HomeMy WebLinkAboutFAI20-0026 010-180-035 CF FA 2024 Wilson Elementary Fire Alarm and Life Safety System Inspection Certificate For Wilson Elementary School 429 Magnolia Street Gridley, CA 95948 Tested to NFPA 72 Standards This Inspection was performed in accordance with applicable NFPA Standards. The subsequent pages of this report provide performance measurements, listed ranges of acceptable results, and complete documentation of the inspection. Whenever discrepancies exist between acceptable performance standards and actual test results, notes and/or recommended solutions have been proposed or provided for immediate review and approval. Annual Inspection Inspection Date Aug 15, 2024 Building:Wilson Elementary School Company: Hue&Cry,Inc. Contact:Jordan Reeves Contact:Nick Kuykendall Title: Superintendent Title: INSPECTOR/TECHNICIAN Fire Alarm Testing Report Executive Summary Generated by:BuildingReports.com Building Information Building: Wilson Elementary School Contact: Jordan Reeves Address: 429 Magnolia Street Phone: 1-530-846-4721 Address: Fax: City/State/ZIP Code: Gridley, CA 95948 Mobile: Country: United States of America Email:jreeves@gusd.org Inspection Performed By Company: Hue&Cry, Inc. Inspector: Nick Kuykendall Address: 1751 Bruce Drive Phone: 800-800-alarm Address: Fax: City/State/ZIP Code:Anderson, California 96007 Mobile: Country: United States of America Email: n.kuykendall@hueandcry.com System Control Unit Manufacturer: Honeywell Inspection Date: 08/15/2024 IDC Style: Model Number: 6820 EVS Install Date: 01/30/2005 SLC Style: Software Version: Version Date: 11/20/2018 NAC Style: Location: Custodian Room Current Protection: Breaker Disconnect Location: Custodian Room Type: Breaker Hue&Cry,Inc. Page 2 of 16 Download Date:08/16/2024 Executive Summary Inspection Summary Total Items Serviced Passed Failed/Other Category: Qty % Qty % Qty % Qty % Control 15 14.85% 15 100.00% 14 93.33% 1 6.67% Indicating 41 40.59% 41 100.00% 40 97.56% 1 2.44% Initiating 45 44.55% 45 100.00% 45 100.00% 0 0.00% Totals 101 100% 101 100.00% 99 98.02% 2 1.98% Certification Company: Hue&Cry, Inc. Building:Wilson Elementary School Inspector: Nick Kuykendall Contact: Jordan Reeves Signed: Aug 15, 2024 Signed: Nick Kuykendall Certifications Certification Type Number C-10 Electrical Licensed Contractor 620587 Hue&Cry,Inc. Page 3 of 16 Download Date:08/16/2024 Executive Summary Discrepancy Report Generated by:BuildingReports.com Building: Wilson Elementary School ontro1 Panel: 1 The Discrepancy Report consolidates each discrepancy listed within the various Testing sections of your Inspection. Discrepancies are listed by Category, and grouped by device type. The description of the problem is provided and where appropriate, code references are listed for your convenience.Any item that was inspected that is subject to a recall or part of a manufacturer's replacement/upgrade program is included. evice Type Manufacture ModelNumbe' Date Qty Items listed for Recall or Replacement/Upgrade No items found during this inspection. ScaniD Location Problem Address Reference Control Battery 1 44834484 FACP (L) Failed Test 1 NFPA72 Table 14.4.3.2 (9)c(1) Indicating Horn/Strobe 1 11531289 Cafe North EOL 3.9k 27v Damaged/Worn 1 NFPA72 14.2.2.2.2 Code References NFPA72 Table 14.4.3.2(9)cBatteries shall be replaced in accordance with the recommendations of the alarm equipment (1) manufacturer or when the recharged battery voltage or current falls below