HomeMy WebLinkAboutB17-0470 CALFIRE FINAL INSPECTIONCalifornia Department of Forestry and Fire Protection
Butte County Fire Department
Fire Prevention Bureau
176 Nelson Avenue,Oroville,OA 95965
(530)538-7888 Office.(530)538-2105 Fax
Final Inspection Shee
Property Location:
H 0 "f T""Permit#i ^
Property Owners Name:
n /•>
Inspector:A ,y ^
City:y()J
kvmo 3f)"1^10 "O
Correct
/r .\i-Inspection Dat
ROAD>YaY /ORlAY STANDARDS
1273.02 • Roadway •Driveway Surfaces
1273.03 •Roadway •Driveway Grades
1273.04 •Roadway u Driveway Radius
1273.05 •Roadway •Driveway Turnarounds
1273.06 •Roadway •Driveway Turnouts
1273.07 •Roadway • Driveway Structures
1273.08 One-way Roads
1273,09 Dead-End Roads
11 •Roadway •Driveway Gate Entrance
•mmrnm.
1274.01,Size of Letters,Numbers and Symbols for Street and Roads Signs
1274.03,Height of Street and Road Signs
1274.05.Intersecting Roads. Streets and Private Lanes
1274,06,Signs Identifying Traffic Access limitations
1274.07,Installation of Road,Street and Private Lane Signs
1274.08,Addresses for Buildings
1274.09,Size of Letters,Numbers and Symbols for Addresses
1274.10,Installation. Locationand Visibility of Addresses
1276.01 Setback for Structure Defensible Space
Same Practical Effect Requirements for buildings less then 30 feet from property line
1276.02 Disposal of Fiammable Vegetation and Fuels
If required,request to see a copy of the conversion permit or Timber Harvest Plan
iCALirORNlA BUILDING CODE CnAPTERMl ,
''MATERIALS &.CONSTRUCTION METHODS f OREXTERIORWiLPFmE:
704A-I.2 Roof coverings
704A,I.J Root valleys
704A,I.5 Roof gutters
704A2.2 Eave or cornice vents
7Q4A.2.3 Eave protection
704A.3.I.1 Exterior wall coverings
704A,3.2 Exterior wall openings
704A,3,2,1 Exterior wall vents
704A.3.2,2 Exterior glazing and window walls
704A,3.2.3 Exterior door assemblies
704A.4.I,I Decking surfaces
704A.4,2.I Underside of appendages and floor projections.
704A.4,2.2 Unenclosed under floor protection
Chapter 15 Roofing and Roof Structures
1503,1.1503,2.1503,3 RoofCoverings within State Responsibili
CAUFORNLA FIRE CODE ^
-3^07,3,LPGTankClearanceof Combustibles
3807,4 Protecting LPG containers from vehicles
Area
Notes
OA J'V
RE-INSPECTION DATES INSPECTOR RE-INSPECTION DATES INSPECTOR
1"3rd
2""Inspection passed on:V t>-1 ^//.C.€f /)/)A CA
Inspector Signature
The above • residential Q ancillary structurehas beenbuilt to meet all applicablestate and local fire safe standards includingthose
standards described in Government Code Section 51189(b).