HomeMy WebLinkAbout04-2609 CALFIRE FIANL INSPECTION (2)California Department of Forestry and Fire Protection Butte County Fire Department Fire Prevention Bureau 176 Nelson Avenue,Oroville,CA 95965 (530)538-7888 Office,(530)538-2105 Fax Final Inspection Sheet Property Owners Name:fllA...tiMf)/,)w lid Property Location:11'5 PB eAta.l.t,:1_f0,-City:~~ Inspector:6......•.•."""If<rd.u'W'~Inspection Date:to}Q.O Permit#()4:-&lc>09 APN#O 6 R,5 <..0 -()~ (\~ Correct Notes "rtfJ:":::':J:::':Nrrr:rRuAfiWAMlfifdVJt\VANdjTANoARl}s:::rttrr :",,:,::,...:':':':"'...(J1'\:t,r':::":"::'..'::;:;:,r,""r l:;::tr}'::"';"""""';:?'t';';"""""""."";"""":"':"':'w.,.,:r'.'.,.';:':;":;';:L;"··'"ntttttt ••tt't"tttn:tt to\.1273.020 Roadway 0 Driveway Surfaces 1/VV\1273.030 Roadway 0 Driveway Grades \Ii ~r \1273.040 Roadway 0 Driveway Radius /~..~1273.050 Roadway 0 Driveway Turnarounds -.~~1273.060 Roadway 0 Driveway Turnouts\'Y 1273.07 0 Roadway 0 Driveway Structures.~K 1273.08 One-Way Roads )'\'V "1273.09 Dead-End RoadsK..)1273.11 0 Roadway 0 Gate Entrance 1274.0 I.Size of Letters,Numbers and Symbols for Street and Roads Signs"/'1274.05.Intersecting Roads,Streets and Private Lanes 1274.03.Height of Street and Road Signs 1274.06.Signs Identifving Traffic Access limitations~<,Witt.::'···;I ~1274.08.Addresses for Buildings~,/A 1274.09.Size of Letters,Numbers and Symbols for Addresse'¥1ll /I/J 1.---n n I <J r I ~SibilitYOfAddresses~~~ ~iblespace +-A a.-o.,1JLhd l~fililfilil~l(J.....r-.Same Practical Effect Requirements for buildings less then 30 feet from pror/£#.y fine 'H::.D·'tit 1\1.~~-- ../1276.02 Disposal of Flammable Vegetation and Fuels !/.....l':;O:O:':;:lnr:;(:'.~PB.M£]~£Sb.UR'ditS.¢06.~r46:n.$;tUU}ml~~':AN6.¢ALtFOttNl;g:ll'nttFSTPID\dtt'CftktlCt$.;r:.;.r:.t:.tttrJrt.tr ••••n ;::.;",;,;,ii/.;.;.;.;.;W\;.•.•.".:},,:;:;;';')fffif ~If required,request to see a copy of the conversion permit or Timber Harvest Plan \J,704A.I.2 Roof coverings"\I 704A.1.3 Roofvalleys 1274.07.Installation of Road,Street and Private Lane Signs \I 704A.I.5 Roof gutters \I 704A2.2 Eave or cornice ventsI704A.2.3 Eave protection\I 704A.3.1.1 Exterior wall coverings 704A.3.2 Exterior wall openings I 704A.3.2.2 Exterior glazing and window walls 704A.3.2,I Exterior wall vents I \704A.3.2.3 Exterior door assemblies I \704A.4,1.1 Decking surfaces 704A.4.2.2 Unenclosed under floor protection I \704A.4.2.1 Underside of appendages and floor nroiections. Area I \ :t~:t~;/~:~\w.•,·.:.. I \ I Chapter 15 Roofing and Roof Structures 1503.1,1503.2,1503.3 Roof Coverings within State VI, ./J 1 ...).--3807.3,LPG Tank Clearance of Combustibles ,...A I .I"rlf ./3807.4 Protecting LPG containers from vehicles r.FA p~£ J ..•.•4 INSPECTORRE-INSPECTlON DATES INS&qCTOR RE-INSPECTION DATES -Inspection passed on:\.!1~I-,0 The above ~idential 0 ancillary structure has been built to meet all applicable state and local fire safe standards including those ~ov'mm'nt C~"tion 51 I89(b). Inspector Signature 452090 STATE OF CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION NOTICE OF DEFENSIBLE SPACE INSPECTION LE-100 (REV.April 2009) NOTICE OF DEFENSIBLE SPACE INSPECTION THIS IS A LEGAL NOTICE OF FIRE HAZARD VIOLATIONS (IF NOTED IN BLOCK 32) SHADED BOXES MANDA TORY -ALL OTHERS OPTIONAL 2.INSPECTOR'S TlTLE 3.BADGE NUMBER 4.INSPECTOR'S AGENCYf""f'sr:-582:>CAL-Frfl..C (MU; FRA 7.UNIT 10..8.BATTALION NUMBER 9.STATION NUMBER-Pyfru.d I 621 BLM CAL FIRE Contract County USFS - Other o 0s-ro0o0o0 oooooo 11.AP PAGE 12.AP PARCEL #10.AP BOOKo <? 13.LATITUDE (Datum =WGS84) (Decimal Degrees;ex:38.5761) 14.LONGITUDE (Datum =WGS84) (Decimal Degrees;ex:121.4969) 15.o and write complete address in comments section. UJUJf-oUJn, CI)z 19.STATE CA 17.ADDRESS 18.CITY 21.PHONE NU 23.E-MAIL ADDRESS 24.COMMENTS:(j c.;_c;2 {P Oq I I .1,f'k~~~f!(J'(Jt::~ c P~~~O¥L-:;tk~.6·~.~- 5,f1ace-~~~/V1.A/1/'C.N(~~..v7 IF YOU HAVE QUESTIONS CONCERNING THIS INSPECTION NOTICE,CALL THIS PHON UMBER: VIOLATION REINS~TION?DYES ~NO 31. 25.26.INSPECTION #27.CITATION #28.FOLLOW-UP INSPECTION DATE: ~DODD123 1 2 3 (MMlDDIYYYY) 29.~iolations observed. (check if applicable) 30.D Alternative practices approved having sarne practical effect.ACTIONS TAKEN See comments section above (14 CCR 1299 (c)(check if applicable)D Left information material I--;:-;::---'---'------...