HomeMy WebLinkAboutFAI25-0007 039-060-088 CF FA FWHA- PATRICK RANCH GLENWOOD (MANSION _ VC)_ Fire Alarm-RADIONICS 7412_ 2-28-2025 (Annual) Form for Inspection, Testing and Maintenance of �11, 4*
Security Systems
Fire Alarms and Signaling Systems A VYANET OPERATING GROUP, INC.COMPANY
Location Code: 045-301-2832
Contact: YVETTE ZUNIGA Company: Eagle Security Systems
Contact Address: 10381 MIDWAY,MANSION VC Address: 3268 Esplanade Ste A
CHICO,CA 95928-9599
Chico,CA 95973
Phone: 530-519-1460 Company Phone: 530-345-6395
Email: YVETTE@PATRICKRANCHMUSEUM. Inspector: JOSE ANTONIO SANCHEZ LUNA
ORG; NICET 1 165142
ADMIN@FARWESTHERITAGE.ORG
Date of Work: 2/28/2025
Property Evaluated: FWHA-PATRICK RANCH
GLENWOOD(MANSION&VC) Frequency: Annual
(Business)
10381 MIDWAY,MANSION VC
CHICO,CA 95928-9599
Description: Fire Alarm(RADIONICS 7412)
Deficiency Summary
Please refer to the Deficiency Summary located on applicable Fire Alarm Supplementary Forms for additional deficiency details.
General Comments
There are no general comments for this submission
Eagle Security Systems,3268 Esplanade Ste A,Chico,CA,95973 Phone:530-345-6395 Page 1 of 4
Eagle Security Systems
3268 Esplanade Ste A
Security Systems Chico,CA 95973
A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395
Form for Inspection, Testing and Maintenance of
Fire Alarms and Signaling Systems
Separate forms are available for inspection,testing,and maintenance 4.System Information
of the rest of the fire protection system of which the fire alarms and 4.1 Control Unit:
signaling systems are a part.More frequent inspection,testing,and Manufacturer: RADIONICS
maintenance may be necessary depending on the conditions of the
occupancy and the water supply. Model number: D7412GV4
Notes: 4.2 Software and Firmware Revision number: 1.00.011
1. All questions are to be answered Yes,No,or Not Applicable.All 4.3 System Power:
"No"answers are to be explained in the Comments for this form. 4.3.1 Primary(Main)Power:
2. Refer to NFPA-72 for specific inspection frequency requirements Nominal voltage: TRANSFORMER
for the different components.
1.Property Information Amps: NOT LISTED
Owner: Location: NOT LISTED
YVETTE ZUNIGA Overcurrent protection type: NOT LISTED
Owner's Phone Number: Amps: NOT LISTED
530-519-1460 Disconnecting means location: NOT LISTED
Owner's Address: 4.3.2 Secondary Power:
10381 MIDWAY.MANSION VC.CHICO.CA.95928-9599 Type: SLA 8AH(2)
Property Being Evaluated: Location: FACP
FWHA-PATRICK RANCH GLENWOOD(MANSION&VC) Battery type(if applicable): L✓J Lead-acid❑Nickel-
(Business) cadmium
❑Primary(dry cell)
Property Address: ❑Sealed lead-acid
10381 MIDWAY.MANSION VC.CHICO.CA.95928-9599 Calculated capacity of batteries to drive the system:
Assembly Description: In standby mode(hours):
Fire Alarm(RADIONICS 7412) In alarm mode(minutes):
2.Owner's Section 5.Notifications Made Prior To Testing
A.Are the fire alarms and signaling systems ✓J Yes❑No
in service?
B.Have fire alarms and signaling systems ✓J Yes❑No
remained in service since the last inspection? Monitoring Vyanet 10:02
C.Was the system(of which the fire alarm organization:
and signaling systems are a part)free of ✓J Yes❑No Building
actuation of devices or alarms since the last management: Staff 10:02
inspection?
