HomeMy WebLinkAboutB17-0924 CAL FIRE PRE AND FINAL INSPECTIONr—
Butte County Fire Department
Fire Prevention Bureau
176 Nelson Avenue, Oroville CA 95965
(530) 538-7888 Office, (530) 538-2105 Fax
Permit # B17-0924
APN # 063-030-006
Applicant Name: HASTAIN, JARED
Permit Address: 4729 HARTLEY DR, FOREST RANCH, CA 95942
Phone: 353-0274 P, Q I S`/
Cell:
Under authority of Public Resources Code (PRC) Section 4290 and 4291, Butte County Improvement Standards (BCIS),
California Building Code (CBC), and the California Fire Code (CFC), and Chapter 38A Butte County Code, the following
items are required by CAL FIRE/Butte County Fire Department for all development located within the State and Local
Responsibility Areas of Butte County and are required as part of this permit. These requirements are minimums and may be
superseded by Butte County local regulations exceeding these standards.
T is pre inspection is for:
❑ Residence
Addition to existing structure
Public Resources Code 4290
❑ Manufactured Home
❑ Ancillary Building (detached garage, shop, shed, etc.)
AINISTRATION
127 .00 Maintenance of Defensible Space Measures
To ensure continued maintenance of properties in conformance with these standards and measures and to assure
continued availability, access, and utilization of the defensible space provided for these standards during a wildfire,
provisions for annual maintenance shall be included in the development plans and/or shall be provided as a condition of the
permit, parcel or map approval.
DRIVEWAY STANDARDS
73 10 Driveways
(a) All new driveway construction or an extension of an existing driveway shall comply with Public Resources Code
4 0
roadway requirements. Driveways can only serve a single parcel.
of Driveway
All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance of 15 feet along its
1213. 02
2 3.02 Driveway Surface
The surface shall provide unobstructed access to conventional drive vehicles, including sedans and fire engines.
oSur ces should be established in conformance with local ordinances, and be capable of supporting a 40,000 pound load. 4"
of rc ss 2 aggregate base shall be required for all driveways, turnouts and turnarounds.
Driveway Grades
me grade for all driveways shall not exceed 15% without being paved. Grades over 15% shall have 4" of class 2
e base and 2" of asphalt concrete. No driveways allowed in excess of 20%.
14 Driveway Radius
(a) No roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional surface width of 4
all be added to curves of 50-100 feet radius; 2 feet to those from 100-200 feet.
(b) The length of vertical curves in roadways, exclusive of gutters, ditches, and drainage structures designed to hold or
water, shall be not less than 100 feet.
Legend: N/A=Not Applicable, X=Required
Revised on 04/10/17
Traldt Copy
73.05 Driveway Turnarounds
(d) A turnaround shall be provided to all building sites on driveways over 300 feet in length, and shall be within 50
feet of the building.
kk�_Tumarounds are required on driveways and dead-end roads as specified in this article. The minimum turning radius for
a turnaround shall be 40 feet from the center line of the road. If a hammerhead -T is used, the top of the "T" shall be a
minimum of 60 feet in length.
)6 Driveway Turnouts
(c) Driveways exceeding 150 feet in length, but less than 800 feet in length, shall provide a turnout near the midpoint
driveway. Where the driveway exceeds 800 feet, turnouts shall be provided no more than 400 feet apart.
shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end.
.07 Driveway Structures
_(a) All driveway, road, street, and private lane roadway structures (Bridges, culverts, and other appurtenant structures
h supplement the roadway bed or shoulders) shall be constructed to carry at least the maximum load and provide the
num vertical clearance as required by Vehicle Code Sections 35550, 35750 and 35250. All bridges shall be certified
registered Civil Engineer.
_ J_(b) Appropriate signing, including but not limited to weight or vertical clearance limitations, one-way road or single
lape conditions, shall reflect the capability of each bridge.
-AVA bridge with only one traffic lane may be authorized by the local jurisdiction; however, it shall provide for
unobstructed visibility from one end to the other and turnouts at both ends.
GA�TAN DARDS
127 . 1 Gate Entrance
(a) Gate entrances shall be at least two feet wider on both ends then the width of the traffic lane(s) serving that gate.
Minimum 14 foot opening.
