HomeMy WebLinkAboutFAI23-0003 025-200-127 SPIN _ SPORT CLUB_ Fire Alarm-DMP-XR 150_ 9-23-2025 (Semi-Annual) Form for Inspection, Testing and Maintenance of �1, * Security Systems Fire Alarms and Signaling Systems A VYANET OPERATING GROUP, INC.COMPANY Location Code: 045-174-5320 Contact: ERICA SANNAR Company: Eagle Security Systems Contact Address: 1788 HIGHWAY 99 Address: 3268 Esplanade Ste A GRIDLEY,CA 95948-2210 Chico,CA 95973 Phone: 530-788-6043 Company Phone: 530-345-6395 Email: DRJSANNAR@YAHOO.COM Inspector: JOSE ANTONIO SANCHEZ LUNA Property Evaluated: SPIN&SPORT CLUB(Business) NICET 1 165142 1788 HIGHWAY 99 Date of Work: 9/23/2025 GRIDLEY,CA 95948-2210 Frequency: Semi-Annual Description: Fire Alarm(DMP-XR 150) Deficiency Summary Please refer to the Deficiency Summary located on applicable Fire Alarm Supplementary Forms for additional deficiency details. General Comments There are no general comments for this submission Eagle Security Systems,3268 Esplanade Ste A,Chico,CA,95973 Phone:530-345-6395 Page 1 of 4 Eagle Security Systems 3268 Esplanade Ste A Security Systems Chico,CA 95973 A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395 Form for Inspection, Testing and Maintenance of Fire Alarms and Signaling Systems Separate forms are available for inspection,testing,and maintenance 4.System Information of the rest of the fire protection system of which the fire alarms and 4.1 Control Unit: signaling systems are a part.More frequent inspection,testing,and Manufacturer: DMP maintenance may be necessary depending on the conditions of the occupancy and the water supply. Model number: XR150 Notes: 4.2 Software and Firmware Revision number: 212 1. All questions are to be answered Yes,No,or Not Applicable.All 4.3 System Power: "No"answers are to be explained in the Comments for this form. 4.3.1 Primary(Main)Power: 2. Refer to NFPA-72 for specific inspection frequency requirements Nominal voltage: 120 for the different components. 1.Property Information Amps: 20 Owner: Location: OFFICE ERICA SANNAR Overcurrent protection type: TRANSFORMER Owner's Phone Number: Amps: 20 530-788-6043 Disconnecting means location: BELOW PANEL Owner's Address: 4.3.2 Secondary Power: 1788 HIGHWAY 99.GRIDLEY.CA.95948-2210 Type: BATTERY Property Being Evaluated: Location: FACU SPIN&SPORT CLUB(Business) Battery type(if applicable): ❑Lead-acid❑Nickel- cadmiumPro e Address: Property ❑Primary(dry cell) 1788 HIGHWAY 99.GRIDLEY.CA.95948-2210 ❑✓Sealed lead-acid Assembly Description: Calculated capacity of batteries to drive the system: Fire Alarm(DMP-XR 1501 In standby mode(hours): 24.0 2.Owner's Section In alarm mode(minutes): 5.0 A.Are the fire alarms and signaling systems ]Yes El No 5.Notifications Made Prior To Testing in service? B.Have fire alarms and signaling systems ❑✓Yes❑No remained in service since the last inspection? C.Was the system(of which the fire alarm Monitoring Vyanet 8:56 and signaling systems are a part)free of organization: actuation of devices or alarms since the last ]Yes El No Building Staff 8:56 inspection? management: D.The required record documents are available and include the current revisions of I Building occupants: I Staff 8:56 all fire alarm software and the revisions of Yes❑No Authority Having software of any systems with which the fire Jurisdiction: N/a N/a alarm software interfaces? 