Loading...
HomeMy WebLinkAboutUP17-0007 - Plans Re-Submittal Set1.GET ON I-680 N FROM 2600 CAMINO RAMON, SAN RAMON, CA 94583 2.GET ON I-680 N FROM CAMINO RAMON AND BOLLINGER CANYON RD 3.HEAD SOUTHEAST ON CAMINO RAMON TOWARD BISHOP DR 4.CONTINUE STRAIGHT TO STAY ON CAMINO RAMON 5.TURN RIGHT ONTO BOLLINGER CANYON RD 6.USE THE RIGHT 2 LANES TO MERGE ONTO I-680 N VIA THE RAMP TO SACRAMENTO 7.CONTINUE ON I-680 N. TAKE I-80 E, CA-99 N AND CA-70 N TO STATE HWY 70 E/9TH ST IN MARYSVILLE 8.MERGE ONTO I-680 N 9.KEEP LEFT TO STAY ON I-680 N 10.KEEP LEFT AT THE FORK TO STAY ON I-680 N 11.KEEP LEFT AT THE FORK TO CONTINUE ON I-680 12.USE ANY LANE TO TAKE EXIT 71A TOWARD I-80 E/SACRAMENTO 13.MERGE ONTO I-80 E 14.KEEP LEFT AT THE FORK TO STAY ON I-80 E 15.KEEP RIGHT AT THE FORK TO STAY ON I-80 E, FOLLOW SIGNS FOR RENO 16.TAKE EXIT 86 FOR I-5 N TOWARD CA-99/REDDING 17.KEEP LEFT AT THE FORK, FOLLOW SIGNS FOR I-5 N AND MERGE ONTO CA-99 N/I-5 N 18.KEEP RIGHT TO CONTINUE ON CA-99 N, FOLLOW SIGNS FOR YUBA CITY/MARYSVILLE 19.KEEP RIGHT TO CONTINUE ON CA-70 N, FOLLOW SIGNS FOR MARYSVILLE/OROVILLE 20.TAKE CA-70 N TO LITTLE BEND CT IN BUTTE COUNTY 21.TURN RIGHT ONTO STATE HWY 70 E/9TH ST (SIGNS FOR OROVILLE) 22.USE ANY LANE TO TURN LEFT ONTO CA-70 N/B ST 23.CONTINUE TO FOLLOW CA-70 N 24.USE THE RIGHT 2 LANES TO TAKE THE EXIT TOWARD CA-70 N 25.CONTINUE ONTO CA-70 N 26.TURN RIGHT ONTO PINKSTON CANYON RD 27.TURN LEFT ONTO BIG BEND RD 28.SLIGHT LEFT TOWARD LITTLE BEND CT 29.TURN LEFT ONTO LITTLE BEND CT 30.10829 LITTLE BEND CT TITLE SHEET T-1 SHEET INDEX PROJECT INFORMATION TITLE SHEETT-1 APPROVALS APPROVED BY:INITIALS:DATE: VENDOR: LEASING / LANDLORD: R.F.: ZONING: CONSTRUCTION: POWER / TELCO: PG&E: CODE COMPLIANCE PROJECT DESCRIPTION PROJECT TEAM GENERAL CONTRACTOR NOTES DO NOT SCALE DRAWINGS THESE DRAWINGS ARE FORMATTED TO BE FULL SIZE AT 24" x 36". CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOBSITE AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT/ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR MATERIAL ORDERS OR BE RESPONSIBLE FOR THE SAME. DIRECTIONS FROM AT&T Property Information: Site Name: Big Bend - Little Bend Site Number: CVL01754 Search Ring: Big Bend FA#: 13787690 Site Address: 10829 Little Bend Court Oroville, CA 95965 A.P.N. Number: 058-730-032 Current Use: Proposed Use: TELECOMMUNICATIONS FACILITY Jurisdiction: COUNTY OF BUTTE Latitude: N 39º 41' 53.12" (39.698089) Longitude: W 121º 27' 48.87" (-121.463575) Ground Elevation: 2446.5 FT DIRECTIONS FROM AT&T's OFFICE AT 2600 CAMINO RAMON, SAN RAMON, CA DISABLED ACCESS REQUIREMENTS OCCUPANCY AND CONSTRUCTION TYPE OCCUPANCY : U (UNMANNED) CONSTRUCTION TYPE: V-B SITE NUMBER: CVL01754 ELEVATIONSA-4.1 A-4.2 AT&T: SITE SURVEY LS-1 ENLARGED ANTENNA PLAN & DETAILS A-3 SITE NAME: BIG BEND - LITTLE BEND 10829 LITTLE BEND COURT 2529,//(&$ JURISDICTION: COUNTY OF BUTTE VICINITY MAP SPECIAL INSPECTIONS REV B SITE TYPE: SELF SUPPORT / SHELTER Property Owner: ROBERT G. ST CARTIER PO BOX 4333 OROVILLE, CA 95965-0700 530 533 1688 RSTCARTIER@MAIL.COM Applicant / Lessee: AT&T MOBILITY 5001 EXECUTIVE PARKWAY, 4W550H SAN RAMON, CA 94583 contact: DAVID SCOTT email: js7845@att.com office ph: (415) 260-5617 Architect: BORGES ARCHITECTURAL GROUP, INC. 1478 STONE POINT DRIVE, SUITE 350 ROSEVILLE, CA 95661 contact: BRIAN K. WINSLOW email: brian@borgesarch.com ph: (916) 782-7200 PROPERTY DEVELOPMENT: SHORE 2 SHORE WIRELESS INC. 3553 S. COLVIN DRIVE LOOMIS, CA 95650 contact: CARL JONES email: carl@s2swireless.com cell: (916) 798-2275 Structural Engineer: NORM SCHEEL STRUCTURAL ENGINEER 5022 SUNRISE BLVD FAIR OAKS, CA 95628 contact: NORM SCHEEL email: norm@nsse.com ph: (916) 536-9585 Construction Manager: SAC Wireless 1401 Willow Pass, Suite 350 Concord, CA 94519 contact: WARREN BELLIS email: warren.bellis@sacw.com office ph:(510) 821-1520 RF Engineer: NP&E-RAN DESIGN & RF ENGINEERING contact: ALEX KERRIGAN email: ak440b@att.com ph: (415) 996-5686 Power Agency: PG&E CORPORATION 1 MARKET STREET, SPEAR TOWER SAN FRANCISCO, CA 94105-1126 ph: (800) 743-5000 Telephone Agency: AT&T CALIFORNIA 525 MARKET STREET SAN FRANCISCO, CA 94105 ph: (800) 310-2355 04/17/17 100% ZD Submittal T. LAW T-15515-26 B.K.W. CVL01754 A 03/20/17 90% ZD SUBMITTAL 5001 Executive Parkway San Ramon, California 94583 PREPARED FOR Pl o t D a t e : 6/ 2 3 / 2 0 1 7 5 : 2 8 : 3 4 P M F i l e N a m e T: \ 2 0 1 5 \ T - 1 5 