_(b) All gates providing access from a road to a driveway shall be located at least 30 feet from the roadway and shall
open to allow a vehicle to stop without obstructing traffic on that road.
(c) Where a one road with a single traffic lane provides access to a gated entrance; a 40 foot taming radius shall
be used.
SIGNING AND BUILDING NUMBERING
1274.00. Intent
To facilitate locating an emergency and to avoid delays in response, all newly constructed or approved roads, street, and
buildings shall be designated by names or numbers, posted on signs clearly visible and legible from the roadway. This section
shall not restrict the size of letters of numbers appearing on street signs for other purposes.
ADDRESSING
127$.Olf Addresses for Buildings
All buildings shall be issued an address by the local jurisdiction which conforms to that jurisdiction's overall address
system. Accessory buildings will not be required to have a separate address; however, each dwelling unit within a building
shall be separately identified.
1274.Q9: Size of Letters, Numbers and Symbols for Addresses
Size of letters, numbers and symbols for addresses shall be a minimum 4 inch letter height, 3/8 inch stroke,
reflectorzed, contrasting with the background color of the sign.
1274 ,4. Installation, Location and Visibility of Addresses
(a) All buildings shall have a permanently posted address, which shall be placed at each driveway entrance and visible
from both directions of travel along the road. In all cases, the address shall be posted at the beginning of construction and
shall be maintained thereafter, and the address shall be visible and legible from the road on which the address is located.
2
Legend: N/A=Not Applicable, X=Required
Revised on 04/10/17
Trakit Copy
ADDRESSING (cont.)
/]A�::(b) Address signs along one-way roads shall be visible from both the intended direction of travel and the opposite
direction.
,q4:::�(c) Where multiple addresses are required at a single driveway, they shall be mounted on a single post.
FUEL MODIFICATION STANDARDS
1276.00 Intent
To reduce the intensity of a wildfire by reducing the volume and density of flammable vegetation, the strategic location of
fuel modification and greenbelts shall provide:
(1) Increased safety for emergency fire equipment and evacuating civilians;
(2) A point of attack or defense from a wildfire.
1276.01 Setback for Structure Defensible Space SRA only,-- / attt'
[
]A4- (a) All parcels 1 acre and larger shall provide a minimum 30 foot setback for buildings and accessory buildings from
all property lines and/or the center of the road.
127 .02 Disposal of Flammable Vegetation and Fuels
Disposal, including chipping, burning or removal to a landfill site approved by the local jurisdiction, of flammable
vegetation and fuels caused by site development and construction, road and driveway construction, and fuel modification
shall be completed prior to completion of road construction or final inspection of a building permit.
DEFENSIBLE SPACE GUIDELINES
Pu0c Resources Code 4291
A person that owns, leases, controls, operates, or maintains a building or structure in, upon, or adjoining any
mountainous area, forest -covered lands, brush -covered lands, grass -covered lands, or any land that is covered with flammable
material, shall at all times do all of the following:
/(b) Maintain around and adjacent to the building or structure additional fire protection or firebreak made by removing
all brush, flammable vegetation, or combustible growth that is located within 100 feet from the building or structure or to the
property line or at a greater distance if required by state law, or local ordinance, rule, or regulation. Grass and other
vegetation located more than 30 feet from the building or structure and less than 18 inches in height above the ground may be
maintained where necessary to stabilize the soil and prevent erosion. This subdivision does not apply to single specimens of
trees or other vegetation that is well -pruned and maintained so as to effectively manage fuels and not form a means of rapidly
transmt ng fire from other nearby vegetation to a dwelling or structure.
(c) Remove that portion of any tree that extends within 10 feet of the outlet of a chimney or stovepipe.
Maintain any tree adjacent to or overhanging a building free of dead or dying wood.
(e) Maintain the roof of a structure free of leaves, needles, or other dead vegetative growth
Prior to constructing a new building or structure or rebuilding a building or structure
area, the construction or rebuilding of which requires a building permit, the owner shall obtain
building official that the dwelling or structure, as proposed to be built, complies with all appli
standards, including those described in subdivision (b) of Section 51189 of the Government C
of the certification, upon request, to the insurer providing course of construction insurance co
structure. Upon completion of the construction or rebuilding, the owner shall obtain from the
the final inspection report that demonstrates that the dwelling or structure was constructed in
state and local building standards, including those described in subdivision (b) of Section 511
and shall provide a copy of the report, upon request, to the property insurance carrier that ins
3
Legend: N/A=Not Applicable, X=Required
Revised on 04/10/17
Trakit Copy
damaged by a fire in such an
a certification from the local
cable state and local building
ode, and shall provide a copy
verage for the building or
local building official, a copy of
compliance with all applicable
89 of the Government Code,
ur
es the dwelling or structure.
