HomeMy WebLinkAboutFAI20-0005 009-162-014 CF FA HAZEL HOTEL_ Fire Alarm-SILENT KNIGHT 5820XL_ 3-3-2025 (Annual) Form for Inspection, Testing and Maintenance of 4;1' I ; Security Systems Fire Alarms and Signaling Systems A VYANET OPERATING GROUP, INC.COMPANY Location Code: 045-344-2122 Contact: TRISH STILWELL Company: Eagle Security Systems Contact Address: 880 HAZEL ST Address: 3268 Esplanade Ste A GRIDLEY,CA 95948 Chico,CA 95973 Phone: 530-846-7800 Company Phone: 530-345-6395 Email: HAZEL@CHIPHOUSING.ORG Inspector: JOSE ANTONIO SANCHEZ LUNA Property Evaluated: HAZEL HOTEL(Business) NICET 1 165142 880 HAZEL ST Date of Work: 3/3/2025 GRIDLEY,CA 95948 Frequency: Annual Description: Fire Alarm(SILENT KNIGHT 5820XL) Deficiency Summary Status:Open Severity:Non-Critical 6.2 Secondary Power Battery condition-Visual Inspection:No,Functional Test:No Out of date Status:Open Severity:Non-Critical 6.2 Secondary Power Load voltage-Visual Inspection:No,Functional Test:No Out of date Status:Open Severity:Non-Critical 6.2 Secondary Power Discharge test-Visual Inspection:No,Functional Test:No Out of date Status:Open Severity:Non-Critical 6.2 Secondary Power Charger test-Visual Inspection:No,Functional Test:No Out of date General Comments Batteries will need to be replaced due to being out of date Eagle Security Systems,3268 Esplanade Ste A,Chico,CA,95973 Phone:530-345-6395 Page 1 of 4 Eagle Security Systems 3268 Esplanade Ste A Security Systems Chico,CA 95973 A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395 Form for Inspection, Testing and Maintenance of Fire Alarms and Signaling Systems Separate forms are available for inspection,testing,and maintenance 4.System Information of the rest of the fire protection system of which the fire alarms and 4.1 Control Unit: signaling systems are a part.More frequent inspection,testing,and Manufacturer: Silent knight maintenance may be necessary depending on the conditions of the occupancy and the water supply. Model number: 5820x1 Notes: 4.2 Software and Firmware Revision number: 9.09 1. All questions are to be answered Yes,No,or Not Applicable.All 4.3 System Power: "No"answers are to be explained in the Comments for this form. 4.3.1 Primary(Main)Power: 2. Refer to NFPA-72 for specific inspection frequency requirements Nominal voltage: 120 for the different components. 1.Property Information Amps: 20 Owner: Location: Elevator Lobby TRISH STILWELL Overcurrent protection type: Breaker Owner's Phone Number: Amps: 20 530-846-7800 Disconnecting means location: #11 Owner's Address: 4.3.2 Secondary Power: 880 HAZEL ST,GRIDLEY,CA,95948 Type: Battery Property Being Evaluated: Location: Panel HAZEL HOTEL(Business) Battery type(if applicable): ❑Lead-acid❑Nickel- cadmiumPro e Address: Property ❑Primary(dry cell) 880 HAZEL ST,GRIDLEY,CA,95948 ❑✓Sealed lead-acid Assembly Description: Calculated capacity of batteries to drive the system: Fire Alarm(SILENT KNIGHT 5820XL) In standby mode(hours): 2.Owner's Section In alarm mode(minutes): A.Are the fire alarms and signaling systems ]Yes El No 5.Notifications Made Prior To Testing in service? B.Have fire alarms and signaling systems ❑✓Yes❑No Contact Time remained in service since the last inspection? C.Was the system(of which the fire alarm Monitoring Vyanet 9:15 and signaling systems are a part)free of organization: actuation of devices or alarms since the last ]Yes El No Building Staff 9:15 inspection? management: D.The required record documents are available and include the current revisions of Building occupants: Staff 9:15 all fire alarm software and the revisions of Yes❑No Authority Having software of any systems with which the fire Jurisdiction: N/a N/a alarm software interfaces? 