Loading...
HomeMy WebLinkAboutB17-1059 CALFIRE PRE AND FINAL INSPECTIONPermit # B17-1059 Butte County Fire Department Fire Prevention Bureau APN # 065-370-024 176 Nelson Avenue, Oroville CA 95965 (530) 538-7888 Office, (530) 538-2105 Fax Applicant Name: SCHUENEMEYER MARVIN T Permit Address: 14784 PINE CONE WAY, MAGALIA, CA 95954 Phone: 530-521-4177 Cell: Under authority of Public Resources Code (PRC) Section 4290 and 4291, Butte County Improvement Standards (BCIS), California Building Code (CBC), and the California Fire Code (CFC), and Chapter 38A Butte County Code, the following items are required by CAL FIRE/Butte County Fire Department for all development located within the State and Local Responsibility Areas of Butte County and are required as part of this permit. These requirements are minimums and may be superseded by Butte County local regulations exceeding these standards. This pre inspection is for: ❑ iKesidence ❑ Manufactured Home 0 Addition to existing structure ❑ Ancillary Building (detached garage, shop, shed, etc.) Public Resources Code 4290 ADMINISTRATION 1272;R6 Maintenance of Defensible Space Measures To ensure continued maintenance of properties in conformance with these standards and measures and to assure continued availability, access, and utilization of the defensible space provided for these standards during a wildfire, provisions for annual maintenance shall be included in the development plans and/or shall be provided as a condition of the permit, parcel or map approval. DRIVEWAY STANDARDS R73.10 Driveways (a) All new driveway construction or an extension of an existing driveway shall comply with Public Resources Code Jereoadway requirements. Driveways can only serve a single parcel. h of Driveway (b) All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance of 15 feet along its length. 12 73.02 Driveway Surface The surface shall provide unobstructed access to conventional drive vehicles, including sedans and fire engines. St rfaces should be established in conformance with local ordinances, and be capable of supporting a 40,000 pound load. 4" of class 2 aggregate base shall be required for all driveways, turnouts and turnarounds. 12 73.03 Driveway Grades The grade for all driveways shall not exceed 15% without being paved. Grades over 15% shall have 4" of class 2 Iate base and 2" of asphalt concrete. No driveways allowed in excess of 20%. 4 Driveway Radius (a) No roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional surface width of 4 all be added to curves of 50-100 feet radius; 2 feet to those from 100-200 feet. (b) The length of vertical curves in roadways, exclusive of gutters, ditches, and drainage structures designed to hold or water. shall be not less than 100 feet. Legend: N/A=Not Applicable, X=Required Revised on 04/10/17 Traldt Copy 05 Driveway Turnarounds (d) A turnaround shall be provided to all building sites on driveways over 300 feet in length, and shall be within 50 of the building. _Turnarounds are required on driveways and dead-end roads as specified in this article. The minimum turning radius for naround shall be 40 feet from the center line of the road. If a hammerhead -T is used, the top of the "T' shall be a imum of 60 feet in length. 3.06 Driveway Turnouts _(c) Driveways exceeding 150 feet in length, but less than 800 feet in length, shall provide a turnout near the midpoint le driveway. Where the driveway exceeds 800 feet, turnouts shall be provided no more than 400 feet apart. _Turnouts shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end. 3.07 Driveway Structures _(a) All driveway, road, street, and private lane roadway structures (Bridges, culverts, and other appurtenant structures .h supplement the roadway bed or shoulders) shall be constructed to carry at least the maximum load and provide the imum vertical clearance as required by Vehicle Code Sections 35550, 35750 and 35250. All bridges shall be certified i registered Civil Engineer. _(b) Appropriate signing, including but not limited to weight or vertical clearance limitations, one-way road or single conditions, shall reflect the capability of each bridge. r(c) A bridge with only one traffic lane may be authorized by the local jurisdiction; however, it shall provide for 3structed visibility from one end to the other and turnouts at both ends. GATESTANDARDS 127PA Gate Entrance _fo� (a) Gate entrances shall be at least two feet wider on both ends then the width of the traffic lane(s) serving that gate. Minimum 14 foot opening. _((b) All gates providing access from a road to a driveway shall be located at least 30 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on that road. Ac) Where a one-way road with a single traffic lane provides access to a gated entrance; a 40 foot turning radius shall be used. SIGNING AND BUILDING NUMBERING 1274.00. Intent To facilitate locating an emergency and to avoid delays in response, all newly constructed or approved roads, street, and buildings shall be designated by names or numbers, posted on signs clearly visible and legible from the roadway. This section shall not restrict the size of letters of numbers appearing on street signs for other purposes. ADDRESSING 1274.98. Addresses for Buildings ✓ All buildings shall be issued an address by the local jurisdiction which conforms to that jurisdiction's overall address system. Accessory buildings will not be required to have a separate address; however, each dwelling unit within a building shall be separately identified. 