HomeMy WebLinkAboutB16-2884 CALFIRE PRE AND FINAL INSPECTIONPermit #616-2884 APN #026-250-063 Butte County Fire Department Fire Prevention Bureau 176 Nelson Avenue,Oroviile CA 95965 (530)538-7888 Office,(530)538-2105 Fax Contact Name:Jeff Stevens Address /Location:301 Sunnybrook Lane,Palermo Under authority of Public Resources Code (PRC)Section 4290 and 4291,Butte County Improvement Standards (BCIS), California BuildingCode (CBC), and the California FireCode (CFC), andChapter 38A ButteCounty Code, the following items are required by CAL FIRE/Butte County Fire Department for all development located within the State and Local Responsibility Areas of Butte County and are required as part of this permit. These requirements are minimums and may be superseded by Butte County local regulations exceeding these standards. ^is pre mspectlon is for: CZl Residence • Addition to existing structure •Manufactured Home • Ancillary Building (detached garage, shop, shed, etc.) Public Resources Code 4290 ADMINISTRATION 1272.00 Maintenance of Defensible Space Measures To ensure continued maintenance of properties in conformance with these standards and measures and to assure continued availability, access, and utilization of the defensible space provided for these standards during a wildfire, provisions for annual maintenance shall be included in the development plans and/or shall be provided as a condition of the permit,parcel or map approval. DRIVEWAY STANDARDS 1273.10 Driveways (a) All new driveway construction or an extension of an existing driveway shall comply with Public Resources Code 4290 roadway requirements.Driveways can only serve a single parcel. Length of Driveway (b) All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance of 15 feet along its entire length. 1273.02 Driveway Surface The surface shall provide unobstructed access to conventional drive vehicles,including sedans and fire engines. Surfaces should be established in conformance with local ordinances,and be capable of supporting a 40,000 pound load. 4" class 2 aggregate base shall be required for all driveways, turnouts and turnarounds. 1273.03 Driveway Grades The grade for all driveways shall not exceed 15%without being paved. Grades over 15%shall have 4"of class 2 aggregate base and 2"of asphalt concrete.No driveways allowed in excess of 20%. 1273.04 Driveway Radius (a) No roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional surface width of 4 feet shall be added to curves of 50-100 feet radius;2 feet to those from 100-200 feet. (b) The length of vertical curves in roadways,exclusive of gutters,ditches,and drainage structures designed to hold or —^.-..^divert water,shall be not less than 100 feet. 1 Legend:N/A=Not Applicable,X-Requircd Revised on 09/09/12 Trakit Copy l^^OS Driveway Turnarounds (d) A turnaround shall be provided to all building sites on driveways over 300 feet in length, and shall be within 50 feet of the building. Turnarounds are required on driveways and dead-end roads as specified in this article.The minimum turning radius for a turnaround shall be 40 feet from the center line of the road. If a hammerhead-T is used, the top of the "T"shall be a minimum of 60 feet in length. 127^.06 Driveway Turnouts :)Driveways exceeding 150 feet in length, but less than 800 feet in length,shall provide a turnout near the midpoint of he driveway.Wherethedrivewayexceeds800feet,turnouts shallbeprovidednomorethan400 feetapart. Turnouts shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end. 12y3.07 Driveway Structures (a) All driveway,road, street, and private lane roadway structures (Bridges,culverts,and other appurtenant structures whlich supplement theroadwaybedor shoulders)shallbe constructed to carryat leastthe maximum loadandprovidethe mi limum vertical clearance as required by Vehicle Code Sections 35550,35750 and 35250.All bridges shall be certified by lai a registered Civil Engineer. _(b)Appropriate signing, including but not limited to weight or vertical clearance limitations, one-way road or single e conditions, shall reflect the capability of each bridge. _(c)A bridge with only one traffic lane may be authorized by the local jurisdiction;however,it shall provide for imobstructed visibility from one end to the other and turnouts at both ends. GATE STANDARDS 1273.J,]Gate Entrance (a) Gate entrances shall be at least two feet wider on both ends then the width of the traffic lane(s)serving that gate. Minimum 14 foot opening. _(b)All gates providing access from a road to a driveway shall be located at least 30 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on that road. (c) Where a one-way road with a single traffic lane provides access to a gated entrance; a 40 foot turning radius shall be used. SIGNING AND BUILDING NUMBERING 1274.00.Intent To facilitate locating an emergency and to avoid delays in response, all newly constructed or approved roads, street, and buildingsshall be designatedby names or numbers,postedon signs clearly visible and legiblefromthe roadway.This section shall not restrict the size of letters of numbers appearing on street signs for other purposes. ADDRESSING 1274^08rAddresses for Buildings All buildings shall be issued an address by the local jurisdiction which conforms to that jurisdiction's overall address system.Accessory buildings will not be required to have a separate address;however,each dwelling unit within a building shall be separately identified. 