Puplic Resources Code 4621 thru 4628 and California Forest Practice Rules Article 7 SRA only
or to any lot clearing activity or cutting of trees, contact the Butte area Forester at (530) 872-6353 to determine the
need for a less then 3 acre conversion exemption permit or a timber harvest plan. If required, a copy of the Timber Harvest
Plan or less than 3 acre conversion exemption permit will need to be reviewed at the final inspection.
ermit required
permit not required
2016 California Fire Code
LPG Tanks
61LPG Tank Clearance of Combustibles
Weeds, grass, brush, trash and other combustible materials shall be kept a minimum of 10 feet from LP -gas tanks or
co tamers.
6107,4,Protecting LPG containers from vehicles
Where exposed to vehicular damage due to proximity to alleys, driveways or parking areas, LP -gas containers,
regulators and piping shall be protected in accordance with Section 312.
Fire epartment Fees
Fire department fees are collected by the Butte County Development Services Department at the time of application for
y ur building permit. You are assessed two fees (pre -inspection and final inspection). Additional fees will be assessed when
the fire department inspector is required to perform additional re -inspections of your property, those
additional fees must be paid to Development Services, 7 County Center Drive in Oroville.
California Building Code Chapter 7A,
Materials and Construction Methods for Exterior Wildfire Exposure
Check with Butte County Department of Development Services —Building Division for specific questions regarding
Chapter 7A of the California Building Code and its application to your project. Also, check the websites below for
useful information including the full text of Chapter 7A CBC.
All of the Fire Safe Requirements, including
Wildland Urban Interface (WUI) Products from the Office of the State Fire Marshal's office
are posted on the Butte County Fire Department website at
httu://www.buttecounty.net/fire
Check the status of your permit online at
http://dspermits.buttecounty.net/etrakit/Permit—Search.asp
Need afire department inspection? Call our inspection line.
(530) 538-6226
N.CARVER 5-21St2017 a,,L &=-)
Inspector Date Property Owner or Contractors Signature
Legend: N/A=Not Applicable, X=Required
Revised on 04/10/17
Traldt Copy
:alifornia Department of Forestry and Fire Protection
Butte County Fire Department
Fire Prevention Bureau
176 Nelson Avenue, Oroville, CA 95965
(530)538-7888 Office, (530) 538-2105 Fax
Final Inspection Sheet
Property Owne pme: roperty Location: n r
Inspector: 7 /� Inspe on Dat . � y / -Permit# ,s-f�J/� r� APN# �.� T�f��
Correct
Notes
273.02 O Roadway 0 Driveway Surfaces
INSPECTOR
1273.03 0 Roadway 0 Driveway Grades
1273.04 O Roadway 0 Driveway Radius
3r
1273.05 O Roadway 0 Driveway Turnarounds
2"
1273.06 O Roadway 0 Driveway Turnouts
1273.07 0 Roadway 0 Driveway Structures
✓✓Q
1273.08 One -Way Roads
1273.09 Dead -End Roads
1273.11 ❑ Roadwa ❑ Dria Gate Entrance
..
1274.01. Size of Letters, Numbers and S Sym for Streel and Roads Signs
__—
1274.03. Height of Street and Road Siens
1274.05. Intersecting Roads, Streets and Private Lanes
1274.06. Sims Identifying Traffic Access limitations
1274.07. Installation of Road. Street and Private Lene Si'n,
1274.08. Addresses for Buildings( _ _ - s-
1274.09. Size of Lepers, Numbers and Symbols for Addresses
e' "
-
1274.10. Installation, Location and Visibilil of Addresses
1276.01 Setback for Suuctum Defensible Space
tl.
