Loading...
HomeMy WebLinkAbout049-520-018 EH-WWOP-25-000014 ONSITE MAINTENANCE REPORT 1.15.26Site Address: Owner: Mailing: Owners Phone: Evaluator:for Hydrotec TANK #1 (Septic) Tank Volume:Gals.18 Inches X Yes No X Good Fair Poor High X Normal Low Good X Fair Poor X Yes No N/A Scum:12+Inches Sludge:24+Inches X Yes No N/A Scum:0 Inches Sludge:18 Inches X Good Fair Poor N/A X Yes No Yes X No TANK #2 STEP Tank Volume:Gals.At Grade Inches X Yes No X Good Fair Poor High X Normal Low X Good Fair Poor X Yes No N/A Scum:0 Inches Sludge:4 Inches Yes No X Scum:0 Inches Sludge:2 Inches Good Fair Poor X N/A Yes X No Yes X No X Yes No X Yes No X Good Poor X Yes No Alarms: X Audible X Visual EC ETM HLA OVR Yes X No Hydraulic Load Test:X Excellent Good Poor X Dry Ponding N/A Yes X No Yes X No Yes X No Yes X No Yes X No Yes X No Comments and System Map on Back ]HS,I-STEP8/11 Inlet Tee: Outlet Tee: Baffle Condition: Pumping Required: Pump, Vault & Filter Cleaned? Liquid Operating Level: Access Risers: Tank Material:Concrete Condition: Structural Condition: A. Sievers 541-404-8068 Down Slope Seepage: Saturated Field: Multiple Systems: Pump: N/APump:N/A Piezometers: FAILURE Not Applicable Running AMPS:Running Voltage: 1200 Depth to Access Lid: HYDROTEC SOLUTIONS P.O. Box 7908, Chico, CA 95927 (530) 891-4420, FAX: (530) 630-6000 Residential Supplemental Treatment Onsite System Evaluation and Maintenance Report Same # Occupants:N/A 629 Tandy Ct., Chico, CA 95973 S.T.E.P. System Eval. Date: Britt Gastreich 1/15/26 Satisfactory Pressure 10.92/10.89 120.5 Marginal N/A Graywater: Surfacing Effluent: Effluent Line D.Valve: Type of Absorption Field: Bacteria Action: N/A Type of Filter: Control Panel: Tank was Cleaned: Tank was Cleaned: Inlet Tee: Outlet Tee: Baffle Condition: Pumping Required: 1000 Depth to Access Lid: Access Risers:Condition: Liquid Operating Level: Tank Material:Poly Structural Condition: All Floats Operating? Well on Property: SEPTIC TANK: ABSORPTION TRENCHES: Evaluator Signature Date: N l x POOL ^PANEL HOME RT-UNIT O IO <--OUT u TANDY COURT 629 Tandy Ct. HS,I-STEP11/19 PARCEL ADDRESS: We found no problems at this time. COMMENTS / OBSERVATIONS needed to be pumped. It was then pumped 1/20/26. We found no other problems at this time. life of this system. Some exposed aggregate found in septic tank. At the time of inspection, the septic tank ADU SHED 631 TANDY LOCATION OF SEPTIC TANK & ABSORPTION FIELD This onsite wastewater treatment and disposal system evaluation report is a true and complete record of the onsite waste- water treatment and disposal system on the date of the evaluation. No warranty is given or implied regarding the remaining 1/15/26 I certify that this onsite wastewater treatment and disposal system evaluation report reflects conditions observed on the parcel (s) during the routine maintenance of the onsite wastewater treatment and disposal system. A. Sievers