Loading...
HomeMy WebLinkAboutB07-2026 CALFIRE FINAL, LE 100STATE OF CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION NOTICE OF DEFENSIBLE SPACE INSPECTION LE-100 (NEW -5/2006) NOTICE OF DEFENSIBLE SPACE INSPECTION THIS IS A LEGAL NOTICE OF FIRE HAZARD VIOLATIONS (IF NOTED IN BLOCK 32) SHADED BOXES MANDATORY -ALL OTHERS OPTIONAL 2.INSPECTOR'S TITLE 3.BADGE NUMBER 4.INSPECTOR'S AGENCYF~MM!D'::/YY~_ 12.AP PARCEL #I6. PROTECTION RESPONSIBILITY FRA 8.BATTALION NUMBER 9.STATION NUMBER6l.ISRALRA D D ~D DDDDD DDDDDD BIA BLM CAL FIRE Contract County USFS Other 10.AP BOOK 11.AP PAGE 14.LONGITUDE (Datul =WGS84) (Decimal Degrees;ex:121.4969) o and write complete address in comments sectio~. 15. wWI-oWo, (f)Z 18.CITY 19.STATE CA 20.ZIP 21.PHONE NUMBER #1 E-MAIL ADDRESS VIOLATION REINSPECTION? DYES l2rNo 31.I ACTIONS TtKEN D Left information material D Discussed clearanbe with resident ~copy of this infpection notice D Citation issued toRecommendcitatiTn to prevention 33.I GENERAL BUILDING CONSTRUCTION TYPE 30.D Alternative practices approved having same practical effect.See comments section above (14 CCR 1299 (c) (check if applicable) 29.D No violations observed. (check if applicable) Violations were observed.Additional clearance is needed for the"following areas: (check applicable sections) D 30 foot zone,PRC4291(a);14CCR 1299(a)(1) D D D D o oo D Grass D Brush D Trees D Shrubs Reduced Fuel Zone (30'-100')PRC 4291 (b);14CCR1299 (a)(2)D Grass D Brush D Trees D Shrubs o Wood SidingoWoodRoof ~on-combustible sidingoManufactured(Mobile)Home D MetaloConcrete/Block Maintain the roof of a structure free of leaves,needles,other dead vegetation -PRC 4291(e)D Other +-_ Provide and maintain at all times a screen over the outlet of every chimney or stovepipe that is attached to .:>I a fireplace,stove,or other device that burns any solid or liquid fuel.The screen shall be constructed of Deck present¥YEIS 0 NO nonflammable material with openings of not more than one-half inch in size.PRC 4291 (f) Remove specific hazardous fuel identified by inspector -14CCR 1299(b) Dead and dying woody surface fuels -14CCR1299(d) Remove portion of any tree that extends within 10 feet of the outlet of a chimney or stovepipe PRC 4291(c) Maintain any tree adjacent to or overhanging a building free of dead or dying wood -PRC 4291(d) 34. FOR ADDITIONAL INFORMATION ON HOW TO COMPLY WITH DEFENSIBLE SPACE CLEARANCE REQUIREMENTS,PLEisE VISIT: .WWW.FIRE.CA.GOV I Final Inspection Sheet n I PropertyOwners Nam~s:~O-t Property Location:LfIO~br!?oad City:~ Inspcctor\01 OCA1C;..vvif Inspection Date:~-23 ~//Pcrmit#-801 -20 '2.C.R APN#(if!-Lj]d -/1 / Correct I I Notes::::::::i/Yf'i'U::::inIEIT.kdAPWAMXURlvEWi&Mgjj'&VUigQS'mlrEEI'IIIITIIrNltJrrmIIJti=ttt=itt'=!=tttt:=:!itmIfi:rEIai:Irtttttt=====:tt=tltttt=::tlttt;:;:==:WiIiI:::tt=::/===!t=::=::::::::J:=:ttt ./1 1 1273.020 Roadway E1'DrlYeway Surfaces-;;;7"1 1 1273.030 Roadway ~lftiyeway Grades ~J 1 1 1273.04 0 Roadway 12I'00iveway Radius II""'"1 1 1273.05 0 Roadway I7"Driveway Turnarounds California Department of Forestry and Fire Protection Butte County Fire Department Fire Prevention Bureau 176 Nelson Avenue,Oroville,CA 95965 (530)538-7888 Office,(530)538-2105 Fax ~1 71 1273.06 0 Roadway 0 Driveway Turnouts...•••••••17 1 1273.070 Roadway 0 Driveway Structures ~1 1273.08 One-Way Roads7...~1 1273.09 Dead-End Roads -.f;;'T ~lli73.11 0 Roadway t;?5riveway Gate Entrance I';:;::::'·'·,······!/1 1274.0 I.Size of Letters,Numbers and Symbols for Street and Roads Signs,,7 1 1274.03.Height of Street and Road Signs /1 "1 1274.06.Signs Identifying Traffic Access limitations171'I 1274.07.Installation of Road.Street and Private Lane Signs 1)("1 1274.05.Intersecting Roads,Streets and Private Lanes 1274.10.Installation.Location and Visibilit of Addresses 1276.0 I Setback for Structure Defensible Space t/"I J274.09.Size of Letters,NUl1lbcr;~~S;l1lb;I;'ior Add7e;se;,/;A:=;:.~nMJ'~':.,<1IF r-.=VkG n 1 7 /"J7 I Same Practical Effect Requirements for buildings less then 30 feet from property line ~1 1276.02 Disposal of Flammable Vegetation and Fuels ~t~tt~t~)~~~~·i:i:~:~:·~t~~~ i:::i:i;:;:~:~:~:~:i:~:~:~:i:~/:::;:;::~:::=::::::::::.: """"""1 1 704A.I.3 Roofvalleys........-1 1 704A.I.5 Roof gutters ./""T 1 704A2.2 Eave or cornice vents /'""1 1 704A.2.3 Eave protection;'--1 1 704A.3.1.1 Exterior wall coverings ::::::.---r_1 704A.3.2.1 Exterior wall vents ,..,....-1 1 704A.3.2.2 Exterior glazing and window walls ______I 1 704AJ.2.3 Exterior door assemblies ~1 1 704A.4.I.I Decking surfaces .....r I 704A.3.2 Exterior wall openings /'1 1 704A.4.2.1 Underside of appendages and floor projections. ~1 1 704A.4.2.2 Unenclosed under floor protection :;:;:;:;:;:;:;:;;;::;::::::::::1:::;.;.;•.••• __.1 Chapter 15 Roofing and Roof Structures .••..••••••....1 1 1503.1.1503.2,1503.3 R'oof Coverings within State Responsibility Area --;;;;;;;::t 1.____1 3807.3,LPG Tank Clearance of Combustibles /./l -------r 3807.4 Protectine LPG containers from vehicles 1 2"d 1-41"'2."L flf 1"1)_..•,.h .1./,,-I Insncctlon nasscd on: rTheabove~ential 0 ancillary structure has been built to meet all applicable state and local fire safe standards including those standards described in Government Code Section 51189(b).A J //ff)~-----'-jtJ///V~.~~- RE-INSI'ECTION DATES 1 INSPECTOR "[spcctor Signature