Loading...
HomeMy WebLinkAboutFAI23-0003 025-200-127 SPIN _ SPORT CLUB_ Fire Alarm Inspection 1-27-26Inspection Summary This is to certify that our representative has inspected the equipment noted below and that he has left the equipment in operating condition. There is available in our file, a complete record of conditions as found and all repairs made and recommended. ALARM SUMMARY TYPES TECHNICIAN QTY INSPECTED QTY FAILED DATE INSPECTED DMP-XR 150 Nicholas Ray 1 0 01-27-2026 Tamper Switch Nicholas Ray 1 0 01-27-2026 Smoke Nicholas Ray 1 0 01-27-2026 Water Flow Alarm Nicholas Ray 1 0 01-27-2026 Bell Nicholas Ray 1 0 01-27-2026 Report of Inspection / Test Annual NFPA 72 01-27-2026 Property SPIN & SPORT CLUB (366-5320) 366-5320 1788 HIGHWAY 99 GRIDLEY CA 95948-2210 Print Date: 01-28-2026 Conducted by: Nicholas Ray 160298 NICET Ill Eagle Security C-10#1053224, ACO7862 2700 Hegan Ln Chico CA 95928 530-345-6395 Inspections@vyanet.com Copyright 2026 Inspect Point Deficiencies - DMP-XR 150 None Report of Inspection / Test Annual NFPA 72 01-27-2026 Property SPIN & SPORT CLUB (366-5320) 366-5320 1788 HIGHWAY 99 GRIDLEY CA 95948-2210 Print Date: 01-28-2026 Conducted by: Nicholas Ray 160298 NICET Ill Eagle Security C-10#1053224, ACO7862 2700 Hegan Ln Chico CA 95928 530-345-6395 Inspections@vyanet.com Copyright 2026 Inspect Point Page 1 of 7 Inspection and Testing Form - DMP-XR 150 Approving Agency Contact Name N/A Telephone N/A Email N/A Service Type N/A Power Supply Main Nominal Voltage N/A Main Nominal Amps N/A Overcurrent Protection N/A Panel Board Location N/A Disconnecting Means Location N/A Secondary Standby N/A Storage Battery: Amp Hour Rating N/A Calculated Capacity to operate system (Hours) N/A Engine-driven generator dedicated to fire alarm system N/A Location of fuel storage N/A Has Emergency System described in NFPA 70, Article 700 N/A Has Legally required standby described in NFPA 70, Article 701 N/A Has Optional standby system described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701 N/A Report of Inspection / Test Annual NFPA 72 01-27-2026 Property SPIN & SPORT CLUB (366-5320) 366-5320 1788 HIGHWAY 99 GRIDLEY CA 95948-2210 Print Date: 01-28-2026 Conducted by: Nicholas Ray 160298 NICET Ill Eagle Security C-10#1053224, ACO7862 2700 Hegan Ln Chico CA 95928 530-345-6395 Inspections@vyanet.com Copyright 2026 Inspect Point Page 2 of 7 NOTIFICATIONS MADE PRIOR TO ANY TESTING Yes No N/A Who Time Monitoring Entity Vyanet 1045 Building Occupants Erica 1045 Building Management Erica 1045 Other (Specify) AHJ Notified of Any Impairments  SYSTEM TESTS AND INSPECTIONS Visual Functional Pass/Fail Comments Supervision No Yes Pass Local Annunciator N/A N/A N/A Remote Annunciator Yes Yes Pass Power Extender Panels N/A N/A N/A Isolation Modules N/A N/A N/A Sound Pressure Level- Ambient N/A N/A N/A Sound Pressure Level- Alarm N/A N/A N/A System Intelligibility - CSI N/A N/A N/A System Intelligibility - STI N/A N/A N/A Functional Test No Yes Pass Reset/Power down Test No Yes Pass UPS Power Test N/A N/A N/A CCU Security Mechanism N/A N/A N/A Prerecorded Message Content N/A N/A N/A Prerecorded Message Activation N/A N/A N/A Software Backup Performed N/A N/A N/A Test Backup Software N/A N/A N/A Fire Alarm to MNS Interface N/A N/A N/A MNS to Fire Alarm Interface N/A N/A N/A In-building MNS to wide area MNS N/A N/A N/A MNS to direct recipient MNS N/A N/A N/A Other (Specify)N/A N/A N/A SECONDARY POWER Visual Functional Pass/Fail Comments Report of Inspection / Test Annual NFPA 72 01-27-2026 