5 1 5 _ S h o r e 2 S h o r e _ A T & T N S B \ C V L 0 1 7 5 4 - 2 6 \ C V L 0 1 7 5 4 B i g B e n d \ S h e e t s \ T - 1 T i t l e S h e e t . d w g P l o t t e d B y : To d d L a w r e n c e REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Consultant: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: 5550 Merrick Road, #302 Massapequa, NY 11758 Architect: 1478 STONE POINT DRIVE, SUITE 350 ROSEVILLE CA 95661 TEL FAX borgesarch.com 916 782 7200 916 773 3037 CVL01754 BIG BEND - LITTLE BEND B 04/14/17100% ZD SUBMITTAL SITE PLANA-1 B ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION, ACCESSIBILITY ACCESS IS NOT REQUIRED, IN ACCORDANCE WITH CALIFORNIA BUILDING CODE, CODE OF REGULATIONS, TITLE 24, PART 2, VOLUME 1, CHAPTER 11B, DIVISION 2, SECTION 11B-203.5 ELEVATIONS ENLARGED EQUIPMENT PLANA-2 B B B B B B A-5.1 EMERGENCY BACKUP GENERATOR SPECS SITE CONSTRUCTION OF AN UNMANNED TELECOMMUNICATIONS FACILITY. 1.INSTALL POWER / TELCO / FIBER TO SITE LOCATION 2.INSTALL 11'-5" x 12'-0" PRE-MANUFACTURED EQUIPMENT SHELTER WITH GENERATOR PATIO 3.INSTALL NEW GPS UNIT 4.INSTALL 135' SELF SUPPORTING LATTICE TOWER 5.INSTALL (4) ANTENNAS PER SECTOR, FOR A TOTAL OF (12) 6.INSTALL (23) RRH 7.INSTALL (4) SURGE SUPPRESSORS 8.INSTALL (3) FIBER TRUNK, (8) DC CABLES INSTALLED ON CABLE LADDER GOING UP TOWER 9.INSTALL 6'-0" TALL CHAIN LINK SITE FENCING WITH ANTI-CLIMB BARRIERS. 10.INSTALL 35kw PROPANE EMERGENCY BACKUP GENERATOR ON (P) SHELTER PATIO 11.INSTALL 499 GALLON PROPANE STORAGE TANK *NO GRADING REQUIRED B A-5.2 PROPANE STORAGE TANK SPECS & DETAILS B 1)2016 CALIFORNIA ADMINISTRATIVE CODE, CHAPTER 10, PART 1, TITLE 24 CODE OF REGULATIONS 2)2016 CALIFORNIA BUILDING CODE (CBC) WITH CALIFORNIA AMENDMENTS, BASED ON THE 2015 IBC (PART 2, VOL 1-2) 3)2016 CALIFORNIA RESIDENTIAL CODE (CRC) WITH APPENDIX H, PATIO COVERS, BASED ON THE 2015 IRC (PART 2.5) 4)2016 CALIFORNIA GREEN BUILDINGS STANDARDS CODE (CALGREEN) (PART 11) (AFFECTED ENERGY PROVISIONS ONLY 5)2016 CALIFORNIA FIRE CODE (CFC), BASED ON THE 2015 IFC, WITH CALIFORNIA AMENDMENTS (PART 9) 6)2016 CALIFORNIA MECHANICAL CODE (CMC), BASED ON THE 2015 UMC (PART 4) 7)2016 CALIFORNIA PLUMBING CODE (CPC), BASED ON THE 2015 UPC (PART 5) 8)2016 CALIFORNIA ELECTRICAL CODE (CEC) WITH CALIFORNIA AMENDMENTS, BASED ON THE 2015 NEC (PART 3) 9)2016 CALIFORNIA ENERGY CODE (CEC) 10)ANSI / EIA-TIA-222-H 11)2015 NFPA 101, LIFE SAFETY CODE 12)2016 NFPA 72, NATIONAL FIRE ALARM CODE 13)2016 NFPA 13, FIRE SPRINKLER CODE POWER SINGLE LINE DIAGRAM & PANEL SCHEDULEE-2 B 17 1"=40'-0" SITE PLAN (P) 12'-0" AT&T NON-EXCL U S I V E A C C E S S E A S E M E N T A-2 13(P) 35'-0" X 40'-0" AT&T LEASE AREA (1400 SQFT) SECTOR AZIMUTH 90 A SE C T O R AZ I M U T H 210 C LITTLE BE N D C O U R T APN: 058-730-031 S E C T O R A Z I M U T H 3 3 0 B (P) A T & T 5 ' - 0 " U.G. U . E A S E M E N T NO GRADING REQUIRED P R O P E R T Y B O U N D A R Y (P) POC FOR POWER & TELCO ON (E) WOOD POLE W/ TRANSFORMER (E) TREES P R O P E R T Y B O U N D A R Y PROPERTY BOUNDARY PROPERTY B O U N D A R Y APN: 058-730-032 APN: 058-740-032 APN: 058-730-033 APN: 058-730-006 (P) ENLARGED SITE PLAN (E) BUILDING (E) BUILDING (E) DRIVE WAY APPROXIMATE LOCATION OF (E) LEACH FIELD (P) POWER +/- 468' (P) TELCO +/- 465' 1 3 6 ' - 6 " 148'-7" (E) TREES TO BE REMOVED 04/17/17 100% ZD Submittal T. LAW T-15515-26 B.K.W. CVL01754 A 03/20/17 90% ZD SUBMITTAL 5001 Executive Parkway San Ramon, California 94583 PREPARED FOR Pl o t D a t e : 6/ 2 3 / 2 0 1 7 5 : 2 1 : 3 1 P M F i l e N a m e T: \ 2 0 1 5 \ T - 1 5 5 1 5 _ S h o r e 2 S h o r e _ A T & T N S B \ C V L 0 1 7 5 4 - 2 6 \ C V L 0 1 7 5 4 B i g B e n d \ S h e e t s \ A - 1 S i t e P l a n . d w g P l o t t e d B y : To d d L a w r e n c e REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Consultant: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: 5550 Merrick Road, #302 Massapequa, NY 11758 Architect: 1478 STONE POINT DRIVE, SUITE 350 ROSEVILLE CA 95661 TEL FAX borgesarch.com 916 782 7200 916 773 3037 CVL01754 BIG BEND - LITTLE BEND B 04/14/17100% ZD SUBMITTAL SITE PLAN A-11"=40'-0" 40'20'40'80'00 NORTH PL A N N O R T H x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 13 1/4" = 1'-0" ENLARGED EQUIPMENT LAYOUT A-3 5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 5 2 3 4 6 7 8 9 10 12 11 14 13 26 25 1 15 15 16 17 18 19 23 24 (P) ANTENNA PLAN KEYNOTES (P) 11'-5"x12'-0" PREMANUFACTURED