HomeMy WebLinkAbout B11-0563 CALFIRE PRE-INSP (2)Butte County Fire Department Fire Prevention Bureau 176 Nelson Avenue,Oroville CA 95965 (530)538-7888 Office,(530)538-2105 Fax SRA &LRA Building Permit #,BI J -D5(cB Address /Location:-D2C.)j=y-eKffi0 lJf 6l1,OtJ1JJ~ Under authority of Public Resources Code (PRC)Section j290 and 4291,Butte County Improvement Standards (BCrS), California Building Code (CBC),and the California Fire Code (CFC),and Chapter 38A Butte County Code,the following items are required by CAL FIRE/Butte County Fire Department for all development located within the State and Local Responsipility Areas of Butte County and are required as p~rt of this permit These requirements are minimums and may be superseded by Butte County local regulations exceeding th6se standards, ~iS relinspection is for:Iosifence -~~~t~~~~::~:~estructure o Ancillary Building (detached garage,shop,shed,etc.) Public Rfsources Code 4290 ADMINISTRA TION 127,,/o~1 aintenance of Defensible Space Measures_7__·"iT<0 ensure continued maintenance of properties in conformance with these standards and measures and to assure continue availability,access,and utilization of the defensible space provided for these standards during a wildfire, provisionf for annual maintenance shall be included in the development plans and/or shall be provided as a condition of the permit,prcel or map approval. ---~RlVE'YAY STANDARDS 1273.10 Driveways __(a)All new driveway construction or an extension of an existing driveway shall comply with Public Resources Code 4290 roa,wa~requirements,Driveways can only serve a single parcel. Length 01Dnveway __(b)f'll driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance of 15 feet along its entire length. 1273.02 rlriveWay Surface __Thd surface shall provide unobstructed access to conventional drive vehicles,including sedans and fire engines. Surfaces s ould be established in conformance with local ordinances,and be capable of supporting a 40,000 pound load.4" of class 2 aggregate base shall be required for all driveways,turnouts and turnarounds. 1273.03 Driveway Grades __The~ade for all driveways shall not exceed 15%without being paved.Grades over 15%shall have 4"of class 2 aggregate rase and 2"of asphalt concrete.No driveways allowed in excess of20%. 1273.0411riveway Radius __(a)~o roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional surface width of 4 feet shall tie added to curves of 50-1 00 feet radius;2 feet to those from 100-200 feet. __(b)The length of vertical curves in roadways,exclusive of gutters,ditches,and drainage structures designed to hold or divert water,shall be not less than 100 feet. 1 Legend:N/A=Not Applicable,X=Required Revised on 05/04/1] Trakit Copy 1273.05 priveway Turnarounds __(dJ A turnaround shall be provided to all building sites on driveways over 300 feet in length,and shall be within 50 feet of the building. __Turnarounds are required on driveways and dead-end roads as specified in this article.The minimum turning radius for a turnaror~d shall be 40 feet from the center line of the road.If a hammerhead-Tis used,the top of the "T"shall be a minimu1 of60 feet in length. 