Loading...
HomeMy WebLinkAboutFAI23-0002 040-310-093 CF FA TRUROOTS LLC (317-C011)_ Fire Alarm-BOSCH D9412GV2_ 4-4-2025 (Annual) Form for Inspection, Testing and Maintenance of �1, * Security Systems Fire Alarms and Signaling Systems A VYANET OPERATING GROUP, INC.COMPANY Location Code: 045-317-0011 Contact: TRUROOTS LLC Company: Eagle Security Systems Contact Address: 29 SPEEDWAY AVE Address: 3268 Esplanade Ste A CHICO,CA 95928 Chico,CA 95973 Phone: 530-899-5000 Company Phone: 530-345-6395 Email: john.alston@truroots.com; Inspector: JOSE ANTONIO SANCHEZ LUNA MICHAEL.HIPP@TRUROOTS.COM NICET 1 165142 Property Evaluated: TRUROOTS LLC(317-CO11)(Business) Date of Work: 4/4/2025 29 SPEEDWAY AVE CHICO,CA 95928 Frequency: Annual Description: Fire Alarm(BOSCH D9412GV2) Deficiency Summary Please refer to the Deficiency Summary located on applicable Fire Alarm Supplementary Forms for additional deficiency details. General Comments There are no general comments for this submission Eagle Security Systems,3268 Esplanade Ste A,Chico,CA,95973 Phone:530-345-6395 Page 1 of 4 Eagle Security Systems S AG L E 3268 Esplanade Ste A Security Systems Chico,CA 95973 A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395 Form for Inspection, Testing and Maintenance of Fire Alarms and Signaling Systems Separate forms are available for inspection,testing,and maintenance 4.System Information of the rest of the fire protection system of which the fire alarms and 4.1 Control Unit: signaling systems are a part.More frequent inspection,testing,and Manufacturer: BOSCH maintenance may be necessary depending on the conditions of the occupancy and the water supply. Model number: D9412GV2 Notes: 4.2 Software and Firmware Revision number: 7.08 1. All questions are to be answered Yes,No,or Not Applicable.All 4.3 System Power: "No"answers are to be explained in the Comments for this form. 4.3.1 Primary(Main)Power: 2. Refer to NFPA-72 for specific inspection frequency requirements Nominal voltage: 120 for the different components. 1.Property Information Amps: 20 Owner: Location: WEST WALL/ TRUROOTS LLC UPSTAIRS BREAKROOM Owner's Phone Number: Overcurrent protection type: THERMAL 530-899-5000 Amps: 20 Owner's Address: Disconnecting means location: PANEL L/BREAKER 29 SPEEDWAY AVE.CHICO.CA.95928 #7 Property Being Evaluated: 4.3.2 Secondary Power: TRUROOTS LLC(317-CO111(Business) Type: BATTERY Property Address: Location: @FACU 29 SPEEDWAY AVE.CHICO.CA.95928 Battery type(if applicable): ❑Lead-acid❑Nickel- Assembly Description: cadmium Fire Alarm(BOSCH D9412GV21 ❑Primary(dry cell) 2.Owner's Section L✓J Sealed lead-acid A.Are the fire alarms and signaling systems Calculated capacity of batteries to drive the system: in service? ✓Yes❑No In standby mode(hours): B.Have fire alarms and signaling systems In alarm mode(minutes): remained in service since the last inspection? Yes❑No 5.Notifications Made Prior To Testing C.Was the system(of which the fire alarm and signaling systems are a part)free of ❑✓yes❑No Contact Time actuation of devices or alarms since the last Monitoring Vyanet 9:31 organization: D.The required record documents are available and include the current revisions of Building Staff 9:31 all fire alarm software and the revisions of Yes❑No management: software of any systems with which the fire alarm software interfaces? Building occupants: Staff 9:31 3.Monitoring Information Authority Having N/a N/a Monitoring organization: VYANET Jurisdiction: OPERATING GROUP Address: 410 SW COLUMBIA Other,if required: STREET;SUITE#120 BEND.OR 97702 Phone: 541-241-1800 Fax: Email: Account number: 317/318-CO11 Phone line 1: Phone line 2: Means of transmission: Radio Entity to which alarms are retransmitted: Phone: NFPA 