CALIFORNIA & AT&T EQUIPMENT SHELTER WITH GENERATOR PATIO (P) SERVICE DISCONNECT (P) GENERATOR PATIO (P) LTE RACK (P) TELCO CAN (P) 42 CIRCUIT LOAD CENTER WITH MANUAL & AUTOMATIC TRANSFER SWITCH (P) 200 AMP POWER METER (P) 200A CAM-LOK (P) GPS UNIT (P) 35kW PROPANE GENERATOR (P) U.G. TELCO RUN- ± 465' (P) ICE BRIDGE (P) HVAC (P) SHELTER ACCESS DOOR (P) U.G POWER RUN- ± 468' 3'-0" UG UTILITY EASEMENT FOR POWER AND TELCO (P) 6'-0" TALL CHAIN LINK FENCE w/ ANTI-CLIMB BARRIER (P) TELCO RACK (P) POWERPLANT RACK w/ BATTERIES (P) CABLE PORT (P) 135' SELF SUPPORT LATTICE TOWER NOTE: ALL UNDERGROUND UTILITIES IN AREA TO BE VERIFIED PRIOR TO TRENCHING NO GRADING REQUIRED (P) TELCO BOARD w/ 48" TELCO SPACE (P) 12'-0" WIDE DOUBLE SWING ACCESS GATE w/ ANTI- CLIMB BARRIER (P) 499 GALLON PROPANE FUEL TANK (P) SITE LIGHTING ( P ) A T & T 5 ' - 0 " U . G . U . E A S E M E N T (P) CONCRETE STOOP 40 ' - 0 " P R O P O S E D A T & T L E A S E A R E A 35'-0" PROPOSED AT&T LEASE AREA 12'-0"8'-0" 11 ' - 5 " 2' - 0 " (P) AT&T LEASE AREA 35' X 40" (1400 SQFT) R10'- 0 " S P A R K G A P 20 21 22 10'-0" 27 27 (P) KNOX BOX (P) A T & T 1 2 ' - 0 " NON - E X C L U S I V E A C C E S S E A S E M E N T 28 (P) REMOVAL OF (E) TREE 29 28 29 (E) TREES 29 29 29 29 04/17/17 100% ZD Submittal T. LAW T-15515-26 B.K.W. CVL01754 A 03/20/17 90% ZD SUBMITTAL 5001 Executive Parkway San Ramon, California 94583 PREPARED FOR Pl o t D a t e : 6/ 2 3 / 2 0 1 7 5 : 2 1 : 1 6 P M F i l e N a m e T: \ 2 0 1 5 \ T - 1 5 5 1 5 _ S h o r e 2 S h o r e _ A T & T N S B \ C V L 0 1 7 5 4 - 2 6 \ C V L 0 1 7 5 4 B i g B e n d \ S h e e t s \ A - 2 P r o p o s e d E n l a r g e d E q u i p m e n t P l a n . d w g P l o t t e d B y : To d d L a w r e n c e REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Consultant: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: 5550 Merrick Road, #302 Massapequa, NY 11758 Architect: 1478 STONE POINT DRIVE, SUITE 350 ROSEVILLE CA 95661 TEL FAX borgesarch.com 916 782 7200 916 773 3037 CVL01754 BIG BEND - LITTLE BEND B 04/14/17100% ZD SUBMITTAL PROPOSED ENLARGED EQUIPMENT PLAN A-21/4"=1'-0" 02'4'4'8'0 NORTH PL A N N O R T H 8 1/2" = 1'-0" RF SCHEDULE SECTOR A L P H A B E T A G A M M A ANTENNA MODEL NO.AZIMUTH RAD CENTER RRH FIBER LENGTH COAX LENGTH COAX DIA.NO. RF SCHEDULE A1 90°± 131'-0"± 170'-0"±10'-0"21/2" A2 A3 A4 B1 330° B2 B3 B4 C1 210° C2 C3 C4 TMA NA ±10'-0" ±10'-0" ±10'-0" ±10'-0" ±10'-0" ±10'-0" ±10'-0" ±10'-0" ±10'-0" ±10'-0" ±10'-0" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 2 2 2 2 2 2 2 2 2 2 2 NA NA NA NA NA NA NA NA NA NA NA (1) RRUS-11 / (1) RRUS-32 210° 210° 210° 90° 90° 90° 330° 330° 330° ± 170'-0" ± 170'-0" ± 170'-0" ± 170'-0" ± 170'-0" ± 170'-0" ± 170'-0" ± 170'-0" ± 170'-0" ± 170'-0" ± 170'-0" QUINTEL QS6656-3 QUINTEL QS6656-3 QUINTEL QS6656-3 QUINTEL QS6656-3 (1) RRUS-11 / (1) RRUS-12 / (1) RRUS-32 (1) RRUS-32 (1) RRUS-32 QUINTEL QS6656-3 QUINTEL QS6658-3 CCI HBSAM65R-KU-H6 CCI HBSAM65R-KU-H6 (1) RRUS-11 / (1) RRUS-32 (1) RRUS-12 / (1) RRUS-32 (1) RRUS-32 (1) RRUS-11 (1) RRUS-11 / (1) RRUS-32 (1) RRUS-11 / (1) RRUS-12 / (1) RRUS-32 (1) RRUS-32 (1) RRUS-32 QUINTEL QS6656-3 QUINTEL QS6658-3 CCI HBSAM65R-KU-H6 CCI HBSAM65R-KU-H6 ± 131'-0" ± 131'-0" ± 131'-0" ± 131'-0" ± 131'-0" ± 131'-0" ± 131'-0" ± 131'-0" ± 131'-0" ± 131'-0" ± 131'-0" 16 3/4" = 1'-0" ANTENNA MOUNTING DETAIL THE NUMBER OF CONNECTORS WILL VARY BASED ON ANTENNA TYPE. - MINIMUM 4 BOLTS PER ANTENNA NOTES 1). ANTENNA BRACKET PARTS: ITEM 2 1 QTY 1 1 1 PIPE MOUNT (TYP) DESCRIPTION 2 PANEL ANTENNA (TYP) VERIFY WITH RF DATA SHEET OPTIONAL DOWNTILT BRACKET CONTRACTOR TO VERIFY EXACT PARTS LIST AND ANTENNA INSTALLATION WITH MANUFACTURERS SPECIFICATIONS AND CONSTRUCTION MANAGER DOWNTILT BRACKET BOLT SPECIFICATION: (2) 3/8" A307 BOLT BOLT SPECIFICATION: (2) 3/8" A307 BOLT MINIMUM BOLT TORQUE 3/8" DIA. GALV. 16 FT-LB 1/2" DIA. GALV. 40 FT-LB 5/8" DIA. GALV. 79 FT-LB 5 1/2" = 1'-0" ENLARGED ANTENNA PLAN (P) AT&T SURGE SUPPRESSION UNIT , TYP. OF (4) (P) 135'-0" TALL SELF SUPPORTING LATTICE TOWER SECTOR AZIMUTH 90 A SE C T O R AZ I M U T H 21 0 C S E C T O R A Z I M U T H 3 3 0 B 12 ' - 6 " A N T E N N A S E C T O R F R A M E (P) AT&T PANEL ANTENNA, TYP OF (4) PER SECTOR (12) TOTAL (P) (23) AT&T RRH 4'- 0 " 4'- 0 " 4'- 0 " 4'-0" 4'-5" 5'-7" 14'-6 " A N T E N N A S E C T O R F R A M E 6'- 0 " 4'- 0 " 4'- 0 " 14' - 6 " A N T E N N A S E C T O R F R A M E 17 3/4" = 1'-0" QUINTEL QS6656-3 WIND AREA: ANTENNA: 6.00 SQ.FT. QUINTEL QS6656-3 HEIGHT: WIDTH: DEPTH: 72.0" 12.0" 9.6" WEIGHT: TOP FRONT 12" 72 " 9.6" SIDE 65 lb 18 3/4" = 1'-0" QUINTEL QS6658-3 WIND AREA: ANTENNA: 6.00 SQ.FT. QUINTEL QS6658-3 HEIGHT: WIDTH: DEPTH: 72.0" 12.0" 9.6" WEIGHT: TOP FRONT 12" 72 " 9.6" SIDE 65 lb 19 3/4" = 1'-0" CCI HBSA M65R-KU-H6-K WIND AREA: ANTENNA: 6.53 SQ.FT. CCI HBSA-M65R-KU-H6 HEIGHT: WIDTH: DEPTH: 68.1" 13.7" 8.5" WEIGHT: TOP FRONT 13.7" 68 . 