1273.06 ~riveway Turnouts __Cc~IDriveways exceeding 150 feet in length,but less than 800 feet in length,shall provide a turnout near the midpoint of the drirWay.Where the driveway exceeds 800 feet,turnouts shall be provided no more than 400 feet apart. __TTouts shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end. ~2 3.7 Driveway Structures (a)~ll driveway,road,street,and private lane roadway structures (Bridges,culverts,and other appurtenant structures hich su~plement the roadway bed or shoulders)shall be constructed to carry at least the maximum load and provide the minimu~1 vertical clearance as required by Vehicle Code Sections 35550,35750 and 35250.All bridges shall be certified by a regiftered Civil Engineer. ~)~ppropriate signing,including but not limited to weight or vertical clearance limitations,one-way road or single lane condrtions,shall reflect the capability of each bridge. M(c)k bridge with only one traffic lane may be authorized by the local jurisdiction;however,it shall provide for unobstruc1ted visibility from one end to the other and turnouts at both ends. GATE TANDARDSI12731~ate Entrance (a)f.1 ate entrances shall be at least two feet wider on both ends then the width ofthe traffic Jane(s)serving that gate. /inimum 14 foot opening. ~21¥\ll gates providing access from a road to a driveway shall be located at least 30 feet from the roadway and shall op/,~~JIOWa vehicle to stop without obstructing traffic on that road. __(c)Whlere a one-way road with a single traffic lane provides access to a gated entrance;a 40 foot turning radius shall be used. SIGNIN<f AND BUILDING NUMBERING 1274.00.Intent To facilit~te locating an emergency and to avoid delays in response,all newly constructed or approved roads,street,and buildings shall be designated by names or numbers,posted on signs clearly visible and legible from the roadway.This section shall not rbstrict the size of letters of numbers appearing on street signs for other purposes. AD~~SING . 127 .8.~ddresses for Buildings __All buildings shall be issued an address by the local jurisdiction which conforms to that jurisdiction's overall address system.Afcessory buildings will not be required to have a separate address;however,each dwelling unit within a building shall be slparatelY identified. 127109.~ize of Letters,Numbers and Symbols for Addresses 1,u~ize of letters,numbers and symbols for addresses shall be a minimum 4 inch letter height,3/8 inch stroke, reflectorz1d,contrasting with the background color of the sign. 127 10.~nstallation,Location and Visibility of Addresses _I_'~(~a:)tll buildings shall have a permanently posted address,which shall.be placed at each driveway entrance and visible from both Idirections of travel along the road.In all cases,the address shall be posted at the beginning of construction and shall be maintained thereafter,and the address shall be visible and legible from the road on which the address is located. 2 Legend:N/A=Not Applicable,X=Required Revised on 05104111 Trakit Copy ADDRESrNG (cont.) ~)Address signs along one-way roads shall be visible from both the intended direction of travel and the opposite d~lS!i0n.I1lI-(c)Vfhere multiple addresses are required at a single driveway,they shall be mounted on a single post. Atd)~ere a roadway provides access solely to a single commercial or industrial business,the address sign shall be placed at the nearest road intersection providing access to that site. :2~~~~~'::ICA TlONSTANDARDS To reduceJhe intensity ofa wildfire by reducing the volume and density of flammable vegetation,the strategic location of fuel mOdilcation and greenbelts shall provide: (1)Increased safety for emergency fire equipment and evacuating civilians; (2)A POin~of attack or defense from a wildfire. 1276.01 S~tback for Structure Defensible Space SRA only L /!....