HomeMy WebLinkAboutFAI15-0097 079-230-017 Feather Falls Lodge Ann FA 2.6.24 ALARM AND DETECTION REPORT Page 1 of 6 VOLTAGE' SPEcIAusTs 530-624-4514 C101C16 License#8110862 www.VoltageSpecialists.com Inspection # ALARM & DETECTION EQUIPMENT TEST REPORT Type of Inspection: Annual Date: 2/6/24 Site: Feather Falls Casino Lodge 9 customer: Feather Falls Lodge Street: 4 Alverda Drive Contact: Scott Nash City/State: OrOVille, Ca Phone#: 530-533-3855 Fax#: 1. Before Test Notify Proper Authorities: Name Phone # A. Owner or Owner's Rep Scott Nash 530-533-3855 B. Fire Department C. Central Station N/A D. Central Station Acct# 2. Control Panel Status Yes No Note # A. Is the system monitored by Central Station? I X I On Test Time: Return to Service Time: B. Is the Power Light on? X C. Does the Panel indicate Normal conditions? X D. Are all indicating Lamp Bulbs in Operator order? X E. Does the Trouble Light operate? X F. Does the Silence Switch Operate? X G. Battery A.H. 18 Date Batteries Installed: 01/06/23 1-1. Does the Panel have Non-Operational Zones? X I. Does the Panel have Battery Backup? X J. Do the batteries indicate they are Properly Charged? X Condition of Batteries: Good Note# Battery Voltage with AC Power: 27.32 Battery Voltage without AC Power: 27.30 K. List any trouble conditions on panel before test: Note# Note# Comments: Note# Note# 3. FACP Manufacturer: Fire lite Model# MS-9200 UD System Type: Addressable Location of Annunciators: Front Desk Location of Primary Power Source:Electrical room Panel# EM Breaker 23 Comments: Note# Note# FCPS: Manufacturer: Fire lite Model# FS8 Panel/Breaker# Location:Next to facp EM#22 Battery Voltage with A/C Power: 27.48 w/o A/C Power 27.46 Date: 03/21/23 FCPS: Manufacturer: Fire lite Model# fS8 Panel/Breaker# Location:3rd FL mech EM#22 Battery Voltage with A/C Power: 27.51 w/o A/C Power 27,50 Date: 03/21/23 FCPS: Manufacturer: Altronics Model# A1400 Panel/Breaker# Location:3rd FL mech EM#22 3/21/23 Battery Voltage with A/C Power: 26.12 w/o A/C Power 26.11 Date: Owner/Rep: Phone#: Date: Inspector: Wyatt C. Phone#: 530-362-2609 Date:2/6/24 Owners Rep Sign: Date:2/6/24 Inspector Sign: Panel Report Page 1A to Fire Alarm Report VOLTAGE SPECIALISTS 530-624-4514 #880862 VOLTAGE' %PECIALIsTs 530..624.4514 C101C16 License#880862 www.VoltageSpecialists.com Type of Inspection: Annual i.e.Quarterly,Annual Date: 02/06/24 Property Name: Feather falls casino lodge Street: 4 Alverda Drive Contact: Scott Nash City & State: Oroville, Ca Phone: 530-533-3855 FCPS: FCPS #1 Manufacturer: Fire Lite Model#: FS8 Panel/Breaker#: Location: Utility closet 2nd floor Battery Voltage with A/C Power: 27.69 without A/C Power 27.57 Date:4/1/22 FCPS: FCPS #2 Manufacturer: Model#: Panel/Breaker#: Location: Battery Voltage with A/C Power: without A/C Power Date: FCPS:FCPS #3 Manufacturer: Model#: Panel/Breaker#: Location: Battery Voltage with A/C Power: without A/C Power Date: FCPS: FCPS #4 Manufacturer: Model#: Panel/Breaker#: Location: Battery Voltage with A/C Power: without A/C Power Date: FCPS: FCPS #5 Manufacturer: Model#: Panel/Breaker#: Location: Battery Voltage with A/C Power: without A/C Power Date: FCPS: FCPS #6 Manufacturer: Model#: Panel/Breaker#: Location: Battery Voltage with A/C Power: without A/C Power Date: FCPS: FCPS #7 Manufacturer: Model#: Panel/Breaker#: Location: Battery Voltage with A/C Power: without A/C Power Date: FCPS: FCPS #8 Manufacturer: Model#: Panel/Breaker#: Location: Battery Voltage with A/C Power: without A/C Power Date: FCPS: FCPS #9 Manufacturer: Model#: Panel/Breaker#: Location: Battery Voltage with A/C Power: without A/C Power Date: 02/06/24 Owners Rep Sign: Date: Inspector Sign: ALARM AND DETECTION REPORT Page 2 of 6 Property Site: Feather Falls Casino Lodge l Operational #Tested This Equipment Total# Report Yes N/A Note# 4. Remote Annunciators 1 1 X 5. Zones 6. Manual Stations (Pull) Hardwire Addressable 7. Detectors Photoelectric 62 62 X Ionization Heats/Fixed or R of R 4 4 X Flame Duct(See#15) 8. Horn/Strobe Strobe Only Bell Speakers Horn 9. 10. Automatic Door Release 8 8 X 11. Water Flow switches 2 2 X Did W/F Ring Outside Bell? X Did W/F Activate Alarm Panel? X 12. Tamper Switches 5 5 X 13. PIV 1 1 X OS &Y 1 2 X 14. 15. Did test of Duct Detectors shut down air handling units? X 16. Did the Monitoring Center(Fire Dept, Central Station, Lease Line) receive signal? X 17. Is system reset for normal conditions? X 18. Is system restored to operational service? X 19. Have Proper Authorities (see#1)been notified system is back in service? X List Proper Authorities: 20. Indicate %of equipment tested this report 25% 50% 75% VJI00% 21. Indicate %of equipment tested YTD 25% 50% 75% 100% Comments for any"no"answers or explanations (Note#): 2/6/24 Owners Rep Sign: Date: Inspector Sign: ALARM AND DETECTION REPORT Page 3 of 6 Property Site: Feather Falls Casino Lodge DEVICE Zone or SLC DEVICE # TYPE DEVICE LOCATION PASS FAIL NOTE# CHANNEL Psd Main Electrical room X 1D 01 Psd 1st Floor Stairway N X 1D 02 HT Laundry room X 1D 03 HT Laundry room X 1D 04 PSD Vending area X 1D 05 PSD Registration X 1D 06 PSD Hall at main electrical X 1D 07 PSD Main lobby cntr stairs X 1D 08 PSD First floor elevator lobby X 1D 09 PSD Main lobby by pool X 1D 10 PSD Hall at manager X 1D 11 PSD Exercise room X 1D 12 PSD Hall at restroom X 1D 13 PSD Hall at room 101 X 1D 14 PSD Hall at room 108 X 1D 15 PSD Hall at room 114 X 1D 16 PSD Hall at room 120 X 1D 17 PSD Hall at room 124 X 1D 18 PSD Main Lobby ceiling X 1D 19 PSD Guest room 112 X 1D 20 PSD Guest room 111 X 1D 21 HT Old elevator machine room X 1D 22 PSD Old elevator machine room X 1D 23 PSD 2nd floor mechanical room ac X 1D 24 PSD Hall at room 200 X 1D 25 PSD Lobby mezzanine X 1D 26 PSD Main lobby ceiling X 1D 27 PSD Linen supply room X 1D 28 PSD Main lobby ceiling X 1D 29 PSD Main lobby ceiling X 1D 30 PSD 2nd floor elevator lobby X 1D 31 2/6/24 Sign:Owners RepDate: Inspector Sign: p J ALARM AND DETECTION