1 " 8.5" SIDE 44.5 lb 13 1 1/2" = 1'-0" RRUS-32 ERICSSON RRUS-32 MODEL:RRUS 32, 32-B2 32-B66 COLOR:WHITE DIMENSIONS:26.7" TALL X 12.1" WIDE X 6.7" DEEP (INCLUDING SUNSHIELD) WIEGHT:+/- 69 LBS. (INCLUDING MOUNTING HARDWARE) 12.1" 26 . 7 " 6.7" FRONT VIEW SIDE VIEW TOP VIEW 16 " CL R 12 " CL R SUNSHIELD MFR'S STANDARD MOUNTING BRACKETS SUNSHIELD MFR'S STANDARD MOUNTING BRACKETS DUAL SWIVEL MOUNTING BRACKETS DUAL SWIVEL MOUNTING BRACKETS 9 1 1/2" = 1'-0" RRUS-11 ERICSSON RRUS 11 REMOTE RADIO UNIT COLOR:WHITE DIMENSIONS:19.7" TALL X 17" WIDE X 7.25" DEEP (INCLUDING SUNSHIELD) WIEGHT:+/- 50 LBS. (INCLUDING MOUNTING HARDWARE) RRUS 11 WITH SUNSHIELD ERICSSON /// 17" 19 . 7 " 7.25" FRONT VIEW SIDE VIEW MFR'S STANDARD MOUNTING BRACKETS TOP VIEW 16 " CL R 12 " CL R P1000 UNISTRUT AS ALTERNATE ATTACHMENT SUNSHIELD DUAL SWIVEL MOUNTING BRACKETS MFR'S STANDARD MOUNTING BRACKETS DUAL SWIVEL MOUNTING BRACKETS 15 1 1/2" = 1'-0" DC SURGE SUPPRESSION STANDARD GALVANIZED PIPE MOUNT 11" 11" 9" 2'- 3 " GROUND TO ANTENNA GROUND BAR OR BUILDING STEEL DC-6 SURGE SUPPRESSION MFR STANDARD CLIPS STANDARD GALVANIZED PIPE MOUNT MFR STANDARD PIPE MOUNT HARDWARE RAYCAP DC6-48-60-18-8F SURGE SUPPRESSION COLOR:BLACK/SILVER DIMENSIONS:11" DIA X 27" TALL W/ 9" BASE WEIGHT:+/- 50 LBS. (INCLUDING MOUNTING HARDWARE) DC-6 SURGE SUPPRESSION FIBER & DC POWER LINES TO RRH MFR STANDARD PIPE MONT HARDWARE 11 1 1/2" = 1'-0" RRUS 12 RRUS 12 WITH SUNSHIELD 18.5" 20 . 4 " 7.25" FRONT VIEW SIDE VIEW MFR'S STANDARD MOUNTING BRACKETS TOP VIEW 16 " CL R 12 " CL R P1000 UNISTRUT AS ALTERNATE ATTACHMENT SUNSHIELD DUAL SWIVEL MOUNTING BRACKETS MFR'S STANDARD MOUNTING BRACKETS DUAL SWIVEL MOUNTING BRACKETS ERICSSON /// ERICSSON RRUS-12 W/ A2 REMOTE RADIO UNIT COLOR:WHITE DIMENSIONS:20.4" TALL X 18.5" WIDE X 11" DEEP (INCLUDING SUNSHIELD) WIEGHT:+/- 65 LBS. (INCLUDING MOUNTING HARDWARE) 04/17/17 100% ZD Submittal T. LAW T-15515-26 B.K.W. CVL01754 A 03/20/17 90% ZD SUBMITTAL 5001 Executive Parkway San Ramon, California 94583 PREPARED FOR Pl o t D a t e : 6/ 2 2 / 2 0 1 7 5 : 3 6 : 4 2 P M F i l e N a m e T: \ 2 0 1 5 \ T - 1 5 5 1 5 _ S h o r e 2 S h o r e _ A T & T N S B \ C V L 0 1 7 5 4 - 2 6 \ C V L 0 1 7 5 4 B i g B e n d \ S h e e t s \ A - 3 A n t e n n a P l a n s & D E T A I L S . d w g P l o t t e d B y : To d d L a w r e n c e REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Consultant: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: 5550 Merrick Road, #302 Massapequa, NY 11758 Architect: 1478 STONE POINT DRIVE, SUITE 350 ROSEVILLE CA 95661 TEL FAX borgesarch.com 916 782 7200 916 773 3037 CVL01754 BIG BEND - LITTLE BEND B 04/14/17100% ZD SUBMITTAL ANTENNA PLANS & DETAILS A-31/2"=1'-0" 01'2'2'4'0 NORTH PL A N N O R T H (P) 130' SELF SUPPORT TOWER (P) (3) FIBER TRUNKS (P) 499 GALLON PROPANE TANK (P) GPS UNIT (P) AT&T 11'-5" X 12'-0" PRE MANUFACTURED EQUIPMENT SHELTER W/ PATIO (P) ICE BRIDGE (P) AT&T PANEL ANTENNA, (12) TOTAL (P) RRH, (23) TOTAL (P) ANTENNA SECTOR FRAME (P) 35kw PROPANE GENERATOR 13 3/16" = 1'-0" PROPOSED EAST ELEVATION +/- 0'-0" GRADE (P) (8) DC CABLES NOTE: NO GRADING REQUIRED ON THIS PROJECT (P) DC-6 (4) TOTAL (P) 6' CHAIN LINK FENCE W/ ANTI CLIMB +/- 135'-0" TOP OF (P) SELF SUPPORT TOWER +/- 131'-0" AT&T RAD CENTER OF (P) ANTENNAS +/- 134'-0" AT&T TOP OF (P) ANTENNAS 5 3/16" = 1'-0" PROPOSED SOUTH ELEVATION (P) 130' SELF SUPPORT TOWER (P) (3) FIBER TRUNKS (P) (8) DC CABLES (P) CABLE LADDER (P) GPS UNIT (P) AT&T 11'-5" X 12'-0" PRE MANUFACTURED EQUIPMENT SHELTER W/ PATIO +/- 0'-0" GRADE NOTE: NO GRADING REQUIRED ON THIS PROJECT (P) 499 GALLON PROPANE TANK (P) 35kw PROPANE GENERATOR (P) 6' CHAIN LINK FENCE W/ ANTI CLIMB (P) AT&T PANEL ANTENNA, (12) TOTAL (P) RRH, (23) TOTAL (P) ANTENNA SECTOR FRAME (P) DC-6 (4) TOTAL +/- 135'-0" TOP OF (P) SELF SUPPORT TOWER +/- 131'-0" AT&T RAD CENTER OF (P) ANTENNAS +/- 134'-0" AT&T TOP OF (P) ANTENNAS 04/17/17 100% ZD Submittal T. LAW T-15515-26 B.K.W. CVL01754 A 03/20/17 90% ZD SUBMITTAL 5001 Executive Parkway San Ramon, California 94583 PREPARED FOR Pl o t D a t e : 4/ 1 4 / 2 0 1 7 2 : 4 6 : 4 6 P M F i l e N a m e T: \ 2 0 1 5 \ T - 1 5 5 1 5 _ S h o r e 2 S h o r e _ A T & T N S B \ C V L 0 1 7 5 4 - 2 6 \ C V L 0 1 7 5 4 B i g B e n d \ S h e e t s \ A - 4 . 