(} []~All parcels 1 acre and larger shall provide a minimum 30 foot setback for buildings and accessory buildings from al property lines and/or the center of the road. 1276.isposal of Flammable Vegetation and Fuels Disposal,including chipping,burning or removal to a landfill site approved by the local jurisdiction,of flammable vegetation land fuels caused by site development and construction,road and driveway construction,and fuel modification shall be completed prior to completion of road construction or final inspection of a building permit. DEFENSILLE SPACE GUIDELINES pUbljyRerources Code 4291 _~_AA]:P9rson that owns,leases,controls,operates,or maintains a building or structure in,upon,or adjoining any mountainous area,forest-covered lands,brush-covered lands,grass-covered lands,or any land that is covered with flammable material,stall at all times do all of the following: ~¥aintain around and adjacent to the building or structure additional fire protection or firebreak made by removing ~~~~ammable vegetation,or combustible growth that is located within 100 feet from the building or structure or to the property libe or at a greater distance if required by state law,or local ordinance,rule,or regulation.Grass and other vegetation~located more than 30 feet from the building or structure and less than 18 inches in height above the ground may be maintaine where necessary to stabilize the soil and prevent erosion.This subdivision does not apply to single specimens of trees or ot ier vegetation that is well-pruned and maintained so as to effectively manage fuels and not form a means of rapidly transmitting fire from other nearby vegetation to a dwelling or structure.Lr.c)iemove that portion of any tree that extends within 10 feet of the outlet of a chimney or stovepipe. ----.L(d)Maintain any tree adjacent to or overhanging a building free of dead or dying wood. /(e)raintain the roof of a structure free of leaves,needles,or other dead vegetative growth.-...4>Prior to constructing a new building or structure or rebuilding a building or structure damaged by a fire in such an area,the construction or rebuilding of which requires a building permit,the owner shall obtain a certification from the local building official that the dwelling or structure,as proposed to be built,complies with all applicable state and local building standards,jincluding those described in subdivision (b)of Section 51189 of the Government Code,and shall provide a copy of the certification,upon request,to the insurer providing course of construction insurance coverage for the building or structure.Upon completion of the construction or rebuilding,the owner shall obtain from the local building official,a copy of the fmal i~spection report that demonstrates that the dwelling or structure was constructed in compliance with all applicable state and local building standards,including those described in subdivision (b)of Section 51189 of the Government Code, and shall provide a copy of the report,upon request,to the property insurance carrier that insures the dwelling or structure. 3 Legend:N/A=Not Applicable,X=Required Revised on 05/04/11 TrakitCopy Public Resources Code 4621 thru 4628 and California Forest Practice Rules Article 7 SRA only ~io~to any lot clearing activity or cutting of trees,contact the Butte area Forester at (530)872-6353 to determine the need for a jess then 3 acre conversion exemption permit or a timber harvest plan.If required,a copy of the Timber Harvest Plan or less than 3 acre conversion exemption permit will need to be reviewed at the final inspection. o~ennil required IZf Permi not required ~:~~::Irnia Fire Code ~~'L~G Tank Clearance of Combustibles Weeds,grass,brush,trash and other combustible materials shall be kept a minimum of 10 feet from LP-gas tanks or containers'l 380 .4 Protecting LPG containers from vehicles -n...L.....Iw'<-Where exposed to vehicular damage due to proximity to alleys,driveways or parking areas,LP-gas containers, egulators and piping shall