Loading...
HomeMy WebLinkAbout009-340-168 EH-WWP-25-000120 REVISED SITE PLAN 12.22.25SHEET INDEX Title PageG-1 Contacts, Inspection, General NotesG-2 Distribution Field and DetailsD-4 Additional DetailsD-5 D-1 Dosing Tank and Details Hydraulics; Distribution FieldH-2 G-3 System Schematic Attachments (Soil Data) G-1TITLE SHEET EQUA ENGINEERING 591 OBRIEN AVE GRIDLEY, CA 95948 PHONE (530) 632-6605 CONSULTANTS ENGINEERS SURVEYORS RCE 69021 Sht No. ADVANTEX TREATMENT UNIT NON-STANDARD SEWAGE DISPOSAL SYSTEM 11-5-2025 PROJECTS PLANS YUBA COUNTY FOR THE: FOR CONSTRUCTION OF A: VICINITY MAP No Scale JAMES CRIDDLE MACEDO ROAD GRIDLEY, CA 95948 APN: 0009-340-150 PM 2024-0005 PARCEL #2 BUTTE COUNTY 3 BEDROOM HOUSE NOTES G-2CONTACTS, INSPECTION, & GENERAL NOTES CONTACTS AND INSPECTION EQUA ENGINEERINGCONSULTANTSENGINEERSCONTRACTORS JA M E S C R I D D L E MA C E D O R O A D AP N : 0 0 9 - 3 4 0 - 1 5 0 P M 2 0 2 4 - 0 5 L O T # 2 GR I D L E Y , C A 9 5 9 4 8 OVERALL SITE MAP 1"=40'SOILS MAP DISTRIBUTION FIELDsee Sheet D-4 see Sheet D-1 EQUA ENGINEERINGCONSULTANTSENGINEERSCONTRACTORS MACEDO ROAD SEPTIC & DOSING TANK & ADVANTEX FILTER PROPOSED HOUSE Two Leach Lines @ 87' each PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E JA M E S C R I D D L E MA C E D O R O A D AP N : 0 0 9 - 3 4 0 - 1 5 0 P M 2 0 2 4 - 0 5 L O T # 2 GR I D L E Y , C A 9 5 9 4 8 CALCULATIONS: 3 BEDROOMS X 150 GALLONS PER ROOM = 450 GALLONS 450 GALLONS / (0.9 GALLONS PER SQUARE FOOT X 3 FEET) =167 FEET 2 LEACH LINES => 167 / 2 = 83.5' USE 87' FOR LEACH LINES DISTRIBUTION FIELD; HYDRAULIC CHARACTERISTICS H-2HYDRAULICS; DISTRIBUTION FIELD OSI PUMP CURVE for Distribution Field Dose EQUA ENGINEERINGCONSULTANTSENGINEERSCONTRACTORSHOUSE HYDRAULICS HOUSE HYDRAULICS SUMMARY JA M E S C R I D D L E MA C E D O R O A D AP N : 0 0 9 - 3 4 0 - 1 5 0 P M 2 0 2 4 - 0 5 L O T # 2 GR I D L E Y , C A 9 5 9 4 8 The water tight septic tank shall be a minimum SEE SIZES BELOW. All installation shall follow the Uniform Plumbing Code (latest edition) unless otherwise noted. RECIRCULATE TANK DOSING TANK The water tight dose tank shall be a SEE SIZES BELOW septic tank or an approved IAMPO tank and meet the construction requirements of the UPC. D-1DOSING TANK AND DETAILS CONSULT OWNER REGARDING LOCATION OF PANEL (SIDE OF HOUSE, 75' Max., OR POST MOUNTED NEXT TO ACCESS RISERS.) PROVIDE CONDUIT AND PULL ROPE BETWEEN HOUSE ELEC. STUB AND CONTROL PANEL. LEVEL CONTROL FLOAT ASSEMBLY EQUA ENGINEERINGCONSULTANTSENGINEERSCONTRACTORS NOT TO SCALE TRANSMISSION LINE 12" FLEX HOSE CHECK VALVE ALARM ON 2" MIN. NOT TO SCALE FROM HOSUE X Y Z C E OSI PUMP ASSEMBLY H OSI DISCHARGE ASSEMBLY (flow controller removed) MAX. LIQUID LEVEL STORAGE OFF OSI LEVEL CONTROL FLOAT ASSEMBLY F OSI PUMP VAULT AT INLET SOFFIT CONDUIT SEAL CONDUIT TO CONTROL PANEL D G J K NOTE: SLOPE GROUND AWAY FROM RISER (8) 1-3/8" DIA. INLET HOLES AROUND PERIMETER OF VAULT MERRILL & SONS OR AN IAMPO APPROVED WATER TIGHT TANK FLOAT SETTINGS (NO SCALE) OSI PUMP/ALARM CONTROL PANEL (ADVANTEX FILTER AND DISTRIBUTION FIELD) U OSI SPLICE BOX WITH CORD GRIPS. MOUNT ON RISER WALL OR OTHER APPROVED LOCATION. 24" DIA. RIBBED PVC RISER WITH NEOPRENE GROMMETS. 2" 5" DISCHARGE LINE FROM ADVANTEX TO DOSE TANK NOTE: RISER HEIGHTS TO BE DETERMINED BY CONTRACTOR BASED ON SITE CONDITIONS. 1,500 GALLON RECIRCULATE TANK 1,500 GALLON DOSE TANK HOUSE SEPTIC / DOSING TANK CRITERIA JA M E S C R I D D L E MA C E D O R O A D AP N : 0 0 9 - 3 4 0 - 1 5 0 P M 2 0 2 4 - 0 5 L O T # 2 GR I D L E Y , C A 9 5 9 4 8 D-4DISTRIBUTION FIELD AND DETAILS NO SCALE DISTRIBUTION SYSTEM (Top View) BALANCING VALVE DETAIL NO SCALE 3 B B/2 3' min K EQUA ENGINEERINGCONSULTANTSENGINEERSCONTRACTORS NO SCALE TRENCH SECTION TYP.2 2.5" J H F 10' G ED 6.5" 12" 36" PURGE VALVE DETAIL NO SCALE 1 B/2 TRENCH DEPTH FROM OG = 19" HOUSE HYDRAULICS JA M E S C R I D D L E MA C E D O R O A D AP N : 0 0 9 - 3 4 0 - 1 5 0 P M 2 0 2 4 - 0 5 L O T # 2 GR I D L E Y , C A 9 5 9 4 8 D-5ADDITIONAL DETAILS STANDARD ORFICE SHIELD DETAIL NO SCALE Monitoring Well Location 4" MONITORING WELL NO SCALE EQUA ENGINEERINGCONSULTANTSENGINEERSCONTRACTORS JA M E S C R I D D L E MA C E D O R O A D AP N : 0 0 9 - 3 4 0 - 1 5 0 P M 2 0 2 4 - 0 5 L O T # 2 GR I D L E Y , C A 9 5 9 4 8