Same Practical Effect Requirements for buildings less then 30 feet from property line
1276.02 Dis osal of Flammable Ve Fetation and Fuels
If rc aired, re gest to see a(co jryyor�ff the conversion ernut or Timber Harvest Plan
1, 113
MIN i:
704A. 1.2 Roof coverings
704A.1.3 Roof valleys
704A.1.5 Roof gutters
704A2.2 Eave or cornice vents
704A.2.3 Eavc pratcetion
704A.3.1.1 Exterior wall coverings
704A.3.2 Exterior wall openings
704A.3.2.1 Exterior wall vents
704A.3.2.2 Exterior glazing and window walls
704A.3.2.3 Exterior door assemblies
704A.4.1.1 Decking surfaces
704A.4.2.1 Underside of appendages and floor pwjcctions.
Unenclosed under floor rotection
er 15 Routing and RoofStructures
. 1503.1, 1503.3 Roof Coverin s within Slate Res onsibilil Area
4.704A.4.2.2
Kp
T`40 AW, LPGTank Clearance of Combustiibles
Protectin g LPG containers from vehicles
RE -INSPECTION DATES
INSPECTOR
RE -INSPECTION DATES
INSPECTOR
Ia
3r
2"
Inspection passed on:
✓✓Q
The above residential !—d'ancillary structure has been built to meet all applicable state and local fire safe standards including those
standards es ribed in Govemment Code Section 51189(6),
Inspector Signature
:alifornia Department of Forestry and Fire Protection
Butte County Fire Department
Fire Prevention Bureau
176 Nelson Avenue, Oroville, CA 95965
(530) 538-7888 Office, (530) 538-2105 Fax
Final Inspection Sheet/'' L11—
/%/ //n /
Property Ow ars Name: ` Property Location: �--aLi )'d (Lri(�tB !�. City: 4*7
Inspector: Inspecti Date:, ,Ry —/ :;l'— Permit# ,R/51- -nMy '� APN#Q(o.3 —Q,3p --OcFi�7
Correct Notes
1273.02 ❑ Roadway 0 Driveway Surfaces
1273.03 O Roadway 0 Driveway Grades
1273.04 0 Roadway 0 Driveway Radius
1273.05 O Roadway 0 Driveway Turnarounds
1273.06 O Roadway 0 Driveway Turnouts
1273.07 0 Roadway 0 Driveway Structures
1273.08 One -Way Roads
1273.09 Dead -End Roads
1273.11 0 Roadwa 0 Drivewa Gate Entrance
1274.01. Size of Letters, Numbers and Symbols for Street and Roads Signs
1274.03. Height of Street and Road Signs
11 1274.05. Intersecting Roads, Streets and Private Lanes
1274.06. Signs Identifying Traffic Access limitations
1274.07. Installation of Road, Street and Private Lane Si ms
1274.08. Addresses for Buildings
1274.09. Size of Letters, Numbers and Symbols for Addresses
1274.10.Insmllation, Location and Visibilij, of Addresses
1276.01 Setback for Structure Defensible Space
Same Practical Effect Requirements far buildin s less then 30 feet firomproperty line
1276.02 Dis osal of Flammable Ve elation and Fuels
c
If rc uired, renest to seen ca of the conversion ermit or Timber Harvest Plan
704A.1.2 Roof coverings
704A.1.3 Roof valleys
704A.1.5 Roof gotten
704A2.2 Eave or cornice vents
704A.2.3 Eave Protection
704A.3.1.I Exterior wall coverings
704A.3.2 Exterior wall openings
704A.3.2.1 Exterior wall vents
704A.3.2.2 Exterior glazing and window walls
704A.3.2.3 Exterior door assemblies
704A.4.1.1 Decking surfaces
704A.4.2.1 Underside of appendages and Boor projections.
704A.4.2.2 Unenclosed under Boor protection
Chapter 15 Roofing and Roof Structures
1503.1. 1503.2, 1503.3 Roof Coverin s within State Res onsibili Area
3807.3, LPG Tank Clearance of Combustibles
3807.4 Protecting LPG containers from vehicles
RE -INSPECTION DATES INSPECTOR
RF INSPECTION DATES
INSPECTOR
1"
3
2"JI
A a
Inspection passed on:
I
The above 0 residential kanci Lary structure as been built to meet all applicable state and local fire safe standards including those
sltandar s described in Government Code Section 51189(b).
Insp ccpttor"Signature