the manufacturer's recommendations NFPA72 14.2.2.2.2 System deficiencies shall be corrected. Hue&Cry,Inc. Page 4 of 16 Download Date:08/16/2024 Discrepancy Report Proposed Solutions Report Generated by:BuildingReports.com Building: Wilson Elementary School Control Panel: 1 The Proposed Solution Report provides a solution for each discrepancy listed on the Discrepancy Report.Provide a check mark where indicated to approve repairs listed within the report.Items listed as T/M are available for repair on a Time and Materials basis. ScaniD Locati ix Control Battery 44834484 FACP(L) Replace Battery DURA12-8F2 T/M ❑ Indicating Horn/Strobe 11531289 Cafe North EOL 3.9k 27v Replace GX90s-4-15 T/M ❑ /75WR PO#: (none) T/M Hue&Cry,Inc. Page 5 of 16 Download Date:08/16/2024 Proposed Solutions Report Notes & Recommendations Generated by:BuildingReports.com Building: Wilson Elementary School The Notes&Recommendations Report details additional inspection notes made by the Inspectors during the course of the building inspection.Notes are grouped by Category. General Note Horn/strobe in cafeteria damaged and needs to be replaced Batteries in FACP need to be replaced (only one battery passed/recommend replacing both) 12v7ah x2 Ed White(contact for service): Personal 530-403-7841 /Work 530-470-3118 Hue&Cry,Inc. Page 6 of 16 Download Date:08/16/2024 Notes&Recommendations Inspection & Testing Generated by:BuildingReports.com Building: Wilson Elementary School Control Panel: 1 The Inspection& Testing section lists all of the items inspected in your building.Items are grouped by Passed or Failed/Other.Items are listed by Category. Each item includes the services performed, and the time&date at which testing occurred. Device Type Location Service Time Date Passed Control Annunciator Office Annual 8:10:58 AM 08/15/2024 Battery Power Supply Kitchen Annual 10:14:45 AM 08/15/2024 Battery EVS Amplifier(L) Annual 8:47:10 AM 08/15/2024 Battery EVS Amplifier(R) Annual 8:49:51 AM 08/15/2024 Battery FACP(R) Annual 8:01:52 AM 08/15/2024 Battery Room 22 Power Supply(L) Annual 8:52:34 AM 08/15/2024 Battery Room 22 Power Supply(R) Annual 8:54:04 AM 08/15/2024 Disconnect Janitors Room Main Hall Annual 10:34:14 AM 08/15/2024 Disconnect Kitchen Circuit Panel B#12 Annual 10:15:53 AM 08/15/2024 Disconnect Room 22 Annual 10:15:59 AM 08/15/2024 Power Supply Kitchen Annual 10:14:32 AM 08/15/2024 Power Supply Room 22 Annual 8:51:51 AM 08/15/2024 Power Supply Room 22 EVS Amplifier Annual 8:46:59 AM 08/15/2024 Indicating Horn Library Outside Annual 10:53:14 AM 08/15/2024 Horn Main Hall Room 16 Annual 10:53:10 AM 08/15/2024 Horn Main Hall Rooms 11-12 Annual 10:53:03 AM 08/15/2024 Horn Main Hall at Janitors Room Annual 10:53:06 AM 08/15/2024 Horn Outside Room 21 Annual 10:53:22 AM 08/15/2024 Horn Outside Room 26 Annual 10:54:58 AM 08/15/2024 Horn Outside Room 32 Annual 10:55:01 AM 08/15/2024 Horn Outside Room 35 Annual 10:55:04 AM 08/15/2024 Horn Outside Rooms 19-20 Annual 10:53:17 AM 08/15/2024 Horn Room 36. EOL 3.9k 27v Annual 10:55:38 AM 08/15/2024 Horn Room 25 Annual 10:54:51 AM 08/15/2024 Horn Room 26 Annual 10:54:55 AM 08/15/2024 Horn Room 30 Annual 10:55:51 AM 08/15/2024 Horn Room 31 Annual 10:55:48 AM 08/15/2024 Horn Room 32 Annual 10:55:45 AM 08/15/2024 Hue&Cry,Inc. Page 7 of 16 Download Date:08/16/2024 Inspection&Testing Device Type Location Service Time Date Passed Horn Room 33 Annual 10:55:42 AM 08/15/2024 Horn Room 34 Annual 10:55:07 AM 08/15/2024 Horn Room 