HomeMy WebLinkAbout007-230-027 EHWWOP-254-00027 4394 Caballo 2025 OM&M CHECK LISTSite Address:
Owner:
Mailing:
Owners Phone:
Evaluator:for Hydrotec
TANK #1 (Gravity)
Tank Volume:Gals.6 Inches
X Yes No X Good Fair Poor
High X Normal Low
X Good Fair Poor
X Yes No N/A Scum:1 Inches Sludge:6 Inches
X Yes No N/A Scum:0 Inches Sludge:3 Inches
X Good Fair Poor N/A
Yes X No Yes X No
TANK #2 STEP
Tank Volume:Gals.12 Inches
X Yes No X Good Fair Poor
High X Normal Low
X Good Fair Poor
X Yes No N/A Scum:0 Inches Sludge:3 Inches
Yes No X N/A Scum:0 Inches Sludge:2 Inches
X Good Fair Poor N/A
Yes X No Yes X No
X Yes No
X Yes No X Good Poor
X Yes No Alarms: X Audible X Visual
EC ETM HLA OVR
Yes X No
Hydraulic Load Test:X Excellent Good
Poor
X Dry Ponding N/A
Yes X No Yes X No
Yes X No Yes X No
Yes X No Yes X No
Comments and System Map on Back ]HS,I-STEP8/11
Concrete Structural Condition:
Well on Property:Effluent Line D.Valve:
Type of Absorption Field:
Tank was Cleaned:
Tank was Cleaned:
Inlet Tee:
Outlet Tee:
Baffle Condition:
Pumping Required:
1500 Depth to Access Lid:
Access Risers:Condition:
Liquid Operating Level:
Tank Material:
E-Z Pack
Bacteria Action:
8:45:00
Type of Filter:
Control Panel:
All Floats Operating?
Satisfactory
Presby
10.64 118.4
Marginal
5
Graywater:
Surfacing Effluent:
# Occupants:
4394 Caballo Wy., Chico, CA 95973
S.T.E.P. System
Eval. Date:
Sharon Corbitt (Corbitt Family Trust)
12/15/25
HYDROTEC SOLUTIONS
P.O. Box 7908, Chico, CA 95927
(530) 891-4420, FAX: (530) 891-4426
Residential Supplemental Treatment Onsite System Evaluation and Maintenance Report
Same
G. Tuter
530-321-2889
Down Slope Seepage:
Saturated Field:
Multiple Systems:
Pump:
12Pump:586
Piezometers:
FAILURE Not Applicable
Running AMPS:Running Voltage:
1500 Depth to Access Lid:
Liquid Operating Level:
Access Risers:
Tank Material:Concrete
Condition:
Structural Condition:
Inlet Tee:
Outlet Tee:
Baffle Condition:
Pumping Required:
Pump, Vault & Filter Cleaned?
SEPTIC TANK:
ABSORPTION TRENCHES:
Evaluator Signature Date:
N f
C
A
B
A
L
L
O
u
l <--PIEZOMETERS
W m <--OBSERVATION PORT
A n <--VENT
Y i
l l
PANEL
i
x n
m
GRAV ->O I O l l
O I P&F
^STEP
4394 Caballo Wy.
HS,I-STEP11/19
PARCEL ADDRESS:
We found no problems at this time.
COMMENTS / OBSERVATIONS
life of this system.
We found no problems at this time.
MOBLE HOME
DRIVE WAY
FIELD
LOCATION OF SEPTIC TANK & ABSORPTION FIELD
This onsite wastewater treatment and disposal system evaluation report is a true and complete record of the onsite waste-
water treatment and disposal system on the date of the evaluation. No warranty is given or implied regarding the remaining
12/15/25
I certify that this onsite wastewater treatment and disposal system evaluation report reflects conditions observed on the
parcel (s) during the routine maintenance of the onsite wastewater treatment and disposal system.
G. Tuter