1 E L E V A T I O N S . d w g P l o t t e d B y : Br i a n W i n s l o w REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Consultant: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: 5550 Merrick Road, #302 Massapequa, NY 11758 Architect: 1478 STONE POINT DRIVE, SUITE 350 ROSEVILLE CA 95661 TEL FAX borgesarch.com 916 782 7200 916 773 3037 CVL01754 BIG BEND - LITTLE BEND B 04/14/17100% ZD SUBMITTAL ELEVATIONS A-4.1 8'4'8'16'0 3/16"=1'-0" 8'4'8'16'0 3/16"=1'-0" +/- 0'-0" GRADE +/- 135'-0" TOP OF (P) SELF SUPPORT TOWER +/- 131'-0" AT&T RAD CENTER OF (P) ANTENNAS (P) 130' SELF SUPPORT TOWER (P) (3) FIBER TRUNKS (P) ICE BRIDGE (P) AT&T 11'-5" X 12'-0" PRE MANUFACTURED EQUIPMENT SHELTER W/ PATIO (P) GPS UNIT 5 3/16" = 1'-0" PROPOSED NORTH ELEVATION (P) (8) DC CABLES NOTE: NO GRADING REQUIRED ON THIS PROJECT +/- 134'-0" AT&T TOP OF (P) ANTENNAS (P) 499 GALLON PROPANE TANK (P) 6' CHAIN LINK FENCE W/ ANTI CLIMB (P) 35kw PROPANE GENERATOR (P) DC-6 (4) TOTAL (P) ANTENNA SECTOR FRAME (P) AT&T PANEL ANTENNA, (12) TOTAL (P) RRH (23) TOTAL 04/17/17 100% ZD Submittal T. LAW T-15515-26 B.K.W. CVL01754 A 03/20/17 90% ZD SUBMITTAL 5001 Executive Parkway San Ramon, California 94583 PREPARED FOR Pl o t D a t e : 4/ 1 4 / 2 0 1 7 2 : 4 7 : 3 5 P M F i l e N a m e T: \ 2 0 1 5 \ T - 1 5 5 1 5 _ S h o r e 2 S h o r e _ A T & T N S B \ C V L 0 1 7 5 4 - 2 6 \ C V L 0 1 7 5 4 B i g B e n d \ S h e e t s \ A - 4 . 2 P r o p o s e d E l e v a t i o n s . d w g P l o t t e d B y : Br i a n W i n s l o w REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Consultant: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: 5550 Merrick Road, #302 Massapequa, NY 11758 Architect: 1478 STONE POINT DRIVE, SUITE 350 ROSEVILLE CA 95661 TEL FAX borgesarch.com 916 782 7200 916 773 3037 CVL01754 BIG BEND - LITTLE BEND B 04/14/17100% ZD SUBMITTAL ELEVATIONS A-4.2 8'4'8'16'0 3/16"=1'-0" EMERGENCY BACKUP GENERATOR SPECS 04/17/17 100% ZD Submittal T. LAW T-15515-26 B.K.W. CVL01754 A 03/20/17 90% ZD SUBMITTAL 5001 Executive Parkway San Ramon, California 94583 PREPARED FOR Pl o t D a t e : 4/ 1 4 / 2 0 1 7 2 : 4 8 : 2 7 P M F i l e N a m e T: \ 2 0 1 5 \ T - 1 5 5 1 5 _ S h o r e 2 S h o r e _ A T & T N S B \ C V L 0 1 7 5 4 - 2 6 \ C V L 0 1 7 5 4 B i g B e n d \ S h e e t s \ A - 5 . 1 G e n e r a t o r S p e c s . d w g P l o t t e d B y : Br i a n W i n s l o w REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Consultant: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: 5550 Merrick Road, #302 Massapequa, NY 11758 Architect: 1478 STONE POINT DRIVE, SUITE 350 ROSEVILLE CA 95661 TEL FAX borgesarch.com 916 782 7200 916 773 3037 CVL01754 BIG BEND - LITTLE BEND A-5.1 11 3/4" = 1'-0" PROPANE TANK FOUNDATION NOTE: MAINTAIN MINIMUM 3" COVER AT ALL REINFORCING STEEL PREPARE SUBGRADE AS SPECIFIED BY GEOTECHNICAL ENGINEER'S REPORT 1" 45° CHAMFER AT SLAB EDGE - TYP ALL SIDES LINE OF GENERATOR TANK ASSEMBLY TYPICAL ANCHORAGE; HILTI KB-TZ STAINLESS STEEL 1/2" DIA. X 3 14" LONG EMBEDMENT EXPANSION ANCHOR (TYPICAL 4 LOCATIONS) 11'-0" 4' - 0 " 1" 45° CHAMFER AT SLAB EDGE - TYP ALL SIDES 1' - 0 " 6" 6" MOUNTING BOLT LOCATIONS FOR STORAGE TANK GRADE 40 #4 BARS @ 18" O.C. EACH WAY 11'-0" x 4'-0", 2500 PSI, 12" THICK CONCRETE SLAB DASHED LINE INDICATES LOCATION OF PROPANE GENERATOR STORAGE TANK - REFER TO STORAGE TANK DETAILS FOR DIMENSIONS AND NOTES 13 NOT TO SCALE LP PROPANE STORAGE TANK 60"11"11" SIDE ELEVATION 119" 1'-6 17/32" 5 1'-6" GENERAL SPECIFICATIONS WATER CAPACITY GALLONS 499 ALLOWABLE WORKING PRESSURE (PSIG)250 JOINT EFFICIENCY ASME UW-51 LONG SEAM 100% ASME UW-52 HEAD TO SHELL 80% HYDROSTATIC TEST PRESSURE (PSIG)325 SURFACE AREA (SQ FT )97.5 RELIEF VALVE SETTING (PSIG)250 RELIEF DISCHARGE RATE (CFM REQ'D)2290 CODE ASME SECTION VIII DIV 1 MATERIAL SPECS COUPLINGSSA-105 TANK FLANGE SA-105 ADAPTOR SA-105 END VIEW TOP VIEW (5E - 499CAL) MARK QTY SIZE SERVICE A 1 1 RELIEF VAULVE B 1 1 FLOAT GAUGE C 1 1 1/4 FILL VALVE FITTINGS D 1 1/4 OUT GAGE VALVE E 1 3/4 SERVICE VALVE F 1 3/4 CHEK-LOC G 1 3/4 VAPOR VALVE J 1 1 1/4 PLUGGED OPENING W/ PLUG MARK QTY DESCRIPTION FITTINGS 1 1 SHELL- 0.218"x81 1/2"x117 3/4" 2 2 HEADS- 37" I D x 0.185" 3 2 LIFTING LUGS 4 4 TANK LEGS 5 1 DOME 6 1 DATA PLATE 7 2 RELIFE VALVE GAURD- 1/2" O.D. STEEL BAR 8 1 DIP TUBE LENGTH = 10.7" FOR 80% AT 40 F 9 2 REGULATOR BRACKET HINGE HASP 7 3A3 2"2" 33 5 HINGE HASP 2 37 " I . D . 