------'-...:....J----...-------~-------------_l gniscussed clearance with resident%'32.~copy of this inspection noticeViolationswereobserved.Additional clearance is needed for the following areas:o Citation issued D Recommend citation to revention 33.GENERAL BUILDING CONSTRUCTION TYPE D 30 foot zone,PRC 4291 (a)(1);14CCR 1299(a)(1)0 Grass 0 Brush 0 Trees D Shrubs D Reduced Fuel ZOne(30'-1 00')PRC 4291 (a)(1);PRC 14CCR1299 (a)(2)D Grass DoShrlJbs.. .d""Remove specific hazardous fuel identified by inspector -14CCR 1299(b) p-wood SidingoWoodRoofoNon-combustible sidingoManufactured(Mobile)HomeoMetal D Concrete/Block D Other Deck Present 0 YES ~. o Dead and dying woody surface fuels -14CCR1299(d) o D Do Remove portion of a tree that extends within 10 'of the outlet of a chimney or stovepipe PRC 4291 (a)(4) Maintain any plant adjacent to or overhanging a building free of dead or dying wood -PRC 4291(a)(5) Maintain the root of a structure free of leaves,needles,.other vegetative matter -PRC 4291 (a)(6) Provide and maintain at all times a screen over the outlet of every chimney or stovepipe that is attached to a fireplace,stove,or other device that burns any solid or liquid fuel.The screen shall be constructed of nonflammable material with openings of not more than one-half inch in size.CFC 603.8;CBC 2802.1 For ways to prevent ember intrusion into your building during a wildfire,see http://www.fire.ca_90vlfire..prevention/downloads/ 34. FOR ADDITIONAL INFORMATION ON HOW TO COMPLY WITH DEFENSIBLE SPACE CLEARANCE REQUIREMENTS,PLEASE VISIT: WWW.FIRE.CA.GOV General Guidelines for Creating Defensible Space are found at http://www.fire.ca.gov/CDFBOFDB/pdfs/Copyof4291finalguidelines9 29 06.pdf California Department of Forestry and Fire Protection Butte County Fire Department 176 Nelson Avenue,Oroville,CA 95965 (530)538-7888 Office,(530)538-2105 Fax Fire Safe Requirements Correction Notice ~~~~~~~~~~~~~~~I~n~s~e~c~ti~o~n~D~a~t~e:~/~~~L-~~-rPenni~APN#ROAD Y /DRIVEWAY STANDARDS (b)Address signs a ong one-way roads shall be visible from both the intended direction of 1273.01.Road Width travel and the 0 osite direction. All roads shall be constructed to provide a minimum of two nine-foot traffic lanes providing (c)Where multiple addresses are required at a single driveway,they shall be mounted on a two-way traffic flow,unless other standards are provided in this article,or additional sin Ie ost. requirements are mandated by localjurisdictions or local subdivision requirements.(d)Where a roadway provides access solely to a single commercial or Roadwa s can serve more than one arcel,industrial business,the address sign shall be placed at the nearest road intersection providing 1273.10Driveways accessto thatsite. (a)All new driveway construction or an extension of an existing driveway shall comply with 1276.01 Setback for Structure Defensible SpacePublicResourcesCode4290roadwayrequirements.Driveways can only serve a single [1(a)All parcels I acre and larger shall provide a minimum 30 foot setback for buildings areel.and accesso buildin s from all ro ert lines and/or the center of the road. (b)All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical [1(b)For parcels less than I acre,tbe localjurisdiction shall provide for the same practical clearance of 15 feet alon its entire len tho effect. (c)Driveways exceeding 150feet inlength,but less than 800 feet in length,shall provide a Same Practical Effect Requirements for buildings less then 30 feet from property line: turnout near the midpoint of the driveway.Where the driveway exceeds 800 feet,turnouts [1If the Building Setback is less then 30 feet from all property Jines and/or the center of the shall be rovided no more than 400 feet a art.road,the following shall be required: (d)A turnaround shaJl be provided to all building sites on driveways over 300 feet in length,Class A roof and sbaJl be within 50 feet of the buildin Fully enclosed eaves on entire structure 1273.02 0 Roadway 0 Driveway Surfaces Fire rated metal doors on side toward property line with insufficient setback The surface shall provide unobstructed access to conventional drive vehicles,including Siding on entire structure from the following list: sedans and fireengines.Surfaces should be established in conformance with local ordinances.