be protected in accordance with Section 312. .,~~tment Fees _~_;Fiir~:e department fees are collected by the Butte County Development Services Department at the time of application for your builciing permit.You are assessed two fees (pre-inspection and fmal inspection).Additional fees will be assessed when the fife de~artment inspector is required to perform additional re-inspections of your property,those additional fees must be paid to Development Services,7 County Center Drive in Oroville. caIiforniJ Building Code Chapter 7A, Materialsland Construction Methods for Exterior Wildfire Exposure Check with Butte County Department of Development Services -Building Division for specific questions regarding Chapter 7+of the California Building Code and its application to your project.Also,check the websites below for useful info ation including the full text of Chapter 7A CBC. Al of the Fire Safe Requirements are posted on the Butte County Fire Department website at http://www.buttefire.org To find acceptable Chapter 7A products:Click on NEW PRODUCTS HANDBOOK http://www.fire.ca.gov/fire_prevention/fire_prevention _wildland.php Check the status of your permit online at http://dspermits.buttecounty.net/etrakit/Permit_Search.asp Need afire department inspection?Call our inspection line. (530)538-6226 v()car9Can 1l('J' Inspector Date 0'::1/-2_JD -CIS Assessorslparcel Number 4 Legend:N/A=Not Applicable,X=Required Revised on 05104/11 Trakit Copy Traket Notes ~to final project at time of pre-inspection. Remove final inspection fee. Add this note in Traket. Needs another final re-inspection. Needs another final re-inspection fee. Pre-inspection form needs last page to be completed;APN # Pre-inspection form needs last page to be completed;owner info Pre-inspection form needs last page to be completed. California Department of Forestry and Fire Protection Butte County Fire Department Fire Prevention Bureau 176 Nelson Avenue,Oroville,CA 95965 (530)538-7888 Office,(530)538-2105 Fax Final Inspection Sheet Property Owners ~"m"V tlJ r~'rf!uu Property Location:17-2,<;"1t.A eJ/!1A)IL...L CiIY'C2~ Inspector:"j)c~~spection Date:9 ---I >'"-'I Pennit#,EIJ -0 Cb 3 APN#030 -~':f-z>-O':::;-S Correct I Notes ftt¥tt't~fNf t f:1Ulbtt)WA¥'tfi~IVtWA\%St'ANbAtlfiS."""""'"""""",~,,~'ff""';;;"",...'ff':f:fl·:::":",,,:::)"j,J:.""""",,'{,'{"",'(::rrrr::::nrr:n:tt"rr:;:;,;:\"":~"",,.:r::r:'1rrtttr'mtttrm:t~::: (1273.020 Roadwav 0 Drivewav Surfaces ,It t.J 1213.030 Roadway 0 Driveway Grades K\lJ 1273.040 Roadway 0 Driveway Radius .....l)'1213.06 0 Roadwav 0 Driveway Turnouts l'1273.050 Roadway 0 Driveway Turnarounds "/ / .\'1273.070 Roadway 0 Driveway Structures~n 12V3.08 One-Wav Roads l\t'\.'I'12V3.09 Dead-End Roads I~\1273.11 0 Roadway 0 Driveway Gate Entrance 12174.07.Installation of Road,Street and Private Lane Signs 12174.0I.Size of Letters,Numbers and Symbols for Street and Roads Signs 1294.03.Height of Street and Road Signs 1274.0S.Intersecting Roads,Streets and Private Lanes 12U4.06.Signs Identifying Traffic Access limitations /"./.....r--12~4.08.Addresses for Buildings /'12~4.09.Size of Letters,Numbers and Symbols for Addresses/\/J F\1\1 I 1 1/12174.10.Installation,Location and Visibility of Addresses Y~"/lA'A'ili I./)I(JYL.~A~VIP Aktr 12176.0I Setback for Structure Defensible Space /11'Y Same Practical Effect Requirements for buildings less then 30 feet from nronertv line \/704A.1.3 Roofvallevs \/7Q4A.I.S Roof gutters \/7Q4A2.2 Eave or cornice vents\I 704A.2.3 Eave protection \/7Q4A.3.1.1 Exterior wall coverings \7q4A.3.2 Exterior wall openings I 704A.3.2.1 Exterior wall vents /7Q4A.3.2.2 Exterior glazing and window wallsI\7Q4A.3.2.3 Exterior door assembliesI\704A.4.I.I Deckina surfacesI\7Q4A.4.2.I Underside of appendages and floor proiections.I \7Q4A.4.2.2 Unenclosed under floor protection J \chapter 15 Rooflna and Roof Structures I ,1503.1,IS03.2,IS03.3 Roof Coverings within Slate Responsibility Area .,.""""",//'r:::::{{)))\,%'(ilMJU,totlMWJtttltR;UUt!t),:::t},{""""",":"""",'".'