4 41 41" 82" 4"4" 8 FLOAT GAUGE TYP3/16" TYP 3/16" J FITTING LAYOUT 16" 19 1/4" TYP 3/16" J 3/4" DIA. HOLES (4) PLACES 5 CL CL SLOT IN DOME 3 1 / 2 " 3 1 / 2 " HINGE HASP 6 4 1/2"4 1/2" G B 9 C F D E CL 04/17/17 100% ZD Submittal T. LAW T-15515-26 B.K.W. CVL01754 A 03/20/17 90% ZD SUBMITTAL 5001 Executive Parkway San Ramon, California 94583 PREPARED FOR Pl o t D a t e : 4/ 1 4 / 2 0 1 7 2 : 4 9 : 0 0 P M F i l e N a m e T: \ 2 0 1 5 \ T - 1 5 5 1 5 _ S h o r e 2 S h o r e _ A T & T N S B \ C V L 0 1 7 5 4 - 2 6 \ C V L 0 1 7 5 4 B i g B e n d \ S h e e t s \ A - 5 . 2 P r o p o s e d S t o r a g e T a n k S p e c s & D e t a i l s . d w g P l o t t e d B y : Br i a n W i n s l o w REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Consultant: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: 5550 Merrick Road, #302 Massapequa, NY 11758 Architect: 1478 STONE POINT DRIVE, SUITE 350 ROSEVILLE CA 95661 TEL FAX borgesarch.com 916 782 7200 916 773 3037 CVL01754 BIG BEND - LITTLE BEND B 04/14/17100% ZD SUBMITTAL PROPOSED STORAGE TANK SPECS & DETAILS A-5.2 04/17/17 100% ZD Submittal T. LAW T-15515-26 B.K.W. CVL01754 A 03/20/17 90% ZD SUBMITTAL 5001 Executive Parkway San Ramon, California 94583 PREPARED FOR Pl o t D a t e : 4/ 1 4 / 2 0 1 7 2 : 4 9 : 3 5 P M F i l e N a m e T: \ 2 0 1 5 \ T - 1 5 5 1 5 _ S h o r e 2 S h o r e _ A T & T N S B \ C V L 0 1 7 5 4 - 2 6 \ C V L 0 1 7 5 4 B i g B e n d \ S h e e t s \ E - 2 P o w e r S i n g l e L i n e D i a g r a m . d w g P l o t t e d B y : Br i a n W i n s l o w REV DESCRIPTIONDATE SHEET TITLE: SHEET NUMBER: CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Consultant: AT&T Site ID: Licensor: Issued For: AT&T SITE NO: 5550 Merrick Road, #302 Massapequa, NY 11758 Architect: 1478 STONE POINT DRIVE, SUITE 350 ROSEVILLE CA 95661 TEL FAX borgesarch.com 916 782 7200 916 773 3037 CVL01754 BIG BEND - LITTLE BEND B 04/14/17100% ZD SUBMITTAL POWER SINGLE LINE DIAGRAM & PANEL SCHEDULE E-2 ABBREVIATIONS: AGC AUTOMATIC GENERATOR CONTROLLER BCW BARE COPPER WIRE BTS BASE TRANSCEIVER STATION C CONDUIT (E)EXISTING EG EQUIPMENT GROUND (F)FUTURE FACP FIRE ALARM CONTROL PANEL GEN GENERATOR IG ISOLATED GROUND IMC INTERMEDIATE METAL CONDUIT LFMC LIQUID TIGHT FLEXIBLE METAL CONDUIT MCM MILLION CIRCULAR MILLS MI MECHANICAL INTERLOCK MP&S SEE MECHANICAL PLANS & SPECIFICATIONS (N)NEW NEMA NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION NL NIGHT LIGHT - FIXTURE TO BE UNSWITCHED PFB PROVISION FOR FUTURE BREAKER PVC POLYVINYL CHLORIDE CONDUIT (R)RELOCATE RG RELAY TO MONITOR GENERATOR POWER RU RELAY TO MONITOR UTILITY POWER TYP TYPICAL UON UNLESS OTHERWISE NOTED WP WEATHERPROOF GFCI GROUND FAULT CIRCUIT INTERRUPTER NOTE:SYMBOLS INDICATED ABOVE MAY NOT NECESSARILY APPEAR AS PART OF THESE DRAWINGS IF NOT REQUIRED. 16 N.T.S. SINGLE LINE DIAGRAM 4 N.T.S. ABBREVIATIONS LEGEND: MI = MECHANICAL INTERLOCK RU = RELAY TO MONITOR UTILITY POWER RG = RELAY TO MONITOR GENERATOR POWER 200A, 1 PHASE GENERATOR CAMLOK INTERFACE PANEL DISTRIBUTION PANEL 200 AMP, 1 PHASE, 120/240V AC SLIDE BAR TRANSFER DEVICE, 42 POSITION LOAD CENTER, 20 AMP GFI RECEPTACLE, AC SURGE ARRESTOR WITH ALARMS, CIENA #2 AWG GROUND MI RU N TELEPHONE COMPANY SERVICE RELAY ALARM CABLES FROM PANEL TO TELCO BOX G M FIBER BOX 2" C 2" C (3) #3/0, (1) #2 GROUND 200/2 (1) 3" C (2) 4/0 THWN AL (1) 1/0 AL NEUTRAL SURGE ARRESTER 30/2 #2 GROUNDING ELECTRODE CONDUCTOR TO GROUND RING METER AND MAIN BREAKER #2 AWG SUPPLEMENTAL, EQUIPMENT GROUND CONDUCTOR TO GROUND BAR. GROUND HALO #2 BOND TO GROUND HALO MASTER GROUND BAR #2 AWG EQUIPMENT GROUND CONDUCTOR TO GROUND HALO. EMERSON DC POWER RACK DUW/DUL RACK w/ SURGE SUPPRESSION 48V DC CABLE AS REQUIRED EXOTHERMIC WELD TRANSPORT RACK w/ SIAD 48V DC CABLE AS REQUIRED (1) 1" C (3) #8 THWN CU (1) #10 GROUND NOTE: FOR GROUNDING SYSTEM SEE SHEET G-1 RRU -48V DC 48V DC CABLE AS REQUIRED 2" C TYPICAL WITH (3) 4 PAIR CAT 5 STP FOR TELCO SERVICE (1) 26 CONDUCTOR EXTERNAL ALARM CABLE SEE PLAN FOR NUMBER OF RUNS SEE PANEL SCHEDULE FOR BREAKERS AND LOADS. N G #2 GROUNDING ELECTRODE, #2 BOND TO GROUNDING ROD 2" C (3) #3/0 (1) #2 GROUND TO GROUND RING 200/2 - TYPICAL OF 3 BREAKERS 200A, 1 PHASE 35KW SG035 PROPANE GENERATOR 2" C (3) #3/0 (1) #2 GROUND 200/2 RG (3) #12 THWN CU & (1) #12 CU GND IN 1" C. FOR BLOCK HEATER & BATTERY CHARGER. 