1274.98( Size of Letters, Numbers and Symbols for Addresses Size of letters, numbers and symbols for addresses shall be a minimum 4 inch letter height, 3/8 inch stroke, reflectorzed, contrasting with the background color of the sign. 127 0. Installation, Location and Visibility of Addresses (a) All buildings shall have a permanently posted address, which shall be placed at each driveway entrance and visible from both directions of travel along the road. In all cases, the address shall be posted at the beginning of construction and shall be maintained thereafter, and the address shall be visible and legible from the road on which the address is located. 2 Legend: N/A=Not Applicable, X=Required Revised on 04/10/17 Trakit Copy ADDRESSING (cont.) _44) Address signs along one-way roads shall be visible from both the intended direction of travel and the opposite dirton. -/[&nc Where multiple addresses are required at a single driveway, they shall be mounted on a single post. FUEL MODIFICATION STANDARDS 1276.00 Intent To reduce the intensity of a wildfire by reducing the volume and density of flammable vegetation, the strategic location of fuel modification and greenbelts shall provide: (1) Increased safety for emergency fire equipment and evacuating civilians; (2) A point of attack or defense from a wildfire. 1276.Q1 Setback for Structure Defensible Space SRA only [ ] f%Yy/� aa) All parcels I acre and larger shall provide a minimum 30 foot setback for buildings and accessory buildings from all property lines and/or the center of the road. 1276.0%J)isposal of Flammable Vegetation and Fuels lsposal, including chipping, burning or removal to a landfill site approved by the local jurisdiction, of flammable vegetation and fuels caused by site development and construction, road and driveway construction, and fuel modification shall be completed prior to completion of road construction or final inspection of a building permit. DEFENSIBLE SPACE GUIDELINES PubliS,R,esources Code 4291 A person that owns, leases, controls, operates, or maintains a building or structure in, upon, or adjoining any mountainous area, forest -covered lands, brush -covered lands, grass -covered lands, or any land that is covered with flammable matenal�s Il at all times do all of the following: (b) Maintain around and adjacent to the building or structure additional fire protection or firebreak made by removing all brush, flammable vegetation, or combustible growth that is located within 100 feet from the building or structure or to the property line or at a greater distance if required by state law, or local ordinance, rule, or regulation. Grass and other vegetation located more than 30 feet from the building or structure and less than 18 inches in height above the ground may be maintained where necessary to stabilize the soil and prevent erosion. This subdivision does not apply to single specimens of trees or other vegetation that is well-pnmed and maintained so as to effectively manage fuels and not form a means of rapidly transmitting fin: from other nearby vegetation to a dwelling or structure. (c) Remove that portion of any tree that extends within 10 feet of the outlet of a chimney or stovepipe. _Z(d) Maintain any tree adjacent to or overhanging a building free of dead or dying wood. Maintain the roof of a structure free of leaves, needles, or other dead vegetative growth. (f) Prior to constructing a new building or structure or rebuilding a building or structure damaged by a fire in such an area, the construction or rebuilding of which requires a building permit, the owner shall obtain a certification from the local building official that the dwelling or structure, as proposed to be built, complies with all applicable state and local building standards, including those described in subdivision (b) of Section 51189 of the Government Code, and shall provide a copy of the certification, upon request, to the insurer providing course of construction insurance coverage for the building or structure. Upon completion of the construction or rebuilding, the owner shall obtain from the local building official, a copy of the final inspection report that demonstrates that the dwelling or structure was constructed in compliance with all