(a)Stucco-3 coatandbecapableofsupportinga40,000 pound load.4"of class 2 aggregate base shall be (b)Non combustible Board,Plank or similar siding re uired for all drivewa s,turnouts and turnarounds.(c)Masonry 1273.03 0 Roadway 0 Driveway Grades (d)Metal The grade for all driveways shall not exceed 15%without being paved.Grades over I5%~Other Butte Count Fire a roved materials shall have 4"of class 2 aggregate base and 2"of asphalt concrete.No driveways allowed in 1276.02 Disposal of Flammable Vegetation and Fuelsexcessof20%.Disposal,including chipping,burning or removal to a landfill site approved by the local 1273.04 0 Roadway 0 Driveway Radius jurisdiction,of flammable vegetation and fuels caused by site development and construction, (a)No roadway shall have a horizontal inside radius of curvature of less than 50 feet and road and driveway construction,and fuel modification shall be completed prior tocompletion additional surface width of 4 feet shaJl be added to curves of 50-I00 feet radius;2 feet to of road construction or final ins ection of a buildin ermit. those from 100-200 feet.Public Resources Code 4621 thru 4628 and California Forest Practice Rules (b)The length of vertical curves in roadways,exclusive of gutters,ditches,and drainage Prior to any lot clearing activity orcutting of trees,contact the Butte area Forester at (530) structures desi ed to hold or divert water,shall be not less than 100 feet.872-6353 to determine the need for a less then 3 acre conversion exemption permit or a 1273.050 Roadway 0 Driveway Turnarounds timber harvest Ian. Turnarounds arerequired on driveways and dead-end roads as specified inthis article.The California Building Code Chapter 7A, minimum turning radius for a turnaround shall be 40 feet from the centerline ofthe road.If a Materials &Construction Methods for Exterior Wildfire Exposure hammerhead-T isused,the to of the ''Y''shall be aminimum of60 feet in len tho 704A.I Roofing 1273.060 Roadway 0 Driveway Turnouts 704A.1.I General.Roofs shall comply with the requirements of Chapter 7A and Chapter 15. Turnouts shall be a minimum of 10 feet wide and 30 feet long with aminimum 25 foot taper Roofs shall have a roofing assembly installed in accordance with its listing and theoneacbend.manufacturer's installation instructions. 1273.07 0 Roadway 0 Driveway Structures 704A.1.2 Roof coverings.Where the roof profile allows a space between the roof covering (a)All driveway,road,street,and private lane roadway structures (Bridges,culverts,and and roof decking,the spaces shall be constructed to prevent the intrusion of flames and other appurtenant structures which supplement the roadway bed or shoulders)shall be embers,be firestopped with approved materials or have one layer of No.72 ASTM cap sheet constructed to carry at least the maximum load and provide the minimum vertical clearance as installed <'Ver the combustible deckin required by Vehicle Code Sections 35550,35750 and 35250.All bridges shall be certified 704A.1.3 Roof valleys.When provided,valley flashings shall be not less tban 0.019-inch b 'a r istered Civil En ineer.(0.48mm)(No.26 galvanized sheet gage)corrosion-resistant metal installed over a minimum (b)Appropriate signing,including but not limited to weight or vertical clearance limitations.36-inch-wide (914 mm)underlayment consisting of one layer of No.72 ASTM cap sheet one-wa road or sin Ielane conditions,shall reflect the ca abili of each brid ze.runnin r the full len th of the valle (c)A bridge with only one traffic lane may be authorized by the local jurisdiction;however,it 704A.I.S Roof gutters.Roof gutters shall be provided with the means to prevent the shall rovide for unobstructed visibilit from one end to the other and turnouts at both ends.accumulation of leaves and debris in the utter. 1273.08.One-Way Roads 704.A.2 Attic Ventilation. All one-way roads shall be constructed to provide a minimum of one 10-foot traffic lane.The 704.A.2.1 General.When required by Chapter 15,roof and attic vents shall resist the local jurisdiction may approve one-way roads.All one-way roads shall connect to a two lane intrusion of flame and embers into the attic area of the structure,or shall be protected by roadway atboth ends,and shall provide access to an area currently zoned for no more than 10 corrosion-resistant,noncombustible wire mesh with V,-inch(6 mm)openings or its dwelling units.In no case shall it exceed 2640 feet in length.A turnout shall be placed and e uivalent.constructed at a roximatel the mid oint of each ona-wa road.704A2.2 Eave or cornice vents.Vents shall not be installed in eaves and cornices. 