1" C. FOR AUTOSTART CONTROLLER W/ (2) #12 #2 TINNED BCW GROUND GENERATOR CHASSIS TO GROUND RING BELOW 9 N.T.S. SHELTER A/C PANEL SCHEDULE NOTES: 1.ALL WIRE TO BE #12 THHN/THWN UNLESS NOTED OTHERWISE. COLOR CODE: ·AO = BLACK ·BO = RED ·NEUTRAL = WHITE ·GROUND = GREEN 2.ALL WORK TO CONFORM TO N.E.C. LATEST STATE ADOPTED EDITION. 3.LABEL SERVICE DISCONNECT WITH A RED TAG. 4. SWITCH LEG CONDUCTORS SHALL BE THE SAME COLOR AS CIRCUIT CONDUCTORS. 5.PULL WIRES TO END OF FLEXIBLE NONMETALLIC CONDUIT. COIL 3'-0" AT END OF FLEXIBLE NONMETALLIC CONDUIT & TAG. 6.PULL ONE GROUND CONDUCTOR PER FLEXIBLE NONMETALLIC CONDUIT. FOR ALL OTHER CIRCUITS PULL A SEPARATE CONDUCTOR. 7.ALL GFCI RECEPTACLES TO HAVE A DEDICATED GROUND WIRE. 8.EQUIPMENT TERMINATION LUGS AND CONDUCTORS ARE RATED AT A MINIMUM OF 75°C. KEY: = PHOTOCELL = MOTION DETECTOR PC M - # = CONDUIT GROUND = NON-DEDICATED GROUND = DEDICATED GROUND(#) = ISOLATED GROUND<#> PANEL DESIGNATION: ELECTRICAL PANEL (ITEM 1) VOLTAGE: 120/240 MAIN LUGS: N/A CYCLE: 60 MAIN BREAKER: 200 AMP PHASE: 1 MAIN BREAKER A.I.C RATING: 22,000 A.I.C WIRES: 3 MAIN COPPER BUS: 200 AMP NEUTRAL: 200 AMPS BRANCH BREAKER A.I.C RATING: 10,000 A.I.C BRANCH BREAKER TYPE: SQUARE D - BOLT ON DESCRIPTION RECTIFIER #1 RECTIFIER #2 RECTIFIER #3 RECTIFIER #4 RECTIFIER #5 RECTIFIER #6 RECTIFIER #7 RECTIFIER #8 RECTIFIER #9 (OPTIONAL) RECTIFIER #10 (OPTIONAL) SPACE 1 3 5 7 9 11 13 15 17 19 21 23 25 27 31 29 33 35 37 41 39 8.000 8.000SUBTOTAL CONTINUOUS SUBTOTAL NON-CONTINUOUS SUBTOTAL SUB-PANEL - -- - LOAD UNIT KVAQT Y . 1 1 1 1 1.0001 1 1 1 1 1 1 1 1 1 1 1 1 1.000 LOAD PER PHASE (VA) PHASE A B WI R E C O L O R LO A D S CO N T I N U O U S LO A D S NO N - C O N T I N U O U S LO A D S S U B - P A N E L GR O U N D I N G W I R E SI Z E TR I P X X X X X X X X X BLK RED BLK RED BLK RED BLK RED BLK RED BLK RED BLK RED BLK RED BLK RED BLK RED BLK WI R E S I Z E 8 8 8 8 8 8 8 8 8 (10)40 (10)40 (10)40 (10)40 (10)40 (10)40 (10)40 (10)40 (10)40 TR I P GR O U N D I N G W I R E SI Z E WI R E S I Z E LO A D S S U B - P A N E L LO A D S NO N - C O N T I N U O U S LO A D S CO N T I N U O U S WI R E C O L O R LOAD PER PHASE (VA) PHASE A B UNIT KVA QT Y . DESCRIPTION LOAD BLK RED BLK RED BLK RED BLK RED BLK RED BLK RED BLK RED BLK RED BLK RED BLK RED BLK X X (10) (10) 8 8 50 50 20 15 15 12 12 12 12 12 12 SUBTOTAL CONTINUOUS SUBTOTAL NON-CONTINUOUS SUBTOTAL SUB-PANEL .010 8.478 7.86 -- 3.804 3.804 3.804 3.804 .72 0.150 0.256 3.804 3.804 3.804 3.804 0.180 0.064 0.150 1 1 1 1 4 4 1 HVAC #1 HVAC #2 INTERIOR RECEPTACLE INTERIOR LIGHTS EXTERIOR LIGHT TOTAL KVA CONTINUOUS x 1.25 TOTAL KVA NON-CONTINUOUS TOTAL KVA SUB-PANEL TOTAL KVA TOTAL AMPS 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 20.03 16.34 36.36 151.50 - 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 BLOCK HEATER BATTERY CHARGER 0.01 0.01 0.010 0.010 1 1 X X .010 SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE 20/1 20/1 AGC UTILITY 120/240V, 1PH, 3W ELECTRICAL INSTALLATION METHODS: 1.This installation shall comply with the currently adopted edition of the National Electrical Code and with utility company and local code requirements. 2.Install sufficient lengths of LFMC including all conduit fittings (nuts, reducing bushings, elbows, couplings, etc) necessary for connection from IMC or PVC conduit to the interior of the BTS cabinet. 3.Power, control and equipment ground wiring in tubing or conduit shall be single conductor (#14 AWG and larger), 600V, oil resistant THHN or THWN-2, Class B stranded copper cable rated for 90 C (wet and dry) operation; listed or labeled for the location and raceway system used. 4.Cut, coil and tape a 3 foot pigtail from end of LFMC for terminating by BTS equipment manufacturer. 5.Supplemental equipment ground wiring located indoors shall be single conductor (#6 AWG and larger), 600V, oil resistant THHN or THWN-2 green insulation, Class B stranded copper cable rated for 90 C (wet and dry) operation, listed or labeled for the location and raceway system used. 6.Supplemental equipment ground wiring located outdoors or below grade shall be single conductor #2 AWG solid, tinned, copper cable. 