HomeMy WebLinkAboutB17-0825 CALFIRE PRE AND FINAL INSPECTIONButte County Fire Department Fire Prevention Bureau 176 Nelson Avenue, Oroville CA 95965 For General Questions(530) 538-7888 Office For Inspection Call (530) 538-6226 SRA & LRA Building Permit: Address / Location: Under authority of Public Resources Cod California Building Code (CBC), and the items are required by CAL FIRE/Butte County Fire Department for all development located within the State and Local Responsibility Areas of Butte County and are required as part of this permit. These requirements are minimums and may be superseded by Butte County local regulations exceeding these standards. This pre inspection is for: ❑ residence O� Addition to existing structure ❑ Manufactured Home ❑ Ancillary Building (detached garage, shop, shed, etc.) Public Resources Code 4290 ADMINISTRATION 1272. aintenance of Defensible Space Measures To ensure continued maintenance of properties in conformance with these standards and measures and to assure continued availability, access, and utilization of the defensible space provided for these standards during a wildfire, provisions for annual maintenance shall be included in the development plans and/or shall be provided as a condition of the permit, parcel or map approval. DRIVEWAY STANDARDS 1273.10 Driveways (a) All new driveway construction or an extension of an existing driveway shall comply with Public Resources Code 4290 roadway requirements. Driveways can only serve a single parcel. Length of Driveway _(b) All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance of 15 feet along its entire length. 1273.02 Driveway Surface —The surface shall provide unobstructed access to conventional drive vehicles, including sedans and fire engines. Sb faces should be established in conformance with local ordinances, and be capable of supporting a 40,000 pound load. 4" of class 2 aggregate base shall be required for all driveways, turnouts and turnarounds. _ 1273.03 Driveway Grades The grade for all driveways shall not exceed 15% without being paved. Grades over 15% shall have 4" of class 2 aggregate base and 2" of asphalt concrete. No driveways allowed in excess of 20%. �J 1273.04 Driveway Radius q`l _(a) No roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional surface width of 4 feet shall be added to curves of 50-100 feet radius; 2 feet to those from 100-200 feet. (b) The length of vertical curves in roadways, exclusive of gutters, ditches, and drainage structures designed to hold or ivert water, shall be not less than 100 feet. Legend: N/A=Not Applicable, X=Required Revised on 09/09/12 Trakit Copy 3.05 Driveway Turnarounds �(d) A turnaround shall be provided to all building sites on driveways over 300 feet in length, and shall be within 50 of the building. _Turnarounds are required on driveways and dead-end roads as specified in this article. The minimum turning radius for naround shall be 40 feet from the center line of the road. If a hammerhead -T is used, the top of the "T" shall be a imum of 60 feet in length. 127 5.06 Driveway Turnouts (c) Driveways exceeding 150 feet in length, but less than 800 feet in length, shall provide a turnout near the midpoint of C ie driveway. Where the driveway exceeds 800 feet, turnouts shall be provided no more than 400 feet apart. Turnouts shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end. 127 5.07 Driveway Structures (a) All driveway, road, street, and private lane roadway structures (Bridges, culverts, and other appurtenant structures Twhh supplement the roadway bed or shoulders) shall be constructed to carry at least the maximum load and provide the um vertical clearance as required by Vehicle Code Sections 35550,35750 and 35250. All bridges shall be certified egistered Civil Engineer. (b) Appropriate signing, including but not limited to weight or vertical clearance limitations, one-way road or single onditions, shall reflect the capability of each bridge. (c) A bridge with only one traffic lane may be authorized by the local jurisdiction; however, it shall provide for unobstructed visibility from one end to the other and turnouts at both ends. GATESTANDARDS 1273,H Gate Entrance (a) Gate entrances shall be at least two feet wider on both ends then the width of the traffic lane(s) serving that gate. Minimum 14 foot opening. (b) All gates providing access from a road to a driveway shall be located at least 30 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on that road. _&(c) Where a one-way road with a single traffic lane provides access to a gated entrance; a 40 foot turning radius shall be used. SIGNING AND BUILDING NUMBERING 1274.00. Intent To facilitate locating an emergency and to avoid delays in response, all newly constructed or approved roads, street, and buildings shall be designated by names or numbers, posted on signs clearly visible and legible from the roadway. This section shall not restrict the size of letters of numbers appearing on street signs for other purposes. ADDRESSING 1274. ft Addresses for Buildings All buildings shall be issued an address by the local jurisdiction which conforms to that jurisdiction's overall address system. Accessory buildings will not be required to have a separate address; however, each dwelling unit within a building shall be separately identified. 