REPORT Feather Falls Casino Lodge Page 4 of 6 DEVICE Zone or SLC DEVICE # TYPE DEVICE LOCATION PASS FAIL NOTE# CHANNEL PSD Hall outside IDF room X 1D 32 PSD Hall at room 206 X 1D 33 PSD Hall at room 212 X 1D 34 PSD Hall at room 216 X 1D 35 PSD Hall at room 220 X 1D 36 PSD Hall at room 226 X 1D 37 PSD Hall at room 230 X 1D 38 PSD Guest room 218 X 1D 39 PSD Guest room 217 X 1D 40 PSD Hall at room 301 X 1D 41 PSD 3rd floor N Stairwell X 1D 42 PSD Hall at room 304 X 1D 43 PSD 3rd floor elevator lobby X 1D 44 PSD Main lobby ceiling X 1D 45 PSD Main lobby ceiling X 1D 46 PSD Elevator 2 mechanical room X 1D 47 HT Elevator 2 mechanical room X 1D 48 PSD 3rd floor mechanical room X 1D 49 PSD 3rd floor hall mechanical room X 1D 50 PSD Hall at room 305 X 1D 51 PSD Hall at room 312 X 1D 52 PSD Hall at room 314 X 1D 53 PSD 3rd floor hall at 320 X 1D 54 PSD 3rd floor hall at 322 X 1D 55 PSD 3rd floor hall at 328 X 1D 56 PSD South stairwell X 1D 57 PSD 3rd floor room 317 X 1D 58 PSD Storage X 1D 59 PSD Vending room X 1D 60 PSD Ice room X 1D 61 PSD Guest room 109 X 1D 62 PSD Guest room 110 X 1D 63 PSD Guest room 215 X 1D 64 2/6/24 Owners Rep Sign: Date: Inspector Sign: ALARM AND DETECTION REPORT Feather Falls Casino Lodge Page 5 of 6 DEVICE Zone or SLC DEVICE # TYPE DEVICE LOCATION PASS FAIL NOTE# CHANNEL PSD Guest room 315 X 1D 65 PSD 3rd floor linen supply X 1 D 66 PSD 3rd floor maids room X 1 D 67 PS 1st Fl Stairwell North X 1M 01 PS Hallway at main electrical room X 1M 02 PS Main Lobby X 1M 04 PS Hall at restroom X 1M 06 PS South stairwell exit X 1M 08 PS 2nd fl by room 201 X 1M 12 PS 2nd fl elevator lobby X 1M 13 PS 2nd fl by room 232 X 1M 15 PS 3rd floor stairwell #1 X 1M 17 PS 3rd floor lobby X 1M 20 PS 3rd floor outside room 328 X 1M 21 MIM Dry system waterflow X 1M 03 MIM Dry system butter fly valve X 1M 05 MIM Dry riser low air X 1M 07 MIM Wet system water flow X 1M 09 MIM Wet System butterfly valve X 1M 10 MIM PIV X 1M 28 MIM OS&Y X 1M 27 MIM Fm200 active alarm X 1M 32 DD 3rd Fl mech X 1M 23 DD 2nd fl mech X 1M 24 Owners Rep Sign: Date: 2/6/24 Inspector Sign: ALARM AND DETECTION REPORT Feather Falls Casino Lodge Page 6 of 6 Zone or DEVICE DEVICE SLC # TYPE DEVICE LOCATION PASS FAIL NOTE# CHANNEL LEGEND PSD—Photoelectric Smoke Detector BD—Beam Detector H—Horn V—Visual ISD—Ionization Smoke Detector PS—Pull Station WPH—Weather Proof Horn TS—Tamper Switch PDD—Photo Duct Smoke Detector RR—Rate of Rise Heat Detector C—Chime WF—Water Flow Switch IDD—Ion Duct Smoke Detector HT—Fixed Temp Heat Detector CV—Chime Visual DH—Door Holder DHS—Door Holder&Smoke Detector FD—Flame Detector S—Speaker OSY—Outside Stem&Yoke Tamper Valve SSD—Signal Station Smoke Detector B—Bell AV—Audible Visual Ply—Post Indicator Valve Cur-Elevator Curtains FRD-Fire Rolldown Door SDC Smoke Detector&Door Holder Combo CO-Carbon Monoxide Detector - - - NOTE # COMMENT Discrepancies Found? I 1 Yes 1,1 No See Discrepancy Report? n Yes ✓ No 2/6/24 Owners Rep Sign: Date: Inspector Sign: