficiencies for this submission General Comments There are no general comments for this submission Eagle Security Systems,3268 Esplanade Ste A,Chico,CA,95973 Phone:530-345-6395 Page 1 of 3 1�-'''' Eagle Security Systems ��� =� E AG L E 3268 Esplanade Ste A ;)(" Security Systems Chico,CA 95973 A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395 Fire Alarm Supplementary Form Account Information Facility Name: Property Type: Location Code: TRUROOTS LLC(317-0011) Business 045-317-0011 Service Address: 29 SPEEDWAY AVE,CHICO,CA,95928 Owner: Owner's Phone: TRUROOTS LLC 530-899-5000 Owner's Address: 29 SPEEDWAY AVE,CHICO,CA,95928 Legend PS-Pull Station SD-Smoke Detector DD-Duct Detector MM-Monitor Module(Ansul,temp,CO,etc) CM-Control Module I WF-Waterflow ITS-Tamper Switch I HD-Heat Detector I SC-Signal/Sounder Control Other I SPKR-Speakers I STROBE-Strobes I HORN-Horns/Horn-Strobes I BATT-Batteries T 1 Type Total Tested Not Passed Failed Total Tested Not Passed Failed Tested Tested HORN 1 0 1 0 0 PULL 2 0 2 0 0 SMOKE 14 10 14 10 10 I SUPERVISORY I 1 10 I 1 10 10 TS 17 10 17 to to IWF 15 10 15 to 10 Type Address Location Notes Frequency Last Tested Test Results Comments SMOKE 1 MAIN-UPSTAIRS OFFICE 4/4/2025 N/A SMOKE 1 MAIN UPSTAIRS 4/4/2025 N/A BREAKROOM SMOKE 2 MAIN-OFFICE 4/4/2025 N/A DOWNSTAIRS SMOKE 12 I MAIN-BREAKROOM 1 I 14/4/2025 I N/A PULL 3 MAIN-EAST WAREHOUSE 4/4/2025 N/A PULL 13 'MAIN-OFFICE 1 I 14/4/2025 I N/A MAIN-NORTH(4 WF 4 BAYS)WATERFLOW 4/4/2025 N/A (RISER 1) MAIN-NORTH MIDDLE(4 WF 5 BAYS)WATERFLOW 4/4/2025 N/A (RISER 2) ©2014 FormLink Systems,Inc., Fire Alarm Supplement v1.1 Page 2 of 3 01�����"'. Eagle Security Systems ��� :. EAGLE 3268 Esplanade Ste A -'' Security Systems Chico,CA 95973 A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395 i Type Address Locatio Notes Frequency Last Tested Test Results Comments MAIN-SOUTH MIDDLE(4 WF 6 BAYS)WATERFLOW 4/4/2025 N/A (RISER 3) TS 8 MAIN-NORTH(4 BAYS) 4/4/2025 N/A GATE VALVE TS 9 MAIN-NORTH MIDDLE(4 4/4/2025 N/A BAYS)GATE VALVE TS 10 MAIN-SOUTH MIDDLE(4 4/4/2025 N/A BAYS)GATE VALVE TS I 12 I MAIN-OS&Y(LEFT) I 4/4/2025 I N/A TS I 12 I MAIN-OS&Y(RIGHT) 14/4/2025 I N/A MAIN-FACU UPSTAIRS HORN 13 CLOSET/BREAKROOM- 4/4/2025 N/A SUPERVISORY MAIN-FACU UPSTAIRS SUPERVISO RI, 14 CLOSET/BREAKROOM- 4/4/2025 N/A BATTERIES MAIN-SOUTH END(5 WF 49 BAYS)WATER FLOW 4/4/2025 N/A (RISER 4) TS 50 MAIN-SOUTH END(5 4/4/2025 N/A BAYS)GATE VALVE WF 51 MAIN-MIDDLE WATERFLOW 4/4/2025 N/A TS 52 MAIN-MIDDLE RACK GATE VALVE 4/4/2025 N/A Comments Any deficiencies or other problems found with the devices must be explained using the comment specific for each device.Additional comments can be added here. Please see the summary section at the ton of the form for the comments. Inspector's Information Inspected By JOSE ANTONIO SANCHEZ LUNA I state that the information on this form is correct at the time and place of my inspection,and that all equipment tested at this time was left in operating condition upon completion of this inspection except as noted in the Comments. Signature of Inspector _J Date 6/27/2025 ©2014 FormLink Systems,Inc., Fire Alarm Supplement v1.1 Page 3 of 3