HomeMy WebLinkAboutLD 1460-Transmittal-SD Leach Trench Ck 1 Taylor Department of Public Works Mike Crump, Director
Shawn H. O’Brien, Assistant Director
7 County Center Drive T: 530.538.7681
Oroville, California 95965 F: 530.538.7171
buttecounty.net/publicworks
November 16, 2015
Wendy Taylor
15430 Hwy 99 N #D
Chico, CA 95973
Re: Storm Drain Leach Trench Installation - APN 047-690-011
To Whom It May Concern:
With reference to the above subject, enclosed is:
Site Plans – check #1
ACTION REQUIRED:
Resubmit storm drain installation plans in accordance with changes below.
Review the following:
Remarks:
1. A plan check and inspection fee of $489 is required prior to approval.
2. Note 10 of Map Book 173 Page 39 requires 45 lineal feet of trench with percolation
dimensions of 24” deep by 36” wide per 1,000 square feet of hardscape. The reduced
trench percolation dimensions of 12” deep by 24” wide that you are proposing requires
195 total lineal feet of trench. The total length may be divided into two or three trenches.
3. Identify storm drain trenches and length of trench to be constructed on plan with text
because red pen photo copies black.
4. State on site plan that roof downspouts are to be connected to the storm drain leach
trench.
5. Attach county standard S-38 (enclosed) to the site plan.
NO ACTION REQUIRED:
Per your request.
If you should have any questions, please call (530) 538-7266, Monday through Friday, 7:30 a.m.
to 4:30 p.m.
Sincerely,
Eric Schroth, P.E., L.S.
Associate Civil Engineer
cc: Tom Fossum – Deputy Director Public Works Department