1273.09.Dead-End Roads Exception:Eave and cornice vents may be used provided they resist the intrusion of flame (a)The maximum length of a dead-end road,including all dead-end roads accessed from the f-'_+-can~d burning embers into the attic area of the structure.dead-end road,shall not exceed the following cumulative lengths,regardless of the numbers 704A.2.3 Eave protection.Eaves and soffits shall meet the requirements ofSFM 12-7A-3 orofparcelsserved:shall be protected by ignition-resistant materials or noncombustible construction on the parcels zoned for less than one acre 800 feet ex osed underside. parcels zoned for I to 4.99 acres 1,320 feet 704A.3 Exterior Walls.parcels zoned for 5 to 19.99 acres 2,640 feet 704A.3.1 General.Exterior walls shall be approved noncombustible or ignition-resistant parcels zoned for 20 acres or larger 5,280 feet material,heavy timber,or log wall construction or shall provide protection from the intrusion All lengths shall be measured from the edge of the roadway surface at the intersection that of flames and embers in accordance with standard SFM 12-7A-I. begins the road to the end of the road surface at the intersection that begins the road to the end 704A.3.1.1 Exterior wali-coverings.Exterior wall coverings shall extend from the top of the ofthe road surface at its farthest point.Where a dead-end road crosses areas of differing foundation to the roof,and terminate at2-inch (50.8 mm)nominal solid wood blocking zoned arcel sizes,re uirin different len th limits,the shortest allowable len th shall a >.11:.between rafters at all roof overhangs,or in the case of enclosed eaves,terminate at the (b)Where parcels are zoned 5 acres or larger,turnarounds shall be provided ata maximum of enclosure.1320foot intervals.704A.3.2 Exterior wall openings.Exterior wall openings shall be inaccordance with this c)Each dead-end road shall have a turnaround constructed at its terminus.section.1273.11 0 Roadway 0 Driveway Gate Entrance 704A.3.2.1Exterior wall vents.Unless otherwise prohibited by other provisions of this code, (a)Gate entrances shall be at least two feet wider on both ends then the width of the traffic vent openings in exterior walls shall resist the intrusion of flame and embers into the structure lane(s)servin that rate.or vents shall be screened with acorrosion-resistant,noncombustible wire mesh with ~-inch (b)All gates providing access from a road to a driveway shall be located at least 30 feet from 6mm 0 enin s or its e uivalent.the roadwa and shall 0 en to allow a vehicle to s10 without obstructing traffic on that road.704A.3.2.2 Exterior glazing and window walls.Exterior windows,window walls,glazed (c)Where a one-way road with a single traffic lane provides access to a gated entrance;a 40 doors,and glazed openings within exterior doors shall be insulating-glass units with a foot tumin radius shall be used.minimum of one tempered pane,or glass block units,or have a fire-resistance rating of not STREET &ROAD SIGNS less than 20 minutes,when tested according toASTM E 2010,or conform tothe performance 1274.01.Size of Letters.Numbers and Symbols for Street and Roads Signs re uirements of SFM 12-7A-2. Size of letters,numbers,and symbols for street and road signs shall be a minimum 3 inch 704A.3.2.3 Exterior door assemblies.Exterior door assemblies shall conform to the letter bei ht,3/8 inch stroke,reflectorized,contrastin with the back round color of the si II.performance requirements of standard SFM 12-7A-lor shall be of approved noncombustible 1274.02.Visibility and Legibility of Street and Road Signs construction,or solid core wood having stiles and rails not less than I 3/8 inches thick with Street and road signs shall be visible and legible from both directions ofvehicle travel for a interior field panel thickness no less than I lj.inches thick,or shall have a fire-resistance distance of at least 100 feet.Height of street and road signs shall be uniform county wide,and rating of not less than 20 minutes when tested according to ASTM E 2074. meet the visibili and Ie ibilit standards of this article.Exception:Noncombustible or exterior fire-retardant treated wood vehicle access doors are 1274.03.Height of Street and Road Signs not re uired to coml'.",IY,-w=ith"-"th,,i,,-s",ch",a~p",te,..r,-.