Loading...
HomeMy WebLinkAbout078-010-060 maintenance report 2.16.26 105 Serene Lane 2026AP# Site Address: Owner: Mailing: Owners Phone: Evaluator:for Hydrotec Gals.18 Inches X Yes No Good Fair X Poor X High Normal Low X Good Fair Poor N/A X Good Fair Poor X Yes No N/A Scum:4 Inches Sludge:18 Inches X Yes No N/A Scum:0 Inches Sludge:8 Inches X Good Poor Yes X No Yes X No X Yes No X Yes No N/A Feet Yes X No X Yes No Alarms: X Audible X Visual EC ETM HLA OVR Dry Ponding X N/A Yes X No Yes X No Yes X No Yes X No ] HYDROTEC SOLUTIONS P.O. Box 7908, Chico, CA 95927 (530) 891-4420, FAX: (530) 891-4426 Advantex Laterals Flushed: Pump, Vault & Filter Cleaned: Lateral Squirt Height: Control Panel: Recirc Pump: Recirc Pump:Running AMPS:10.25 Running Voltage:119.5 N/A N/A N/A ADVANTEX POD SYSTEM Eval. Date: Graywater On-site: Dry well Comments and System Map on Back Type of Absorption Field: Piezometers: Surfacing Effluent: Well on Property:Multiple Systems: Type of Filter:Bio-tube Tank was Cleaned: N/A All Floats Operating: Access Risers: Recirc Tank Volume: Date Tank (s) Previously Pumped: Residential Supplemental Treatment Onsite System Evaluation and Maintenance Report Concrete 1500 Structural Condition: Baffle Condition: Tank Material: Liquid Operating Level: Outlet Tee: Inlet Tee: Pumping Required: Bacteria Action: Condition: 107 Serene Lane, Oroville, CA 95965 Depth to Access Lid: Christine Lantz 105 Serene Lane, Oroville, CA 95965 (530) 282-2432 A. Sievers 2/16/26 Sanitech No. SEPTIC TANK: ABSORPTION TRENCHES: Evaluator Signature Date: k N m m <-- Dry wells <-- Concrete lid RT --><-- Pump Panel O O i GARAGE h x GARAGE 10' i NEW HOUSE SERENE LANE PARCEL ADDRESS:107 Serene Lane PRIMARY HOUSE m This onsite wastewater treatment and disposal system evaluation report is a true and complete record of the onsite waste- water treatment and disposal system on the date of the evaluation. No warranty is given or implied regarding the remaining LOCATION OF SEPTIC TANK & ABSORPTION FIELD I certify that this onsite wastewater treatment and disposal system evaluation report reflects conditions observed on the parcel (s) during the routine maintenance of the onsite wastewater treatment and disposal system. A. Sievers 2/16/26 COMMENTS / OBSERVATIONS Found slow leaching due to recent rain and high water table. life of this system. Found water intrusion on both sides of tank, so much was incoming that the system is high leveled. High level float is potentially failed but couldn’t access J-Box due to depth in ground and in a puddle. The Liquid Operating Level is up 6".