.'.'.'.'.'.'.'."""""','",',"""""""""""""""""""",,,,""""'""".. ...•••••••••.•.~3807.3,LPG Tank Clearance of Combustibles '-71..A~~/V//r;'~..--:7 ......•.•..•.3807.4 Protecting LPG containers from vehicles /' .--I RE-INSPECTION DATES INSPECTOR RE-INSPECTION DATES INSPECTOR The above 0 1'idenlial ~ei~:~;;':7;~I;'~has been buill 10 meet all applicable state and 10001 fire safe standards including those stand ds desc 11bedin Government Code Section 51189(b). Inspector Signj'"re ISTATEOFCALl50RNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION NOTICE OF 9EFENSIBLE SPACE INSPECTION LE-100 (REV,AWil 2009) NOTICE OF DEFENSIBLE SPACE INSPECTION THIS IS A LEGAL NOTICE OF FIRE HAZARD VIOLATIONS (IF NOTED IN BLOCK 32) SHADED BOXES MANDATORY -ALL OTHERS OPTIONAL 4J"O.LU 2,INSPECTOR'S TITLE 3,BADGE NUMBER 4,IN~rECTOR'S A,GENCYFf/S .3 f(JLPL~(M ':;;5, 7"UNIT 10 8,BATTALION NUMBER 9,STATION NUMBER 29. SRA LRA 11,APPAGE 12,AP PARCEL # FRA BIA BLM CAL FIRE ,Contract County USFS Other oooooo o 0 ~0 A D·~O 0 ~~~~~--~~~~7=~~~~~~~~==~--~~~~13.LATITUDE (Datum =WGS84)14,LONGITUDE (Datum =WGS84)o 0 (DecimalDegrees;ex:38,5761)(DecimalDegrees;ex:121.4969)o 0 10,AP BOOK 15. wwI-Uwo, (/)z 23.E-MAIL ADDRESS21.PHOtE NUMBER #1 24,COMMENTS:i[31/-0:;;-63 19,STATE CA 20,ZIP IF YOU HAVE CPUESTIONS CONCERNING THIS INSPECTION NOTICE,CALL THIS PHONE NUMBER: 25,!26,IN~TION #27.CITATION#28.FOLLOW-UP INSPECTION DATE: VIOUATION REINS~N?-er 0 0 0 0 0I0YES..ErNO 1 2 3 1 2 3 (MMIDDIYYYY)A P id d "II 'h f hl d For ways to prevent ember intrusion into-yourrovieanmaintainatatimesascreenoverteoutlet0everycimneyorstovepipethatisattachetoa fireplace,store,or other device that burns any solid or liquid fuel.The screen shall be constructed of building during a wildfire,see nonflammabt material with openings of not more than one-half inch in size.CFC 603,8;CBC 2802,1 o violatiJns observed. (check ifrpPIiCable) 30.0 Alternative practices approved having same practical effect. See comments section above (14 CCR 1299 (c) (check if applicable) 31. ACTIONS TAKENoLeftinformationmaterial Discussed clearance with resident j2(i:.eft copy of this inspection noticetJCitationissuedoRecommendcitationtorevention 33.GENERAL BUILDING CONSTRUCTION TYPE o Wood SidingoWoodRoof ~mbustible siding D-Marrufactured (Mobile)HomeoMetaloConcrete/BlockoOther Deck Present 0 YES ~- http://www.flre.ca.govlfire..preventionldown/oadsl ~'Violations wJre observed.Additional clearance is needed for the following areas: IFORADIDITIONAL INFORMATION ON HOW TO COMPLY WITH DEFENSIBLE SPACE CLEARANCE REQUIREMENTS,PLEASE VISIT: I WWW.FIRE.CA.GOV General Grdelines for Creating Defensible Space are found at htlp://www.fire.ca.gov/CDFBOFDB/pdfs/Copyof4291finalguidelines9 29 06,pdf o 30 foot zone PRC 4291(a)(1);14CCR 1299(a)(1)0 Grass 0 Brush 0 Trees 0 Shrubs o Reduced Fu IZone (30'-100')PRC 4291(a)(1);PRC 14CCR1299 (a)(2)0 Grass 0 Brush 0 TreesoShrubsoRemoveSPlifiChazardousfuelidentifiedbyinspector-14CCR 1299(b) o Dead and dy'ing woody surface fuels -14CCR1299(d) o Remove pJion of a tree that extends within 10 'of the outlet of a chimney or stovepipe PRC 4291 (a)(4) o Maintain .,plant adjacent to or overhanging a building free of dead or dying wood -PRC 4291 (a)(5) oo Maintain the roof of a structure free of leaves,needles,other vegetative matter -PRC 4291 (a)(6) 34,