--------------------1 Height of street and road signs shall be Uniform County wide,and meet the visibility and 704A.4.1 Decking. legibility standards of this article.All street signs inMailed will be in accordance with 704A.4.J.I Decking surfaces.Decking,surfaces,stair treads,risers,and landings of decks, standards S-Il and S-13 BCIS 13.03-6 .porches,and balconies where any portion or such surface iswithin 10 feet (3048 mm)of the 1274.05.Intersecting Roads,Streets and Private Lanes primary structure shall comply with one of the following methods: Signs required by this article identifying intersecting roads,streets and private lanes shall be I)Shall be constructed of ignition-resistant materials and pass the performance requirements laced at the intersection of those roads,streets,and/or rivate lanes.ofSFM 12-7A-4,Parts Aand B. 1274.06.Signs Identifying Traffic Access limitations 2}Shall be constructed with heavy timber,exterior fire-retardant-treated wood or approved A sign identifying traffic access or flow limitations,including but not limited to weight or noncombustible materials.vertical clearance limitations,dead-end road,one-way road or single lane conditions,shall be 3)Shall pass the performance requirements orSFM I2·7A-4.Part A,12-7A-4.7.5.1 only withlaced:3 net peak heat release rate of2SkW/sq-ft for a 40 minute observation period and: a at the intersection recedin the traffic access limitation,and a)Decking surface material shall pass the accelerated weathering test and be identified as b no more than 100 feet before such traffic access limitation.exterior type,in accordance with ASTM E84 and;the exterior wall covering to which itthe 1274.07.Installation of Road,Street and Private Lane Signs deck is attached and within 10 (3048mm)feet ofthe deck shall be constructed of approved Road,street and private lane signs required by this article shall be installed prior to final noncombustible or ignition resistant material.acce tance b the local iurisdiction ofroad im rovements.£x;~vpH-on'W",I1~A"~not r~"9~.i•.od to co.•..•..•!"I)'.•.•...,!I,fl.,.,"'••b.,.,."..,•.••••.i(th.,.A•...•.•t,.'"8 <:••...r"•.•."" 1274.08.Addresses for Buildings material conforms to ASTM E-84 Class B name spread. All buildings shall be issued an address by the local jurisdiction which confonns to that The use of paints,coatings,stains,or other surface treatments are not an approved method of jurisdiction's overall address system.Accessory buildings will not be required to have a rotection as re uired in this cha ler. se arate address·however each dwellin unit within a buildin 'shall be se aratel identified.704A.4.2.1 Underside of appendages and floor projections.The underside of cantilevered 1274.09.Size of Letters,Numbers and Symbols for Addresses and overhanging appendages and floor projections shall maintain the ignition-resistant Size of letters,numbers and symbols for addresses shall be a minimum 3 inch letter height,integrity of exterior walls,or the projection shall be enclosed to the rade. 3/8 inch stroke renectorized contrastin with the background color ortlle sig",no..'-l 704A.4.2.2 Unenclosed under floor protection.Buildings shall have all under floor areas 1274.10.Installation,Location and Visibility otAddresses enclosed to the grade with exterior walls in accordance with Section 704A.3 (a)All buildings shall have a permanently posted address.which shall be placed at each Exception:The complete enclosure of under noor areas may be emitted where (he underside driveway entrance and visible from both directions oftravcl along the road.Inall cases,the of all exposed floors,exposed structural columns,beams and supporting walls are protected address shall be posted at the beginning of construction and shall be maintained thereafter,as re uired with exterior i nition-resistant material construclion or be heav timber. and the addre s IIbe visible and le~ad on which he address is located. ~Revilred 1211512007 ~11 .JU-t II II ~A _rr-;