3.Monitoring Information Other,if required: Monitoring organization: VYANET OPERATING GROUP, INC Address: 410 SW COLUMBIA STREET;STE 120, BEND OR 97702 Phone: 541-241-1800 Fax: Email: INSPECTIONS@VYA NET.COM Account number: 174-5320 Phone line 1: Phone line 2: Means of transmission: CELLULAR COMMUNICATOR Entity to which alarms are retransmitted: Phone: NFPA 72 v1.1-2019 Page 2 of 4 01�����"'� Eagle3268Esplana Securitdy Systems ��� =� E A L E e Ste A 'r-' Security Systems Chico,CA 95973 A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395 6.Testing Results 6.6 Supervising Station Monitoring 6.1 Control Unit and Related Equipment lscriptio Yes/No I i 7 Alarm signal ❑Pass❑Fail escription Visual Functional Results ❑Yes❑No ❑✓N/A Inspection Test Alarm ❑Pass❑Fail Control unit ❑d Yes❑No ❑d Yes❑No J Pass❑Fail restoration ❑Yes❑No ❑✓N/A N/A Lamps/LEDs/L IA Pass❑Fail Trouble signal ❑Yes❑No ❑Pass❑Fail CDsp ❑✓Yes❑No ❑�Yes❑No ]N/A NA N/A Trouble ❑Pass❑Fail Fuses ❑✓Yes❑No ❑�Yes ID No L✓J Pass❑Fail restoration ❑Yes_I No NA N/A N/A Trouble signals L✓Jas❑PsFail Supervisory ❑Yes❑No ❑Pass❑Fail Ile Yes_I No L_l Yes❑No a Li signal NA N/A Disconnect ❑Pass❑Fail Supervisory ❑Yes❑No ❑Pass❑Fail switches ❑Yes J No ❑Yes[ No NA N/A restoration NA N/A 6.7 Public Emergency Alarm Reporting System Ground-fault ❑Pass❑Fail ❑Yes J No ❑Yes LJ No monitoring ]]N/A Description [ Yes/No I I Time(seconds) Results Supervision 0 Pass❑Fail Alarm signal ❑Pass❑Fail L✓JYes❑No L�Yes❑No _I N/A ❑Yes❑No _✓I N/A Local ❑Pass❑Fail Alarm ❑Pass❑Fail annunciator ❑Yes�I No ❑Yes LJ No J N/A ❑Yes❑No restoration _✓I N/A Remote ❑✓Pass❑Fail Trouble signal ❑Pass❑Fail annunciators ❑✓Yes❑No ❑/Yes❑No _I N/A ❑Yes❑No ❑✓N/A Remote power ❑Pass❑Fail Trouble ❑Pass❑Fail ❑Yes❑✓No ❑Yes❑�/No ❑Yes❑No panels _✓I N/A restoration ❑✓N/A ❑Pass❑Fail Supervisory ❑Pass❑Fail Other: ❑Yes❑No ❑Yes❑No _I N/A signal ry ❑Yes❑No NA'N/A g 6.2 Secondary Power Supervisory ❑Yes❑No ❑Pass❑Fail Description Visual Functional Results restoration ❑✓N/A Inspection Test 1 7.Notifications That Testing Is Complete Battery ❑✓Yes❑No ❑O Yes❑No NA PPass❑Fail Contact condition ❑N/A Monitoring Load voltage ❑✓Yes❑No ❑/Yes❑No ❑✓Pass❑Fail organization: Vyanet 9:15 ❑N/A Building Staff 9:15 Discharge test ❑✓Yes❑No ❑/Yes❑No ❑✓Pass❑Fail management: ❑N/A Charger test ❑✓Pass❑Fail Building occupants: Staff 9:15 ❑✓Yes❑No ❑/Yes❑No ]N/A Authority Having Jurisdiction: N/a N/a Remote panel ❑Pass❑Fail batteries ❑Yes NA No CI Yes❑�No ]N/A Other,if required: 6.3 Alarm and Supervisory Alarm Initiating Device 8.System Restored To Normal Operation Complete supplementary device test form for all initiating devices. Date: 9/23/2025 6.4 Notification Appliances Time: 9:15 Complete supplementary appliance test form for all notification 9.Comments appliances. Any "No"answers, test failures or other problems found with the fire 6.5 Interface Equipment alarm system must be explained using the comment specific for each Complete supplementary interface component test form for all question.Additional comments can be added here. interface components. Please see the summary section at the top of the form for the Circuit Interface/Signaling Line Circuit Interface/Fire Alarm comments. Control Interface 10.Inspector's Information Inspected By JOSE ANTONIO SANCHEZ LUNA Inspector License: NICET 1 165142 I state that the information on this form is correct at the time and place of my inspection,and that all equipment tested at this time was left in operating condition upon completion of this inspection except as noted in the Comments.This system as specified herein has been inspected and tested according to NFPA 72,2019 edition,Chapter 14. NFPA 72 v1.1-2019 Page 3 of 4 1�����"'� Eagle3268Esplana Securityd Systems ��� =� EAGLE e SteA ' 0Security Systems Chico,CA 95973 A VYANET OPERATING GROUP,INC.COMPANY Phone:530-345-6395 Signature of Inspector Date 9/23/2025 11.Owner or Owner's Representative Owner or Owner's Representative Name Owner or Owner's Representative Signature Na Signature Available Date 9/23/2025 NFPA 72 v1.1-2019 Page 4 of 4