HomeMy WebLinkAbout007-230-014 EHS15-0097 Residential Supplemental Treatment Onsite System Evaluation and Maintenance ReportSite Address:
Owner:
Mailing:
Owners Phone:
Evaluator:for Hydrotec
TANK #1 (Gravity)
Tank Volume:Gals.7 Inches
X Yes No X Good Fair Poor
High X Normal Low
X Good Fair Poor
X Yes No N/A Scum:0 Inches Sludge:11 Inches
X Yes No N/A Scum:0 Inches Sludge:7 Inches
X Good Fair Poor N/A
X Yes No Yes X No
TANK #2 STEP
Tank Volume:Gals.15 Inches
X Yes No X Good Fair Poor
High X Normal Low
X Good Fair Poor
X Yes No N/A Scum:0 Inches Sludge:6 Inches
X Yes No N/A Scum:0 Inches Sludge:4 Inches
X Good Fair Poor N/A
Yes X No Yes X No
X Yes No
Yes No Good Poor
X Yes No Alarms: Audible Visual
EC ETM HLA OVR
Yes X No
Hydraulic Load Test:Excellent Good
Poor X
X Dry Ponding N/A
Yes X No Yes X No
Yes X No Yes X No
Yes X No Yes X No
Comments and System Map on Back ]HS,I-STEP8/11
Tank was Cleaned:
Tank was Cleaned:
Inlet Tee:
Outlet Tee:
Baffle Condition:
Pumping Required:
1500 Depth to Access Lid:
Access Risers:Condition:
Liquid Operating Level:
Tank Material:Concrete Structural Condition:
Bacteria Action:
836:56:00
Type of Filter:
Control Panel:
Well on Property:Effluent Line D.Valve:
Type of Absorption Field:
All Floats Operating?
Satisfactory
Pressure Dosed
10.7 119.8
Marginal
N/A
Graywater:
Surfacing Effluent:
# Occupants:
4229 Caballo Wy, Chico, CA 95973
S.T.E.P. System
Eval. Date:
Barbara White
12/2/25
HYDROTEC SOLUTIONS
P.O. Box 7908, Chico, CA 95927
(530) 891-4420, FAX: (530) 891-4426
Residential Supplemental Treatment Onsite System Evaluation and Maintenance Report
715 Park View Ave. #1, Redding, CA 96001
R. Belcher
530-224-2800
Down Slope Seepage:
Saturated Field:
Multiple Systems:
Pump:
1120Pump:33483
Piezometers:
FAILURE Not Applicable
Running AMPS:Running Voltage:
1500 Depth to Access Lid:
Liquid Operating Level:
Access Risers:
Tank Material:Concrete
Condition:
Structural Condition:
Inlet Tee:
Outlet Tee:
Baffle Condition:
Pumping Required:
Pump, Vault & Filter Cleaned?
SEPTIC TANK:
ABSORPTION TRENCHES:
Evaluator Signature Date:
N l
x < Panel
C D
A R 15'
B I
A V
L E O I O O I P < STEP
L W 11'^GRAVITY 27'
O A
Y
HOME
W
A
Y u
l Piezos
4229 Caballo Wy.
HS,I-STEP11/19
ALL FLUSHOUTS
hydrojetting. We found no other problems at this time.
PARCEL ADDRESS:
The #3 & #4 laterals are packed with sand and could not flush, suggest
COMMENTS / OBSERVATIONS
time.
life of this system.
There is some exposed aggregate in both tanks. We found no other problems at this
SHED
PATIO
lmlmmlml
FIELD
LOCATION OF SEPTIC TANK & ABSORPTION FIELD
This onsite wastewater treatment and disposal system evaluation report is a true and complete record of the onsite waste-
water treatment and disposal system on the date of the evaluation. No warranty is given or implied regarding the remaining
12/2/25
I certify that this onsite wastewater treatment and disposal system evaluation report reflects conditions observed on the
parcel (s) during the routine maintenance of the onsite wastewater treatment and disposal system.
R. Belcher