D.The required record documents are I Building occupants: Staff 10:02
available and include the current revisions of Authority Having
all fire alarm software and the revisions of _✓I Yes❑No Jurisdiction: N/a N/a
software of any systems with which the fire
alarm software interfaces? Other,if required:
3.Monitoring Information
Monitoring organization: VYANET
OPERATING GROUP
Address: 410 SW COLUMBIA
SUITE 120
Phone: 541-241-1800
Fax:
Email: INSPECTIONS@VYA
NET.COM
Account number: 301-2832
Phone line 1: CELL
Phone line 2: CELL
Means of transmission: CELL
Entity to which alarms are retransmitted:
Phone:
NFPA 72 v1.1-2019 Page 2 of 4
01�����"'� Eagle3268Esplana Securitdy Systems
��� =� E A L E e SteA
'r-' Security Systems Chico,CA 95973
A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395
6.Testing Results 6.6 Supervising Station Monitoring
6.1 Control Unit and Related Equipment lscriptio Yes/No I i 7
Alarm signal ❑Pass❑Fail
escription Visual Functional Results ❑Yes❑No ❑✓N/A
Inspection Test
Alarm ❑Pass❑Fail
Control unit ❑d Yes❑No ❑d Yes❑No J Pass❑Fail restoration ❑Yes❑No ❑✓N/A
N/A
Lamps/LEDs/L IA Pass❑Fail Trouble signal ❑Yes❑No LJ Pass❑Fail
CDsp ❑✓Yes❑No ❑�Yes❑No ]N/A J N/A
Trouble ❑Pass❑Fail
Fuses ❑✓Yes❑No ❑�Yes ID No LJ Pass❑Fail restoration ❑Yes_I No J N/A
N/A
Trouble signals LJas❑PsFail Supervisory ❑Yes❑No ❑Pass❑Fail
Ile Yes_I No LJ Yes❑No a Li signal NA N/A
Disconnect LJ Pass❑Fail Supervisory ❑Yes❑No CI Pass❑Fail
switches LJ Yes_J No LJ Yes❑No ]N/A restoration NA N/A
6.7 Public Emergency Alarm Reporting System
Ground-fault ❑Pass❑Fail
❑Yes J No ❑Yes LJ No
monitoring ]]N/A Description [ Yes/No I I Time(seconds) Results
Supervision 0 Pass❑Fail Alarm signal ❑Pass LiFail
LJ Yes_JNo kJ Yes❑No J N/A ❑Yes❑No
_✓I N/A
Local ❑Pass❑Fail Alarm ❑Pass❑Fail
annunciator ❑Yes�I No ❑Yes LJ No J N/A ❑Yes❑No
restoration _✓I N/A
Remote ❑✓Pass❑Fail Trouble signal ❑Pass❑Fail
annunciators ❑✓Yes❑No 0 Yes❑No _I N/A ❑Yes❑No
❑✓N/A
Remote power ❑Pass❑Fail Trouble ❑Pass❑Fail
❑Yes❑✓No ❑Yes❑�/No ❑Yes❑No
panels _✓I N/A restoration ❑✓N/A
❑Pass❑Fail Supervisory ❑Pass❑Fail
Other: ❑Yes❑No ❑Yes❑No _J N/A signal ry ❑Yes❑No NAN/A
g
6.2 Secondary Power
Supervisory ❑Yes❑No LJ Pass❑Fail
Description Visual Functional Results restoration ❑✓N/A
Inspection Test 1 7.Notifications That Testing Is Complete
Battery ❑✓Yes❑No ❑O Yes❑No J Pass❑Fail Contact
condition ❑N/A
Monitoring
Load voltage ❑✓Yes❑No ❑/Yes❑No ❑✓Pass❑Fail organization: Vyanet 11:06
_J N/A
Building Staff 11:06
Discharge test ❑✓Yes❑No ❑/Yes❑No ❑✓Pass❑Fail management:
_J N/A
Charger test ❑✓Pass❑Fail Building occupants: Staff 11:06
❑✓Yes❑No ❑/Yes❑No J N/A Authority Having
Jurisdiction: N/a N/a
Remote panel ❑Pass❑Fail
batteries ❑Yes NA No ❑Yes❑�No ]N/A Other,if required:
6.3 Alarm and Supervisory Alarm Initiating Device 8.System Restored To Normal Operation
Complete supplementary device test form for all initiating devices. Date: 2/28/2025
6.4 Notification Appliances Time: 11:06
Complete supplementary appliance test form for all notification 9.Comments
appliances. Any "No"answers, test failures or other problems found with the fire
6.5 Interface Equipment alarm system must be explained using the comment specific for each
Complete supplementary interface component test form for all question.Additional comments can be added here.
interface components. Please see the summary section at the top of the form for the
Circuit Interface/Signaling Line Circuit Interface/Fire Alarm comments.
Control Interface 10.Inspector's Information
Inspected By JOSE ANTONIO
SANCHEZ LUNA
Inspector License: NICET 1 165142
I state that the information on this form is correct at the time and place
of my inspection,and that all equipment tested at this time was left in
operating condition upon completion of this inspection except as noted
in the Comments.This system as specified herein has been inspected
and tested according to NFPA 72,2016 edition,Chapter 14.
NFPA 72 v1.1-2019 Page 3 of 4
1�����"'� Eagle3268Esplana Securityd Systems
��� =� EAGLE e SteA
'
0Security Systems Chico,CA 95973
A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395
Signature of Inspector
Date 2/28/2025
11.Owner or Owner's Representative
Owner or Owner's Representative Name
Owner or Owner's Representative Signature Na Signature Available
Date 2/28/2025
NFPA 72 v1.1-2019 Page 4 of 4