35 Annual 10:55:35 AM 08/15/2024 Horn/Strobe Cafe South Annual 10:55:54 AM 08/15/2024 Speaker Outside Room 17 Annual 10:52:57 AM 08/15/2024 Speaker Outside Room 19 Annual 10:52:53 AM 08/15/2024 Speaker/Strobe Boys Restroom Annual 10:51:54 AM 08/15/2024 Speaker/Strobe Girls Restroom Annual 10:51:57 AM 08/15/2024 Speaker/Strobe Room 17 Annual 10:52:28 AM 08/15/2024 Speaker/Strobe Room 17 Annual 10:52:32 AM 08/15/2024 Speaker/Strobe Room 18 Annual 10:52:21 AM 08/15/2024 Speaker/Strobe Room 19 Annual 10:52:07 AM 08/15/2024 Speaker/Strobe Room 20 Annual 10:52:04 AM 08/15/2024 Speaker/Strobe Room 21 Annual 10:52:00 AM 08/15/2024 Speaker/Strobe Room 22 Annual 10:51:50 AM 08/15/2024 Speaker/Strobe Staff Restroom Annual 10:52:46 AM 08/15/2024 Speaker/Strobe Staff Restroom Annual 10:52:49 AM 08/15/2024 Speaker/Strobe Storage Annual 10:52:43 AM 08/15/2024 Speaker/Strobe Office Room 17 Annual 10:52:36 AM 08/15/2024 Speaker/Strobe Restroom Room 17 Annual 10:52:39 AM 08/15/2024 Strobe Boys R/R by Room 33 Annual 10:51:38 AM 08/15/2024 Strobe Girls R/R by Room 33 Annual 10:51:32 AM 08/15/2024 Strobe Girls R/R by Room 33 Annual 10:51:41 AM 08/15/2024 Strobe Handicap R/R by Room 33 Annual 10:51:35 AM 08/15/2024 Strobe Kitchen Annual 10:51:44 AM 08/15/2024 Initiating Heat Detector Room 17 Annual 10:33:18 AM 08/15/2024 Heat Detector Room 18 Annual 9:48:35 AM 08/15/2024 Heat Detector Room 18 Annual 9:48:45 AM 08/15/2024 Heat Detector Room 19 Annual 9:48:32 AM 08/15/2024 Heat Detector Room 20 Annual 9:48:29 AM 08/15/2024 Heat Detector Room 21 Annual 9:48:26 AM 08/15/2024 Heat Detector Room 22 Annual 9:48:20 AM 08/15/2024 Heat Detector Restroom Room 17 Annual 10:33:22 AM 08/15/2024 Pull Station Cafe North Annual 10:09:42 AM 08/15/2024 Pull Station Cafe South Annual 10:13:08 AM 08/15/2024 Pull Station Main Hall North Doors Annual 8:16:18 AM 08/15/2024 Hue&Cry,Inc. Page 8 of 16 Download Date:08/16/2024 Inspection&Testing Device Type Location Service Time Date Passed Pull Station Main Hall Office Annual 8:18:46 AM 08/15/2024 Pull Station Main Hall Room 14B Annual 8:32:02 AM 08/15/2024 Pull Station Main Hall South End Annual 8:34:00 AM 08/15/2024 Pull Station Office Annual 8:14:00 AM 08/15/2024 Pull Station Room 24 Annual 8:42:27 AM 08/15/2024 Pull Station Room 25 Annual 8:39:50 AM 08/15/2024 Pull Station Room 26 Annual 8:38:23 AM 08/15/2024 Pull Station Room 30 Annual 9:47:58 AM 08/15/2024 Pull Station Room 31 Annual 9:50:05 AM 08/15/2024 Pull Station Room 32 Annual 9:51:42 AM 08/15/2024 Pull Station Room 33 Annual 9:52:50 AM 08/15/2024 Pull Station Room 34 Annual 9:55:35 AM 08/15/2024 Pull Station Room 35 Annual 9:56:41 AM 08/15/2024 Pull Station Room 36 Annual 9:57:46 AM 08/15/2024 Smoke Detector All-Gender Restroom Annual 9:06:15 AM 08/15/2024 Smoke Detector Boys Restroom Annual 9:07:42 AM 08/15/2024 Smoke Detector Girls Restroom Annual 9:07:44 AM 08/15/2024 Smoke Detector Room 17 Annual 10:21:25 AM 08/15/2024 Smoke Detector Room 17 Annual 10:21:28 AM 08/15/2024 Smoke Detector Room 18 Annual 9:00:05 AM 08/15/2024 Smoke Detector Room 18 Annual 9:01:40 AM 08/15/2024 Smoke Detector Room 19 Annual 9:00:02 AM 08/15/2024 Smoke Detector Room 19 Annual 9:01:50 AM 08/15/2024 Smoke Detector Room 20 Annual 8:58:01 AM 08/15/2024 Smoke Detector Room 20 Annual 8:58:04 AM 08/15/2024 Smoke Detector Room 21 Annual 8:55:58 AM 08/15/2024 Smoke Detector Room 21 Annual 8:57:54 AM 08/15/2024 Smoke Detector Room 22 Annual 8:45:48 AM 08/15/2024 Smoke Detector Room22 