applicable state and local building standards, including those described in subdivision (b) of Section 51189 of the Government Code, and shall provide a copy of the report, upon request, to the property insurance carrier that insures the dwelling or structure. Legend: N/A=Not Applicable, X=Required Revised on 04/10/17 Trakit Copy Public Resources Code 4621 thru 4628 and California Forest Practice Rules Article 7 SRA only Prior to any lot clearing activity or cutting of trees, contact the Butte area Forester at (530) 872-6353 to determine the need for a less then 3 acre conversion exemption permit or a timber harvest plan. If required, a copy of the Timber Harvest Plan or less than 3 acre conversion exemption permit will need to be reviewed at the final inspection. ❑rmit required 2' -Permit not required 2016 California Fire Code LPG Tanks 6107 LPG Tank Clearance of Combustibles Weeds, grass, brush, trash and other combustible materials shall be kept a minimum of 10 feet from LP -gas tanks or containers. 6107.4Protecting LPG containers from vehicles Where exposed to vehicular damage due to proximity to alleys, driveways or parking areas, LP -gas containers, regulators and piping shall be protected in accordance with Section 312. Fire Department Fees ire department fees are collected by the Butte County Development Services Department at the time of application for your building permit. You are assessed two fees (pre -inspection and final inspection). Additional fees will be assessed when the fire department inspector is required to perform additional re -inspections of your property, those additional fees must be paid to Development Services, 7 County Center Drive in Oroville. California Building Code Chapter 7A, Materials and Construction Methods for Exterior Wildfire Exposure Check with Butte County Department of Development Services —Building Division for specific questions regarding Chapter 7A of the California Building Code and its application to your project. Also, check the websites below for useful information including the full text of Chapter 7A CBC. All of the Fire Safe Requirements, including Wildland Urban Interface (WUI) Products from the Office of the State Fire Marshal's office are posted on the Butte County Fire Department website at http://www.buttecounty.net/fiire Check the status of your permit online at http://dspermits.buttecounty.net/etrakit/Permit—Search.asp Need afire department inspection? Call our inspection line. (530) 538-6226 Inspector Daterope Owner or Contractors Signature _Marvin Schuenemeyer Owners Name 4 Legend: N/A=Not Applicable, X=Required Revised on 04/10/17 Trakit Copy restry and Fire Protection re Department !on Bureau Oroville, CA 95965 (530) 538-2105 Fax tion Sheet 16!7::F'q pztilg� City:'0/740 .1d Permit'# —It), �q APN# -3h -riaq Correct Notes � INSPECTOR 1 1273.02 [1 RoadwaVftftwsmmy 0 Driveway Surfaces 1273.03 0 Roadway D Driveway Grades 3r I 1273.04 0 Roadway 0 Driveway Radius 2'a 1273.05 0 Roadway 0 Driveway Turnarounds 1273.06 0 Roadway 11 Driveway Turnouts Aa- l'L'A0 I^ V 1273.07 0 Roadway 11 Driveway Structures 1273.08 One -Way Roads 1273.09 Dead -End Roads 1273.11 0 Roadway 0 Driveii Gate Entrance 11 EMME /f 1274,01. Size of Letters. Numbers and Symbols for Street and Roads Signs 1274.03. 1 feight of Street and Road Signs 1274.05. Intersecting Roads, Streets and Private Lanes 1274.06. Signs Identifying Traffic Access limitations 1274.07. Installation of Road, Street anJ Private Lane Sien. ---------- -- — --- 1274.08. Addresses for FlUildings . ......... . .......... 1274.09. Sim of Letters, Numbers and Symbols for Addrc,>, 1274. 10. Installation, Location and Visibill of Ad 1276.01 Setback for Structure Defensible Space Same Practical Effect Requirements for buildings less then 30 feet from property line 1276.02 Dis oral of Flammable Vcelation and Fuels 01. Cl 15 If rckred, re5ucst to scc, a co of the conversion Unit or Timber Harvest Plan 704A.1.2 Roof coverings 704A.1.3 Roof valleys 704A.I.5 Roof gutters 704A2.2 Eave or comice vents 704A.2.3 Eave protection 704A.3.1.1 Exterior wall coverings 704A.3.2 Exterior wall openings 704A.3.2.1 Exterior wall vents 704A.3.2.2 Exterior glazing and window walls 704A.3.2.3 Exterior door assemblies 704A.4. 1.1 DcckiT�-' surfaces 704A.4.2. i Underside of appendages and floor Projections. 704A.4.2.2 Unenclosed under floor protection "a and Roof Structures TILa 503T'El 36T2,EM.3 Roof Cover n s within State Res onsibili Area 3807.3, LPG Tank Clearance of Combustibles 3R07.4 Proteclin LPG containers from vehicles I RDATES INSPECTOR RE -INSPECTION DATES INSPECTOR ,'�[N,SPECTION 3r I 2'a 1 Inspection passed on: 4-11� Aa- l'L'A0 I^ The above residential 11 ancillary structure has been built to meet all applicable state and local fire safe standards including those stand ds described in Govcmment Code Section 51 189(6). Inspector Signature