3.Monitoring Information Other,if required: Monitoring organization: Vyanet Operating Group Address: 2700 Hegan Lane Suite 112 Chico CA,95926 Phone: 541-241-1800 Fax: Email: Account number: 344-2122 Phone line 1: Phone line 2: Means of transmission: CELL Entity to which alarms are retransmitted: Phone: NFPA 72 v1.1-2019 Page 2 of 4 1�D,,���"'. Eagle3268E Securityd Systems �� EA LE SteASecurity Systems Chico,splanaCA 95973e A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395 6.Testing Results 6.6 Supervising Station Monitoring 6.1 Control Unit and Related Equipment Description _ Yes/No Time(sec) Results I. Description Visual Functional Results Alarm signal ❑Yes❑No ❑Pass❑Fail A N/A Inspection Test Alarm ❑Pass❑Fail Control unit LdJ Yes A No ❑✓Yes❑No LJ Pass❑Fail restoration ❑Yes❑No J N/A N/A Lamps/LEDs/L LJ Pass❑Fail Trouble signal ❑Yes J No ❑Pass❑Fail CDsp ❑✓Yes J No ❑�Yes❑No ❑N/A NA N/A Trouble ❑Pass❑Fail Fuses ❑✓Yes❑No ❑�Yes III No LJ Pass❑Fail restoration Li Yes J No J N/A N/A Trouble signals LJ Pass Li Fail Supervisory _I Yes J No ❑Pass❑Fail LJ Yes J No LJ Yes Li No ❑N/A signal NA N/A Disconnect ❑Pass❑Fail Supervisory Li Yes J No ❑Pass❑Fail switches Li Yes J No Li Yes LJ No ]✓N/A restoration NA N/A 6.7 Public Emergency Alarm Reporting System Ground-fault ❑Pass❑Fail LiYes J No ❑Yes LJ No monitoring ❑]N/A Description Yes/No Time(seconds) Results 1 Supervision ❑Pass❑Fail Alarm signal ❑Pass❑Fail LJ Yes J No LJ Yes Li No J N/A ❑Yes J No _✓I N/A Local ❑Pass❑Fail Alarm ❑Pass❑Fail annunciator LJ Yes J No LJ Yes❑No J N/A ❑Yes J No restoration _✓I N/A Remote ❑Pass❑Fail Trouble signal ❑Pass❑Fail annunciators III Yes❑✓No ❑Yes 0 No J N/A ❑Yes J No ❑✓N/A Remote power ❑Pass❑Fail Trouble ❑Pass❑Fail ❑Yes�✓No ❑Yes❑�/No ❑Yes 11No panels _✓I N/A restoration J N/A ❑Pass❑Fail Supervisory ❑Pass❑Fail Other: ❑Yes No ❑Yes❑No ❑N/A signal ry ❑Yes J No NA N/A g 6.2 Secondary Power Supervisory ❑Yes J No LI Pass❑Fail Description Visual Functional Results restoration NA N/A Inspection Test ‘ 7.Notifications That Testing Is Complete Battery ❑Yes�✓No ❑Yes❑O No ❑Pass❑✓Fail Contact A Time condition J N/A Monitoring Vyanet 11:45 Load voltage ❑Yes NA No ❑Yes❑�/No ❑Pass❑d Fail organization: y J N/A Building Staff 11:45 Discharge test ❑Pass❑✓Fail management:❑Yes NA No ❑Yes❑I/No J N/A g Charger test ❑Pass❑✓Fail Building occupants: Staff 11:45 ❑Yes NA No ❑Yes❑�/No ❑N/A Authority Having Jurisdiction: N/a N/a Remote panel ❑ ❑Pass❑Fail batteries YesNANo ❑Yes❑�No J N/A Other,if required: 6.3 Alarm and Supervisory Alarm Initiating Device 8.System Restored To Normal Operation Complete supplementary device test form for all initiating devices. Date: 3/3/2025 6.4 Notification Appliances Time: 11:45 Complete supplementary appliance test form for all notification 9.Comments appliances. Any "No"answers, test failures or other problems found with the fire 6.5 Interface Equipment alarm system must be explained using the comment specific for each Complete supplementary interface component test form for all question.Additional comments can be added here. interface components. Please see the summary section at the top of the form for the Circuit Interface/Signaling Line Circuit Interface/Fire Alarm comments. Control Interface 10.Inspector's Information Inspected By JOSE ANTONIO SANCHEZ LUNA Inspector License: NICET 1 165142 I state that the information on this form is correct at the time and place of my inspection,and that all equipment tested at this time was left in operating condition upon completion of this inspection except as noted in the Comments.This system as specified herein has been inspected and tested according to NFPA 72,2016 edition,Chapter 14. NFPA 72 v1.1-2019 Page 3 of 4 Eagle Security Systems EAGLE 3268 Esplanade Ste A Security Systems Chico,CA 95973 A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395 Signature of Inspector Date 3/3/2025 11.Owner or Owner's Representative Owner or Owner's Representative Name Owner or Owner's Representative Signature No Signature Available Date 3/3/2025 NFPA 72 v1.1-2019 Page 4 of 4