Annual 8:45:56 AM 08/15/2024 Smoke Detector Staff Restroom Annual 9:05:13 AM 08/15/2024 Smoke Detector Storage Annual 10:21:31 AM 08/15/2024 Smoke Detector Work room Annual 10:21:36 AM 08/15/2024 Smoke Detector Custodian Room Annual 8:45:36 AM 08/15/2024 Smoke Detector Office Room 17 Annual 10:21:22 AM 08/15/2024 Device Type Location Service Time Date Failed/Other Control Hue&Cry,Inc. Page 9 of 16 Download Date:08/16/2024 Inspection&Testing Device Type Location Service Time Date Failed/Other 1 Battery FACP(L) Annual 8:01:49 AM 08/15/2024 Indicating 1 Horn/Strobe Cafe North EOL 3.9k 27v Annual 10:12:07 AM 08/15/2024 Hue&Cry,Inc. Page 10 of 16 Download Date:08/16/2024 Inspection&Testing Building: Wilson Elementary School Control Panel: 2 - Honeywell 6820 EVS The Inspection& Testing section lists all of the items inspected in your building.Items are grouped by Passed or Failed/Other.Items are listed by Category.Each item includes the services performed, and the time&date at which testing occurred. Device Type ocation ervice to Passed Control Control Panel Custodian Room Annual 7:51:03 AM 08/15/2024 Hue&Cry,Inc. Page 11 of 16 Download Date:08/16/2024 Inspection&Testing Service Summary Generated by:BuildingReports.com Building: Wilson Elementary School The Service Summary section provides an overview of the services performed in this report. Device Type Service Quantity Failed/Other Battery Annual 1 Horn/Strobe Annual 1 Total 2 Passed Annunciator Annual 1 Battery Annual 6 Control Panel Annual 1 Disconnect Annual 3 Heat Detector Annual 8 Horn/Strobe Annual 1 Horn Annual 18 Power Supply Annual 3 Pull Station Annual 17 Smoke Detector Annual 20 Speaker/Strobe Annual 14 Speaker Annual 2 Strobe Annual 5 Total 99 Grand Total 101 Hue&Cry,Inc. Page 12 of 16 Download Date:08/16/2024 Service Summary Auxiliary Functions Testing Generated by:BuildingReports.com Building: Wilson Elementary School Control Panel: 1 The Auxiliary Functions Testing section lists each of the ancillary items, systems, and emergency equipment that are controlled by the system control unit.Items are grouped by Passed or Failed/Other. The items are listed by device type, and a check box is provided to indicate if the test conducted was simulated. Type Location Comment ScaniD Simulated Passed Smoke Detector Smoke Compartment All-Gender Restroom Passed 44834486 Smoke Compartment Boys Restroom Passed 44834527 Smoke Compartment Girls Restroom Passed 44834526 Smoke Compartment Room 17 Passed 44834501 Smoke Compartment Room 17 Passed 44834500 Smoke Compartment Room 18 Passed 44834510 Smoke Compartment Room 18 Passed 44834499 Smoke Compartment Room 19 Passed 44834515 Smoke Compartment Room 19 Passed 448314 Smoke Compartment Room 20 Passed 44834520 Smoke Compartment Room 20 Passed 44834518 Smoke Compartment Room 21 Passed 44834521 Smoke Compartment Room 21 Passed 4623 Smoke Compartment Room 22 Passed 44834539 Smoke Compartment Room22 Passed 44834538 Smoke Compartment Staff Restroom Passed 44834488 Smoke Compartment Storage Passed 44834491 Smoke Compartment Work room Passed 44834481 Smoke Compartment Custodian Room Passed 60675142 Smoke Compartment Office Room 17 Passed 44834506 Hue&Cry,Inc. Page 13 of 16 Download Date:08/16/2024 Auxiliary Functions Testing Battery & Power Supply Testing Generated by:BuildingReports.com Building: Wilson Elementary School Control Panel: 1 The Battery&Power Supply Testing section details the readings and measurements of batteries and power