127<L^.Size of Letters,Numbers and Symbols for Addresses ./Size of letters,numbers and symbols for addresses shall be a minimum 4 inch letter height, 3/8 inch stroke, reflectorized,contrasting with the background color of the sign. 1274,41).Installation,Location and Visibility of Addresses /(a) All buildings shall have a permanently posted address, which shall be placed at each driveway entrance and visible from both directions of travel along the road. In all cases, the address shall be posted at the beginning of construction and shall be maintained thereafter, and the address shall be visible and legible from the road on which the address is located. 2 Legend:N/A=Not Applicable,X=Requlred Revised on 09/09/12 Trakit Copy ADDRESSING (cont.) Address signs along one-way roads shall be visible from both the intended direction of travel and the opposite Where multiple addresses are required at a single driveway, they shall be mounted on a single post. Jhlb) direction. FUEL MODIFICATION STANDARDS 1276.00 Intent To reduce the intensityof a wildfire by reducingthe volumeanddensity of flammablevegetation,the strategic locationof fuel modification and greenbelts shall provide: (1) Increasedsafety for emergency fire equipmentand evacuatingcivilians; (2) A point of attack or defense from a wildfue. 12701 Setback for Structure Defensible Space SRA only (a) Allparcels1acreandlargershallprovidea minimum 30 footsetbackfor buildings andaccessorybuildings from all property lines and/or the center of the road. 1276.02.J)i$posal of Flammable Vegetation and Fuels /Disposal,includingchipping, burningor removalto a landfillsite approved by the localjurisdiction, of flammable vegetation and fuelscaused by site developmentand construction,road anddrivewayconstruction,and fuel modification shallbe completedprior to completion of road constructionor final inspection of a buildingpermit. DEFENSIBLE SPACE GUIDELINES Public Resources Code 4291 /A personthat owns, leases,controls,operates,or maintainsa building or structure in, upon,or adjoiningany mountainousarea, forest-coveredlands,brush-covered lands,grass-covered lands, or any land that is covered withflammable material, shall at all times do all of the following: -^h)Maintain around and adjacent to the building or structure additional fire protection or firebreak made by removing all brush, flammable vegetation, or combustible growth that is located within 100 feet from the building or structure or to the property line or at a greater distance if required by state law, or local ordinance,rule, or regulation.Grass and other vegetation located more than 30 feet from the building or structure and less than 18 inches in height above the ground may be maintained where necessary to stabilize the soil and prevent erosion. This subdivision does not apply to single specimens of trees or other vegetation that is well-pruned and maintained so as to effectively manage fuels and not form a means of rapidly transmitting fire from other nearby vegetation to a dwelling or structure. Remove that portion of any tree that extends within 10 feet of the outlet of a chimney or stovepipe. Maintain any tree adjacent to or overhanging a building free of dead or dying wood. Maintain the roof of a structure free of leaves,needles,or other dead vegetative growth. _(f)Prior to constructing a new building or structure or rebuilding a building or structure damaged by a fire in such an area, the constructionor rebuilding of which requiresa buildingpermit,the owner shallobtain a certificationfromthe local building official that the dwelling or structure,as proposed to be built,complies with all applicable state and local building standards, including those described in subdivision (b)of Section 51189 of the Government Code, and shall provide a copy of the certification,upon request, to the insurer providing course of construction insurance coverage for the building or structure. Uponcompletionof theconstructionor rebuilding,the owner shall obtain from the localbuildingofficial, a copy of the final inspectionreport that demonstratesthat the dwelling or structure was constructed in compliancewith all applicable state and local building standards, including those described in subdivision (b)of Section 51189 of the Government Code, and shall provide a copy ofthe report, upon request, to the property insurance carrier that insures the dwelling or structure. 