1274.0. Size of Letters, Numbers and Symbols for Addresses Size of letters, numbers and symbols for addresses shall be a minimum 4 inch letter height, 3/8 inch stroke, 1274.W. Installation, Location and Visibility of Addresses (a) All buildings shall have a permanently posted address, which shall be placed at each driveway entrance and visible from both directions of travel along the road. In all cases, the address shall be posted at the beginning of construction and shall be maintained thereafter, and the address shall be visible and legible from the road on which the address is located. Legend: N/A=Not Applicable, X=Required Revised on 09/09/12 Trakit Copy ADDRESSING (cont.) _44+-(b) Address signs along one-way roads shall be visible from both the intended direction of travel and the opposite dir do (c) Where multiple addresses are required at a single driveway, they shall be mounted on a single post. FUEL MODIFICATION STANDARDS 1276.00 Intent To reduce the intensity of a wildfire by reducing the volume and density of flammable vegetation, the strategic location of fuel modification and greenbelts shall provide: (1) Increased safety for emergency fire equipment and evacuating civilians; (2) A point of attack or defense from a wildfire. 1276..01 Setback for Structure Defensible Space SRA onlyG� �d [ ] ! KT (a) All parcels 1 acre and larger shall provide a minimum 30 foot setback for buildings and accessory buildings from all property lines and/or the center of the road. 1276..12 -Disposal of Flammable Vegetation and Fuels Z Disposal, including chipping, burning or removal to a landfill site approved by the local jurisdiction, of flammable vegetation and fuels caused by site development and construction, road and driveway construction, and fuel modification shall be completed prior to completion of road construction or final inspection of a building permit. DEFENSI LE SPACE GUIDELINES Public esources Code 4291 A person that owns, leases, controls, operates, or maintains a building or structure in, upon, or adjoining any mountainous area, forest -covered lands, brush -covered lands, grass -covered lands, or any land that is covered with flammable material, shall at all times do all of the following: �(b) Maintain around and adjacent to the building or structure additional fire protection or firebreak made by removing all brush, flammable vegetation, or combustible growth that is located within 100 feet from the building or structure or to the property line or at a greater distance if required by state law, or local ordinance, rule, or regulation. Grass and other vegetation located more than 30 feet from the building or structure and less than 18 inches in height above the ground may be maintained where necessary to stabilize the soil and prevent erosion. This subdivision does not apply to single specimens of trees or other vegetation that is well -pruned and maintained so as to effectively manage fuels and not form a means of rapidly transmitting fire from other nearby vegetation to a dwelling or structure. Remove that portion of any tree that extends within 10 feet of the outlet of a chimney or stovepipe. _(� Maintain any tree adjacent to or overhanging a building free of dead or dying wood. / (e) intain the roof of a structure free of leaves, needles, or other dead vegetative growth. Prior to constructing a new building or structure or rebuilding a building or structure damaged by a fire in such an a, the construction or rebuilding of which requires a building permit, the owner shall obtain a certification from the local building official that the dwelling or structure, as proposed to be built, complies with all applicable state and local building standards, including those described in subdivision (b) of Section 51189 of the Government Code, and shall provide a copy of the certification, upon request, to the insurer providing course of construction insurance coverage for the building or structure. Upon completion of the construction or rebuilding, the owner shall obtain from the local building official, a copy of the final inspection report that demonstrates that the dwelling or structure was constructed in compliance with all applicable state and local building standards, including those described in subdivision (b) of Section 51189 of the Government Code, and shall provide a copy of the report, upon request, to the property insurance carrier that insures the dwelling or structure. Legend: N/A=Not Applicable, X=Required Revised on 09/09/12 Trakit Copy Public Resources Code 4621 thru 4628 and California Forest Practice Rules Article 7 SRA only Prior to any lot clearing activity or cutting of trees, contact the Butte area Forester at (530) 872-6353 to determine the 74 need for a less then 3 acre conversion exemption permit or a timber harvest plan. If required, a copy of the Timber Harvest Plan or less than 3 acre conversion exemption permit will need to be reviewed at the final inspection. ❑ ermit required Permit not required 2010 California Fire Code LPG Tanks 3807,3, LPG Tank Clearance of Combustibles / Weeds, grass, brush, trash and other combustible materials shall be kept a minimum of 10 feet from LP -gas tanks or containers. 