supplies used to provide power to the fire alarm and life safety systems.Items are grouped by Passed or Failed/Other. Rated Rated Post Type Location Ah Volts Pre Test Test Min Ah Tested Ah Battery Passed Sealed Lead Acid Power Supply Kitchen 7 12 Sealed Lead Acid EVS Amplifier(L) 7 12 Sealed Lead Acid EVS Amplifier(R) 7 12 Sealed Lead Acid FACP(R) 8 12 12.87 4.55 4.8 Sealed Lead Acid Room 22 Power Supply(L) 8 12 Sealed Lead Acid Room 22 Power Supply(R) 8 12 Failed/Other Sealed Lead Acid FACP(L) 8 12 12.93 4.55 4.4 Hue&Cry,Inc. Page 14 of 16 Download Date:08/16/2024 Battery&Power Supply Testing Inventory & Warranty Report Generated by:BuildingReports.com Building: Wilson Elementary School Control Panel: 1 The Inventory& Warranty Report lists each of the devices and items that are included in your Inspection Report.A complete inventory count by device type and category is provided.Items installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together.for easy reference. Device or Type Catego %of Inventory Quantity Annunciator Control 0.99% 1 Battery Control 6.93% 7 Control Panel Control 0.99% 1 Disconnect Control 2.97% 3 Heat Detector Initiating 7.92% 8 Horn Indicating 17.82% 18 Horn/Strobe Indicating 1.98% 2 Power Supply Control 2.97% 3 Pull Station Initiating 16.83% 17 Smoke Detector Initiating 19.80% 20 Speaker Indicating 1.98% 2 Speaker/Strobe Indicating 13.86% 14 Strobe Indicating 4.95% 5 Type Qty Model# Description Install Date In Service - 90 Days - 1 Year Power Sonic Battery 2 PS-1270 F1 Sealed Lead Acid 08/18/2023 In Service - 1 Year to 2 Years Precision Consumer P Battery 2 B LA12V 7.0A Sealed Lead Acid 05/10/2023 In Service- 3 Years to 5 Years Power-Sonic Battery 1 PS-1270 F1 Sealed Lead Acid 11/24/2020 Duracell Battery 2 DURA12-8F2 Sealed Lead Acid 04/30/2020 In Service- 15 Years to 25 Years GE Disconnect 1 20amp Breaker 01/31/2005 Disconnect 1 Breaker 01/30/2005 FCI Horn 9 130-3117c 01/30/2005 Pull Station 9 MS-2 Dual Action 01/30/2005 FIRE•LITE Alarms, In Hue&Cry,Inc. Page 15 of 16 Download Date:08/16/2024 Inventory&Warranty Report Pull Station 1 BG-8 Dual Action 01/30/2005 Faraday Horn 1 01/30/2005 Fire-Lite Pull Station 2 BG10 Dual Action 01/30/2005 Gentex Horn/Strobe 2 GX90s-4-15/75WR 01/30/2005 Strobe 1 GXS-4-15/75WR 01/30/2005 Honeywell Power Supply 1 EVS-50W 01/30/2005 Smoke Detector 1 SK-Fire-Co Combination 01/30/2005 Smoke Detector 19 SK- Photo Photoelectric 01/30/2005 Silent Knight Annunciator 1 RA-1000R LCD Display 01/30/2005 Heat Detector 8 SK-HEAT-HT Fixed Temperature 01/30/2005 Power Supply 1 5496 01/30/2005 Standard Horn 5 14 01/30/2005 Power Supply 1 Fire Lite Box Only 01/30/2005 Pull Station 5 750 Single Action 01/30/2005 System Sensor Speaker 2 SPWK 01/30/2005 Speaker/Strobe 2 SPSCRL 01/30/2005 Speaker/Strobe 12 SPSRL 01/30/2005 Wheelock Horn 3 MT 12/24 01/30/2005 Strobe 4 RS-241575 01/30/2005 Zinsco Disconnect 1 20amp Breaker 01/30/2005 Building: Wilson Elementary School Control Panel: 2 - Honeywell 6820 EVS The Inventory& Warranty Report lists each of the devices and items that are included in your Inspection Report.A complete inventory count by device type and category is provided.Items installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together for easy reference. Type Qty Model# Description Install Date In Service- 15 Years to 25 Years Honeywell Control Panel 1 6820 EVS Conventional 01/30/2005 Hue&Cry,Inc. Page 16 of 16 Download Date:08/16/2024 Inventory&Warranty Report