Property SPIN & SPORT CLUB (366-5320) 366-5320 1788 HIGHWAY 99 GRIDLEY CA 95948-2210 Print Date: 01-28-2026 Conducted by: Nicholas Ray 160298 NICET Ill Eagle Security C-10#1053224, ACO7862 2700 Hegan Ln Chico CA 95928 530-345-6395 Inspections@vyanet.com Copyright 2026 Inspect Point Page 3 of 7 Battery Condition Yes Yes Pass Load Voltage No Yes Pass Discharge Test No Yes Pass Charger Test No Yes Pass Specific Gravity N/A N/A N/A Transient Suppressors N/A N/A N/A Remote Annunciators N/A N/A N/A NOTIFICATION APPLIANCES Visual Functional Pass/Fail Comments Audible Yes Yes Pass Visual N/A N/A N/A Speakers N/A N/A N/A Voice Clarity N/A N/A N/A EMERGENCY COMMUNICATION EQUIPMENT Visual Functional Pass/Fail Comments Phone Set N/A N/A N/A Phone Jacks N/A N/A N/A Off-Hook Indicator N/A N/A N/A Amplifier(s)N/A N/A N/A Tone Generator(s)N/A N/A N/A Call-in Signal N/A N/A N/A System Performance N/A N/A N/A System Audibility N/A N/A N/A System Intelligibility N/A N/A N/A Radio Communication Enhancement System N/A N/A N/A Area of Refuge Communication System N/A N/A N/A Elevator Emergency Communication System N/A N/A N/A Other (Specify)N/A N/A N/A SUPERVISING STATION MONITORING Yes No N/A Who Time Alarm Signal Vyanet Alarm Restoration Vyanet Report of Inspection / Test Annual NFPA 72 01-27-2026 Property SPIN & SPORT CLUB (366-5320) 366-5320 1788 HIGHWAY 99 GRIDLEY CA 95948-2210 Print Date: 01-28-2026 Conducted by: Nicholas Ray 160298 NICET Ill Eagle Security C-10#1053224, ACO7862 2700 Hegan Ln Chico CA 95928 530-345-6395 Inspections@vyanet.com Copyright 2026 Inspect Point Page 4 of 7 Supervisory Signal Vyanet Supervisory Restoration Vyanet Trouble Restoral Vyanet NOTIFICATIONS THAT TESTING IS COMPLETE Yes No N/A Who Time Monitoring Agency Vyanet 1125 Building Occupants Erica 1125 Building Management Erica 1125 AHJ Notified of Any Impairments  Other (Specify) Report of Inspection / Test Annual NFPA 72 01-27-2026 Property SPIN & SPORT CLUB (366-5320) 366-5320 1788 HIGHWAY 99 GRIDLEY CA 95948-2210 Print Date: 01-28-2026 Conducted by: Nicholas Ray 160298 NICET Ill Eagle Security C-10#1053224, ACO7862 2700 Hegan Ln Chico CA 95928 530-345-6395 Inspections@vyanet.com Copyright 2026 Inspect Point Page 5 of 7 INITIATING, SUPERVISORY, AND NOTIFICATION DEVICE TESTS AND INSPECTIONS Address Location Device Type Factory Setting Measured Setting Visual Functional Pass/Fail 8 Riser tamper TAMPER SWITCH Yes Yes Pass 10 FACU SMOKE Yes Yes Pass 1 Riser Exterior BELL Yes Yes Pass 9 Waterflow WATER FLOW ALARM Yes Yes Pass Report of Inspection / Test Annual NFPA 72 01-27-2026 Property SPIN & SPORT CLUB (366-5320) 366-5320 1788 HIGHWAY 99 GRIDLEY CA 95948-2210 Print Date: 01-28-2026 Conducted by: Nicholas Ray 160298 NICET Ill Eagle Security C-10#1053224, ACO7862 2700 Hegan Ln Chico CA 95928 530-345-6395 Inspections@vyanet.com Copyright 2026 Inspect Point Page 6 of 7 Inspector Signature I state that the information on this form is correct at the time and place of my inspection, and all equipment tested at this time was left in operational condition upon completion of this inspection except as noted. Inspector Name Signature Date Completed Nicholas Ray 160298 NICET Ill 2026-01-27 Report of Inspection / Test Annual NFPA 72 01-27-2026 Property SPIN & SPORT CLUB (366-5320) 366-5320 1788 HIGHWAY 99 GRIDLEY CA 95948-2210 Print Date: 01-28-2026 Conducted by: Nicholas Ray 160298 NICET Ill Eagle Security C-10#1053224, ACO7862 2700 Hegan Ln Chico CA 95928 530-345-6395 Inspections@vyanet.com Copyright 2026 Inspect Point Page 7 of 7