Loading...
HomeMy WebLinkAbout002-040-013 step evaluation and maintenance report 2.9.26 1775 Estates Way 2025Site Address: Owner: Mailing: Owners Phone: Evaluator:for Hydrotec Tank Volume:Gals.36 Inches X Yes No X Good Fair Poor High X Normal Low X Good Fair Poor X Yes No N/A Scum:0 Inches Sludge:6 Inches Yes No X N/A Scum:0 Inches Sludge:4 Inches Good Fair Poor X N/A Yes X No Yes X No X Yes No X Yes No X Good Poor X Yes No Alarms: X Audible X Visual EC ETM HLA LLA Yes X No Hydraulic Load Test:X Excellent Good Poor X Dry Ponding N/A Yes X No Yes X No Yes X No Yes X No Yes X No Yes X No Comments and System Map on Back ]HS,I-STEP8/11 Satisfactory Pressure 11.48 Marginal 257:41:00 Type of Filter: 28 Graywater: Running Voltage: EZ-Pak Bio-tube Bacteria Action: Surfacing Effluent: Effluent Line D.Valve: Type of Absorption Field: Well on Property: Control Panel: 7805 Depth to Access Lid: HYDROTEC SOLUTIONS P.O. Box 7908, Chico, CA 95927 (530) 891-4420, FAX: (530) 630-6000 Residential Supplemental Treatment Onsite System Evaluation and Maintenance Report same 12/23/25 N/A 1775 Estates Way, Chico, CA 95928 S.T.E.P. System Eval. Date: Jodi Heithecker G. Tuter 530-519-4773 # Occupants: 1500 Piezometers: FAILURE Not Applicable Running AMPS: Inlet Tee: Condition: Structural Condition: Access Risers: Liquid Operating Level: Tank Material:Concrete 121.1 Outlet Tee: Baffle Condition: Pumping Required: All Floats Operating? Tank was Cleaned: Pump, Vault & Filter Cleaned? Down Slope Seepage: Saturated Field: Multiple Systems: Pump: 7Pump: SEPTIC TANK: ABSORPTION TRENCHES: Evaluator Signature Date: N h Fence Line E Pump->O | O S T A Leach lines in driveway T E l S hi Piezometers l W A HOUSE Y DRIVEWAY 2nd tank O | O x <--Panel GARAGE 1775 Estates Way HS,I-STEP8/11 PARCEL ADDRESS: We found no problems at this time. COMMENTS / OBSERVATIONS We found no problems at this time. LOCATION OF SEPTIC TANK & ABSORPTION FIELD This onsite wastewater treatment and disposal system evaluation report is a true and complete record of the onsite waste- water treatment and disposal system on the date of the evaluation. No warranty is given or implied regarding the remaining 12/23/25 I certify that this onsite wastewater treatment and disposal system evaluation report reflects conditions observed on the parcel (s) during the routine maintenance of the onsite wastewater treatment and disposal system. G. Tuter life of this system. There are two tanks on this property. One septic tank feeds the EZ-Pak tank. POOL