72 v1.1-2019 Page 2 of 4 01' 1� ���"'� Eagle3268ElSecuritydSystems EA LE SteASecurity Systems Chico,CA 95973 A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395 6.Testing Results 6.6 Supervising Station Monitoring 6.1 Control Unit and Related Equipment lscriptio Yes/No I i 7 Alarm signal ❑Pass❑Fail escription Visual Functional Results ❑Yes J No ❑✓N/A Inspection Test Alarm ❑Pass❑Fail Control unit ❑d yes❑No ❑d Yes❑No 0 Pass❑Fail restoration ❑Yes 0 No ❑✓N/A N/A Lamps/LEDs/L IA Pass❑Fail Trouble signal ❑Yes 0 No ❑Pass❑Fail CDsp 0 Yes 0 No 0Yes❑No ]N/A 0 N/A Trouble ❑Pass❑Fail Fuses 0 Yes 0 No 0 Yes III No L✓J Pass❑Fail restoration ❑Yes J No 0 N/A N/A Trouble signals L✓Jas❑PsFail Supervisory ❑Yes J No ❑Pass❑Fail L✓J Yes J No L_l Yes❑No a Li signal 0 N/A Disconnect L✓J Pass❑Fail/A Supervisory ❑Yes J No ❑Pass CI Fail switches L✓J Yes J No L_l Yes❑No ]N/A restoration 0 N/A 6.7 Public Emergency Alarm Reporting System Ground-fault CIPass CIFail ❑Yes 0 No ❑Yes LJ No monitoring ]]N/A Description [ Yes/No I I Time(seconds) Results Supervision 0 Pass❑Fail Alarm signal ❑Pass❑Fail L✓J Yes J No L�Yes❑No J N/A ❑Yes❑No _✓1 N/A Local ❑Pass❑Fail Alarm CI Pass CI Fail annunciator ❑Yes�I No ❑Yes LJ No 0 N/A ❑Yes❑No restoration _✓I N/A Remote ❑✓Pass❑Fail Trouble signal CI Pass CI Fail annunciators ❑✓Yes J No 0 Yes III No J N/A ❑Yes❑No ❑✓N/A Remote power ❑Pass❑Fail Trouble ❑Pass❑Fail ❑Yes❑✓No ❑Yes❑�/No ❑Yes❑No panels _✓I N/A restoration 0 N/A ❑Pass❑Fail Supervisory ❑Pass❑Fail Other: ❑Yes❑No Cl Yes❑No J N/A signal ry ❑Yes J No NAN/A g 6.2 Secondary Power Supervisory ❑Yes J No ❑Pass❑Fail Description Visual Functional Results restoration ❑✓N/A Inspection Test 1 7.Notifications That Testing Is Complete Batte 0 Pass❑Fail condi on ❑✓Yes J No ❑O Yes❑No J N/A Contact Monitoring Load voltage ❑✓Yes❑No ❑/Yes❑No ❑✓Pass❑Fail organization: Vyanet 10:33 J N/A Building Staff 10:33 Discharge test ❑✓Yes❑No ❑/Yes❑No ❑✓Pass❑Fail management: J N/A Charger test ❑✓Pass CI Fail Building occupants: Staff 10:33 ❑✓Yes❑No ❑/Yes❑No 0 N/A Authority Having Jurisdiction: N/a N/a Remote panel ❑Pass❑Fail batteries CI Yes NA No CI Yes❑�No 0 N/A Other,if required: 6.3 Alarm and Supervisory Alarm Initiating Device 8.System Restored To Normal Operation Complete supplementary device test form for all initiating devices. Date: 4/4/2025 6.4 Notification Appliances Time: 10:33 Complete supplementary appliance test form for all notification 9.Comments appliances. Any "No"answers, test failures or other problems found with the fire 6.5 Interface Equipment alarm system must be explained using the comment specific for each Complete supplementary interface component test form for all question.Additional comments can be added here. interface components. Please see the summary section at the top of the form for the Circuit Interface/Signaling Line Circuit Interface/Fire Alarm comments. Control Interface 10.Inspector's Information Inspected By JOSE ANTONIO SANCHEZ LUNA Inspector License: NICET 1 165142 I state that the information on this form is correct at the time and place of my inspection,and that all equipment tested at this time was left in operating condition upon completion of this inspection except as noted in the Comments.This system as specified herein has been inspected and tested according to NFPA 72,2019 edition,Chapter 14. NFPA 72 v1.1-2019 Page 3 of 4 1�����"'� Eagle3268Esplana Securitdy Systems ��� =� EAGLE e SteA ' 0Security Systems Chico,CA 95973 A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395 Signature of Inspector Date 4/4/2025 11.Owner or Owner's Representative Owner or Owner's Representative Name Owner or Owner's Representative Signature No Signature Available Date 4/4/2025 NFPA 72 v1.1-2019 Page 4 of 4