3 Legend:N/A=Not Applicable,X=Requlred Revised on 09/09/12 Trakit Copy Public Resources Code 4621 thru 4628 and California Forest Practice Rules Article 7 SRA only /y^^rior to any lot clearing activity or cutting of trees,contact the Butte area Forester at (530)872-6353 to determine the need for a less then 3 acre conversion exemption permit or a timber harvest plan. If required,a copy of the Timber Harvest Plan or less than 3 acre conversion exemption permit will need to be reviewed at the final inspection. •F^rmit required Q'Permit not required 2010 California Fire Code LPG Tanks 3807^LPG Tank Clearance ofCombustibles ^eeds,grass, brush, trash and other combustible materials shall be kept a minimum of 10 feet from LP-gas tanks or containers. 3807.4^rotecting LPG containers from vehicles ✓"-"where exposed to vehicular damage due to proximity to alleys, driveways or parking areas, LP-gas containers, regulators and piping shall be protected in accordance with Section 312. Flr^Department Fees X Fire department fees are collected by the Butte County Development Services Department at the time of application for your buildingpermit.Youare assessed two fees (pre-inspectionand final inspection). Additional fees will be assessed when the fire departmentinspector isrequiredto performadditional re-inspectionsof your property, those additional feesmustbe paidto DevelopmentServices,7 CountyCenter Drive in Oroville. California Building Code Chapter 7A, Materials and Construction Methods for Exterior Wildfire Exposure Checkwith ButteCountyDepartmentof DevelopmentServices -Building Division forspecific questions regarding Chapter 7A of the CaliforniaBuildingCode and itsapplicationto your project. Also, check the websites below for useful information including the full text of Chapter 7A CBC. All of the Fire Safe Requirements,including Wildland Urban Interface (WUI)Products from the Office of the Stale Fire Marshal's office are posted on the Butte County Fire Department website at httn;//w\v>v.biittecountv.net/lire Check the status of your permit online at httn;//dsDcrmits»buttecountv.net/etrakit/Permit Search.asn N.Carver Inspector For Final Inspection call our Inspection Line. (530)538-6226 4-13-2017 Date or Contractors Signature Stevens.Jeff &Julie Owners Name Legend:N/A=Not .Applicable.X=Required Revised i)n 09/09/12 Trakil Copy Property Owners ^ame Inspector: California Department of Forestry and Fire Protection Butte County Fire Department Fire Prevention Bureau 176 Nelson Avenue,Oroville,CA 95965 (530)538-7888 Office.(530)538-2105 Fax Final Inspection Sheet -A Location:3^/yj /1 iScHUnrde:^Permit#Jo/S' >i_City: apn# Correct Z EH- 3: 1273.02 • Roadway • DrivewaySurfaces 1273.03 •Roadway •Driveway Grades 1273.04 •Roadway •Driveway Radius 1273.05 •Roadway •Driveway Turnarounds 1273.06 •Roadway • Driveway Turnouts 1273.07 •Roadway • Driveway Structures 1273.08 One-Way Roads 1273.09 Dead-End Roads 1273.11 • Roadway •Driveway Gate Entrance 1274.01.Size of Letters.Numbers and Symbols for Street and Roads Signs 1274.03.Height of Street and Road Signs 1274.05.Intersecting Roads,Streets and Private Lanes 1274.06.Signs Identifying Traffic Access limitations 1274.07.Installation of Road, Street and Private Lane Signs ADDni'SMXG 1274.08.Addresses for Buildings 1274,09.Size of Letters,Numbers and Symbols for Addresses 1276.01 Setback for Structure Defensible Space Same Practical EfTect Requirements for buildings less then 30 feet from property line if rcciuircti,request to see a ccpN oi the niinersiun permit or Timber Harvest Plan i4v '—~^cauformia buijlding code chaptertA» MATEUVMS &CONSTRUCT ION METHODS f QR £Xl'£RIOR.'»TtDy!iii 704A.1.2 Roof coverings 704A.1.3 Roof valleys 704A.1.5 Roof gutters 704A2.2 Eavc or cornice vents 704A.2.3 Eave protection 7Q4A.3.1.I Exterior wall coverings 704A.3.2 Exterior wall openings 704A.3.2.1 Exterior wall vents 704A.3.2.2 Exterior glazing and window walls 704A.3.2.3 Exterior door assemblies 704A.4.1.I Decking surfaces 704A.4.2.1 Underside of appendattes and floor projections. 704A.4.2.2 Unenclosed under floor protection Chapter 15 Roofing and Roof Structures 1503.1.15^.2,1503,3 Roof Coverings within State Responsibili^AreaVlou.?.!.louj.z,13UJ.J Kooicovering: 3807.3,LPG Tank Clearance of Combustibles 3807.4 Protecting LPG containers from vehicles Notes 7^ RE-INSPECTION DATES INSPECTOR RE-INSPECTION DATES INSPECTOR I"3rd Inspection passed on:—hJ.('n v The above-Ej residential •ancillary structure hasbeenbuilttomeetall applicable stateand local fire safe standards includingthose standards described in Government Code Section 51189(b). Inspector Signature