7.Power and control wiring, not in tubing or conduit, shall be multi-conductor, Type TC. Cable (#14 AWG and larger), 600V, oil resistant THHN or THWN-2, Class B, Stranded copper cable rated for 90 C (Wet or Dry) operation, with outer jacket listed or labeled for the location used. 8.Cables shall not be routed through ladder-style cable tray rungs. 9.Raceway and cable tray shall be listed or labeled for electrical use in accordance with NEMA, UL, ANSI/IEEE and NEC. 10.New raceway or cable tray shall match the existing installation where possible. 11.All power and grounding connections shall be crimp style, compression, wire lugs and wirenuts by Thomas and Betts (or equal). Lugs and wirenuts shall be rated for operation at no less than 75 C. 12.Each end of every power, grounding and T1 conductor and cable shall be labeled with color coded insulation or electrical tape. The identification method shall conform with NEC & OSHA and match existing installation requirements. 13.All electrical components shall be clearly labeled with engraved laminated plastic labels. All equipment shall be labeled with their voltage rating, phase configuration, wire configuration, power or ampacity rating and branch circuit ID numbers (panelboard and circuit identification). 14.All tie wraps shall be cut flush with approved cutting tool to remove sharp edges. 15.Rigid nonmetallic conduit (PVC Schedule 40 or PVC Schedule 80) shall be used underground, direct buried in areas of occasional light vehicle traffic or encased in reinforced concrete in areas of heavy vehicle traffic. 16.All conduit run above ground or exposed shall be LFMC, IMC or Rigid Steel. 17.Electrical metallic tubing (EMT) shall be used for concealed indoor locations. 18.Liquid tight flexible metallic conduit shall be used indoors and outdoors where vibration occurs or flexibility is needed. 19.Conduit and tubing fittings shall be threaded or compression type and approved for the location used. Setscrew fittings are not acceptable. 20.Cabinets, boxes and wireways shall be listed or labeled for electrical use in accordance with NEMA, UL, ANSI/IEEE and NEC. 21.Cabinets, boxes and wireways shall match the existing installation where possible. 22.Provide necessary tagging on the breakers, cables and distribution panels in accordance with applicable codes and standards to safeguard life and property. 23.The subcontractor shall review and inspect the existing facility grounding system and lightning protection system (as designed and installed) for strict compliance with the NEC. The site specific lightning protection code and general compliance with Telcordia and TIA grounding standards. The subcontractor shall report any violations or adverse findings to the contractor for resolution. 24.All electrode systems (including telecommunication, radio, lightning protection and AC power GES's) shall be bonded together at or below grade by two or more copper bonding conductors in accordance with the NEC. 25.Perform IEEE fall-of-potential resistance to earth testing (per IEEE 1100 and 81) for new ground electrode systems. The subcontractor shall furnish and install supplemental ground electrodes as needed to achieve a test result of 5 ohms or less. 26.Metal raceway shall not be used as the NEC required equipment ground conductor. Stranded copper conductors with green insulation sized in accordance with the NEC shall be furnished and installed with the power circuits to BTS equipment. 27.Each indoor BTS cabinet frame shall be directly connected to the master ground bar with supplemental equipment ground wires #6 or larger. 28.Exothermic welds shall be used for all grounding connections below grade. 29.Approved antioxidant coatings (i.e. conductive gel or paste) shall be used on all compression and bolted ground connections. 30.ICE bridge bonding conductors shall be exothermically bonded or bolted to the bridge and the tower ground bar. 31.Surfaces to be connected to ground conductors shall be cleaned to a bright surface at all connections. 32.Exposed ground connections shall be made with compression connectors which are then bolted to equipment using stainless steel hardware. Installation torque shall be per manufacturer's requirements. 33.DC power cables shall be Cobra COP-FLEX 2000, Flexible Class B or approved equal. 19 N.T.S. ELECTRICAL NOTES