3807.4 Protecting LPG containers from vehicles _Where exposed to vehicular damage due to proximity to alleys, driveways or parking areas, LP -gas containers, regulators and piping shall be protected in accordance with Section 312. Fire D artment Fees Fire department fees are collected by the Butte County Development Services Department at the time of application for your building permit. You are assessed two fees (pre -inspection and final inspection). Additional fees will be assessed when the fire department inspector is required to perform additional re -inspections of your property, those additional fees must be paid to Development Services, 7 County Center Drive in Oroville. California Building Code Chapter 7A, Materials and Construction Methods for Exterior Wildfire Exposure Check with Butte County Department of Development Services —Building Division for specific questions regarding Chapter 7A of the California Building Code and its application to your project. Also, check the websites below for useful information including the full text of Chapter 7A CBC. All of the Fire Safe Requirements, including Wildland Urban Interface (WUI) Products from the Office of the State Fire Marshal's office are posted on the Butte County Fire Department website at http://www.buttecouiity.nettfire Check the status of your permit online at http://dspermits.buttecounty.net/etraidt/Permit—Search.asp N. Carver Inspector `1(12 9 -120(1-L0-q' Assessors Parcel Number For Final Inspection call our Inspection Line. (530) 538-6226 15,q -1 =f' Date Property Owner or Contractors Signature Legend: N/A=Not Applicable, X=Required Revised on 09/09/12 Traldt Copy :alifornia Department of Forestry and Fire Protection Butte County Fire Department Fire Prevention Bureau 176 Nelson Avenue, Oroville, CA 95965 (530) 538-7888 Office, (530) 538-2105 Fax Final Inspection Sheet r Property Owners Name: C � roperty Location: /7,5i4�ity: C Inspector: �/t CQ Y LAy spection i79t� -- Permit#.[/ -7 -09 ?,S APN# --©O Correct I Notes •:. .•. y A WKM.'.. '.iYS�Y �.v ' Y.T. ..0,1nERa ,n f:. :.E.i 1273.02 0 Roadway 0 Driveway Surfaces ''t aR.e £, .....vR'x,E'. ..MWE 1273.03 0 Roadway 0 Driveway Grades 1273.04 0 Roadway 0 Driveway Radius 1273.05 0 Roadway 0 Driveway Turnarounds 1273.06 0 Roadway 0 Driveway Turnouts 1273.07 0 Roadway 0 Driveway Structures 1273.08 One -Way Roads 1273.09 Dead -End Roads 1273.11 0 Roadwa 0 Drivewa Gate Entrance lf 1274.01. Size of Letters, Numbers and Symbols for Street and Roads Signs 1274.03. Height of Street and Road Signs 1274.05. Intersecting Roads, Streets and Private Lanes 1274.06. Signs Identifying Traffic Access limitations 1274.07. Installation of Road, Street and Private Lane Si ns .. : ,e n.i f.:.' .. .na✓d' �n. :. )`i.2; \ . ,�. ... v 9 .:$' '9 1274.08, Addresses for Buildings . . 1274.09. Size of Letters, Numbers and Symbols for Addresses 1274.10. Installation, Location and Visibility of Addresses .2°i. R N a.YR"$ •5•••"�6�'Q•• t 1276.01 Setback for Structure Defensible Space y> .«D. �S'C.0 9y i', I .� . . Same Practical Effect Requirements for buildings less then 30 feet from property line 1276.02 Dis osal of Flammable Ve etation and Fuels GRS�GOYY 3 s :: If required, re gest to see a cog of the conversion errnit or Timber Harvest Plan 704A. 1.2 Roof coverings 704A. 1.3 Roof valleys 704A.1.5 Roof gutters 704A2.2 Eave or cornice vents 704A.2.3 Eave protection 704A.3. I.1 Exterior wall coverings 704A.3.2 Exterior wall openings I it 704A.3.2.1 Exterior wall vents 704A.3.2.2 Exterior glazing and window walls 704A.3.2.3 Exterior door assemblies 704A.4.1.1 Decking surfaces 704A.4.2.1 Underside of appendages and floor projections. 704A.4.2.2 Unenclosed under floor protection 15 Roaring and Roof Structures -Chapter 1503.1, 1503.2, 1503.3 Roof Coverins within State Res onsibilit Area 7>t�;m:.' t't� Q:�''�r :B: 3807.3, LPG Tank Clearance of Combustibles SS3N3v.,::Rsu'r•P 3807.4 Protecting LPG containers from vehicles RE -INSPECTION DATES INSPECTOR RE -INSPECTION DATES INSPECTOR 1st 3r 2" 1 1 Inspection passed on - / 1 c .t2i The above 0 residential 21-ncilste has been built to meet all applicable state and local fire safe standards including those M escribed in Government Code Section 51189(b). 'Inspector Signature