Loading...
HomeMy WebLinkAbout007-230-027 EHWWOP-254-00027 4394 Caballo 2025 OM&M CHECK LISTSite Address: Owner: Mailing: Owners Phone: Evaluator:for Hydrotec TANK #1 (Gravity) Tank Volume:Gals.6 Inches X Yes No X Good Fair Poor High X Normal Low X Good Fair Poor X Yes No N/A Scum:1 Inches Sludge:6 Inches X Yes No N/A Scum:0 Inches Sludge:3 Inches X Good Fair Poor N/A Yes X No Yes X No TANK #2 STEP Tank Volume:Gals.12 Inches X Yes No X Good Fair Poor High X Normal Low X Good Fair Poor X Yes No N/A Scum:0 Inches Sludge:3 Inches Yes No X N/A Scum:0 Inches Sludge:2 Inches X Good Fair Poor N/A Yes X No Yes X No X Yes No X Yes No X Good Poor X Yes No Alarms: X Audible X Visual EC ETM HLA OVR Yes X No Hydraulic Load Test:X Excellent Good Poor X Dry Ponding N/A Yes X No Yes X No Yes X No Yes X No Yes X No Yes X No Comments and System Map on Back ]HS,I-STEP8/11 Concrete Structural Condition: Well on Property:Effluent Line D.Valve: Type of Absorption Field: Tank was Cleaned: Tank was Cleaned: Inlet Tee: Outlet Tee: Baffle Condition: Pumping Required: 1500 Depth to Access Lid: Access Risers:Condition: Liquid Operating Level: Tank Material: E-Z Pack Bacteria Action: 8:45:00 Type of Filter: Control Panel: All Floats Operating? Satisfactory Presby 10.64 118.4 Marginal 5 Graywater: Surfacing Effluent: # Occupants: 4394 Caballo Wy., Chico, CA 95973 S.T.E.P. System Eval. Date: Sharon Corbitt (Corbitt Family Trust) 12/15/25 HYDROTEC SOLUTIONS P.O. Box 7908, Chico, CA 95927 (530) 891-4420, FAX: (530) 891-4426 Residential Supplemental Treatment Onsite System Evaluation and Maintenance Report Same G. Tuter 530-321-2889 Down Slope Seepage: Saturated Field: Multiple Systems: Pump: 12Pump:586 Piezometers: FAILURE Not Applicable Running AMPS:Running Voltage: 1500 Depth to Access Lid: Liquid Operating Level: Access Risers: Tank Material:Concrete Condition: Structural Condition: Inlet Tee: Outlet Tee: Baffle Condition: Pumping Required: Pump, Vault & Filter Cleaned? SEPTIC TANK: ABSORPTION TRENCHES: Evaluator Signature Date: N f C A B A L L O u l <--PIEZOMETERS W m <--OBSERVATION PORT A n <--VENT Y i l l PANEL i x n m GRAV ->O I O l l O I P&F ^STEP 4394 Caballo Wy. HS,I-STEP11/19 PARCEL ADDRESS: We found no problems at this time. COMMENTS / OBSERVATIONS life of this system. We found no problems at this time. MOBLE HOME DRIVE WAY FIELD LOCATION OF SEPTIC TANK & ABSORPTION FIELD This onsite wastewater treatment and disposal system evaluation report is a true and complete record of the onsite waste- water treatment and disposal system on the date of the evaluation. No warranty is given or implied regarding the remaining 12/15/25 I certify that this onsite wastewater treatment and disposal system evaluation report reflects conditions observed on the parcel (s) during the routine maintenance of the onsite wastewater treatment and disposal system. G. Tuter